Wide field array calibration dependence on the stability of measured dose distributions

Purpose: The aim of this work was to simulate the effect of dose distribution changes on detector array calibrations and to explore compensatory methods that are used during calibration measurements. Methods: The array calibration technique that was investigated is known as wide field (WF) calibration. Using this method, a linear array [y-axis (65 detectors) of the IC PROFILER (Sun Nuclear Corporation, Melbourne, FL)] is calibrated with three measurements ({alpha}, {theta}, and {lambda}); each measurement uses the same radiation field, which is larger than the array. For measurement configuration {theta}, the array is rotated by 180 deg. from its position in {alpha}; for {lambda}, the array is shifted by one detector from its position in {theta}. The relative detector sensitivities are then determined through ratios of detector readings at the same field locations (using {theta} and {lambda}). This method results in error propagation that is proportional to the number of detectors in the array. During the procedure, the calibration protocol operates under three postulates, which state that (a) the beam shape does not change between measurements; (b) the relative sensitivities of the detectors do not change; and (c) the scatter to the array does not change as the array is moved. The WF calibration's sensitivity to a postulate (a) violation was quantified by applying a sine shaped perturbation (of up to 0.1%) to {alpha}, {theta}, or {lambda}, and then determining the change relative to a baseline calibration. Postulate (a) violations were minimized by using a continuous beam and mechanized array movement during {theta} and {lambda}. A continuously on beam demonstrated more stable beam symmetry as compared to cycling the beam on and off between measurements. Additional side-scatter was also used to satisfy postulate (c). Results: Simulated symmetry perturbations of 0.1% to {theta} or {lambda} resulted in calibration errors of up to 2%; {alpha} was relatively immune to perturbation (<0.1% error). Wide field calibration error on a linear accelerator with similar symmetry variations was {+-}1.6%. Using a continuous beam during {theta} and {lambda} with additional side-scatter reduced the calibration error from {+-}1.6% to {+-}0.48%. Conclusions: This work increased the reproducibility of WF calibrations by limiting the effect of measurement perturbations primarily due to linear accelerator symmetry variations. The same technique would work for any array using WF calibration.

60 APPLIED LIFE SCIENCES↗

Bayesian Treed Calibration: An Application to Carbon Capture With AX Sorbent

In cases where field or experimental measurements are not available, computer models can model real physical or engineering systems to reproduce their outcomes. They are usually calibrated in light of experimental data to create a better representation of the real system. Statistical methods, based on Gaussian processes, for calibration and prediction have been especially important when the computer models are expensive and experimental data limited. In this paper, we develop the Bayesian treed calibration (BTC) as an extension of standard Gaussian process calibration methods to deal with non-stationarity computer models and/or their discrepancy from the field (or experimental) data. Our proposed method partitions both the calibration and observable input space, based on a binary tree partitioning, into sub-regions where existing model calibration methods can be applied to connect a computer model with the real system. The estimation of the parameters in the proposed model is carried out using Markov chain Monte Carlo (MCMC) computational techniques. Different strategies have been applied to improve mixing. We illustrate our method in two artificial examples and a real application that concerns the capture of carbon dioxide with AX amine based sorbents. The source code and the examples analyzed in this paper are available as part of the supplementary materials.

Bayesian tree↗

Estimating Am-241 activity in the body: comparison of direct measurements and radiochemical analyses

