Infrared characterized spacecraft contaminants and related compounds

The limits of the infrared region of the electromagnetic spectrum are discussed, together with an explanation of some of the shortcomings of obtaining data in this range. Similarities and differences in the interest taken by the chemist/spectroscopist and the space/spectroscopist in the IR spectrum are discussed. The chemist uses IR spectra to identify materials and contaminants associated with spacecraft fabrication and testing. The space scientist, using IR spectrometry, can determine atmospheric conditions around planets, stars, and galaxies. He could also determine the temperature profile of the Earth's atmosphere at different altitudes, or even the temperature profile of the Sun. The importance of detecting contamination of spacecraft and the possible results of not taking corrective action are explored. All space experiments contain some contaminants, to a lesser or greater degree; the responsible personnel involved must determine the level of toleration. A collection of IR spectra of known spacecraft contaminants is presented as a guide for cognizant scientists and engineers.

Gross, F. C.↗

Optical contamination - Its prevention in the XUV spectrographs flown by the U.S. Naval Research Laboratory in the Apollo Telescope Mount

During construction and testing of the XUV spectrographs flown in the ATM by the Naval Research Laboratory, many problems associated with optical contamination were encountered. Solving these problems required setting up a contamination prevention program to select the materials used in constructing the instruments and to delineate procedures in assembling, testing, and storing the instruments. A brief description is given of methods of assessing the effects of contamination and of the procedures used to prevent contamination.

Hunter, W. R.↗

Small monopropellant thruster contamination measurement in a high-vacuum low-temperature facility

The contamination that results from the exhaust plume of small thrusters used for attitude control maneuvers can pose severe problems for long-life satellite systems. In order to assess this type of contamination problem, analytical and experimental techniques must be developed. Mass deposition rate measurements of a representative 0.44-N thrust hydrazine thruster were made in a space simulation chamber using five appropriately placed variable-temperature quartz crystal microbalances. The mass deposition rates within the thruster plume were measured while operating the thruster over a wide range of operating parameters, including duty cycles, catalyst bed start temperatures, propellant water variation, as well as thruster aging effects. The contamination measurements were made over a temperature range of 144 to 256 K for all duty cycles. In addition, the nominal duty cycle of 100 msec on and 10 sec off was run at a temperature of 106 K. These data will make possible better prediction of deposition rates of contaminants from thrusters used in satellite systems.

Passamaneck, R. S.↗

Development of a preprototype trace contaminant control system

The steady state contaminant load model based on shuttle equipment and material test programs, and on the current space station studies was revised. An emergency upset contaminant load model based on anticipated emergency upsets that could occur in an operational space station was defined. Control methods for the contaminants generated by the emergency upsets were established by test. Preliminary designs of both steady state and emergency contaminant control systems for the space station application are presented.

Source record↗

Shuttle orbiter - IUS/DSP satellite interface contamination study

The results of a contamination analysis on the Defense Support Program (DSP) satellite during launch and deployment by the Space Transportation System (STS) are presented. Predicted contaminant deposition was also included on critical DSP surfaces during the period soon after launch when the DSP is in the shuttle orbiter bay with the doors closed, the bay doors open, and during initial deployment. Additionally, a six sided box was placed at the spacecraft position to obtain directional contaminant flux information for a general payload while in the bay and during deployment. The analysis included contamination sources from the shuttle orbiter, IUS and cradle, the DSP sensor and the DSP support package.

Rantanen, R. O.↗

Monitoring of particulate contamination and background brightness from IECM based instrumentation

Of particular concern to the astronomical community is the effect of Shuttle Transportation System induced contamination in the form of individual particles and general background on astronomical experiments. In an effort to investigate this problem, two camera/photometers in the Induced Environment Contamination Monitor (IECM) will be used to determine the size and velocity distribution of contaminant particles, their origin, and the extent of sunlit background brightness resulting from spacecraft contamination. The cameras will operate synchronously as a stereo pair to make continuous photographic measurements throughout the missions.

Clifton, K. S.↗

Effects of carbon/graphite fiber contamination on high voltage electrical insulation

The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.

