Run 16, eIPM Summary

Three problems with the eIPMs were corrected during the 2015 summer shutdown. These involved ac coupling and 'negative profiles', detector 'dead zone' created by biasing, and gain control on ramp. With respect to Run 16, problems dealt with included gain depletion on horizontal MCP and rf pickup on profile signals; it was found that the MCP was severely damaged over part of the aperture. Various corrective measures were applied. Some results of these measured obtained during Run 16 are shown. At the end of Run 16 there was a three-­day beam run to study polarized proton beams in the AGS. Attempts to minimize beam injection errors which increase emittance by using the eIPMs to measure the contribution of injection mismatch to the AGS output beam emittance are recounted. .

43 PARTICLE ACCELERATORS↗

SU-E-J-23: Characteristics of X-Rays From ExacTrac and Patient Dose From Imaging Procedures

Purpose: The purpose of this investigation is 1) provide the beam characteristics of x-rays produced by a Novalis TX ExacTrac system; 2) present a method to commission such beams, 3) present radiation dose to patients resulting from the imaging procedures. Methods: The Monte Carlo simulations were used to obtain the characteristics of kV beams and validated by measurements. The calculated beam HVLs, profiles and depth-dose curves were benchmarked against measurements. Twelve different image acquisition protocols were studied. The x-ray tube voltage ranges from 70 - 145 kV and milliampere-second (mAs) ranges from 8 - 80 mAs depending on the selection of Cranium, Head & Neck, Thorax or Abdomen imaging protocols. The beam output of each image acquisition protocol was determined by using an ionization chamber. The air kerma calibration factors of the ion chamber were obtained from an Accredited Dosimetry Calibration Laboratory for specified HVLs. Results: The agreements between measured and simulated results were within the uncertainties for HVLs, dose profiles and depth-dose curves. When %dd was normalized at 1 cm depth, its values at depth of 5 cm ranged from 45% to 66% of in water for kV beams range from 70 kVp to 145 kVp respectively. For head images, a typical dose to eye resulting from single projection ranged from 0.008 cGy to 0.025 cGy depending on the cranial image protocols selected. For a single pelvic image the skin dose could reach up to 0.1 cGy from an abdominal protocol. Conclusion: Although multiple pairs of x-ray images are commonly acquired during a daily patient treatment, the imaging doses to patients resulting from the sum of these projected x-rays are generally much less than 0.5 cGy. The knowledge obtained from this investigation can be used to estimate the image dose and optimize the used of the system.

60 APPLIED LIFE SCIENCES↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗

Electro-optic sampling beam position monitor for relativistic electron beams

Here, an electro-optic sampling beam position monitor for installation at the SLAC National Accelerator Laboratory FACET-II facility is described. Simulations of the detector signal were performed using realistic electron beam current profiles, demonstrating that this single-shot, non-destructive, compact detector is capable of resolving the relative transverse offset and longitudinal separation of an ultra-relativistic, two-bunch electron beam to order 1 μm and 10 fs, respectively. A design study was performed to optimize the detector’s response to the ultra-relativistic two-bunch electron beam utilized in plasma wakefield accelerator experiments. In addition, the expected sensitivity to beam tilt is studied for typical electron beams used in free electron lasers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bowtie filters for dedicated breast CT: Theory and computational implementation

Purpose: To design bowtie filters with improved properties for dedicated breast CT to improve image quality and reduce dose to the patient. Methods: The authors present three different bowtie filters designed for a cylindrical 14-cm diameter phantom with a uniform composition of 40/60 breast tissue, which vary in their design objectives and performance improvements. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. Bowtie design #3 eliminates the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. All three designs are obtained using analytical computational methods and linear attenuation coefficients. Thus, the designs do not take into account the effects of scatter. The authors considered this to be a reasonable approach to the filter design problem since the use of Monte Carlo methods would have been computationally intensive. The filter profiles for a cone-angle of 0° were used for the entire length of each filter because the differences between those profiles and the correct cone-beam profiles for the cone angles in our system are very small, and the constant profiles allowed construction of the filters with the facilities available to us. For evaluation of the filters, we used Monte Carlo simulation techniques and the full cone-beam geometry. Images were generated with and without each bowtie filter to analyze the effect on dose distribution, noise uniformity, and contrast-to-noise ratio (CNR) homogeneity. Line profiles through the reconstructed images generated from the simulated projection images were also used as validation for the filter designs. Results: Examples of the three designs are presented. Initial verification of performance of the designs was done using analytical computations of HVL, intensity, and effective attenuation coefficient behind the phantom as a function of fan-angle with a cone-angle of 0°. The performance of the designs depends only weakly on incident spectrum and tissue composition. For all designs, the dynamic range requirement on the detector was reduced compared to the no-bowtie-filter case. Further verification of the filter designs was achieved through analysis of reconstructed images from simulations. Simulation data also showed that the use of our bowtie filters can reduce peripheral dose to the breast by 61% and provide uniform noise and CNR distributions. The bowtie filter design concepts validated in this work were then used to create a computational realization of a 3D anthropomorphic bowtie filter capable of achieving a constant effective attenuation coefficient behind the entire field-of-view of an anthropomorphic breast phantom. Conclusions: Three different bowtie filter designs that vary in performance improvements were described and evaluated using computational and simulation techniques. Results indicate that the designs are robust against variations in breast diameter, breast composition, and tube voltage, and that the use of these filters can reduce patient dose and improve image quality compared to the no-bowtie-filter case.