The assessment of dose and ultimately the health risk from intakes of radioactive materials begins with estimating the amount actually taken into the body. An accurate estimate provides the basis to best assess the distribution in the body, the resulting dose, and ultimately the health risk. This study continues the time-honored practice of evaluating the accuracy of results obtained using in vivo measurement methods and techniques. Results from the radiochemical analyses of the 241Am activity content of tissues and organs from four donors to the United States Transuranium and Uranium Registries were compared to the results from direct measurements of radioactive material in the body performed in vivo and post mortem. Two were whole body donations and two were partial body donations The skeleton was the organ with the highest deposition of 241Am activity in all four cases. The activities ranged from 30 Bq to 300 Bq. The skeletal estimates obtained from measurements over the forehead were within 20% of the radiochemistry results in three cases and differed by 78% in one case. The 241Am lung activity estimates ranged from 1 Bq to 30 Bq in the four cases. The results from the direct measurements were within 40% of the radiochemistry results in 3 cases and within a factor of 3 for the other case. The direct measurement estimates of liver activity ranged from 2 Bq to 60 Bq and were generally lower than the radiochemistry results. The results from this study suggest that the measurement methods and calibration techniques used at the In Vivo Radiobioassay and Research Facility to quantify the activity in the lungs, skeleton and liver are reasonable under the most challenging conditions where there is 241Am activity in multiple organs. These methods and techniques are comparable to those used at other Department of Energy sites. This suggests that the current in vivo methods and calibration techniques provide reasonable estimates of radioactive material in the body. Not unexpectedly, there can be significant uncertainty in the estimates especially when activity is also present in other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially uniform calibration of a liquid xenon detector at low energies using {sup 83m}Kr

A difficult task with many particle detectors focusing on interactions below {approx}100 keV is to perform a calibration in the appropriate energy range that adequately probes all regions of the detector. Because detector response can vary greatly in various locations within the device, a spatially uniform calibration is important. We present a new method for calibration of liquid xenon (LXe) detectors, using the short-lived {sup 83m}Kr. This source has transitions at 9.4 and 32.1 keV, and as a noble gas like Xe, it disperses uniformly in all regions of the detector. Even for low source activities, the existence of the two transitions provides a method of identifying the decays that is free of background. We find that at decreasing energies, the LXe light yield increases, while the amount of electric field quenching is diminished. Additionally, we show that if any long-lived radioactive backgrounds are introduced by this method, they will present less than 67x10{sup -6} events kg{sup -1} day{sup -1} keV{sup -1} in the next generation of LXe dark matter direct detection searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-65: Prediction of Patient Setup Errors and Errors in the Calibration Curve from Prompt Gamma Proton Range Measurements

Purpose: To understand the extent to which the prompt gamma camera measurements can be used to predict the residual proton range due to setup errors and errors in the calibration curve. Methods: We generated ten variations on a default calibration curve (CC) and ten corresponding range maps (RM). Starting with the default RM, we chose a square array of N beamlets, which were then rotated by a random angle θ and shifted by a random vector s. We added a 5% distal Gaussian noise to each beamlet in order to introduce discrepancies that exist between the ranges predicted from the prompt gamma measurements and those simulated with Monte Carlo algorithms. For each RM, s, θ, along with an offset u in the CC, were optimized using a simple Euclidian distance between the default ranges and the ranges produced by the given RM. Results: The application of our method lead to the maximal overrange of 2.0mm and underrange of 0.6mm on average. Compared to the situations where s, θ, and u were ignored, these values were larger: 2.1mm and 4.3mm. In order to quantify the need for setup error corrections, we also performed computations in which u was corrected for, but s and θ were not. This yielded: 3.2mm and 3.2mm. The average computation time for 170 beamlets was 65 seconds. Conclusion: These results emphasize the necessity to correct for setup errors and the errors in the calibration curve. The simplicity and speed of our method makes it a good candidate for being implemented as a tool for in-room adaptive therapy. This work also demonstrates that the Prompt gamma range measurements can indeed be useful in the effort to reduce range errors. Given these results, and barring further refinements, this approach is a promising step towards an adaptive proton radiotherapy.

