Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Frequency Transformer Design for Modular Power Conversion From Medium-Voltage AC to 400 VDC

This paper presents a high-frequency modular medium-voltage AC (4160 VAC or 13.8 kVAC) to low-voltage DC (400 VDC) system that is scalable in order to be used for different scale microgrids. A 15 kW, 500 kHz DC/DC converter is demonstrated as the most important stage of the system overall, which can be scalable to a 225 kW 4160 VAC to 400 VDC system. Motivation of a CLLC resonant converter and its design parameters determination is carefully illustrated. The high-frequency transformer is the key element for the DC/DC converter. Then, the paper focuses on high-frequency transformer design to realize high-voltage insulation, high efficiency, and high density at the same time. Based on a split winding UU core transformer structure, transformer insulation materials and dimension parameters are determined referring to the IEEE insulation standard. The transformer magnetic loss model is reviewed based on which loss design tradeoff is carefully analyzed. Different working frequency impact on transformer design over three different core materials is also presented. Finally, a 500 kHz transformer prototype has been developed and demonstrated with the IEEE standard required insulation tests. A whole CLLC resonant converter is also present with experiments results. Here, the converter holds outstanding 98% efficiency and 2.9 kW/L power density.

42 ENGINEERING↗

Multilevel Switched-Capacitor AC–DC Step-Down Rectifier for Wireless Charging With Reduced Conduction Loss and Harmonic Content

In this paper, a wireless charging architecture employing a multilevel switched-capacitor (MSC) AC-DC rectifier is investigated. The proposed MSC rectifier features a multilevel design which is scalable to accommodate different power ratings and load ranges. The topology showcases advantages for wireless power transfer (WPT) systems in terms of compactness, efficiency, impedance tunability, and harmonic attenuation. The single-stage active topology is capable of varying its low-distortion staircase input voltage to tune the wireless power transfer system for high system-wide efficiency. A 7-level, 20 W prototype is used to verify the WPT loading and loss analysis. The prototype operates at 150 kHz with up to 3:1 step-down conversion ratio to an output voltage of 5.0 V. The experimental peak DC-to-DC efficiency is 93.8% and the rectifier peak efficiency is 98.3%. As a result. the rectifier demonstrates low waveform distortion and high efficiency across many WPT loading conditions, solidifying its place as a strong candidate for wireless power applications.

42 ENGINEERING↗

Failure Probability Constrained AC Optimal Power Flow

Despite cascading failures being the central cause of blackouts in power transmission systems, existing operational and planning decisions are made largely by ignoring their underlying cascade potential. This paper posits a reliability-aware AC Optimal Power Flow formulation that seeks to design a dispatch point which has a low operator-specified likelihood of triggering a cascade starting from any single component outage. By exploiting a recently developed analytical model of the probability of component failure, our Failure Probability-constrained ACOPF (FP-ACOPF) utilizes the system's expected first failure time as a smoothly tunable and interpretable signature of cascade risk. Here, we use techniques from bilevel optimization and numerical linear algebra to efficiently formulate and solve the FP-ACOPF using off-the-shelf solvers. Extensive simulations on the IEEE 118-bus case show that, when compared to the unconstrained and N-1 security-constrained ACOPF, our probability-constrained dispatch points can significantly lower the probabilities of long severe cascades and of large demand losses, while incurring only minor increases in total generation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Transmission and Distribution AC Optimal Power Flow

The current separate transmission and distribution energy management system faces multiple challenges associated with integrating distributed generators (DGs) into future grids. These challenges, such as a voltage rise issue resulting in curtailment of DGs, are difficult to solve via the current separate energy management. Thus, coordination between transmission and distribution is suggested, and a coordinated transmission and distribution AC optimal power flow (TDOPF) is proposed in this paper. A mathematical TDOPF model is established and analyzed in a master-slave structure. A heterogeneous decomposition algorithm (HGD), which is inspired by heterogeneous transmission and distribution characteristics, is proposed to solve the TDOPF in a distributed manner. The HGD is compared to other typical multi-area OPF decomposition algorithms and the differences are discussed. Numerical tests verify the benefit of the TDOPF to both transmission and distribution systems. The TDOPF improves economic operations, mitigates voltage rises, and decreases boundary bus mismatches. Hence, more DGs can be accommodated by the grid. In addition, a series of numerical tests indicate that the HGD competitively solves the TDOPF.

decomposition↗

Complete Genome Sequence of Sulfurospirillum Strain ACS TCE , a Tetrachloroethene-Respiring Anaerobe Isolated from Contaminated Soil

