Search NASA⌕ Search

SEARCH · Search NASA

Results for “Delayed Gamma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Semi-automated lab-on-a-chip for dispensing GA-68 radiotracers

We solved a technical problem that is hindering American progress in molecular medicine, and restricting US citizens from receiving optimal diagnostic care. Specifically, the project deals with a mother/daughter generator of positron-emitting radiotracers (Ge-68/Ga-68). These generator systems are approved in Europe but cannot be used in the USA, because of safety issues related to possible breakthrough of long-lived Ge-68 (mother) atoms. Europeans have demonstrated abilities of Ga-68-labeled radiotracers to image cancer foci with high sensitivity and specificity, and to use such methods to effectively plan therapy.The USA Food and Drug Administration (FDA) and Nuclear Regulatory Commission (NRC) have taken the position that every patient administration of Ga-68 should be preceded by an assay demonstrated that Ge-68 breakthrough is within acceptable limits. Breakthrough of parent elements is a sensitive subject at the FDA, as evidenced by the recent recall of Rb-82 generators due to inadvertent administrations of Sr-82. Commercially, there is no acceptable rapid method for assaying breakthrough of Ge-68 prior to each human administration. The gamma emissions of daughter Ga-68 have higher energies than the parent Ge-68, so that the shielding assays typically employed for Mo-99/Tc-99m generators cannot be applied to Ga-68 generators. The half-life of Ga-68 is 68 minutes, so that the standard 10-half-life delay (used to assess breakthrough in Sr-82/Rb-82 generators) cannot be applied to Ga-68 generators. As a result of the aforementioned regulatory requirements, Ga-68 generators are sold in the USA for animal use only.The American clinical community’s inability to utilize Ga-68 generators impairs abilities to treat patients domestically, and puts the USA at a disadvantage in developing exportable products. The proposed DOE project aimed to take advantage of recent technological advances developed for lab-on-a-chip (LOC) applications. Based on our experiences constructing such devices, the proposed microfluidics-based approach could provide cost-effective validation of breakthrough compliance in minutes.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of impulsive phase phenomena

A brief review is given of impulsive phase phenomena in support of the models used to compute the energies of the different components of the flares under study. The observational characteristics of the impulsive phase are discussed as well as the evidence for multi-thermal or non-thermal phenomena. The significance of time delays between hard X-rays and microwaves is discussed in terms of electron beams and Alfven waves, two-step acceleration, and secondary bursts at large distances from the primary source. Observations indicating the occurrence of chromospheric evaporation, coronal explosions, and thermal conduction fronts are reviewed briefly, followed by the gamma ray and neutron results. Finally, a preferred flare scenario and energy source are presented involving the interactions in a complex of magnetic loops with the consequent reconnection and electron acceleration.

Dejager, C.↗

NASA Tech Briefs, October 2009

Topics covered include: Light-Driven Polymeric Bimorph Actuators; Guaranteeing Failsafe Operation of Extended-Scene Shack-Hartmann Wavefront Sensor Algorithm; Cloud Water Content Sensor for Sounding Balloons and Small UAVs; Pixelized Device Control Actuators for Large Adaptive Optics; T-Slide Linear Actuators; G4FET Implementations of Some Logic Circuits; Electrically Variable or Programmable Nonvolatile Capacitors; System for Automated Calibration of Vector Modulators; Complementary Paired G4FETs as Voltage-Controlled NDR Device; Three MMIC Amplifiers for the 120-to-200 GHz Frequency Band; Low-Noise MMIC Amplifiers for 120 to 180 GHz; Using Ozone To Clean and Passivate Oxygen-Handling Hardware; Metal Standards for Waveguide Characterization of Materials; Two-Piece Screens for Decontaminating Granular Material; Mercuric Iodide Anticoincidence Shield for Gamma-Ray Spectrometer; Improved Method of Design for Folding Inflatable Shells; Ultra-Large Solar Sail; Cooperative Three-Robot System for Traversing Steep Slopes; Assemblies of Conformal Tanks; Microfluidic Pumps Containing Teflon[Trademark] AF Diaphragms; Transparent Conveyor of Dielectric Liquids or Particles; Multi-Cone Model for Estimating GPS Ionospheric Delays; High-Sensitivity GaN Microchemical Sensors; On the Divergence of the Velocity Vector in Real-Gas Flow; Progress Toward a Compact, Highly Stable Ion Clock; Instruments for Imaging from Far to Near; Reflectors Made from Membranes Stretched Between Beams; Integrated Risk and Knowledge Management Program -- IRKM-P; LDPC Codes with Minimum Distance Proportional to Block Size; Constructing LDPC Codes from Loop-Free Encoding Modules; MMICs with Radial Probe Transitions to Waveguides; Tests of Low-Noise MMIC Amplifier Module at 290 to 340 GHz; and Extending Newtonian Dynamics to Include Stochastic Processes.

