Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A Rapid Method for Quantification OF 242Pu in Urine Using Extraction Chromatography and ICP-MS

Occupational exposure to plutonium is generally monitored through analysis of urine samples. Typically, plutonium is separated from the sample and other actinides, and the concentration is determined using alpha spectroscopy. Current methods for separations and analysis are lengthy and require long count times. A new method for monitoring occupational exposure levels of plutonium has been developed, which requires fewer steps and overall less time than the alpha spectroscopy method. In this method, the urine is acidified, and a 239 Pu internal standard is added. The urine is digested in a microwave oven, and plutonium is separated using an Eichrom TRU Resin column. The plutonium is eluted, and the eluant is injected directly into the Inductively Coupled Plasma–Mass Spectrometer (ICP-MS). Compared to a direct “dilute and shoot” method, a 30-fold improvement in sensitivity is achieved. This method was validated by analyzing several batches of spiked samples. Based on these analyses, a combined standard uncertainty plot, which relates uncertainty to concentration, was produced. As a result, the MDA 95 was calculated to be 7.0 × 10 –7 μg L –1 , and the Lc95 was calculated to be 3.5 × 10 –7 μg L –1 for this method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detection and confirmation of fentanyls in high clay‐content soil by electron ionization gas chromatography‐mass spectrometry

Abstract Detection of illicit drugs in the environment, particularly in soils, often suggests the present or past location of a clandestine production center for these substances. Thus, development of efficient methods for the analysis and detection of these chemicals is of paramount importance in the field of chemical forensics. In this work, a method involving the extraction and retrospective confirmation of fentanyl, acetylfentanyl, thiofentanyl, and acetylthiofentanyl using trichloroethoxycarbonylation chemistry in a high clay‐content soil is presented. The soil was spiked separately with each fentanyl at two concentrations (1 and 10 μg/g) and their extraction accomplished using ethyl acetate and aqueous NH 4 OH (pH ~ 11.4) with extraction recoveries ranging from ~56% to 82% for the high‐concentration (10 μg/g) samples while ranging from ~68% to 83% for the low‐concentration (1 μg/g) samples. After their extraction, residues containing each fentanyl were reacted with 2,2,2‐trichloroethoxycarbonyl chloride (Troc‐Cl) to generate two unique and predictable products from each opioid that can be used to retrospectively confirm their presence and identity using EI‐GC‐MS. The method's limit of detection (MDL/LOD) for Troc‐norfentanyl and Troc‐noracetylfentanyl were estimated to be 29.4 and 31.8 ng/mL in the organic extracts. In addition, the method's limit of quantitation for Troc‐norfentanyl and Troc‐noracetylfentanyl were determined to be 88.2 and 95.5 ng/mL, respectively. Collectively, the results presented herein strengthen the use of chloroformate chemistry as an additional chemical tool to confirm the presence of these highly toxic and lethal substances in the environment.

Valdez, Carlos A.↗

Analytical method for the determination of organic acids in dilute acid pretreated biomass hydrolysate by liquid chromatography-time-of-flight mass spectrometry

For the development of lignocellulosic biofuels a common strategy to release hemicellulosic sugars and enhance the enzymatic digestibility of cellulose is the heat pretreatment of biomass with dilute acid. During this process, fermentation inhibitors such as 5-hydroxymethylfurfural, furfural, phenolics, and organic acids are formed and released into the so-called hydrolysate. The phenolic inhibitors have been studied fairly extensively, but fewer studies have focused on the analysis of the organic acids profile. For this purpose, a simple and fast liquid chromatography/mass spectrometry (LC/MS) method for the analysis of organic acids in the hydrolysate has been developed using an ion exchange column based on a polystyrene-divinylbenzene polymer frequently used in biofuel research. The application of the LC/MS method to a hydrolysate from Miscanthus has been evaluated.