Here, we report the complete genome sequence of the tetrachloroethene-to-trichloroethene dechlorinator Sulfurospirillum sp. strain ACS TCE . The genome consists of a 38.05-kb circular plasmid and a 2.69-Mb circular chromosome, which encodes 3 identical reductive dehalogenases with 91.47% amino acid identity to the PceA of Sulfurospirillum multivorans strain DSM 12446.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanism of AC charge transport in TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0 and 0.03)

The dielectric properties and ac electrical conductivity of TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0, 0.03) single-crystals have been measured in the frequency range 5 × 10{sup 4} to 3.5 × 10{sup 7} Hz. Experimental data on the frequency dispersion of the dielectric coefficients and electrical conductivity of the TlSb{sub 1–x}Ga{sub x}S{sub 2} (x = 0, 0.03) single crystals have allowed us to identify the nature of the dielectric loss and the mechanism of charge transport and evaluate parameters of localized states in the band gap. The incorporation of gallium atoms into the crystal lattice of TlSbS{sub 2} crystals has been shown to lead to an increase in the Fermi-level density of states and mean hop time and distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of an External AC Electric Field on Plasma Turbulence in the Tokamak Near-Wall Layer

Braginskii reduced equations of two-fluid hydrodynamics are modified to take into account the presence of an external ac electric field localized in the tokamak near-wall layer. Numerical simulations show that, after reaching certain amplitude, such a field oscillating with the frequency ω ≈ ω{sub GAM} is capable of suppressing turbulent processes. The turbulence suppression mechanism consists in a sharp decrease in the growth rate of drift-resistive ballooning instability due to the appearance of additional nonlinear terms related to the external field in the equation for the vorticity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetocaloric Effect and Magnetostriction in a Ni{sub 49.3}Mn{sub 40.4}In{sub 10.3} Heusler Alloy in AC Magnetic Fields

The magnetocaloric effect (MCE) and the magnetostriction in the Ni{sub 49.3}Mn{sub 40.4}In{sub 10.3} Heusler alloy have been measured in ac magnetic fields to 8 T. It is shown that the contributions of the magnetic and structural subsystems to MCE have opposite signs; in this case, the contribution of the magnetic subsystem is dominant. The anomalous temperature dependence of the magnetostriction during the magnetostructural phase transition (PT) is explained by competition of the processes of growing austenite phase nuclei and the striction processes in them.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural characterization of the model amphipathic peptide Ac-LKKLLKLLKKLLKL-NH2 in aqueous solution and with 2,2,2-trifluoroethanol and 1,1,1,3,3,3-hexafluoroisopropanol

Short-chain amphiphilic peptides are promising components in the new generation of engineered biomaterials with many potential applications. The 14-residue leucine-lysine peptide Ac-LKKLLKLLKKLLKL-NH2 (LKα) is one such amphiphilic peptide. The periodic distribution of hydrophobic and hydrophilic amino acid residues in the sequence of LKα has been shown to promote α-helix formation in an ionic environment and at high peptide concentrations (> ~0.5 mM, no salt). Here, circular dichroism (CD) and nuclear magnetic resonance (NMR) spectroscopy is used to demonstrate that LKα, in the absence of salt and at concentrations < 0.5 mM, readily adopts a helical structure in the presence of the structure stabilizing agents 2,2,2-trifluoroethanol (TFE) and 1,1,1,3,3,3-hexafluoroisopropanol (HFIP). Maximal helical character, as monitored by negative bands with double minima at 222 and 208-210 nm in the CD spectrum, was observed in 20% TFE and 10% HFIP (volume percent). The helical character suggested by the CD data was corroborated with amide to alpha proton, long range, 1HN(i) to 1Hα(i-3) NOEs characteristic of an α-helical structure. In unbuffered water in the absence of a flouronated alcohol and at low peptide concentrations, LKα was essentially unstructured in solution. These observations confirm that LKα has a predisposition to adopt a helical structure that may be maximized with minimal amounts of fluorinated alcohol. This characterization of the structural and physical properties of LKα will assist the design of future biomaterials containing amphiphilic peptides.

biomaterials↗

Assessing Nonlinear Polarization in Electrochemical Cells using AC Impedance Spectroscopy

AC impedance spectroscopy is widely used to evaluate performance limitations in energy storage and conversion devices (e.g., batteries, supercapacitors, and fuel cells). This work shows that integrating the resistive elements in an equivalent circuit as functions of steady-state current enables one to recover overpotentials associated with different processes (e.g., ion migration, charge transfer, and diffusion) in nonlinear electrochemical power supplies. Closed form expressions for diffusion overpotentials are derived using this method for transmissive and reflective boundary conditions and three electrode symmetries (planar, cylindrical, and spherical). Discussion is also extended to macroscopically homogenous porous electrodes which are relevant for most real-world devices. Overall, the approach described herein is a powerful tool to identify rate-limiting steps and guide material/component design.

