Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Pixel-Level Calibration in the Kepler Science Operations Center Pipeline

We present an overview of the pixel-level calibration of flight data from the Kepler Mission performed within the Kepler Science Operations Center Science Processing Pipeline. This article describes the calibration (CAL) module, which operates on original spacecraft data to remove instrument effects and other artifacts that pollute the data. Traditional CCD data reduction is performed (removal of instrument/detector effects such as bias and dark current), in addition to pixel-level calibration (correcting for cosmic rays and variations in pixel sensitivity), Kepler-specific corrections (removing smear signals which result from the lack of a shutter on the photometer and correcting for distortions induced by the readout electronics), and additional operations that are needed due to the complexity and large volume of flight data. CAL operates on long (~30 min) and short (~1 min) sampled data, as well as full-frame images, and produces calibrated pixel flux time series, uncertainties, and other metrics that are used in subsequent Pipeline modules. The raw and calibrated data are also archived in the Multi-mission Archive at Space Telescope at the Space Telescope Science Institute for use by the astronomical community.

Calibration↗

N20 VIIRS RSB Calibration Algorithms and Results: Collection 2.0

The NOAA-20 (N20) satellite, previously the Joint Polar Satellite System-1 satellite, was launched on November 18, 2017. One of the five major scientific instruments aboard the satellite is the Visible Infrared Imaging Radiometer Suite (VIIRS). VIIRS scans the Earth’s surface in 22 spectral bands, 14 of which are the reflective solar bands (RSBs) with band center wavelengths from 0.412 to 2.25μm. VIIRS regularly performs on-orbit radiometric calibration of its RSBs, primarily through the observations of the onboard solar diffuser (SD). The on-orbit change of the SD’s bidirectional reflectance distribution function, known as the H-factor, is determined by the onboard SD stability monitor (SDSM). Since the H-factor exhibits angular dependence, obtaining the H-factor along the SD to the telescope direction is a challenge for the NOAA-20 VIIRS. Recently, Collection 2.0 of the NASA Land Science Investigator-led Processing Systems (SIPS) products were released. As a part of this reprocessing effort, we made two major improvements in the N20 VIIRS RSB radiometric calibration. One is the improved SD and SDSM attenuation screen transmittance functions, obtained by using calibration data collected during both the yaw maneuver and a small portion of regular orbits, resulting in a higher quality H-factor for the SDSM view. Another is the use of the H-factor for the telescope view, derived from the H-factor for the SDSM view, by using the results for the SNPP VIIRS. In June 2019, we delivered a set of mission-long N20 VIIRS Collection 2.0 RSB radiometric calibration look-up-tables. These tables have been employed by the NASA Land SIPS group to reprocess the entire time series of the NOAA-20 VIIRS products. In this paper, we discuss the Collection 2.0 NOAA-20 VIIRS RSB calibration algorithms and results.

N20 VIIRS↗

NOAA-20 Visible Infrared Imaging Radiometer Suite day–night band on-orbit calibration and performance

The NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument has been successfully operating on orbit since November 28, 2017. The day–night band (DNB) onboard NOAA-20 VIIRS is a panchromatic channel covering wavelengths from 0.5 to 0.9 μm, capable of observing the Earth scene in visible/near-infrared spectral range at a spatial resolution of 750 m. The DNB operates at low-, mid-, or high-radiometric gain stages, and it uses an onboard solar diffuser (SD) panel for low-gain stage calibration. The SD observations also provide a means to compute gain ratios between low-to-mid and mid-to-high-gain stages. With their large dynamic range and high sensitivity, the DNB detectors can make observations during both daytime and nighttime. We provide an assessment of the DNB on-orbit performance and behavior in the first two-year mission period and beyond. The calibration methodology used by the VIIRS Characterization Support Team in support of the NASA Earth science community has been described. The trending of on-board calibrators dark-offsets, SD gains, and gain ratios, and signal-to-noise ratio at minimum radiance have been analyzed, especially during key events such as the nadir and cryocooler doors opening. Furthermore, we performed intercomparison studies between Suomi National Polar-orbiting Partnership and NOAA-20 instruments and evaluated DNB radiometric calibration and characterization, including the SD degradation, detector gains, gain ratios, and straylight correction, as well as the calibration comparison between the NOAA Interface Data Processing Segment look-up-tables and our delivery results.