60 APPLIED LIFE SCIENCES↗

A direct detection method of galaxy intrinsic ellipticity-gravitational shear correlation in non-linear regimes using self-calibration

Intrinsic alignment (IA) of galaxies is a challenging source of contamination in the Cosmic shear (GG) signals. The galaxy intrinsic ellipticity-gravitational shear (IG) correlation is generally the most dominant component of such contamination for cross-correlating redshift bins. One of the most effective techniques to mitigate such contamination is the self-calibration (SC) method which extracts the IG correlation and allows for its removal from the GG signal. In a photometric survey, the SC method first extracts the galaxy number density-galaxy intrinsic ellipticity (gI) correlation from the observed galaxy-galaxy lensing correlation using the redshift dependence of lens-source pairs. The IG correlation is computed through a scaling relation using the gI correlation and other lensing observables. The applicability of the SC method has so far been focused on the linear IA scales and the linear galaxy bias. We extend the SC method beyond the linear regime by modifying its scaling relation which can account for the non-linear galaxy bias model and various IA models. In this study, we provide a framework to detect the IG correlation for the redshift bins for source galaxies for the proposed year 1 survey of the Rubin Legacy Survey of Space and Time (LSST Y1). We tested the method for the tidal alignment and tidal torquing (TATT) model of IA and we found that the scaling relation is accurate within 10% and 20% for cross-correlating and auto-correlating redshift bins, respectively. Hence the suppression of IG contamination in observed GG correlation can be accomplished with a factor of 10 and 5, for cross-correlating and auto-correlating redshift bins, respectively. We tested the method's robustness and found that the suppression of IG contamination by a factor of 5 is still achievable for all combinations of cross-correlating bins even with the inclusion of a moderate amount of uncertainties on IA and bias parameters, respectively. We also make available, a branch of the code FAST-PT to provide gI correlations up to 1-loop order term used by the new SC method.

gravitational lensing↗

AI-assisted detector design for the EIC (AID(2)E)

Artificial Intelligence is poised to transform the design of complex, large-scale detectors like ePIC at the future Electron Ion Collider. Featuring a central detector with additional detecting systems in the far forward and far backward regions, the ePIC experiment incorporates numerous design parameters and objectives, including performance, physics reach, and cost, constrained by mechanical and geometric limits. This project aims to develop a scalable, distributed AI-assisted detector design for the EIC (AID(2)E), employing state-of-the-art multiobjective optimization to tackle complex designs. Supported by the ePIC software stack and using G EANT 4 simulations, our approach benefits from transparent parameterization and advanced AI features. The workflow leverages the PanDA and iDDS systems, used in major experiments such as ATLAS at CERN LHC, the Rubin Observatory, and sPHENIX at RHIC, to manage the compute intensive demands of ePIC detector simulations. Tailored enhancements to the PanDA system focus on usability, scalability, automation, and monitoring. Ultimately, this project aims to establish a robust design capability, apply a distributed AI-assisted workflow to the ePIC detector, and extend its applications to the design of the second detector (Detector-2) in the EIC, as well as to calibration and alignment tasks. Additionally, we are developing advanced data science tools to efficiently navigate the complex, multidimensional trade-offs identified through this optimization process.

97 MATHEMATICS AND COMPUTING↗

Absolute intensity calibration of the Wendelstein 7-X high efficiency extreme ultraviolet overview spectrometer system

The new high effiency extreme ultraviolet overview spectrometer (HEXOS) system for the stellarator Wendelstein 7-X is now mounted for testing and adjustment at the tokamak experiment for technology oriented research (TEXTOR). One part of the testing phase was the intensity calibration of the two double spectrometers which in total cover a spectral range from 2.5 to 160.0 nm with overlap. This work presents the current intensity calibration curves for HEXOS and describes the method of calibration. The calibration was implemented with calibrated lines of a hollow cathode light source and the branching ratio technique. The hollow cathode light source provides calibrated lines from 16 up to 147 nm. We could extend the calibrated region in the spectrometers down to 2.8 nm by using the branching line pairs emitted by an uncalibrated pinch extreme ultraviolet light source as well as emission lines from boron and carbon in TEXTOR plasmas. In total HEXOS is calibrated from 2.8 up to 147 nm, which covers most of the observable wavelength region. The approximate density of carbon in the range of the minor radius from 18 to 35 cm in a TEXTOR plasma determined by simulating calibrated vacuum ultraviolet emission lines with a transport code was 5.5x10{sup 17} m{sup -3} which corresponds to a local carbon concentration of 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-calibration of a cone-beam micro-CT system

