Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Variation in osteocyte lacunar morphology and density in the human femur - a synchrotron radiation micro-CT study

In recent years there has been growing interest in the spatial properties of osteocytes (including density and morphology) and how these potentially relate to adaptation, disease and aging. This interest has, in part, arisen from the availability of increasingly high-resolution 3D imaging modalities such as synchrotron radiation (SR) micro-CT. As resolution increases, field of view generally decreases. Thus, while increasingly detailed spatial information is obtained, it is unclear how representative this information is of the skeleton or even the isolated bone. The purpose of this research was to describe the variation in osteocyte lacunar density, morphology and orientation within the femur from a healthy young male human. Multiple anterior, posterior, medial and lateral blocks (2 mm × 2 mm) were prepared from the proximal femoral shaft and SR micro-CT imaged at the Advanced Photon Source. Average lacunar densities (± standard deviation) from the anterior, posterior, medial and lateral regions were 27,169 ± 1935, 26,3643 ± 1262, 37,521 ± 6416 and 33,972 ± 2513 lacunae per mm 3 of bone tissue, respectively. These values were significantly different between the medial and both the anterior and posterior regions (p < 0.05). The density of the combined anterior and posterior regions was also significantly lower (p = 0.001) than the density of the combined medial and lateral regions. Although no difference was found in predominant orientation, shape differences were found; with the combined anterior and posterior regions having more elongated (p = 0.004) and flattened (p = 0.045) lacunae, than those of the medial and lateral regions. This study reveals variation in osteocyte lacunar density and morphology within the cross-section of a single bone and that this variation can be considerable (up to 30% difference in density between regions). The underlying functional significance of the observed variation in lacunar density likely relates to localized variations in loading conditions as the pattern corresponds well with mechanical axes. Lower density and more elongate shapes being associated with the antero-posterior oriented neutral axis. Our findings demonstrate that the functional and pathological interpretations that are increasingly being drawn from high resolution imaging of osteocyte lacunae need to be better situated within the broader context of normal variation, including that which occurs even within a single skeletal element.

Carter, Yasmin↗

Insight into the BiFeO 3 flash sintering process by in-situ energy dispersive X-ray diffraction (ED-XRD)

The sintering mechanism of BiFeO 3 has been investigated in-situ by energy dispersive X-ray diffraction (ED-XRD) using a high-energy white collimated X-ray beam from the Advanced Photon Source (Argonne National Laboratories). Such radiation is very penetrating thereby allowing measurements of the sample even when placed inside the flash sintering set up. Additionally, the fast ED-XRD measurements permit monitoring the flash sintering process by providing information about phase composition and sample temperature in real time. Moreover, profile scans, obtained by moving the stage vertically while recording the ED-XRD spectra, permit investigating the homogeneity of the flash for the entire length of the sample. All experiments have been complemented by ex-situ studies. Here, it has been concluded that flash sintering of BiFeO 3 is a homogeneous process without any directionality effects. Furthermore, flash sintering takes place at quite low temperatures (below the Tc ≈ 830 °C), which may be related to the high quality of the samples, as pure, highly insulating ceramics without evidence of secondary phases with a homogenous nanostructured grain size distribution are obtained by this technique. Moreover, it is also evidenced that the rapid heating of the sample does not seem to justify, at least by itself, the densification process. Therefore, it appears that the electric current should play a role in the enhanced mobility during the sintering process.

36 MATERIALS SCIENCE↗

High-speed X-ray study of process dynamics caused by surface features during continuous-wave laser polishing

During high-speed X-ray imaging of laser surface polishing experiments of specimens of 316L stainless steel at Argonne National Lab's Advanced Photon Source, it was discovered that the induced keyhole changes shape and dimensions while crossing an engineered surface feature without altering process parameters. It was observed that the post-surface feature keyhole was deeper than that of the pre surface feature keyhole. Here, this work reports on the first in-situ observation of the effect of localized surface geometry on underlying melt pool behavior. This has implications for defect formation mechanisms during laser melting processes that rely on melt pool geometry.