Source record↗

BINARY NEUTRON STAR MERGERS: A JET ENGINE FOR SHORT GAMMA-RAY BURSTS

We perform magnetohydrodynamic simulations in full general relativity (GRMHD) of quasi-circular, equal-mass, binary neutron stars that undergo merger. The initial stars are irrotational, n = 1 polytropes and are magnetized. We explore two types of magnetic-field geometries: one where each star is endowed with a dipole magnetic field extending from the interior into the exterior, as in a pulsar, and the other where the dipole field is initially confined to the interior. In both cases the adopted magnetic fields are initially dynamically unimportant. The merger outcome is a hypermassive neutron star that undergoes delayed collapse to a black hole (spin parameter a / M {sub BH} ∼ 0.74) immersed in a magnetized accretion disk. About 4000 M ∼ 60( M {sub NS}/1.625 M {sub ⊙}) ms following merger, the region above the black hole poles becomes strongly magnetized, and a collimated, mildly relativistic outflow—an incipient jet—is launched. The lifetime of the accretion disk, which likely equals the lifetime of the jet, is Δ t ∼ 0.1 ( M {sub NS}/1.625 M {sub ⊙}) s. In contrast to black hole–neutron star mergers, we find that incipient jets are launched even when the initial magnetic field is confined to the interior of the stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of SNAC2 area dosimeters placed in different configurations around the PROSPERO reactor and comparison with TRIPOLI-4 calculations