Biotechnology & Applied Microbiology↗

Carbon dioxide (CO2) flux, amplicon sequencing and liquid chromatography–mass spectrometry (LC-MS) data for pyrogenic organic matter (PYOM) amended soil incubations in lab, Madison, WI, 2021-22

This dataset comprises soil-pyrogenic organic matter (PyOM) incubation experiments conducted in a laboratory setting. The focus was on measuring carbon dioxide (CO2) flux emitted in the headspace of incubation jars over a one-month period. The aim was to estimate carbon mineralization from two different carbon fractions in PyOM, as well as carbon mineralization from soil organic carbon (SOC). Bacterial and fungal community profiles were tracked at various time points during the incubation to observe changes in the overall community and specific responders to PyOM. LC-MS analysis of soil samples was also performed to monitor changes in the soil's chemical composition.The provided dataset includes processed CO2 flux measurements obtained from the Picarro-multiplexer measurement setup for each sample incubation jar. This data is available in the "CO2Flux.csv" file. Additionally, the dataset includes CO2 flux data partitioned to estimate mean carbon mineralization from the two PyOM carbon fractions, bulk PyOM, and SOC. The cumulative carbon mineralization data is provided in "cml_respired.csv," while the rate of carbon mineralization data is in "rate_respired.csv." The file "cml_respired_lastcyc.csv" contains cumulative carbon mineralization data for the PyOM carbon fractions, bulk PyOM, and SOC throughout the entire incubation period.For the LC-MS analysis, the raw data can be found in the "20220721_NZ_PeakHeights_FinalAnalysis.csv" file, while sample metadata is provided in "20220721_NZpilot_Metadata.csv". Processed LC-MS data is available in the file "20220721_NZ_FINAL_msdat_sub3.csv". Lastly, the dataset includes the relative abundance data for bacterial genera that exhibited a significant positive response to the addition of PyOM produced at 350 degrees Celsius, which can be found in "resp_genera_350.csv".

54 ENVIRONMENTAL SCIENCES↗

Final summarizing report on Grant DE-SC0001014 "Separation of Highly Complex Mixtures by Two-dimension Liquid Chromatography"

The goal of our research was a fundamental investigation of methods available for the coupling of two separate chromatographic separations that would considerably enhance the individual separation power of each of these two separations. This gain arises from the combination of two independent retention mechanisms, one of them separating the components that coelute on the other column, making possible the separation of many more compounds in a given time. The two separation mechanisms used must be very different. This is possible because many retention mechanisms are available, using different kinds of molecular interactions, hydrophobic or hydrophilic interactions, polar interactions, hydrogen bonding, complex formation, ionic interactions, steric exclusion. Two methods can be used, allowing separations to be performed in space (spreading the bands of sample components on a plate covered with stationary phase layer) or in time (eluting the sample components through a column and detecting the bands leaving the column). Both offer a wide variety of possible combinations and were studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developments in ICP-MS: electrochemically modulated liquid chromatography for the clean-up of ICP-MS blanks and reduction of matrix effects by flow injection ICP-MS

The focus of this dissertation is the development of techniques with which to enhance the existing abilities of inductively coupled plasma mass spectrometry (ICP-MS). ICP-MS is a powerful technique for trace metal analysis in samples of many types, but like any technique it has certain strengths and weaknesses. Attempts are made to improve upon those strengths and to overcome certain weaknesses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RAPID: The Development and Application of a Hybrid High Pressure Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry Method for the Direct Analysis of Irradiated Materials

RAPID (Rapid Analysis of Post-Irradiation Debris) is an automated online separation–direct analysis method developed at Oak Ridge National Laboratory (ORNL) to measure both radioactive and stable fission isotopes by mass. Developed to measure the concentration and isotopic composition of over 40 elements down to the femtogram level, RAPID demonstrates the sensitivity, stability, and precision required to achieve accurate, low-level analyses of elements of non-natural origin. The application of the RAPID method to silica- and soil-based matrices achieved complete matrix exclusion and direct online analysis of the elementally separated analytes, yielding precise isotopic compositions. When combined with isotope dilution, this approach yielded elemental concentrations with low uncertainties, providing a rapid analytical method that encompasses group I and II metals, transition metals, refractory metals, platinum group metals, lanthanides, and actinides. The robustness, sensitivity, reproducibility, and numerous applications to a number of fields in nuclear measurements have been confirmed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