42 ENGINEERING↗

2D-imaging of sampling-probe perturbations in laminar premixed flames using Kr X-ray fluorescence

The perturbation of the temperature field caused by a quartz sampling probe has been investigated in a fuel-rich low-pressure premixed ethylene/oxygen/argon/krypton flame using X-ray fluorescence. The experiments were performed at the 7-BM beamline at the Advanced Photon Source (APS) at the Argonne National Laboratory where a continuous beam of X-rays at 15 keV was used to excite krypton atoms that were added to the unburnt flame gases in a concentration of 5% (by volume). The resulting krypton X-ray fluorescence at 12.65 keV was collected and the spatially resolved signal was subsequently converted into the local temperature of the imaged spot. One and two dimensional scans of the temperature field were obtained by translating the entire flame chamber through a pre-programmed sequence of positions on high precision translation stages and measuring the X-ray fluorescence at each location. Multiple measurements were performed at various separations between the burner surface and probe tip, representing sampling positions from the preheat, reaction, and postflame zones of the low-pressure flame. Distortions of up to 1000 K of the burner-probe centerline flame temperature were found with the tip of the probe in the preheat zone and distortions of up to 500 K were observed with it in the reaction and postflame zones. Furthermore, perturbations of the temperature field have been revealed that radially reach as far as 20 mm from the burner-probe centerline and about 3 mm in front of the probe tip. Finally, these results clearly reveal the limitations of one-dimensional models for predicting flame-sampling experiments and comments are made with regard to model developments and validations based on quantitative speciation data from low-pressure flames obtained via intrusive sampling techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental measurement of the rapid mixing of fuel and air in a multi-element diffusion (Hencken) burner

Flat flame burners are valuable tools for studying complex combustion phenomena like particle synthesis due to the well-controlled and well-behaved initial and boundary conditions. In this study, the methane/air flame temperature and tracer density profiles of a multi-element diffusion burner equipped with a central tube were characterized using krypton (Kr) x-ray fluorescence at the Advanced Photon Source at Argonne National Laboratory. The experiments were performed using a fuel-to-oxygen equivalence ratio of 0.8 and 3.3% Kr by volume was added to the reactant gases. One- and two-dimensional scans of non-combusting (i.e., cold flow) and combusting conditions, both with and without flow through the central tube were performed. Spatially-resolved Kr number density profiles were obtained at different planar locations and heights above the surface of the burner. The results show rapid mixing occurred near the exit-plane of the burner and increased spatial uniformity was achieved from 0.1 mm to 0.5 mm above the surface of the burner. Further, the data also showed the impact of the central tube flow on the main methane/air flame, including evidence of the central tube flow mixing with the main flow. Flame temperatures were calculated from the fluorescence measurements at various heights above the burner surface and were in good agreement with model predictions for a burner stabilized flame. These high-fidelity measurements provide accurate baseline data that are particularly valuable for understanding the effects of fuel and air mixing on downstream phenomena, such as the formation of condensed-phase products.

42 ENGINEERING↗

Synchrotron X-ray nano computed tomography based simulation of stress evolution in LiMn 2 O 4 electrodes

Here in this study, synchrotron X-ray nano-computed tomography at Advanced Photon Source in Argonne National Laboratory has been employed to reconstruct real 3D active particle morphology of LiMn 2 O 4 (LMO) commonly used in lithium-ion batteries (LIBs). For the first time, carbon-doped binder domain (CBD) has been included in the electrode structure as a 108 nm thick uniform layer using image processing technique. With this unique model, stress generated inside four LMO particles with a uniform layer of CBD has been simulated, demonstrating its strong dependence on local morphology (surface concavity and convexity), and the mechanical properties of CBD such as Young’s modulus. Specifically, high levels of stress have been found in vicinity of particle’s center or near surface concave regions, however much lower than the material failure limits even after discharging at the rate as high as 5C. On the other hand, the stress inside CBD has reached its mechanical limits when discharged at 5C, suggesting that it can potentially lead to failure by plastic deformation. The findings in this study highlight the importance of modeling LIB active particles with CBD and its appropriate compositional design and development to prevent the loss of electrical connectivity of the active particles from the percolated solid network and power losses due to CBD failure.

