Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparison study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

60 APPLIED LIFE SCIENCES↗

Vertically Aligned Carbon Nanofiber based Biosensor Platform for Glucose Sensor

Vertically aligned carbon nanofibers (VACNFs) have recently become an important tool for biosensor design. Carbon nanofibers (CNF) have excellent conductive and structural properties with many irregularities and defect sites in addition to exposed carboxyl groups throughout their surfaces. These properties allow a better immobilization matrix compared to carbon nanotubes and offer better resolution when compared with the FET-based biosensors. VACNFs can be deterministically grown on silicon substrates allowing optimization of the structures for various biosensor applications. Two VACNF electrode architectures have been employed in this study and a comparison of their performances has been made in terms of sensitivity, sensing limitations, dynamic range, and response time. The usage of VACNF platform as a glucose sensor has been verified in this study by selecting an optimum architecture based on the VACNF forest density. Read More: http://www.worldscientific.com/doi/abs/10.1142/S0129156414500062

Al Mamun, Khandaker A.↗

SU-F-SPS-11: The Dosimetric Comparison of Truebeam 2.0 and Cyberknife M6 Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of Truebeam 2.0 and Cyberknife M6 treatment plans were made. Methods: For Truebeam 2.0 machine, treatment planning were done using 2 full arc VMAT technique with 6 FFF beam on the CT scan of Randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using Eclipse treatment planning system with Acuros XB algorithm. The treatment planning of the same target were also done for Cyberknife M6 machine with Multiplan treatment planning system using Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For Truebeam plans, the gamma analysis passing rates were 99.1% and 95.5% for target and peripheral region of target respectively. Conclusion: Although, target dose distribution calculated accurately by Acuros XB and Monte Carlo algorithms, Monte carlo calculation algorithm predicts dose distribution around the peripheral region of target more accurately than Acuros algorithm.

60 APPLIED LIFE SCIENCES↗

Conformation and dynamics of ring polymers under symmetric thin film confinement

Understanding the structure and dynamics of polymers under confinement has been of widespread interest, and one class of polymers that have received comparatively little attention under confinement is that of ring polymers. The properties of non-concatenated ring polymers can also be important in biological fields because ring polymers have been proven to be a good model to study DNA organization in the cell nucleus. From our previous study, linear polymers in a cylindrically confined polymer melt were found to segregate from each other as a result of the strong correlation hole effect that is enhanced by the confining surfaces. By comparison, our subsequent study of linear polymers in confined thin films at similar levels of confinements found only the onset of segregation. Here, we use molecular dynamics simulation to investigate the chain conformations and dynamics of ring polymers under planar (1D) confinement as a function of film thickness. Our results show that conformations of ring polymers are similar to the linear polymers under planar confinement, except that ring polymers are less compressed in the direction normal to the walls. While we find that the correlation hole effect is enhanced under confinement, it is not as pronounced as the linear polymers under 2D confinement. Finally, we show that chain dynamics far above Tg are primarily affected by the friction from walls based on the monomeric friction coefficient we get from the Rouse mode analysis.

36 MATERIALS SCIENCE↗

FLUORINE ABUNDANCES IN GALACTIC ASYMPTOTIC GIANT BRANCH STARS

An analysis of the fluorine abundance in Galactic asymptotic giant branch (AGB) carbon stars (24 N-type, 5 SC-type, and 5 J-type) is presented. This study uses the state-of-the-art carbon-rich atmosphere models and improved atomic and molecular line lists in the 2.3 {mu}m region. Significantly lower F abundances are obtained in comparison to previous studies in the literature. This difference is mainly due to molecular blends. In the case of carbon stars of SC-type, differences in the model atmospheres are also relevant. The new F enhancements are now in agreement with the most recent theoretical nucleosynthesis models in low-mass AGB stars, solving the long-standing problem of F in Galactic AGB stars. Nevertheless, some SC-type carbon stars still show larger F abundances than predicted by stellar models. The possibility that these stars are of larger mass is briefly discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

The Significance of Environmental Attributes as Indicators of the Life Cycle Environmental Impacts of Packaging and Food Service Ware

The environmental impacts of packaging and food service ware (FSW) are increasingly the subject of government policy, public discourse, and industry commitments. While some consideration is given to reducing the impacts of packaging across its entire life cycle, most of the focus is on packaging waste or feedstock substitution. Efforts typically focus on specific packaging characteristics, or material attributes, commonly perceived to be environmentally preferable. This article summarizes an extensive meta-review of existing published literature that was performed to determine whether the material attributes recyclability, recycled content, compostability, and biobased, commonly considered to be environmentally beneficial, correlate with lower net environmental impacts across the full life cycle of the packaging and FSW. Seventy-one unique life cycle assessment (LCA) studies that quantify the environmental impacts throughout the entire life cycle of packaging and FSW were analyzed. These studies included over 5000 comparisons for 13 impact categories commonly analyzed in LCA studies. The results from the meta-review identified a number of instances where material attributes do not correlate with environmental benefits for packaging and FSW. Rather, other characteristics such as material choice or mass of the packaging/FSW products can have higher influence in determining life cycle impacts.