In the context of criticality accident alarm system tests, several experiments were carried out in 2013 on the PROSPERO reactor to study the response to neutron and gamma of different devices and dosimeters, particularly on the SNAC2 dosimeter. This article presents the results of this criticality dosimeter in different configurations, and compares the experimental measurements with the results of calculation performed with the TRIPOLI-4 Monte-Carlo Neutral Particles transport code. PROSPERO is a metallic critical assembly managed by the Criticality, Neutron Science and Measurement Department located at the French CEA Research Center of Valduc. The core, surrounded by a reflector of depleted uranium, is composed of 2 horizontal cylindrical blocks made of a highly enriched uranium alloy which can be placed in contact, and of 4 depleted uranium control rods which allow the reactor to be driven. This reactor, placed in a cell 10 m x 8 m x 6 m high, with 1.4-meter-thick concrete walls, is used as a fast neutron spectrum source and is operated at stable power level in delayed critical state, which can vary from 3 mW to 3 kW. PROSPERO is extensively used for electronic hardening or to study the effect of the neutrons on various materials. The SNAC2 criticality dosimeter is a zone dosimeter allowing the off line measurement of criticality accident neutron doses. This dosimeter consists of the pile up of seven activation foils embedded into a 23 mm diameter x 21 mm height cadmium container. The activation measurement of each foil, using a gamma spectroscopy technique, gives information about the neutron reaction rates. The SNAC2 software allows the spectrum unfolding from these values, taking into account the hypothesis of a particular spectrum shape, in three components: a Maxwell spectrum component for the thermal range, a 1/E component for the epithermal range, and a Watt spectrum component for the high energy range. Moreover, from the neutron spectrum, the SNAC software can calculate the neutron fluence integrated by the dosimeter and the neutron dose. During the 3 weeks measurement campaign many radioprotection devices were used. To modify the spectrum seen by these devices, several shields of various thicknesses made of concrete or polyethylene, with or without cadmium covers, were placed in the PROSPERO cell. These devices allow the study of criticality accident spectra in several environments: from metal to pseudo liquid. The fluxes measured by the SNAC2 devices were compared with TRIPOLI-4 calculations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-QI-13: Predictable Models for Radio-Sensitizing Agent Kinetics: Application to Stereotactic Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The radiation dose enhancement depends on the time course of iodine in the tumors. A prolonged CT scanning (∼30 min) is required to follow-up iodine kinetics for recruited patients. This protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce the acquisition time. Methods: 12 patients received an intravenous bolus of iodinated contrast agent, followed by a steady-state infusion to ensure stable intra-tumoral amounts of iodine during the treatment. Absolute iodine concentrations (IC) were derived from 40 multi-slice dynamic conventional CT images of the brain. The impulse response function (IRF) to the bolus was estimated using the adiabatic approximation of the Johnson and Wilson's model. The arterial input function (AIF) of the steady-state infusion was fitted with several models: Gamma, Gamma with recirculation and hybrid. Estimated IC were calculated by convolving the IRF with the modeled AIF and were compared to the measured data. Results: The gamma variate function was not relevant to model the AIF due to high differences with the measured AIF. The hybrid and the gamma with recirculation models provided differences below 8% during the whole acquisition time. The absolute difference between the measured and the estimated IC was lower than 0.5 mg/ml, which corresponds to 5% of dose enhancement error. Conclusion: The proposed method allows a good estimation of the iodine time course with reduced scanning delays (3 instead of 30 min) and dose to the patient. The results suggest that the dose errors may stay within the radiotherapy standards.

60 APPLIED LIFE SCIENCES↗

The Measurement of Radiation Exposure of Astronauts by Radiochemical Techniques

The principal gamma-ray-omitting radioisotopes produced in the body of astronauts by cosmic-ray bombardment which have half-lives long enough to be useful for radiation dose evaluation are Be-7, Na-22, and Na-24. The sodium isotopes were measured in the preflight and postflight urine and feces, and those feces specimens collected during the manned Apollo missions, by analysis of the urine salts and the raw feces in large crystal multidimensional gamma-ray spectrometers. The Be-7 was chemically separated, and its concentration measured in an all Na(T1), anticoincidence shielded, scintillation well crystal. The overall sensitivity of the experiment was reduced by almost all variables such as low concentrations of excreted cosmogenic radionuclides, high concentrations of injected radionuclides, low sample sizes, long delay periods before analysis, and uncertain excretion rates. The astronaut radiation dose in millirads, as determined by this technique, for the Apollo 7, 8, 9, 10, 11, 12, and 13 missions was 330, 160, 315, 870 ? 550, 31, 110, and 250 respectively. In view of these limitations this technique would be best applied to cases of unusually high exposures, such as that encountered from solar flares.

R L Brodzinski↗

Detection of significant cm to sub-mm band radio and γ-ray correlated variability in Fermi bright blazars