VIIRS↗

An Improved Weighted Least Squares Algorithm for the Analysis of Strain-Gage Balance Calibration Data

An improved version of an algorithm is presented that uses a weighted least squares fit of balance calibration data for the generation of the balance load prediction equations. The weighted least squares fit assigns a weighting factor between zero and one to each calibration data point that depends on a simple count of the number of intentionally loaded balance gages. The greater the number of the loaded gages is, the smaller a data point's weighting factor becomes. This strategy has two advantages. First, single-component loads become more influential during the regression analysis of the calibration data. In addition, the negative influence of load schedule asymmetries on the regression analysis results can more effectively be controlled. The original algorithm of 2017 was improved in 2020. Now, gage output differences relative to the natural zeros are exclusively used as input for the determination of the number of intentionally loaded gages. The improved weighted least squares fit can be applied with both the Non-Iterative Method and the Iterative Method that are used for the balance load prediction in the aerospace testing community. Machine calibration data of a force balance is used to illustrate benefits of the application of the improved weighted least squares fit of balance calibration data.

strain-gage balance↗

Assessment of VIIRS Day-Night Band High Gain Calibration Using Stars

The VIIRS has a unique spectral band that can sense reflected light from space during both day and nighttime, thus referred to as the day-night band (DNB). This band operates in three different gain stages: low, mid, and high gain (LG, MG, and HG) that cover a remarkable dynamic range with its HG stage being extremely sensitive to low-light scenes. Similar to its reflective solar bands, the VIIRS uses an on-board solar diffuser for its DNB LG stage calibration, whereas the DNB MG and HG calibrations are performed using relative or ratioing approaches. In this paper, we provide an assessment of VIIRS DNB HG calibrations using stars that appear in the field-of-view of its space view (SV), focusing on the computation of the gain trending and associated tool development. We also describe various strategies and procedures developed for DNB HG calibration stability monitoring and inter-comparisons among different VIIRS instruments and discuss some of the complications and limits to this approach, including under-sampling of the stellar image, saturation, and crowding. For S-NPP VIIRS, it includes the use of the modulated relative spectral response (RSR) resulting from wavelength-dependent degradation of the sensor optics. Results show that the star-based response trending for the DNB HG is consistent with that derived from on-board solar diffuser and that the calibration difference between S-NPP and N-20 VIIRS DNB requires additional effort to address, especially for research studies and applications using data from both sensors.

VIIRS↗

Soil Moisture Active/Passive (SMAP) L-Band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The soil moisture active passive (SMAP) microwave radiometer is a fully-polarimetric L -band radiometer flown on the SMAP satellite in a 6 AM /6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version 4 was released in 2018, the radiometer has undergone further calibration and validation. The goal is to reduce the difference between antenna temperature of ascending and descending orbits during the eclipse, and to reduce the dips in the calibration drift over the cold sky (CS) during the eclipse seasons in 2017 and 2018. The postlaunch calibration algorithm has been revisited by retrieving all of the calibration parameters simultaneously with two different options for the hot calibration source (the global ocean, or the radiometer internal reference load). The performance of the two options are compared here. The option with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with the SMAP synthetic aperture radar transmitter operating alongside the radiometer.

calibration↗

Vicarious Calibration of the Long Near Infrared Band: Cross-Sensor Differences in Sensitivity