60 APPLIED LIFE SCIENCES↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on 30 m range gates (and 3 m range gates), stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, ran out of signal, below range, cloud-topped). Cloud Base Height (Haar-gradient detection): 10 min estimates of cloud-base height (m). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (3.0.1), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution (and 3 m for the year of 2025), with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min (10 min for Cloud Heights) summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx \SI{1}{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS↗

Calibration and Timing Performance of the Light Detection System in the ICARUS Detector

ICARUS is the largest Liquid Argon Time Projection Chamber (LArTPC) in operation and serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab. It aims to investigate the possible existence of sterile neutrinos with $\Delta m^2 \approx 1 \,\mathrm{eV^2}$ using the Booster Neutrino Beam (BNB) and explore physics beyond the Standard Model with the Neutrinos at the Main Injector (NuMI) beam. The ICARUS light detection system, comprising 360 TPB-coated large-area Photo-Multiplier Tubes (PMTs), is crucial for triggering and event reconstruction. Due to its shallow installation, the detector is exposed to a high flux of cosmic rays, necessitating precise timing to reject background events and align neutrino interactions with the beam time profile. This talk will detail the timing inter-calibration procedures for the ICARUS light detection system, which achieve sub-nanosecond resolution. Additionally, the performance of the system in reconstructing the timing of neutrino interactions from the BNB and NuMI beams will be discussed. The results highlight the effectiveness of the ICARUS light detection system in enhancing the detector's capability for precise and reliable neutrino selection.

43 PARTICLE ACCELERATORS↗

Self-focusing and defocusing of Gaussian laser beams in collisional underdense magnetized plasmas with considering the nonlinear ohmic heating and ponderomotive force effects

The propagation characteristics of a Gaussian laser beam in collisional magnetized plasma are investigated by considering the ponderomotive and ohmic heating nonlinearities. Here, by taking into account the effect of the external magnetic field, the second order differential equation of the dimensionless beam width parameter is solved numerically. Furthermore, the nonlinear dielectric permittivity of the mentioned plasma medium in the paraxial approximation and its dependence on the propagation characteristics of the Gaussian laser pulse is obtained, and its variation in terms of the dimensionless plasma length is analyzed at different initial normalized plasma and cyclotron frequencies. The results show that the dimensionless beam width parameter is strongly affected by the initial plasma frequency, magnetic strength, and laser pulse intensity. Furthermore, it is found that there exists a certain intensity value below which the laser pulse tends to self focus, while the beam diverges above of this value. In addition, the results confirm that, by increasing the plasma and cyclotron frequencies (plasma density and magnetic strength), the self-focusing effect can occur intensively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time capable modeling of neutral beam injection on NSTX-U using neural networks

A new model of heating, current drive, torque and other effects of neutral beam injection on NSTX-U that uses neural networks has been developed. The model has been trained and tested on the results of the Monte Carlo code NUBEAM for the database of experimental discharges taken during the first operational campaign of NSTX-U. By projecting flux surface quantities onto empirically derived basis functions, the model is able to efficiently and accurately reproduce the behavior of both scalars, like the total neutron rate and shine through, and profiles, like beam current drive and heating. The model has been tested on the NSTX-U real-time computer, demonstrating a rapid execution time orders of magnitude faster than the Monte Carlo code that is well suited for the iterative calculations needed to interpret experimental results, optimization during scenario development activities, and real-time plasma control applications. Simulation results of a proposed design for a nonlinear observer that embeds the neural network calculations to estimate the poloidal flux profile evolution, as well as effective charge and fast ion diffusivity, are presented.