54 ENVIRONMENTAL SCIENCES↗

Chemical Preparation, Crystal Structure Reinvestigation and Vibrational Study of CoNa 3 P 3 O 10 ·12H 2 O and X-ray Characterization of the New Anhydrous Triphosphate CoNa 3 P 3 O 10

The triphosphate dodecahydrate of cobalt and sodium CoNa 3 P 3 O 10 ·12H 2 O was prepared by the ion exchange resin process. Its structure was studied by X-ray diffraction and determined in the monoclinic space group P12 1 /c1 with the unit-cell parameters a = 14.6650(5) Å, b=9.1916(3) Å, c = 15.0239(5) Å,β =90.2210(10)°, Z = 4 and V = 2025.13(12) Å 3 . The thermal dehydration of this compound was performed, leading to an anhydrous new form, CoNa 3 P 3 O 10 , which was characterized by X-ray diffraction. The obtained CoNa 3 P 3 O 10 crystallized in monoclinic space group P21/n with the unit-cell parameters a=15,3774 Å, b=7,6988 A°, c=14,2832A°, β=92,9115°. The characteristic IR wavenumbers of the P 3 O 10 5- ions observed in the vibrational spectra were calculated using isotopic substitutions, which confirms the existence of these groups in the studied compound. A comparison between the IR and Raman wavenumbers of CoNa 3 P 3 O 10 ·12H 2 O, CoNa 3 P 3 O 10 and Na 5 P 3 O 10 ·12H 2 was performed. A kinetic study was also made for CoNa 3 P 3 O 10 ·12H 2 O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of today’s dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study

Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models and x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.

60 APPLIED LIFE SCIENCES↗

Towards the development of high temperature comparison artifacts for radiation thermometry

This paper describes the methodology and first results of the development of high temperature fixed point artifacts of unknown temperature suitable for scale comparison purposes. This study is being undertaken at the Thermal Metrology Division of Inmetro, Brazil, as part of PhD studies. In this initial phase of the study two identical cobalt carbon eutectic cells were constructed and one doped with a known amount of copper. This was an attempt to achieve a controlled change in the transition temperature of the alloy during melting. Copper was chosen due to the relatively simple phase diagram it forms with carbon and cobalt. The cobalt, in powder form, was supplied by Alfa Aesar at 99.998 % purity, and was mixed with carbon powder (1,9 % by weight) of 99.9999 % purity. Complete filling of the crucible took 6 steps and was performed in a vertical furnace with graphite heating elements, in an inert gas atmosphere. The temperature measurements were performed using a KE LP3 radiation thermometer, which was previously evaluated for spectral responsivity, linearity and size-of-source effect (SSE). During these measurements, the thermometer stability was periodically checked using a silver fixed point blackbody maintained in a three zone furnace. The main purpose of the first part of this study is to dope a series of Co-C blackbody with differing amounts of copper, in order to alter their temperatures whilst still retaining good melting plateau performance. The long-term stability of the adjusted transition temperatures will also be investigated. Other dopants will be studied as the research progresses, and thermo chemical modeling will be performed in an attempt to understand the change in temperature with dopant concentration and so help select suitable dopants in the future. The overall objective is to construct comparison artifacts that have good performance, in terms of plateau shape and long-term temperature stability, but with unknown temperatures. These can then be used as comparison artifacts with no participant, except the pilot, knowing the temperature a priori.