The exact location of the γ-ray emitting region in blazars is still controversial. In order to attack this problem we present first results of a cross-correlation analysis between radio (11 cm to 0.8 mm wavelength, F-GAMMA programme) and γ-ray (0.1–300 GeV) ~3.5 yr light curves of 54 Fermi-bright blazars. We perform a source stacking analysis and estimate significances and chance correlations using mixed source correlations. These results reveal: (i) the first highly significant multiband radio and γ-ray correlations (radio lagging γ rays) when averaging over the whole sample, (ii) average time delays (source frame: 76 ± 23 to 7 ± 9 d), systematically decreasing from cm to mm/sub-mm bands with a frequency dependence τr, γ(ν) ∝ ν -1 , in good agreement with jet opacity dominated by synchrotron self-absorption, (iii) a bulk γ-ray production region typically located within/upstream of the 3 mm core region (τ3mm, γ = 12 ± 8 d), (iv) mean distances between the region of γ-ray peak emission and the radio ‘τ = 1 photosphere’ decreasing from 9.8 ± 3.0 pc (11 cm) to 0.9 ± 1.1 pc (2 mm) and 1.4 ± 0.8 pc (0.8 mm), (v) 3 mm/γ-ray correlations in nine individual sources at a significance level where one is expected by chance (probability: 4 × 10 -6 ), (vi) opacity and ‘time lag core shift’ estimates for quasar 3C 454.3 providing a lower limit for the distance of the bulk γ-ray production region from the supermassive black hole (SMBH) of ~0.8–1.6 pc, i.e. at the outer edge of the broad-line region (BLR) or beyond. A 3 mm τ = 1 surface at ~2–3 pc from the jet base (i.e. well outside the ‘canonical BLR’) finally suggests that BLR material extends to several parsec distances from the SMBH.

79 ASTRONOMY AND ASTROPHYSICS↗

H-alpha manifestation of an energetic limb flare, June 21, 1980

H-alpha observations of a limb flare, which were associated with exceptional gamma-ray and hard X-ray emission, are presented and discussed. The good spatial and temporal resolution of the H-alpha data allow investigation of the detailed structure of the elevated flare loops and the intensity variations of the loops, footpoints and surrounding chromosphere during each phase of the flare event. A delay time of about 12 s was found between at least one of the hard X-ray (28-485 keV) peaks and corresponding H-alpha intensity maximum at a loop footpoint. A comparison is made between this event and another well-observed limb flare with many similar characteristics, to seek evidence for the large difference in their levels of energy release.

Mccabe, M. K.↗

DIVERSITY OF SHORT GAMMA-RAY BURST AFTERGLOWS FROM COMPACT BINARY MERGERS HOSTING PULSARS

Short-duration gamma-ray bursts (sGRBs) are widely believed to result from the mergers of compact binaries. This model predicts an afterglow that bears the characteristic signatures of a constant, low-density medium, including a smooth prompt-afterglow transition, and a simple temporal evolution. However, these expectations are in conflict with observations for a non-negligible fraction of sGRB afterglows. In particular, the onset of the afterglow phase for some of these events appears to be delayed and, in addition, a few of them exhibit late-time rapid fading in their light curves. We show that these peculiar observations can be explained independently of ongoing central engine activity if some sGRB progenitors are compact binaries hosting at least one pulsar. The Poynting flux emanating from the pulsar companion can excavate a bow-shock cavity surrounding the binary. If this cavity is larger than the shock deceleration length scale in the undisturbed interstellar medium, then the onset of the afterglow will be delayed. Should the deceleration occur entirely within the swept-up thin shell, a rapid fade in the light curve will ensue. We identify two types of pulsar that can achieve the conditions necessary for altering the afterglow: low-field, long-lived pulsars, and high-field pulsars. We find that a sizable fraction (≈20%-50%) of low-field pulsars are likely to reside in neutron star binaries based on observations, while their high-field counterparts are not. Hydrodynamical calculations motivated by this model are shown to be in good agreement with observations of sGRB afterglow light curves.