25 ENERGY STORAGE↗

Synchrotron-based X-ray fluorescence microscopy mapping the ionome of a toxic freshwater cyanobacterium

Harmful algal blooms (HABs) pose a major environmental concern across the globe. In abundance, cyanobacteria, or so-called green-blue algae can produce extremely dangerous cyanotoxins that harm humans and animals. This study focused on the mapping and distribution of intracellular macro-and micronutrients of the widespread freshwater cyanobacteria Microcystis aeruginosa (M. aeruginosa). Towards a better understanding of trace metal uptake and homeostasis throughout the cell cycle, we quantitatively mapped the spatial distribution of the elements P, K, Fe, Ca, Zn, Mn, and Cu across the ultrastructure of frozen-hydrated single cells using state-of-theart X-ray nanofluorescence imaging at the Advanced Photon Source (APS) at Argonne National Laboratory. Further, bulk cellular nutrient and trace metal content correlated well with the total intracellular elemental content in individual cells obtained by quantitative synchrotron X-ray fluorescence measurements. Multi-dimensional mappings showed P and K atoms colocalized as discrete semicircular hotspots that were analyzed with respect to their stoichiometry. Elevated Cu and Ca concentrations were detected along division plane of cells. P and K were found to have similar spatial elemental distribution with about 65% and 69% of the total cellular P and K, respectively, located at the hotspots. The P and K colocalization were refined further using nanotomography, showing a K envelope surrounding the P core. Inorganic P and organic P compounds were specified using solution-state 31 P nuclear magnetic resonance (NMR) spectroscopy from M. aeruginosa. Of the total extracted P determined by 31 P NMR spectroscopy, 47% were found to be nucleotides while only 11% were polyphosphates. Multimodal X-ray imaging provides a better understanding of intracellular biochemical processes in cyanobacteria, helping us monitor and combat an emerging environmental threat.

31P NMR spectroscopy↗

Spray flow structure from twin-hole diesel injector nozzles

Two techniques were used to study non-evaporating diesel sprays from common rail injectors which were equipped with twin-hole and single-hole nozzles for comparison. To characterise the sprays, high speed optical imaging and x-ray radiography were used. The former was performed at the LTRAC laboratory at Monash University, while the latter was performed at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. The optical imaging made use of high temporal, high spatial resolution spray recordings on a digital camera from which peripheral parameters in the initial injection phase were investigated based on edge detection. The x-ray radiography was used to explore quantitative mass distributions, which were measured on a point-wise basis at roughly similar sampling rate. Three twin-hole nozzles of different subtended angles and a single-hole nozzle were investigated at injection pressure of 1000 bar in environments of 20 bar back pressure. Evidence of strong cavitation was found for all nozzles examined with their C D ranging from 0.62 to 0.69. Penetration of the twin-hole nozzles was found to lag the single-hole nozzle, even before the sprays merged. Finally, switching in hole dominance was observed from one twin-hole nozzle, and this was accompanied by greater instability in mass flow during the transient opening phase of the injector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of X-ray scattering for tracer-free liquid-phase thermometry for multiphase flows

The feasibility of liquid temperature measurements using X-ray scattering is investigated for liquids with varying properties (water, ethanol, and n-dodecane) on beamline 7-BM at the Advanced Photon Source at Argonne National Laboratory. The temperature is inferred through the change in the scattering pattern from the liquid as a function of temperature using partial least squares regression. An accuracy of ~98% or higher was achieved enabling measurements for a wide range of applications.