Garrity, T.↗

Abatement of gaseous and particulate contamination in a space instrument application to a solar telescope

Methods to prevent the ingestion of external contaminants into the instrument and to limit the effect of the self-generated contaminants during ground, launch, orbiting and landing phases of flight were investigated. It is proposed that a positive pressure and purging flow of clean gas inside the instrument be maintained while on the ground, during launch, and for a period of time in orbit. The pressure to be maintained and the required purging flow are examined in terms of the effectiveness in preventing gaseous and particulate contaminants ingestion and the abatement of the self-generated contaminants. Considerations have been given to the venting requirements for the structural integrity of the instrument during launch, the limitations on the volume and the pressure of the purging gas to be carried along in orbit, and the required venting area is established based on the internal volume of the instrument, the allowable pressure differential, and the rate of external pressure change during launch.

Scialdone, J. J.↗

Shuttle payload integration - Contamination aspects

As part of the development of the Space Shuttle, a payload integration system has been established. This integration system or process encompasses several technical disciplines, one of which is concerned with the control of molecular and particulate contamination. Specific integration procedures and documentation have evolved that reflect the incorporation of payload/Space Transportation System contamination requirements and capabilities. Of the 38 payloads in the payload integration system currently, about 20% are considered sensitive to contamination in that special precautions must be taken to ensure that contamination from the Space Shuttle Orbiter does not impair payload function. Most of these payload requirements have been satisfied by the incorporation of controlled ground operations discipline and installation of a payload bay liner, which isolates the payload from the Orbiter systems. Some payloads, however, provide covers for sensitive payload instrumentation.

Jacobs, S.↗

Abatement of gaseous and particulate contamination in a space instrument

Methods to prevent the ingestion of external contaminants into the instrument and to limit the effect of the self-generated contaminants during ground, launch, orbiting and landing phases of flight were investigated. It is proposed that a positive pressure and purging flow of clean gas inside the instrument be maintained while on the ground, during launch, and for a period of time in orbit. The pressure to be maintained and the required purging flow are examined in terms of the effectiveness in preventing gaseous and particulate contaminants ingestion and the abatement of the self-generated contaminants. Considerations have been given to the venting requirements for the structural integrity of the instrument during launch, the limitations on the volume and the pressure of the purging gas to be carried along in orbit, and the required venting area is established based on the internal volume of the instrument, the allowable pressure differential, and the rate of external pressure change during launch. Previously announced in STAR as N83-23350

Scialdone, J. J.↗

Optical contamination on the Atmosphere Explorer-E satellite

Atmospheric optical emission measurements by the Visible Airglow Experiment (VAE) on board the Atmosphere Explorer (AE-C, D and E) satellites have been analyzed and found to be contaminated at low altitudes. The contamination maximizes in the forward direction along the spacecraft velocity and is sensitive to the composition and density of the ambient atmosphere. Analysis at two different wavelengths suggests that the contamination is likely to have a diffuse band spectrum which is brighter toward the red. Some unknown processes which involve satellite surface materials and the incoming ambient particles are believed to be responsible for the contamination. A simulation model is presented here to account for the observed angular dependence.

Yee, J. H.↗

Maintenance of contamination sensitive surfaces on board long-term space vehicles

In the current age, highly sensitive instruments are being flown on spacecraft, and questions of contamination have become important. The present investigation is concerned with the available approaches which can provide long-term protection for contamination sensitive surfaces. Aspects and sources of spacecraft contamination are examined, taking into account materials outgassing, particulates, propulsion system interaction, overboard venting, man-made and cosmic debris, and atomic oxygen/ambient atmosphere interaction. Suitable protection approaches provided by current technology are discussed, giving attention to aperture covers, a possibility for a retractable cover design, gaseous purges, options for prolonging the lifetime of the thermal control system, and plume shields. Some new possibilities considered are related to an early warning system for excessive amounts of contamination, a molecular/wake shield, and the use of atomic oxygen.

Phillips, A.↗

Shuttle on-orbit contamination and environmental effects

Ensuring the compatibility of the space shuttle system with payloads and payload measurements is discussed. An extensive set of quantitative requirements and goals was developed and implemented by the space shuttle program management. The performance of the Shuttle system as measured by these requirements and goals was assessed partly through the use of the induced environment contamination monitor on Shuttle flights 2, 3, and 4. Contamination levels are low and generally within the requirements and goals established. Additional data from near-term payloads and already planned contamination measurements will complete the environment definition and allow for the development of contamination avoidance procedures as necessary for any payload.