36 MATERIALS SCIENCE↗

Towards protein-crystal centering using second-harmonic generation (SHG) microscopy

The potential of second-harmonic generation (SHG) microscopy for automated crystal centering to guide synchrotron X-ray diffraction of protein crystals has been explored. The potential of second-harmonic generation (SHG) microscopy for automated crystal centering to guide synchrotron X-ray diffraction of protein crystals was explored. These studies included (i) comparison of microcrystal positions in cryoloops as determined by SHG imaging and by X-ray diffraction rastering and (ii) X-ray structure determinations of selected proteins to investigate the potential for laser-induced damage from SHG imaging. In studies using β{sub 2} adrenergic receptor membrane-protein crystals prepared in lipidic mesophase, the crystal locations identified by SHG images obtained in transmission mode were found to correlate well with the crystal locations identified by raster scanning using an X-ray minibeam. SHG imaging was found to provide about 2 µm spatial resolution and shorter image-acquisition times. The general insensitivity of SHG images to optical scatter enabled the reliable identification of microcrystals within opaque cryocooled lipidic mesophases that were not identified by conventional bright-field imaging. The potential impact of extended exposure of protein crystals to five times a typical imaging dose from an ultrafast laser source was also assessed. Measurements of myoglobin and thaumatin crystals resulted in no statistically significant differences between structures obtained from diffraction data acquired from exposed and unexposed regions of single crystals. Practical constraints for integrating SHG imaging into an active beamline for routine automated crystal centering are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A parametric study of slow dynamic nonlinear elasticity with comparisons to models

Several phenomenological models that aspire to quantitative description of anomalous nonlinear mesoscopic elasticity are reviewed and compared with laboratory measurements. This class of nonlinearity, best known perhaps for slow dynamics and aging, is seen widely in imperfectly consolidated granular solids but is not well understood. Typical slow dynamic tests show that a modest conditioning oscillatory "pump" strain depresses material stiffness, which then recovers like the logarithm of time after conditioning ceases. Several phenomenological models based on physical arguments have been proposed that predict the material stiffness response to arbitrary pump strain histories during conditioning and recovery. Approximate closed form and numerical solutions to the models are presented that predict the quantitative influence of three key pump parameters: the pump's strain amplitude, the pump's strain rate, and the pump’s duration. Laboratory measurements on Berea sandstone, concrete and a confined single aluminum bead find that slow dynamic responses are linear in pump strain and independent of pump frequency. Measurements also show that, after pump-off, stiffness recovers over times far longer than the pump duration. These observations and others are compared to model predictions. One of the considered models, based on a picture of fast brittle damage and slow healing, successfully matches all these behaviors.

36 MATERIALS SCIENCE↗

The Symmetrical Quasi-Classical Model for Electronically Non-Adiabatic Processes Applied to Energy Transfer Dynamics in Site-Exciton Models of Light-Harvesting Complexes

In a recent series of papers, it has been illustrated that a symmetrical quasi-classical (SQC) windowing model applied to the Meyer–Miller (MM) classical vibronic Hamiltonian provides an excellent description of a variety of electronically non-adiabatic benchmark model systems for which exact quantum results are available for comparison. In this study, the SQC/MM approach is used to treat energy transfer dynamics in site-exciton models of light-harvesting complexes, and in particular, the well-known 7-state Fenna–Mathews–Olson (FMO) complex. Again, numerically “exact” results are available for comparison, here via the hierarchical equation of motion (HEOM) approach of Ishizaki and Fleming, and it is seen that the simple SQC/MM approach provides very reasonable agreement with the previous HEOM results. Finally, it is noted, however, that unlike most (if not all) simple approaches for treating these systems, because the SQC/MM approach presents a fully atomistic simulation based on classical trajectory simulation, it places no restrictions on the characteristics of the thermal baths coupled to each two-level site, e.g., bath spectral densities (SD) of any analytic functional form may be employed as well as discrete SD determined experimentally or from MD simulation (nor is there any restriction that the baths be harmonic), opening up the possibility of simulating more realistic variations on the basic site-exciton framework for describing the non-adiabatic dynamics of photosynthetic pigment complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cloud Phase Simulation at High Latitudes in EAMv2: Evaluation using CALIPSO Observations and Comparison with EAMv1

This study performs a comprehensive evaluation of the simulated cloud phase in the U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SM) atmosphere model version 2 (EAMv2) and version 1 (EAMv1). Enabled by the CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation) simulator, EAMv2 and EAMv1 predicted cloud phase is compared against the GCM-Oriented CALIPSO Cloud Product (CALIPSO-GOCCP) at high latitudes where mixed-phase clouds are prevalent. Our results indicate that the underestimation of cloud ice in simulated high-latitude mixed-phase clouds in EAMv1 has been significantly reduced in EAMv2. The increased ice clouds in the Arctic mainly result from the modification on the WBF (Wegner-Bergeron-Findeisen) process in EAMv2. The impact of the modified WBF process is moderately compensated by the low limit of cloud droplet number concentration (CDNC) in cloud microphysics and the new dCAPE_ULL trigger used in deep convection in EAMv2. Moreover, it is found that the new trigger largely contributes to the better cloud phase simulation over the Norwegian Sea and Barents Sea in the Arctic and the Southern Ocean where large errors are found in EAMv1. However, errors in simulated cloud phase in EAMv1, such as the overestimation of supercooled liquid clouds near the surface in both hemispheres and the underestimation of ice clouds over Antarctica, persist in EAMv2. In conclusion, this study highlights the impact of deep convection parameterizations, which has received little attention, on high-latitude mixed-phase clouds, and the importance of continuous improvement of cloud microphysics in climate models for accurately representing mixed-phase clouds.