79 ASTRONOMY AND ASTROPHYSICS↗

Neutrino oscillations in magnetically driven supernova explosions

We investigate neutrino oscillations from core-collapse supernovae that produce magnetohydrodynamic (MHD) explosions. By calculating numerically the flavor conversion of neutrinos in the highly non-spherical envelope, we study how the explosion anisotropy has impacts on the emergent neutrino spectra through the Mikheyev-Smirnov-Wolfenstein effect. In the case of the inverted mass hierarchy with a relatively large θ{sub 13} (sin{sup 2} 2θ{sub 13} ∼> 10{sup −3}), we show that survival probabilities of ν-bar {sub e} and ν{sub e} seen from the rotational axis of the MHD supernovae (i.e., polar direction), can be significantly different from those along the equatorial direction. The event numbers of ν-bar {sub e} observed from the polar direction are predicted to show steepest decrease, reflecting the passage of the magneto-driven shock to the so-called high-resonance regions. Furthermore we point out that such a shock effect, depending on the original neutrino spectra, appears also for the low-resonance regions, which could lead to a noticeable decrease in the ν{sub e} signals. This reflects a unique nature of the magnetic explosion featuring a very early shock-arrival to the resonance regions, which is in sharp contrast to the neutrino-driven delayed supernova models. Our results suggest that the two features in the ν-bar {sub e} and ν{sub e} signals, if visible to the Super-Kamiokande for a Galactic supernova, could mark an observational signature of the magnetically driven explosions, presumably linked to the formation of magnetars and/or long-duration gamma-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects; from coding an Arduino to building PVC piping to 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into/out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects such as coding an Arduino, building PVC piping, and 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into and out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled or pushed through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point. These times, as well as the temperatures, are the data necessary for the project and must be extremely accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

INTEGRAL Observations of the Be/X-ray binary EX0 2030+375 During Outburst

We present a type-I outburst of the high-mass X-ray binary EX0 2030+375, detected during INTEGRAL'S Performance and Verification phase in December 2002 (on-source time about 10(exp 6) seconds). In addition, six more outbursts have been observed during INTEGRAL'S Galactic Plane Scans. X-ray pulsations have been detected with a pulse period of 41.691798 plus or minus 0.000016 s. The X-ray luminosity in the 5-300 keV energy range was 9.7 x 10 (exp 36) erg per second, for a distance of 7.1 kpc. Two unusual features were found in the light curve, with an initial peak before the main outburst and another possible spike after the maximum. RXTE observations confirm only the existence of the initial spike. Although the initial peak appears to be a recurrent feature, the physical mechanisms producing it and the possible second spike are unknown. Moreover, a four-day delay between periastron passage and the peak of the outburst is observed. We present for the first time a 5-300 keV broad-band spectrum of this source. It can be modelled by the sum of a disk black body (kT(sub BB) approximately 8 keV) and either with a power law model with Gamma=2.04 plus or minus 0.11 keV or a Comptonized component (spherical geometry, kT(sub e).=30 keV, tau = 2.64, kT(sub w)=1.5 keV).

Arranz, A. Camero↗

Active Neutron Interrogation as a Method for Verification of the Absence of Special Nuclear Material in Arms Control Dismantlement

The next step in arms control reductions will deal with both strategic and non-strategic weapons, presenting new and hard challenges for verification. One verification approach that might be used in support of these reductions is the concept of deferred verification, which forgoes inspections at sensitive nuclear sites and relies on an inspection regime having access to the open segment of a State's nuclear sector, in "monitored transfer zones." A component of this approach is the anticipated need for an instrument suite capable of detecting well-shielded highly-enriched uranium or plutonium where it isn't supposed to be. This specific need was recently identified by the United Nations Institute for Disarmament Research in an enabling operating concept they call "contain and dispose." At the foundation of this approach is the idea that items declared as "not nuclear" are, by definition, not treaty limited and are thus "fair-game" for inspection and questioning. Active Neutron Interrogation (ANI), using beta-delayed neutron emissions as the signature for special nuclear material (SNM) detection, is a promising method to address this challenge. The method is quick, has high sensitivity and high specificity for detecting shielded SNM, is robust against changing background radiation environments, is robust against the presence of unknown shielding, and avoids the use of gamma-ray spectrometry which may introduce complications due to the potential release of sensitive information. This paper will present recent research activities exploring technical aspects of using ANI as a FAIRGAME verification method and discuss future prospects and research needs