Numerous assumptions and approximations are employed when translating satellite-derived radiance to surface remote sensing reflectance (RRS) for ocean color applications. Among these is the vicarious calibration coefficient (g) of the “long” near infrared band (NIRL) used for atmospheric correction. For this band, the prelaunch calibration has always been deemed sufficient [thus g(NIRL) = 1.00] as long as other bands are vicariously calibrated. Recent research, however, suggests that Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua RRS time series is quite sensitive to g(NIRL) (and associated vicarious gains in other bands). In this work, we assessed the sensitivity of Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP) RRS to NIRL calibration and compared our results to previous MODIS/Aqua and Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS)/OrbView2 analysis. In doing so, we note that g(NIRL) sensitivities of mission-averaged RRS time series are lower for VIIRS and Sea-WiFS, relative to MODIS. At the scale of monthly climatologies (MCs), however, all sensors show prominent g(NIRL) sensitivity with that of SeaWiFS being the most substantial. These findings informed simulation analyses, whereby we identified signal-tonoise ratio (SNR) and radiant path geometry, as well as their interaction, as having notable impacts on g(NIRL) sensitivity. As such, g(NIRL) sensitivity is a necessary consideration for reflectance uncertainty budgets, especially for sensors with higher NIR SNR or particular prevailing radiant path geometries. Given the geometry components embedded within g(NIRL) sensitivity, such studies should be coupled with cross-sensor intercalibrations [e.g., using simultaneous same view (SSV) measurements] toward minimizing NIRL errors between satellite instruments, but such efforts will not completely remediate remaining cross-sensor biases in RRS. Index Terms—Moderate Resolution Imaging Spectroradiometer (MODIS)/Aqua, ocean color, ocean gyres, Sea-viewing Wide Field-of-View Sensor onboard OrbView2 (SeaWiFS), system vicarious calibration (SVC), Visible Infrared Imaging Radiometer Suite onboard the Suomi National Polar-orbiting Partnership satellite (VIIRS/SNPP).

MODIS↗

Evaluating the Calibration and Validation of the Clouds and the Earth’s Radiant Energy System (CERES) instruments on Terra and Aqua Over Twenty Years

Six Clouds and the Earth’s Radiant Energy System (CERES) instruments on four satellites are used to produce a global continuous multi-decadal record of Earth’s radiation budget (ERB) at the top-of-atmosphere (TOA). Each CERES instrument was calibrated and characterized on the ground before launch, while post-launch calibration is conducted using on-board calibration sources. The performance of the CERES instruments is verified using vicarious approaches involving both Earth and celestial targets. In this paper, we describe the calibration and validation approach and demonstrate the performance of the CERES instruments on the Terra and Aqua spacecrafts over the twenty-year period since launch. Validation results demonstrate that after applying the appropriate calibration corrections, all four instruments are stable and perform consistently with each other. Comparisons of observations between instruments on the two spacecrafts during orbital crossings further confirm the consistent performance across all instruments over the twenty year period.

Terra↗

A low-latitude, high-elevation 10Be production-rate calibration from the Rwenzori Mountains, Uganda

Cosmogenic nuclide surface-exposure dating has become a key tool in geomorphology. Robust application of the technique relies on determination of local nuclide production rates using independently dated calibration sites. However, there are few existing calibration sites in certain regions, particularly in low-latitude, high-elevation regions where cosmogenic nuclide production is theoretically more sensitive to changes in Earth's magnetic field and atmospheric conditions. We present a new cosmogenic beryllium-10 (10Be) production-rate calibration from the equatorial Rwenzori Mountains in Uganda. The calibration is based on radiocarbon dating of basal lake sediments (∼21.3 kyr BP) from Lake Mahoma (2900 m asl) and measured 10Be concentrations from boulders on the crest of a moraine which dams the lake. Our results indicate a time-integrated 10Be production rate of 15.83 ± 0.81 at/g/yr at Lake Mahoma. We then use these calibration data and two public online calculators to calculate ages for moraines in a separate Rwenzori valley for which there exists a minimum-limiting radiocarbon age constraint (∼12 kyr BP) on surficial glacial sediments. This enables us to assess the performance of different parameters used to scale production rates spatially and temporally (e.g., scaling frameworks, geomagnetic field reconstructions, atmospheric models) for surface-exposure age calculation in the region. Our results highlight the sensitivity of low-latitude cosmogenic nuclide surface-exposure ages to discrete calculation parameters, such as scaling framework or reconstructions of Earth's magnetic field, and the utility of determining production rates at sites where limiting age data exists for other nearby landforms.