Leger, L. J.↗

A review of contamination issues associated with an orbiting Space Station external environment

Techniques for measuring, modeling, and limiting the effluent contamination of external spacecraft and instrument surfaces are reviewed, with an emphasis on their application to the Space Station. The major factors addressed by contamination studies are outlined; typical contamination sources are characterized; the critical measurement parameters are defined (molecular column density, background spectral intensity from UV to IR, particle size and velocity distribution, molecular deposition on ambient and cryogenic surfaces, molecular return flux for gaseous species, particulate deposition on surfaces, and optical-surface degradation); and measurement instrumentation is described. Contamination limits for quiescent operation periods of the Space Station are proposed, including column density 10 to the 11th/sq cm for H2O + CO2, 10 to the 13th/sq cm for O2 + N2, and 10 to the 10th/sq cm for other species; particle release no greater than 15-micron particle/orbit/0.00001 sr FOV for a 1-m telescope, and surface deposition 4 pg/sq cm sec for 298-K surfaces and 10 pg/sq cm sec for 4-K surfaces.

Smith, A. C.↗

Airborne trace contaminants of possible interest in CELSS

One design goal of Closed Ecological Life Support Systems (CELSS) for long duration space missions is to maintain an atmosphere which is healthy for all the desirable biological species and not deleterious to any of the mechanical components in that atmosphere. CELESS design must take into account the interactions of at least six major components; (1) humans and animals, (2) higher plants, (3) microalgae, (4) bacteria and fungi, (5) the waste processing system, and (6) other mechanical systems. Each of these major components can be both a source and a target of airborne trace contaminants in a CELSS. A range of possible airborne trace contaminants is discussed within a chemical classification scheme. These contaminants are analyzed with respect to their probable sources among the six major components and their potential effects on those components. Data on airborne chemical contaminants detected in shuttle missions is presented along with this analysis. The observed concentrations of several classes of compounds, including hydrocarbons, halocarbons, halosilanes, amines and nitrogen oxides, are considered with respect to the problems which they present to CELSS.

Garavelli, J. S.↗

Sr, Nd, and Pb isotopes in Proterozoic intrusives astride the Grenville Front in Labrador - Implications for crustal contamination and basement mapping

Trace element and Pb, Sr, and Nd isotopic compositions of anorthosites and related rocks, and of younger mafic dikes from Harp Lake and Mealy Mountains in Labrador, Canada are estimated and compared. The effects of crustal component contaminants on the isotopic compositions of the dikes are investigated. The correlation between the isotopic data and the crustal contamination model is studied. It is observed that for Harp Lake the initial Sr ratios are higher and the Nd values are lower than Mealy samples, and the data do not correspond to the crustal contamination model; however, the Pb isotope data favor a crustal contamination model. It is noted that the Labrador segment of the Grenville Front appears to coincide with the southern margin of the Archean North Atlantic craton, and may represent a pre mid-Proterozoic suture.

Ashwal, L. D.↗

Effects of varying environmental parameters on trace contaminant concentrations in the NASA Space Station Reference Configuration

An evaluation is made of the NASA Space Station Reference Configuration trace contaminant production and depletion level effects of CO2, O2, humidity, temperature, and pressure variations, on the basis of a computer model of the Reference Configuration's chemical reactions and physical processes as functions of time. The effects of changes in the initial concentrations of such contaminants as nonmethane hydrocarbons and nitrogen oxides are also examined, and these are found to result in more significant changes in the concentration levels of trace contaminants than pressure and humidity variations. O2 and CO2 changes are found to have negligible effects on trace contaminant concentrations.

Brewer, Dana A.↗

A simulation model for the analysis of Space Station gas-phase trace contaminants

A simulation model for the analysis of gas-phase trace contaminants in the cabin air of the NASA Space Station Reference Configuration was developed at the NASA Langley Research Center. The model predicts changes in trace contaminant concentrations from both physical and chemical sources and sinks as a function of time. Simulations were performed in which values for relative humidity, temperature, radiation intensity, pressure, and initial species concentrations were constrained to values for these parameters measured and modeled in the continental tropics at the earth's surface. Species concentrations simulated using the model compared favorably with concentrations in the continental tropics which demonstrated that the chemical mechanism in the trace contaminant model approximates changes in atmospheric species concentrations. The sensitivity of initial species concentrations to producing changes in additional species concentrations was also assessed. Results from the model indicated that chemical reactions will be important in determining the composition of cabin air in the Space Station. It is anticipated that the trace contaminant model will be useful in assessing the impact of experiments and commercial operations on the composition of the cabin air in the Space Station.

Brewer, Dana A.↗