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Jet outflow and gamma-ray emission correlations in S5 0716+714

Here, using millimeter very long baseline interferometry (VLBI) observations of the BL Lac object S5 0716+714 from August 2008 to September 2013, we investigate variations in the core flux density and orientation of the sub-parsec scale jet, i.e. position angle. The γ-ray data obtained by the Fermi Large Area Telescope are used to investigate the high-energy flux variations over the same time period. For the first time in any blazar, we report a significant correlation between the γ-ray flux variations and the position angle variations in the VLBI jet. The cross-correlation analysis also indicates a positive correlation such that the mm-VLBI core flux density variations are delayed with respect to the γ-ray flux by 82±32 days. This suggests that the high-energy emission is coming from a region located ≥(3.8±1.9) parsecs upstream of the mm-VLBI core (closer to the central black hole). Lastly, these results imply that the observed inner jet morphology has a strong connection with the observed γ-ray flares.

79 ASTRONOMY AND ASTROPHYSICS↗

CMB data constraint on self-annihilation of dark matter particles

Recently, self-annihilation of dark matter particles is proposed to explain the ''WMAP Haze'' and excess of energetic positrons and electrons in ATIC and PAMELA results. If self-annihilation of dark matter occurs around the recombination of cosmic plasma, energy release from self-annihilation of dark matter delays the recombination, and hence affects CMB anisotropy. By using the recent CMB data, we have investigated the self-annihilation of dark matter particles. In this investigation, we do not find statistically significant evidence, and impose an upper bound on <{sigma}{nu}>/m{sub {kappa}.}The upcoming data from Planck surveyor and the Fermi Gamma-ray telescope will allow us to break some of parameter degeneracy and improve constraints on self-annihilation of dark matter particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions

Purpose: As traditional film is phased out in most radiotherapy centers, computed radiography (CR) systems are increasingly being purchased as a replacement. CR plates can be used for patient imaging, but may also be used for a variety of quality assurance (QA) purposes and can be calibrated in terms of dose. This study looks at their suitability for verification of intensity modulated radiation therapy (IMRT) dose distributions. Methods: A CR plate was calibrated in terms of the relative dose and the stability of response over 1 year was studied. The effect of exposing the CR plate to ambient light and of using different time delays before scanning was quantified. The CR plate was used to verify the relative dose distributions for ten IMRT patients and the results were compared to those obtained using a two dimensional (2D) diode array. Results: Exposing the CR plate to 10 s of ambient light between irradiation (174 cGy) and scanning erased approximately 80% of the signal. Changes in delay time between irradiation and scanning also affected the measurement results. The signal on the plate was found to decay at a rate of approximately 3.6 cGy/min in the first 10 min after irradiation. The use of a CR plate for IMRT patient-specific QA resulted in a significantly lower distance to agreement (DTA) and gamma pass rate than when using a 2D diode array for the measurement. This was primarily due to the over-response of the CR phosphor to low energy scattered radiation. For the IMRT QA using the CR plate, the average gamma pass rate was 97.3%. For the same IMRT QA using a diode array, the average gamma pass rate was 99.7%. The gamma criteria used were 4% dose difference and 4 mm DTA for head and neck treatments and 3% dose difference and 3 mm DTA for prostate treatments. The gamma index tolerance was 1. The lowest 10% of the dose distribution was excluded from all gamma and DTA analyses. Conclusions: Although the authors showed that CR plates can be used for patient specific IMRT QA, the practical problems such as the over-response to low energy scatter and signal fading with light exposure and time mean that alternative detectors such as radiochromic film or diode arrays will be a more sensible choice for most radiotherapy departments.

60 APPLIED LIFE SCIENCES↗