Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full wave simulation of waves in ECRIS plasmas based on the finite element method

This paper describes the modeling and the full wave numerical simulation of electromagnetic waves propagation and absorption in an anisotropic magnetized plasma filling the resonant cavity of an electron cyclotron resonance ion source (ECRIS). The model assumes inhomogeneous, dispersive and tensorial constitutive relations. Maxwell's equations are solved by the finite element method (FEM), using the COMSOL Multiphysics{sup ®} suite. All the relevant details have been considered in the model, including the non uniform external magnetostatic field used for plasma confinement, the local electron density profile resulting in the full-3D non uniform magnetized plasma complex dielectric tensor. The more accurate plasma simulations clearly show the importance of cavity effect on wave propagation and the effects of a resonant surface. These studies are the pillars for an improved ECRIS plasma modeling, that is mandatory to optimize the ion source output (beam intensity distribution and charge state, especially). Any new project concerning the advanced ECRIS design will take benefit by an adequate modeling of self-consistent wave absorption simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Windowed Fourier transform and cross-correlation algorithms for molecular tagging velocimetry

In this study, simulated and experimental molecular tagging velocimetry (MTV) images have been analyzed with a technique commonly used to process grid images on surfaces, the windowed Fourier transform with local spectrum analysis (WFT-LSA). A systematic synthetic image study of the modulation transfer function (MTF) and error tendencies of the WFT-LSA was performed and compared with a PIV-style cross-correlation algorithm to see if advanced strategies such as iterative image deformation can improve analysis of gridded images with high noise levels. Testing of single-pass algorithms showed that in typical MTV images, the WFT-LSA yields significantly lower bias errors than cross-correlation (CC) at displacements greater than 1 pixel but slightly higher random error at all displacements and image conditions. Analysis of the MTF shows that CC provided better resolution of spatial fluctuations than the WFT-LSA in many combinations of grid size and interrogation window. Tests of image deformation algorithms showed that the gap in performance between CC and WFT-LSA is maintained even as both methods improve. Additionally, WFT-LSA and CC methods are applied to real MTV experiments in high-speed gas jet flows. A preliminary analysis of phosphorescence lifetime provided by acetone vapor excited at 266 nm is used for assessing the required gas speeds for making MTV application feasible. The application of WFT-LSA to real MTV images demonstrates the ability of the algorithm to handle further real-world effects that could not be considered in the synthetic image analysis, like reduced signal-to-noise ratio and non-uniform intensity of the tagging grid across the image introduced by the actual laser beam energy distribution. With experimental images, CC is more accurate with shear flows but less robust to high noise levels than WFT-LSA, as predicted by the synthetic image analysis.

42 ENGINEERING↗

Comparisons of dense-plasma-focus kinetic simulations with experimental measurements

Dense-plasma-focus (DPF) Z-pinch devices are sources of copious high-energy electrons and ions, x rays, and neutrons. The mechanisms through which these physically simple devices generate such high-energy beams in a relatively short distance are not fully understood and past optimization efforts of these devices have been largely empirical. Previously we reported on fully kinetic simulations of a DPF and compared them with hybrid and fluid simulations of the same device. Here we present detailed comparisons between fully kinetic simulations and experimental data on a 1.2 kJ DPF with two electrode geometries, including neutron yield and ion beam energy distributions. A more intensive third calculation is presented which examines the effects of a fully detailed pulsed power driver model. We also compare simulated electromagnetic fluctuations with direct measurement of radiofrequency electromagnetic fluctuations in a DPF plasma. These comparisons indicate that the fully kinetic model captures the essential physics of these plasmas with high fidelity, and provide further evidence that anomalous resistivity in the plasma arises due to a kinetic instability near the lower hybrid frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dissociative Recombination of Cold HeH + Ions

The HeH + cation is the simplest molecular prototype of the indirect dissociative recombination (DR) process that proceeds through electron capture into Rydberg states of the corresponding neutral molecule. This Letter develops the first application of our recently developed energy-dependent frame transformation theory to the indirect DR processes. The theoretical model is based on the multichannel quantum-defect theory with the vibrational basis states computed using exterior complex scaling of the nuclear Hamiltonian. The ab initio electronic R-matrix theory is adopted to compute quantum defects as functions of the collision energy and of the internuclear distance. The resulting DR rates are convolved over the beam energy distributions relevant to a recent experiment at the Cryogenic Storage Ring, giving good agreement between the experiment and the theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Design of the Low-energy DC Gun for Field-emission Cathode Investigation

A DC electron source test-stand to explore fieldemission from various cathodes has been designed. The design also includes a provision to allow for laser-triggered field emission using a femtosecond laser source. The gun is instrumented to measure the beam transverse distribution, the transverse emittance, and I

43 PARTICLE ACCELERATORS↗

Characterization of groove density variation of VLS gratings with ALS XROL LTP-II in different operation modes

The long trace profiler, LTP-II, available at the Advanced Light Source (ALS) X-ray Optics Laboratory (XROL), was recently upgraded by replacing a multimode diode laser light source with a single-mode, wavelength-stabilized, fibercoupled diode laser system. The upgrade enables us to reliably characterize the lateral variation of groove density of variable-line-spacing (VLS) x-ray diffraction gratings. Here, we discuss the LTP-II performance with an example of measurements with a VLS grating with the groove density at the grating center of 300 lines/mm. For the measurements, we use the LTP-II in two different operation arrangements, the single Gaussian beam and the pencil beam interferometer arrangements. For each operation arrangement, we apply two data processing algorithms: with calculating the centroid position and with determining the position of a characteristic features of the detected beam intensity distributions. Additionally, we discuss the observed strong correlation between the LTP-II modes of operation and the resulted (extracted) groove density variations. We also speculate on possible origin of the correlation.