Use of cone-beam computed tomography (CBCT) is becoming more frequent. For proper reconstruction, the geometry of the CBCT systems must be known. While the system can be designed to reduce errors in the geometry, calibration measurements must still be performed and corrections applied. Investigators have proposed techniques using calibration objects for system calibration. In this study, the authors present methods to calibrate a rotary-stage CB micro-CT (CB{mu}CT) system using only the images acquired of the object to be reconstructed, i.e., without the use of calibration objects. Projection images are acquired using a CB{mu}CT system constructed in the authors' laboratories. Dark- and flat-field corrections are performed. Exposure variations are detected and quantified using analysis of image regions with an unobstructed view of the x-ray source. Translations that occur during the acquisition in the horizontal direction are detected, quantified, and corrected based on sinogram analysis. The axis of rotation is determined using registration of antiposed projection images. These techniques were evaluated using data obtained with calibration objects and phantoms. The physical geometric axis of rotation is determined and aligned with the rotational axis (assumed to be the center of the detector plane) used in the reconstruction process. The parameters describing this axis agree to within 0.1 mm and 0.3 deg with those determined using other techniques. Blurring due to residual calibration errors has a point-spread function in the reconstructed planes with a full-width-at-half-maximum of less than 125 {mu}m in a tangential direction and essentially zero in the radial direction for the rotating object. The authors have used this approach on over 100 acquisitions over the past 2 years and have regularly obtained high-quality reconstructions, i.e., without artifacts and no detectable blurring of the reconstructed objects. This self-calibrating approach not only obviates calibration runs, but it also provides quality control data for each data set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radiation quality correction factor k{sub Q} for well-type ionization chambers for the measurement of the reference air kerma rate of {sup 60}Co HDR brachytherapy sources

Purpose: The aim of this study was to investigate whether a chamber-type-specific radiation quality correction factor k{sub Q} can be determined in order to measure the reference air kerma rate of {sup 60}Co high-dose-rate (HDR) brachytherapy sources with acceptable uncertainty by means of a well-type ionization chamber calibrated for {sup 192}Ir HDR sources. Methods: The calibration coefficients of 35 well-type ionization chambers of two different chamber types for radiation fields of {sup 60}Co and {sup 192}Ir HDR brachytherapy sources were determined experimentally. A radiation quality correction factor k{sub Q} was determined as the ratio of the calibration coefficients for {sup 60}Co and {sup 192}Ir. The dependence on chamber-to-chamber variations, source-to-source variations, and source strength was investigated. Results: For the PTW Tx33004 (Nucletron source dosimetry system (SDS)) well-type chamber, the type-specific radiation quality correction factor k{sub Q} is 1.19. Note that this value is valid for chambers with the serial number, SN ≥ 315 (Nucletron SDS SN ≥ 548) onward only. For the Standard Imaging HDR 1000 Plus well-type chambers, the type-specific correction factor k{sub Q} is 1.05. Both k{sub Q} values are independent of the source strengths in the complete clinically relevant range. The relative expanded uncertainty (k = 2) of k{sub Q} is U{sub k{sub Q}} = 2.1% for both chamber types. Conclusions: The calibration coefficient of a well-type chamber for radiation fields of {sup 60}Co HDR brachytherapy sources can be calculated from a given calibration coefficient for {sup 192}Ir radiation by using a chamber-type-specific radiation quality correction factor k{sub Q}. However, the uncertainty of a {sup 60}Co calibration coefficient calculated via k{sub Q} is at least twice as large as that for a direct calibration with a {sup 60}Co source.

