End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of building energy asset rating using stock modelling in the USA

The US Building Energy Asset Score helps building stakeholders quickly gain insight into the efficiency of building systems (envelope, electrical and mechanical systems). A robust, easy-to-understand 10-point scoring system was developed to facilitate an unbiased comparison of similar building types across the country. The Asset Score does not rely on a database or specific building baselines to establish a rating. Rather, distributions of energy use intensity (EUI) for various building use types were constructed using Latin hypercube sampling and converted to a series of stepped linear scales to score buildings. A score is calculated based on the modelled source EUI after adjusting for climate. A web-based scoring tool, which incorporates an analytical engine and a simulation engine, was developed to standardize energy modelling and reduce implementation cost. This paper discusses the methodology used to perform several hundred thousand building simulation runs and develop the scoring scales.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coordinating the electric vehicle transition and electricity grid decarbonization in the U.S. is not essential to achieving substantial long-term carbon dioxide emissions reductions

Abstract How quickly the US can decarbonize light-duty vehicle (LDV) transportation depends on the rates of change of electric vehicle (EV) sales, stock turnover, and grid decarbonization. We build a stock turnover model to assess how sensitive achieving 2050 LDV decarbonization targets is to these rates. We estimate carbon dioxide (CO 2 ) reductions of 70%–85% by 2050, including emissions from vehicles and upstream electricity generation, provided that new vehicle sales transition to 100% EVs and substantial grid decarbonization are accomplished by 2050. This result is robust to continuation of long-term trends of increasing vehicle longevity, and to whether the timing of EV sales growth and grid decarbonization are coordinated. If the two key goals are met, the annual contribution of EV electricity use to CO 2 emissions will be small over the entire period.

Leard, Benjamin↗

End-Use Savings Shapes: Measure Documentation: Add Exhaust Air Heat/Energy Recovery

This documentation focuses on a single end-use savings shape measure—Add Exhaust Air Heat/Energy Recovery. This measure adds exhaust air energy recovery or heat recovery to existing air handling units (AHU) with outdoor air. Systems that already have energy/heat recovery are not modified. Furthermore, food service building types are also not modified by this measure due to the added complication of integrating cooking hood exhaust that could cause heat exchanger fouling from kitchen exhaust. In total, this measure is applicable airloops serving ~70% of the floor area in ComStock. In practice, energy/heat recovery systems are retrofitted to existing air delivery systems either as separate systems that provide outdoor air to the AHUs or are directly integrated to an AHU; the modeling approach used in this study is agnostic of the energy recovery type and simply accounts recovery effectiveness, added static pressure, and other controls which are described further in this document. Energy recovery with sensible and latent exchange gets added in humid climate zones, while heat recovery with sensible-only exchange gets added in drier climate zones. Energy recovery is modeled as a fixed membrane plate counterflow heat exchanger, while heat recovery is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and electric resistance preheat coil for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units with Original Fuel Backup

This documentation focuses on a single end-use savings shape measure—heat pump rooftop units with supplemental heat that matches the original fuel type of the replaced system; if the existing system used electric resistance heating, the supplemental heating source is electric resistance. If it was a natural gas furnace, the supplemental system is modeled as natural gas. This is a modification to the heat pump rooftop unit with electric supplemental heat measure from the Commercial EUSS 2023 Release 1 dataset. This document will primarily discuss the supplemental heating change for the heat pump RTU measure. For a comprehensive overview of the fundamental modeling methodology and background of the heat pump RTU measure, including performance curves and other key assumptions, please review the documentation for the original heat pump rooftop unit with electric supplemental heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scout Benchmark Scenarios for U.S. Building Energy and CO2 Emissions to 2050