25 ENERGY STORAGE↗

Development of Mixed Matrix Membranes by Using NH 2 ‐Functionalized UiO‐66 and [APTMS][AC] Ionic Liquid for the Separation of CO 2

The ever‐escalating CO 2 concentration in the atmosphere calls for accelerated development and deployment of carbon capture processes to reduce emissions. Mixed matrix membranes (MMMs), which are fabricated by incorporating the beneficial properties of highly selective inorganic fillers into a polymer matrix, have exhibited significant progress and the ability to enhance the performance of a membrane for gas separation. In this research, an amine‐based ionic liquid (IL) [APTMS][AC] was prepared, which has greater CO 2 affinity and greater solubility due to its amine moiety. The metal–organic framework (MOF) UiO‐66 with a multidimensional crystalline structure was used as a filler due to its appropriate porosity and tunable properties, and it was functionalized with NH 2 . MOFs were further modified with an IL to prepare UiO‐66@IL and UiO‐66‐NH 2 @IL, and MMMs incorporating each MOF were fabricated with the polymer Pebax‐1657. All the prepared membranes and MOFs were characterized to predict their separation efficiency. Several characterization techniques, namely, FTIR spectroscopy, XRD, and SEM, were used to successfully synthesize UiO‐66@IL and UiO‐66‐NH 2 @IL composites and confirmed proper dispersion and excellent polymer‒filler compatibility at filler loadings ranging from 0 to 30 wt.%. The separation performances were investigated, and the results showed that the incorporation of RTIL with the highly crystalline structure and large surface area of UiO‐66 enhanced the separation efficiency of the membrane. The permeability of CO 2 for all fabricated membranes continuously increased with increasing filler concentration, wherein the permeability was comparatively high for the UiO‐66‐NH 2 MMMs. The CO 2 /CH 4 selectivity improved by 35%, 54%, and 60%, respectively, for UiO‐66@IL, UiO‐66‐NH 2 , and UiO‐66‐NH 2 @IL MMMs compared to simple UiO‐66 for CO 2 /CH 4 and by 28%, 36%, and 63%, respectively, for CO 2 /N 2 , with an increase in filler loading in the MMMs.

Khalid, Hafiza Mamoona (ORCID:0009000135165855)↗

Modelica Buildings Library Extension for AC and DC Building Comparison (Modelica DC Buildings) v1

This software simulates and compares the losses in AC and DC buildings. It uses formatted load profile data from EnergyPlus, PV generation data from PVWatts, realistic converter efficiency curves based on product data, a battery controller based on excess PV, and a realistic wire model. The software includes Modelica code, which is an extension of the Buildings Library Electrical models. It also includes Python code, which manages the Modelica parametric simulations and plots results.

Gerber, Daniel↗

Automation Tool to Create Chronological AC Power Flow Cases for Large Interconnected Systems

Combining planning models with operational details allows the industry to proactively investigate future resource and load scenarios, rather than react to their implementation in real time. In this project, the following tasks are proposed. The methodologies we developed to resolve current challenges in importing and solving the chronological AC power flow is a three-stage process.

Vyakaranam, Bharat↗

Solutions to remove a boundary image sticking in an ac plasma display panel

When displaying a square-type image with peak luminance for approximately 500 h in a 42 in. plasma display panel TV with high Xe (15%) content, halo-type boundary image sticking was observed in the nondischarge region adjacent to the discharge region. The halo-type boundary image sticking phenomenon is due mainly to the redeposit of the Mg species on the MgO layer in the nondischarge region adjacent to the discharge region, which is verified by measuring the redeposited Mg species in the boundary image sticking region using a cross-sectional scanning electron microscope. Based on this result, three kinds of solution to remove the boundary image sticking of an ac plasma display panel are introduced. First, we completely recover the boundary image sticking cells by using a full-white aging process. Second, we prohibit the inherent production of boundary image sticking by sealing the plasma display panel under vacuum. The final solution is to prohibit the inherent production of boundary image sticking by use of lower gas pressure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The allocation of a variable series reactor considering AC constraints and contingencies

The Variable Series Reactors (VSRs) can efficiently control the power flow through the adjustment of the line reactance. When they are appropriately allocated in the power network, the transmission congestion and generation cost can be reduced. Our work proposes a planning model to optimally allocate VSRs considering AC constraints and multi-scenarios including base case and contingencies. The planning model is originally a non-convex large scale mixed integer nonlinear program (MINLP), which is generally intractable. The proposed Benders approach decomposes the MINLP model into a mixed integer linear program (MILP) master problem and a number of nonlinear subproblems. Numerical case studies based on IEEE 118-bus demonstrate the high performance of the proposed approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