60 APPLIED LIFE SCIENCES↗

The CMS Phase-1 Pixel Detector Upgrade

The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation and Optimizing Groundwater Investigations, Conceptual Design Analysis, Model Calibration and Remedial Design Using Parallel Numerical Methods: Theory and Application - 16578

Optimization of environmental restoration efforts at complex groundwater sites involves the development of a conceptual and often numerical flow and transport models. Typically, a limited number of simulations are done to assess the impact of parameter uncertainty, to evaluate remedial alternatives and develop a remedy, or to modify an existing remedy. A limited number of simulations are performed because each simulation can take upwards of several hours per simulation and until now the ability to conduct the 100's to 1000's of simulations needed to derive an optimal remedy was beyond the reach of the everyday practitioner. HGL has developed and implemented new parallel simulation and optimization methods in their software and has successfully deployed applications on high performance Cloud-based computing platforms. This advancement removes the impediment of burdensome and unpredictable runtime requirements these types of projects have typically exhibited using heuristic trial-and-error or even automated serial computation approaches. A parallel numerical solver has been added to the subsurface flow and transport simulator MODFLOW-SURFACT{sup TM} and has demonstrated reductions in solution time by as much as a factor of 9.8. This is accomplished by distributing the numerical computations of every time step over multiple processors. The integrated parallel simulation and optimization method uses the breadth and depth search approach; iteratively producing sets of tens or 100's of candidate solutions that are evaluated concurrently instead sequentially (i.e. one model evaluation at a time). Solutions within 80-100% of the globally optimal solution are regularly found expending only 5-10% of the usual computational effort using this new parallel optimization method (reducing computation effort by 10 to 20 times). Distributing optimal search runs across multiple processors additionally reduces calendar time to solutions. Practitioners evaluating multiple conceptual site models, model calibration by auto-calibration methods and remedial design by heuristics can enjoy significant reductions in model solution time by using the parallel numerical matrix solver in the physics-based simulator. Combining investigation and design analysis with breadth and depth parallel optimization methods, projects at the fringe of practical optimization, along with projects that were beyond the reach of formal optimization methods are now wholly feasible and tractable optimization problems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clumped 13 CH 2 D and 12 CHD 2 compositions of methyl groups from wood and synthetic monomers: Methods, experimental and theoretical calibrations, and initial results

Methyl groups are found in numerous biogenic and synthetic materials including geologically preserved materials such as wood. The carbon and hydrogen isotope compositions of methyl groups are used as tracers in biogeochemical cycles, as paleothermometers, and to determine the hydrogen isotopic composition of ancient rain. Here we present analyses of resolved 13 C–D ( 13 CH 2 D) and D–D ( 12 CHD 2 ) clumped isotope compositions of methyl groups as new variables for the study of methyl groups in the present and past. We first present chemical methods to extract, purify, and derivatize methyl groups from methoxyl (R–O–CH 3 ) groups as CH 3 F and CH 3 Cl, and high-resolution mass spectrometric techniques to determine the clumped isotope compositions of these species. We achieve precisions for 13 C–D clumping of ±0.25‰ and D–D clumping of ±2.5‰. We anchor our clumped isotopic measurements to a thermodynamic reference frame by first calculating the theoretical temperature dependences of 13 C–D and D–D clumping in CH 3 Cl, then placing our measurements onto this reference frame through experimental internal isotopic equilibration of CH 3 Cl at 200 °C. Finally, we provide and analyze an initial dataset of clumped 13 C–D and D–D compositions of methyl groups from various commercial/synthetic monomers and environmental woods. We observe ranges in clumped isotope compositions of ~11‰ in 13 C–D and ~48‰ in D–D, and systematic differences within these ranges between methyl groups from commercial monomers and wood. Specifically, commercial clumped 13 C–D compositions are between 0 and 3‰, which correspond to apparent equilibrium temperatures between 170 °C and the infinite temperature limit. In contrast, the clumped 13 C–D compositions of wood methoxyl groups are distinctively high (9.50–11.25‰) and 3–6‰ higher than would be expected if formed in internal isotopic equilibrium at Earth-surface temperatures. Commercial/synthetic methyl and wood methoxyl clumped D–D compositions are also distinct: -5 to +13‰ in commercial monomers vs. -35 to -8‰ in wood—such negative values cannot result from formation in isotopic equilibrium and require kinetic processes to have occurred. Overall, these results indicate that wood methoxyl groups are formed out of isotopic equilibrium and that clumped isotope compositions of methyl groups may be useful tracers of methyl group sources and sinks in the environment. For instance, isotopic clumping in methyl groups may be useful for understanding controls on isotopic clumping in methane produced by methylotrophic methanogens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Calibration of Gamma Spectra in Plastic Scintillators using Compton Kinematics