42 ENGINEERING↗

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗

Detailed assessment of diesel spray atomization models using visible and X-ray extinction measurements

The physical mechanisms characterizing the breakup of a diesel spray into droplets are still unknown. This gap in knowledge has largely been due to the challenges of directly imaging this process or quantitatively measuring the outcomes of spray breakup, such as droplet size. Recent x-ray measurements by Argonne National Laboratory, utilized in this work, provide needed information about the spatial evolution of droplet sizes in selected regions of the spray under a range of injection pressures (50–150 MPa) and ambient densities (7.6–22.8 kg/m3) relevant for diesel operating conditions. Ultra-small angle x-ray scattering (USAXS) measurements performed at the Advanced Photon Source are presented, which quantify Sauter mean diameters (SMD) within optically thick regions of the spray that are inaccessible by conventional droplet sizing measurement techniques, namely in the near-nozzle region, along the spray centerline, and within the core of the spray. To quantify droplet sizes along the periphery of the spray, a complementary technique is proposed and introduced, which leverages the ratio of path-integrated x-ray and visible laser extinction (SAMR) measurements to quantify SMD. The SAMR and USAXS measurements are then utilized to evaluate current spray models used for engine computational fluid dynamic (CFD) simulations. We explore the ability of a carefully calibrated spray model, premised on aerodynamic wave growth theory, to capture the experimentally observed trends of SMD throughout the spray. The spray structure is best predicted with an aerodynamic primary and secondary breakup process that is represented with a slower time constant and larger formed droplet size than conventionally recommended for diesel spray models. Additionally, spray model predictions suggest that droplet collisions may not influence the resultant droplet size distribution along the spray centerline in downstream regions of the spray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard X-ray fluorescence spectroscopy of high pressure cavitating fluids in aluminum nozzles

X-rays are frequently used to study the internal geometry of dense objects, and to measure the density of multiphase flows. However, quantitatively measuring fluid density inside a metallic object such as a high pressure spray nozzle is difficult. X-rays of sufficiently high energy to penetrate a metal object are not appreciably absorbed by the fluid inside. This requires the use of plastic or beryllium test sections, which are not suited to high pressure conditions. We present a high-energy X-ray fluorescence technique which can overcome this problem. The experiments were conducted at the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory. A hydrocarbon fluid was seeded with cerium nanoparticles. The fluid was pumped at high pressure through aluminum nozzles with inner diameters of 0.36-0.90 mm and wall thicknesses of 2-3 mm. A collimated, monochromatic 42.5 keV X-ray beam excited K-edge fluorescence from the cerium. The K-alpha emission lines at 34-35 keV were recorded by a cryogenic germanium detector. Changes in fluid density due to cavitation of the liquid inside the nozzle were measured by raster scanning the nozzle across the beam. A spatial resolution of 20 x 20 mu m(2) was achieved with a slitted beam, which was improved to 5 x 10 mu m(2) with X-ray focusing mirrors. The uncertainty in the path-integrated vapor fraction was 30-40 mu m at 95% confidence. A limitation of this approach is that for low vapor pressure fluids, the nanoparticles increase the vapor pressure of the fluid and act as additional nucleation sites. These experiments demonstrate a path forward for measurements of multiphase flows inside metal components under conditions that are not feasible in optically accessible materials.

47 OTHER INSTRUMENTATION↗

Three-dimensional mapping of mineral in intact shark centra with energy dispersive x-ray diffraction