42 ENGINEERING↗

SU-E-T-183: Feasibility of Extreme Dose Escalation for Glioblastoma Multiforme Using 4π Radiotherapy

Purpose: GBM recurrence primarily occurs inside or near the high-dose radiation field of original tumor site requiring greater than 100 Gy to significantly improve local control. We utilize 4π non-coplanar radiotherapy to test the feasibility of planning target volume (PTV) margin expansions or extreme dose escalations without incurring additional radiation toxicities. Methods: 11 GBM patients treated with VMAT to a prescription dose of 59.4 Gy or 60 Gy were replanned with 4π. Original VMAT plans were created with 2 to 4 coplanar or non-coplanar arcs using 3 mm hi-res MLC. The 4π optimization, using 5 mm MLC, selected and inverse optimized 30 beams from a candidate pool of 1162 beams evenly distributed through 4π steradians. 4π plans were first compared to clinical plans using the same prescription dose. Two more studies were then performed to respectively escalate the GTV and PTV doses to 100 Gy, followed by a fourth plan expanding the PTV by 5 mm and maintaining the prescription dose. Results: The standard 4π plan significantly reduced (p<0.01) max and mean doses to critical structures by a range of 47.0–98.4% and 61.0–99.2%, respectively. The high dose PTV/high dose GTV/expanded PTV studies showed a reduction (p<0.05) or unchanged* (p>0.05) maximum dose of 72.1%/86.7%/77.1% (chiasm), 7.2%*/27.7%*/30.7% (brainstem), 39.8%*/84.2%/51.9%* (spinal cord), 69.0%/87.0%/66.9% (L eye), 76.2%/88.1%/84.1% (R eye), 95.0%/98.6%/97.5% (L lens), 93.9%/98.8%/97.6% (R lens), 74.3%/88.5%/72.4% (L optical nerve), 80.4%/91.3%/75.7% (R optical nerve), 64.8%/84.2%/44.9%* (L cochlea), and 85.2%/93.0%/78.0% (R cochlea), respectively. V30 and V36 for both brain and (brain - PTV) were reduced for all cases except the high dose PTV plan. PTV dose coverage increased for all 4π plans. Conclusion: Extreme dose escalation or further margin expansion is achievable using 4π, maintaining or reducing OAR doses. This study indicates that clinical trials employing 4π delivery using prescription doses up to 100 Gy are feasible. Funding support partially contributed by Varian.

60 APPLIED LIFE SCIENCES↗

Modification of Photovoltaic Laser-Power (λ = 808 nm) Converters Grown by LPE

Laser-power converters for the wavelength λ = 808 nm are fabricated by liquid-phase epitaxy (LPE) on the basis of n-Al{sub 0.07}GaAs–p-Al{sub 0.07}GaAs–p-Al{sub 0.25}GaAs single-junction heterostructures. The converters are tested with uniform (pulse simulator) and partly nonuniform (laser beam) illumination distribution over the photoreceiving surface. In the former case, a monochromatic efficiency of η = 53.1% is achieved for samples with an area of S = 4 cm{sup 2} at a power of 1.2 W. At S = 10.2 mm{sup 2} the efficiency is 58.3% at a laser power of 0.7 W.

14 SOLAR ENERGY↗

Shockwave-Initiated Emission of Ions from Stressed Granite

In this paper, we obtained intensity distributions of beams of positively charged ions emitted from the surface of uniaxially compressed granites under the effect of a shock wave. The intensity of beams decreases exponentially with an increase in the number of shock waves. The ions fly out at the moments when the dislocations reach the surface moving in intersecting slip planes. A compressive load suppresses the dislocation release and the intensity of ion beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonant Polarization Spectroscopy for Hot X-ray Plasmas

X-ray line polarization spectroscopy is a method of choice for probing hot plasma conditions. The precise roles of resonant structures in this method have not been realized and fully understood. With a sophisticated relativistic close coupling Dirac R-matrix calculation of polarized radiation of the quadrupole magnetic M2 line at 2.717 Å in Ba 46+ , we revealed the nature of resonant structures in x-ray line polarization spectroscopy. We found that signatures with a heavy resonance forest imprinting on polarization may be used for a sensitive new spectroscopic method. The resonant polarization spectrum was used to determine or constrain the directional beam electron distribution of the laboratory Ba plasma. Lastly, our results provide a start of resonant polarization spectroscopy as a method for diagnostics of laboratory, fusion and astrophysical plasma source conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Loss Simulation and Collimator System Configurations for the Advanced Photon Source Upgrade

The proposed multi-bend achromat lattice for the Advanced Photon Source upgrade (APS-U) has a design emittance of less than 70 pm. The Touschek loss rate is high: compared with the current APS ring, which has an average beam lifetime ~ 10 h, the simulated beam lifetime for APS-U is only ~2 h when operated in the high flux mode (I=200 mA in 48 bunches). An additional consequence of the short lifetime is that injection must be more frequent, which provides another potential source of particle loss. In order to provide information for the radiation shielding system evaluation and to avoid particle loss in sensitive locations around the ring (for example, insertion device straight sections), simulations of the detailed beam loss distribution have been performed. Several possible collimation configurations have been simulated and compared.