This paper describes a simple and practicable method for assigning energy values to gamma-ray pulse-height distributions measured with polyvinyl toluene based detectors. It is based upon the characteristic shape of the spectrum in the region of maximum energy deposition resulting from a single Compton scattering. The validity of this method is first demonstrated by applying it to a set of NaI(Tl) spectra, and comparing those results to the standard photo-peak method of calibrating the same spectra. The method is then applied to a set of polyvinyl toluene derived spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of spherical reference surfaces for Fizeau interferometry: a comparative study of methods

We present an experimental study of three calibration methods for spherical reference surfaces in Fizeau interferometry. The ball average, which relies on averaging measurements of a test ball surface over sufficiently many random rotations of the ball, is theoretically an absolute technique but can be very laborious. On the other hand, a recently introduced double-pass technique, comparing the two halves of the reference surface, is able to determine the point-symmetric contribution in as few as three measurements but does not detect the point-antisymmetric portion. Finally, the point-symmetric errors of the reference surface can be captured in a single, so-called ''cat's-eye'' measurement. Our study tries to answer the question of which of the techniques is preferable in practice. We find that the answer depends on the required uncertainty, and it appears that the new double-pass technique represents a practical and reasonable trade-off between expediency and accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

Evaluation of B/A nonlinear parameter using an acoustic self-calibrated pulse-echo method

The objective of this work is to develop an easy-to-build and robust setup for measuring the nonlinearity parameter B/A in fluids using ultrasound. The method is based on the pulse-echo technique, using a single element broadband acoustic transducer, and requires electrical signal measurements. Results obtained in water and denatured alcohol validate the proposed procedure. The choice of a suitable primary wave frequency is discussed with regard to the transducer sensitivity. Further, the influence of the perturbations introduced by the experimental device nonlinearities, and the role of the reflector on the measured second harmonic field amplitude are investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-F-18A-03: Improving Tissue Segmentation for Monte Carlo Dose Calculation Using DECT Data

Purpose: To develop a new segmentation technique using dual energy CT (DECT) to overcome limitations related to segmentation from a standard Hounsfield unit (HU) to electron density (ED) calibration curve. Both methods are compared with a Monte Carlo analysis of dose distribution. Methods: DECT allows a direct calculation of both ED and effective atomic number (EAN) within a given voxel. The EAN is here defined as a function of the total electron cross-section of a medium. These values can be effectively acquired using a calibrated method from scans at two different energies. A prior stoichiometric calibration on a Gammex RMI phantom allows us to find the parameters to calculate EAN and ED within a voxel. Scans from a Siemens SOMATOM Definition Flash dual source system provided the data for our study. A Monte Carlo analysis compares dose distribution simulated by dosxyz-nrc, considering a head phantom defined by both segmentation techniques. Results: Results from depth dose and dose profile calculations show that materials with different atomic compositions but similar EAN present differences of less than 1%. Therefore, it is possible to define a short list of basis materials from which density can be adapted to imitate interaction behavior of any tissue. Comparison of the dose distributions on both segmentations shows a difference of 50% in dose in areas surrounding bone at low energy. Conclusion: The presented segmentation technique allows a more accurate medium definition in each voxel, especially in areas of tissue transition. Since the behavior of human tissues is highly sensitive at low energies, this reduces the errors on calculated dose distribution. This method could be further developed to optimize the tissue characterization based on anatomic site.

60 APPLIED LIFE SCIENCES↗