Anderson, N [Dartmouth College]↗

A Diffusion‐Based Uncertainty Quantification Method to Advance E3SM Land Model Calibration

Abstract Calibrating land surface models and accurately quantifying their uncertainty are crucial for improving the reliability of simulations of complex environmental processes. This, in turn, advances our predictive understanding of ecosystems and supports climate‐resilient decision‐making. Traditional calibration methods, however, face challenges of high computational costs and difficulties in accurately quantifying parameter uncertainties. To address these issues, we develop a diffusion‐based uncertainty quantification (DBUQ) method. Unlike conventional generative diffusion methods, which are computationally expensive and memory‐intensive, DBUQ innovates by formulating a parameterized generative model and approximates this model through supervised learning, which enables quick generation of parameter posterior samples to quantify its uncertainty. DBUQ is effective, efficient, and general‐purpose, making it suitable for site‐specific ecosystem model calibration and broadly applicable for parameter uncertainty quantification across various earth system models. In this study, we applied DBUQ to calibrate the Energy Exascale Earth System Model land model at the Missouri Ozark AmeriFlux forest site. Results indicated that DBUQ produced accurate parameter posterior distributions similar to those from Markov Chain Monte Carlo sampling but with 30 times less computing time. This significant improvement in efficiency suggests that DBUQ can enable rapid, site‐level model calibration at a global scale, enhancing our predictive understanding of climate impacts on terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Galaxy cluster matter profiles - I. Self-similarity, mass calibration, and observable-mass relation validation employing cluster mass posteriors

We present a study of the weak lensing inferred matter profiles ΔΣ(R) of 698 South Pole Telescope (SPT) thermal Sunyaev-Zel’dovich effect (tSZE) selected and MCMF optically confirmed galaxy clusters in the redshift range 0.25 < z < 0.94 that have associated weak gravitational lensing shear profiles from the Dark Energy Survey (DES). Rescaling these profiles to account for the mass dependent size and the redshift dependent density produces average rescaled matter profiles ΔΣ(R/R200c)/(ρcritR200c) with a lower dispersion than the unscaled ΔΣ(R) versions, indicating a significant degree of self-similarity. Galaxy clusters from hydrodynamical simulations also exhibit matter profiles that suggest a high degree of self-similarity, with RMS variation among the average rescaled matter profiles with redshift and mass falling by a factor of approximately six and 23, respectively, compared to the unscaled average matter profiles. We employed this regularity in a new Bayesian method for weak lensing mass calibration that employs the so-called cluster mass posterior P(M200|ζ̂, λ̂, z), which describes the individual cluster masses given their tSZE (ζ̂) and optical (λ̂, z) observables. This method enables simultaneous constraints on richness λ-mass and tSZE detection significance ζ-mass relations using average rescaled cluster matter profiles. We validated the method using realistic mock datasets and present observable-mass relation constraints for the SPT×DES sample, where we constrained the amplitude, mass trend, redshift trend, and intrinsic scatter. Our observable-mass relation results are in agreement with the mass calibration derived from the recent cosmological analysis of the SPT×DES data based on a cluster-by-cluster lensing calibration. Our new mass calibration technique offers a higher efficiency when compared to the single cluster calibration technique. We present new validation tests of the observable-mass relation that indicate the underlying power-law form and scatter are adequate to describe the real cluster sample but that also suggest a redshift variation in the intrinsic scatter of the λ-mass relation may offer a better description. In addition, the average rescaled matter profiles offer high signal-to-noise ratio (S/N) constraints on the shape of real cluster matter profiles, which are in good agreement with available hydrodynamical ΛCDM simulations. This high S/N profile contains information about baryon feedback, the collisional nature of dark matter, and potential deviations from general relativity.Key words: gravitational lensing: weak / galaxies: clusters: general / large-scale structure of Universe