The centra of shark vertebrae consist of cartilage mineralized by a bioapatite similar to bone's carbonated hy-droxyapatite, and, without a repair mechanism analogous to remodeling in bone, these structures still survive millions of cycles of high-strain loading. The main structures of the centrum are an hourglass-shaped double cone and the intermedialia which supports the cones. Little is known about the nanostructure of shark centra, spe-cifically the relationship between bioapatite and cartilage fibers, and this study uses energy dispersive diffraction (EDD) with polychromatic synchrotron x-radiation to study the spatial organization of the mineral phase and its crystallographic texture. The unique energy-sensitive detector array at beamline 6-BM-B, the Advanced Photon Source, enables EDD to quantify the texture within each sampling volume with one exposure while constructing 3D maps via specimen translation across the sampling volume. Herein this study maps a centrum from two shark orders, a carcharhiniform and a lamniform, with different intermedialia structures. In the blue shark (Prionace glauca, Carcharhiniformes), the bioapatite's c-axes are oriented laterally within the centrum's cone walls but axially within the wide wedges of the intermedialia; the former is interpreted to resist lateral deformation, the latter to support axial loads. In the shortfin mako (Isurus oxyrinchus, Lamniformes), there is some tendency for c-axis variation with position, but the situation is unclear because one dimension of the sampling volume is consid-erably larger than the thickness and spacing of the intermedialia's radially-oriented lamellae. Because elastic modulus in collagen plus bioapatite mineralized tissues varies significantly with both volume fraction of bio-apatite and crystallographic texture, the present 3D EDD-derived maps should inform future 3D numerical models of shark centra under applied load.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic ordering in terbium at high pressures and low temperatures

We have investigated magnetic ordering in the heavy lanthanide terbium (Tb) for pressures up to 70 GPa and temperatures down to 20 K by synchrotron x-ray diffraction at the Advanced Photon Source, Argonne National Laboratory. The x-ray diffraction studies were complemented by neutron diffraction studies at the Spallation Neutron Source, Oak Ridge National Laboratory. We focused on the higher-pressure phases of Tb, such as the double hexagonal close-packed (dhcp, above 16 GPa), distorted face-centered cubic (hR24, above 30 GPa), and orthorhombic (oF16, above 51 GPa) phases. We observed the phenomenon of spontaneous magnetostriction in the dhcp and hR24 phases, where magnetic ordering at low temperatures gives rise to subtle splitting in x-ray diffraction peaks. The neutron diffraction study of the dhcp phase at 20 GPa revealed magnetic peaks that can be assigned a propagation vector k = ($\frac{1}{2}$, 0, $\frac{1}{2}$), and a magnetic ordering temperature that is consistent with the magnetostriction effect observed with x-ray diffraction. The high-pressure and low-temperature x-ray diffraction study at 70 GPa in the collapsed oF16 phase did not show any evidence of magnetostriction, indicating a significant decrease in the magnetic moment of the 4f-shell due to band broadening at ultra-high compression.

36 MATERIALS SCIENCE↗

Measurements of liquid and glass structures using in-situ high energy x-ray and neutron scattering

Investigation of high temperature molten materials and their evolution to the amorphous state is often hampered by unwanted reactions with container surfaces. This work used aerodynamic levitation in combination with laser beam heating to study high melting point materials that can form supercooled liquids or glasses. Details of the instruments that are being used at the Advanced Photon Source and the Spallation Neutron Source to study molten oxides with high energy x-ray scattering and neutron diffraction with isotope substitution are presented. Examples of measurements are used to illustrate the use of the instruments. Plans for further development and application of the capabilities are presented.

Weber, Richard↗

In situ X-ray diffraction study of the δ to α' isothermal martensitic transformation kinetics in a Pu–Ga alloy

The sequence of phase formation and the isothermal kinetics of the δ to α' phase transformation in a Pu–1.9 at.% Ga alloy are investigated with in situ X-ray diffraction at the Advanced Photon Source. It has been proposed that the formation of a γ' intermediate phase may be responsible for the unusual double-C curve kinetics reported for this isothermal martensitic transformation. While a γ' intermediate phase was not observed at either -120 °C or -155 °C, an unexplained shoulder on the δ (1 1 1) peak was detected at -155 °C. The isothermal kinetics of the δ → α' transformation appear to fit a Johnson–Mehl–Avrami–Kolmogorov equation, but the exponent is not described by existing JMAK theory. The double-C curve kinetics of the δ to α' transformation remain unresolved in plutonium science, and understanding this behavior is key to predicting phase stability in aging Pu–Ga alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