54 ENVIRONMENTAL SCIENCES↗

Amorphous to fcc-polycrystal transition in Ge{sub 2}Sb{sub 2}Te{sub 5} thin films studied by electrical measurements: Data analysis and comparison with direct microscopy observations

We experimentally investigate the isothermal amorphous-to-fcc polycrystalline phase transition process in amorphous Ge{sub 2}Sb{sub 2}Te{sub 5} thin films prepared by sputtering. The amorphous layers were either as deposited or formed by Ar{sup +} ion implantation after crystallization at 300 deg. C. The kinetics of the amorphous-to-polycrystal transition are analyzed through electrical measurements, in which the Johnson-Mehl-Avrami-Kolmogorov theory is employed. The procedure to extract the kinetics of the phase transition from conductivity versus time data is carefully discussed and compared to data of cross-sectional transmission electron microscopy images versus anneal time. By following this proposed procedure, the nucleation and growth parameters, and the activation energies have been determined. Results indicate that the process of isothermal crystallization in Ge{sub 2}Sb{sub 2}Te{sub 5} takes place in two stages, in which the Avrami exponent changes in the range from 3 to 1. These results are understood in terms of modifications in the kinetics of the phase transition.

36 MATERIALS SCIENCE↗

Comparison of Martian meteorites with earth composition: Study of effective atomic numbers in the energy range 1 keV-100 GeV

Effective atomic (Z{sub eff}) and electron numbers (N{sub eff}) for 24 Martian meteorites have been determined in the energy range from 1 keV to 100 GeV and also for sixteen significant energies of commonly used radioactive sources. The values of Z{sub eff} and N{sub eff} for all sample were obtained from the DirectZeff program. The obtained results for Martian meteorites have been compared with the results for Earth composition and similarities or differences also evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rock Valley Direct Earthquake-Explosion Comparison Experiment (RV-DC): Initial Feasibility Study

The RV-­DC is designed to be the capstone of the ongoing Source Physics Experiments. This report describes the motivation behind the RV-­DC and the tremendous potential scientific payoff for both nuclear explosion monitoring and earthquake source physics expected from the RV-­DC experiment. The report describes the issues, work to date and plans for FY13 in the areas of defining the shot location, depth and size, as well as addressing potential concerns about induced seismicity. We believe the RV-­DC is feasible. There do not appear to be any significant technical or scientific issues that would prevent the RV-DC from being carried out in the approximately FY14‐16 timeframe. This timeframe allows sufficient time for work to continue in FY13 to better define the experimental plan. It is our recommendation, based on the work to date and the potential payoff of the RV-­DC experiment, that the currently defined work for FY13 to better define the experimental plan, proceed.

58 GEOSCIENCES↗

Energy Cost Savings of Systems-Based Building Retrofits: A Study of Three Integrated Lighting Systems in Comparison with Component Based Retrofits

Most building retrofit projects are still component-based in that they typically address only one piece or type of equipment at a time. Systems-based retrofits that seek to address multiple components in an integrated manner have the potential to provide significantly greater energy savings. Lawrence Berkeley National Laboratory (LBNL) partnered with several utilities to develop and evaluate three different integrated retrofit packages involving lighting systems: automated shading with daylight dimming controls, workstation-specific lighting with daylight controls, and task/ambient lighting with plug load occupancy controls. Specifically, our analysis sought to quantify the marginal benefits of these systems (energy savings as well as lighting performance and visual comfort) relative to component based approaches. The analysis was based on a combination of measured performance data from LBNL’s FLEXLAB® test facility and energy simulations. All three systems were compared to a simple fluorescent-to-LED retrofit, which represents the component-based approach. While the simple LED upgrade provides significant lighting energy savings of 63%, the systems yielded energy savings of 81-93%, which equates to additional savings of 49-82% over the simple LED upgrade. All systems tested provided satisfactory visual comfort as well, indicating good potential for market acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