79 ASTRONOMY AND ASTROPHYSICS↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CaliQEC: In-situ Qubit Calibration for Surface Code Quantum Error Correction

Quantum Error Correction (QEC) is essential for fault-tolerant, large-scale quantum computation. However, error drift in qubits undermines QEC performance during long computations, necessitating frequent calibration. Conventional calibration methods disrupt quantum states, requiring system downtime and rendering in situ calibration impractical. To address this challenge, we propose QECali, a novel framework that enables in situ calibration for surface codes. Our evaluation demonstrates that QECali introduces modest qubit overhead and negligible increases in execution time, offering the first practical solution for in situ calibration in surface code based quantum computation.

Fang, Xiang [University of California, Santa Barba↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Automated Calibration System for Beam Current Monitor

The Beam Current Monitor (BCM) measures the instantaneous current in a beam. This work aims to develop an automated calibration system for the BCM to address the need for calibration without interrupting beam operation. We strive to create a synchronous calibration method integrated into the master timeline by utilizing the pulsed nature of synchrotrons to run calibration pulses during inter-pulse gaps. This improvement should enhance operational efficiency, ensure safe operation, and help mitigate beam loss, all by enabling intermittent calibration during the operation of the accelerator. This is accomplished by developing a Python program that interfaces with a Keithley 6221 DC and AC source and a Keithley 2182A Nanovoltmeter. The program configures both of these devices to perform a selected mode of the current sweep, allows for the initiation of the current sweep, collects the measured voltage data from the 2182A, stores the collected data to the computer in a CSV file, and graphs the collected data.

Haller, James↗

Calibration of Al7075 with Plate-Puncture Predictions

The following details calibration of a material model for Al7075-T6511. This aluminum alloy is commonly used across a host of engineering applications. Owing to its widespread prevalence, there is great benefit in improving simulation predictions for this alloy. In the present effort, a calibration is performed of its elastic-plastic response accounting for both rate and temperature dependence. The calibration is informed by a series of tests that include specimens of different geometries tested at different rates and temperatures. All specimens are derived from the same barstock, 3.5 inches in diameter. The fitted model itself uses an anisotropic, Hill yield surface coupled with a Johnson-Cook hardening model. Failure predictions are had by means of a modified Wilkins failure criterion. Following calibration of the material model, a validation exercise is performed against platepuncture experiments. These experiments include multiple probe shapes, probe diameters, and plate thicknesses. The puncture experiments are replicated in simulation with mesh studies performed to assess uncertainty. Key quantities of interest, notably the absorbed energy up to failure, are compared between simulation and experiment providing a means to assess the suitability of the calibration in puncture simulations.

36 MATERIALS SCIENCE↗

Performance and automatic calibration scheme of the waveform sampler in the ETROC2 ASIC chip

The waveform sampler in the CMS ETROC2 chip for LGAD gain aging monitoring is a 2.56-GS/s 12-bit 8x-Interleaved ADC that consists of a coarse SAR stage, and a fine stage. This architecture delivers high performance on a relatively modest 65 nm process, while requires finding up to 24 calibration constants through calibration. We developed an automatic calibration method using charge injection test data. After calibration, the baseline random error is reduced by a factor of 2.5–3 compared to the default calibration, and a 5% charge measurement precision is achieved in 15 fC charge injection tests.

Fu, Tao [Unlisted, US]↗