43 PARTICLE ACCELERATORS↗

Particle Rate and Host Accelerator Beam Loss on the MICE Experiment

A study is presented of particle rates in the MICE Muon Beamline and their relationship to beam loss produced in ISIS. A brief overview of neutrino physics is presented, together with a discussion on the Neutrino Factory as a motivation for MICE. An overview of MICE itself is then presented, highlighting the need for a systematic understanding of the relationship between the MICE target parameters, ISIS beam loss, and MICE particle rate. The variation of beam loss with target depth is examined and observed to be non-linear. The variation of beam loss with respect to the target dip time in the ISIS cycle is examined and observed to be approximately linear for dip times between 11.1 ms and 12.6 ms after ISIS injection, before tailing at earlier dip times. The variation of beam loss with particle rate is also observed to follow an approximately linear relationship from 0.05 V.ms to 4.7 V.ms beam loss, with a further strong indication that this continues up to 7.1 V.ms. Particle identification using time-of-flight data is used to give an insight into the relative abundances of each particle species present in the MICE beam. Estimates of muon rate are then produced as a function of beam loss. At a level of 2 V.ms beam loss ~10.9 muons per spill for a 3.2 ms spill with negative π → μ optics, and ~31.1 muons per 1 ms spill with positive π → μ optics are observed. Simulations using the ORBIT particle tracking code of the beam loss distributions around the ISIS ring, caused by the MICE target, are also presented and the implications for MICE running discussed.

43 PARTICLE ACCELERATORS↗

A COLD FLARE WITH DELAYED HEATING

Recently, a number of peculiar flares have been reported that demonstrate significant nonthermal particle signatures with low, if any, thermal emission, which implies a close association of the observed emission with the primary energy release/electron acceleration region. This paper presents a flare that appears “cold” at the impulsive phase, while displaying delayed heating later on. Using hard X-ray data from Konus- Wind , microwave observations by SSRT, RSTN, NoRH, and NoRP, context observations, and three-dimensional modeling, we study the energy release, particle acceleration, and transport, and the relationships between the nonthermal and thermal signatures. The flaring process is found to involve the interaction between a small loop and a big loop with the accelerated particles divided roughly equally between them. Precipitation of the electrons from the small loop produced only a weak thermal response because the loop volume was small, while the electrons trapped in the big loop lost most of their energy in the coronal part of the loop, which resulted in coronal plasma heating but no or only weak chromospheric evaporation, and thus unusually weak soft X-ray emission. The energy losses of the fast electrons in the big tenuous loop were slow, which resulted in the observed delay of the plasma heating. We determined that the impulsively accelerated electron population had a beamed angular distribution in the direction of the electric force along the magnetic field of the small loop. The accelerated particle transport in the big loop was primarily mediated by turbulent waves, which is similar to other reported cold flares.

79 ASTRONOMY AND ASTROPHYSICS↗

A Planar-Cavity Receiver Configuration for High-Temperature Solar Thermal Processes: Preprint

Next generation concentrating solar thermal power (CSP) and novel solar thermochemical systems using concentrating solar thermal (CST) energy require high operating temperatures exceeding those of traditional nitrate-salt CSP systems. Particle-based systems are attractive for next-generation CSP and CST applications owing to high-temperature stability of inert silica- or alumina-based particulate materials, the lack of low-temperature freezing concerns that limit molten salt and/or molten metal heat transfer media, and cost-effective thermal storage using low-cost particulate and containment materials. Open-cavity falling particle receivers have many potential advantages, but face challenges pertaining to scalability, thermal loss, and particle loss through the open aperture, and are infeasible for chemical processes that require a low-oxygen ambient environment. Enclosed receiver configurations can be scalable, avoid particle loss when heating particles, and have potential for future chemical processes; however, particle-based heat transfer media provide substantially lower heat transfer rates than liquid media, and thus enclosed particle receiver designs require novel configurations to limit surface temperatures under the high incident solar flux concentrations necessary for high receiver thermal efficiency at high temperature. This paper introduces the novel planar-cavity enclosed particle receiver configuration in which arrays of planar surfaces are arranged into sub-vertical cavities. Large angles between the panel surface normal vectors and the aperture surface normal allow the incoming solar beam to distribute along the panel walls. Correspondingly, a high incident solar flux concentration at the cavity aperture produces substantially lower absorbed solar flux concentration on any panel wall. Sets of individual vertical cavities can be arranged to form a scalable receiver configuration.

cavity receiver↗