Neural networks↗

SU-G-IeP4-04: DD-Neutron Source Collimation for Neutron Stimulated Emission Computed Tomography: A Monte Carlo Simulation Study

Purpose: To optimize collimation and shielding for a deuterium-deuterium (DD) neutron generator for an inexpensive and compact clinical neutron imaging system. The envisioned application is cancer diagnosis through Neutron Stimulated Emission Computed Tomography (NSECT). Methods: Collimator designs were tested with an isotropic 2.5 MeV neutron source through GEANT4 simulations. The collimator is a 52×52×52 cm{sup 3} polyethylene block coupled with a 1 cm lead sheet in sequence. Composite opening was modeled into the collimator to permit passage of neutrons. The opening varied in shape (cylindrical vs. tapered), size (1–5 cm source-side and target-side openings) and aperture placements (13–39 cm from source-side). Spatial and energy distribution of neutrons and gammas were tracked from each collimator design. Parameters analyzed were primary beam width (FWHM), divergence, and efficiency (percent transmission) for different configurations of the collimator. Select resultant outputs were then used for simulated NSECT imaging of a virtual breast phantom containing a 2.5 cm diameter tumor to assess the effect of the collimator on spatial resolution, noise, and scan time. Finally, composite shielding enclosure made of polyethylene and lead was designed and evaluated to block 99.99% of neutron and gamma radiation generated in the system. Results: Analysis of primary beam indicated the beam-width is linear to the aperture size. Increasing source-side opening allowed at least 20% more neutron throughput for all designs relative to the cylindrical openings. Maximum throughput for all designs was 364% relative to cylindrical openings. Conclusion: The work indicates potential for collimating and shielding a DD neutron generator for use in a clinical NSECT system. The proposed collimator designs produced a well-defined collimated neutron beam that can be used to image samples of interest with millimeter resolution. Balance in output efficiency, noise reduction, and scan time should be considered to determine the optimal design for specific NSECT applications.

60 APPLIED LIFE SCIENCES↗

Field testing of a convergent array of acoustic Doppler profilers for high-resolution velocimetry in energetic tidal currents

An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation.

Harding, Samuel F.↗

Real-time capable modeling of neutral beam injection on NSTX-U using neural networks

A new model of heating, current drive, torque and other effects of neutral beam injection on NSTX-U that uses neural networks has been developed. The model has been trained and tested on the results of the Monte Carlo code NUBEAM for the database of experimental discharges taken during the first operational campaign of NSTX-U. By projecting flux surface quantities onto empirically derived basis functions, the model is able to efficiently and accurately reproduce the behavior of both scalars, like the total neutron rate and shine through, and profiles, like beam current drive and heating. With this being said, the model has been tested on the NSTX-U real-time computer, demonstrating a rapid execution time orders of magnitude faster than the Monte Carlo code that is well suited for the iterative calculations needed to interpret experimental results, optimization during scenario development activities, and real-time plasma control applications. Simulation results of a proposed design for a nonlinear observer that embeds the neural network calculations to estimate the poloidal flux profile evolution, as well as Z eff and fast ion diffusivity, are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Square and Radial Geometries for High Intensity Laser Power Beaming Receivers

In an effort to further advance a realizable form of wireless power transmission (WPT), high intensity laser power beaming (HILPB) has been developed for both space and terrestrial applications. Unique optical-to-electrical receivers are employed with near infrared (IR-A) continuous-wave (CW) semiconductor lasers to experimentally investigate the HILPB system. In this paper, parasitic feedback, uneven illumination and the implications of receiver array geometries are considered and experimental hardware results for HILPB are presented. The TEM00 Gaussian energy profile of the laser beam presents a challenge to the effectiveness of the receiver to perform efficient photoelectric conversion, due to the resulting non-uniform illumination of the photovoltaic cell arrays. In this investigation, the geometry of the receiver is considered as a technique to tailor the receiver design to accommodate the Gaussian beam profile, and in doing so it is demonstrated that such a methodology is successful in generating bulk receiver output power levels reaching 25 W from 7.2 sq cm of photovoltaic cells. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers to achieve a 1.0 sq m receiver capable of generating over 30 kW of electrical power. This type of system would enable long range optical "refueling" of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion. In addition, a smaller HILPB receiver aperture size could be utilized to establish a robust optical communications link within environments containing high levels of background radiance, to achieve high signal to noise ratios.

Raible, Daniel E.↗