Overview and Intended Use Cases: These scenarios establish a range of futures for U.S. buildings sector energy use and CO2 emissions to 2050 using Scout (scout.energy.gov), a reproducible and granular model of U.S. building energy use, emissions, and consumer costs developed by the U.S. national labs for the U.S. Department of Energy's Building Technologies Office (BTO). Scout benchmark scenario data are suitable for the following example use cases: setting high-level policy goals for the U.S. buildings sector to 2050 (e.g., X% building CO2 emissions reductions vs. 2005 levels by 2030, Y% reductions vs. 2005 levels by 2050); exploring the effects of key dynamics driving U.S. buildings sector energy and CO2 emissions to 2050 that could be affected by policy levers (e.g., raising minimum technology performance levels; accelerating electrification and/or retrofit rates; introducing breakthrough technologies to the market); determining priority segments (regions, building types, and end use/technology types) and sequencing of U.S. buildings sector energy and CO2 emissions reductions to 2050 under a given set of assumptions; and/or identifying the energy and emissions impacts or cost effectiveness of specific technologies or operational approaches of interest—in isolation or after considering competition with other measures in a scenario portfolio. Scenario Summary: A total of 8 scenarios explore the effects of changes across both the demand- and supply-side of building energy use on annual U.S. building energy use and CO2 emissions from 2022–2050. Scenarios are organized into three groups representing low, moderate, and best-case potentials for building decarbonization, respectively.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 1 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 1 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Efficient Electric Vehicle Adoption With Level 2 Charging

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Efficient Electric Vehicle Adoption With Level 2 Charging" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Efficient Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Efficient Electric Vehicle Adoption With Level 2 Charging and Demand Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Window Film

This documentation focuses on a single end-use savings shape measure - window film. The window film studied in this analysis, called solar control film, is a passive retrofit solution for windows that does not involve window replacement. This type of film is composed of transparent, tinted, or metalized laminated polyester layers and can be attached to an existing window surface (either on the exterior or interior side of the window). The properties of the window film are designed to shift the thermal and optical performances of the overall glazing system in order to serve various needs the customer would have (e.g., heat, glare). While the practical goal of purchasing and installing a window film varies widely in the real market, this study only focuses on the goal of energy savings, and highlighting the corresponding emissions. Other important aspects that customers typically consider include visual comfort, privacy, aesthetics, ultraviolet protection, etc. Thus, in practice, customers often choose a window film product not only to save energy (or cost) but also to mitigate issues around glare, excessive light, daytime privacy, or inconsistent appearance of the building. Window film products that were modeled in this analysis significantly reduced the solar heat gain coefficient of the overall glazing system, resulting in better energy savings for buildings in hot climate regions. However, significantly reducing the solar heat gain coefficient that can block unfavorable heat during the summer can actually harm blocking favorable heat during the winter. By applying window films on a stock of buildings covering various load and weather conditions, this analysis highlights when (e.g., time of day) and where (e.g., geospacial location) we can save energy with window films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

The impact of behavioral and geographic heterogeneity on residential-sector carbon abatement costs

Analyses of monetary and emissions savings from residential efficiency upgrades usually neglect behavioral differences between consumers. Variations in behavior are frequently large: 13% of the U.S. population sets thermostats for cooling at 20 °C (68 °F) or lower and 15% at 25.5 °C (78 °F) or higher. Efficiency analyses should account for behavioral heterogeneity as well as variations in climate and housing characteristics. We model energy and economic savings of efficiency upgrades for U.S. single-family detached houses, accounting for differences in thermostat settings, climate zone, fuel prices, and home characteristics. We consider five efficiency interventions: wall insulation, attic insulation, air sealing, high-efficiency furnaces, and high-efficiency air conditioners. Energy and economic savings vary widely by consumer; the average net present value for wall insulation is $3,020 United States Dollar (USD), but considering heterogeneity, it has a 10th percentile value of -$231 and 90th percentile value of $5,000. Neglecting heterogeneity, technology upgrades can be prioritized from lower to higher carbon abatement costs: air conditioners, wall insulation, furnace, air sealing, and attic insulation. Accounting for heterogeneity reorders this prioritization, and consumer-specific conditions affect mitigation costs such that technologies are mixed in with one another and are no longer arranged one after another. These results indicate that interventions to improve efficiency should consider differences between consumers.