Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection approach”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Solution‐Processed CsPbBr 3 Quantum Dots/Organic Semiconductor Planar Heterojunctions for High‐Performance Photodetectors

Abstract Planar heterojunctions (PHJs) are fundamental building blocks for construction of semiconductor devices. However, fabricating PHJs with solution‐processable semiconductors such as organic semiconductors (OSCs) is a challenge. Herein, utilizing the orthogonal solubility and good wettability between CsPbBr 3 perovskite quantum dots (PQDs) and OSCs, fabrication of solution‐processed PQD/OSC PHJs are reported. The phototransistors based on bilayer PQD/PDVT‐10 PHJs show responsivity up to 1.64 × 10 4 A W −1 , specific detectivity of 3.17 × 10 12 Jones, and photosensitivity of 5.33 × 10 6 when illuminated by 450 nm light. Such high photodetection performance is attributed to efficient charge dissociation and transport, as well as the photogating effect in the PHJs. Furthermore, the tri‐layer PDVT‐10/PQD/Y6 PHJs are used to construct photodiodes working in self‐powered mode, which exhibit broad range photoresponse from ultraviolet to near‐infrared, with responsivity approaching 10 −1 A W −1 and detectivity over 10 6 Jones. These results present a convenient and scalable production processes for solution‐processed PHJs and show their great potential for optoelectronic applications.

36 MATERIALS SCIENCE↗

GenAI-Based Digital Twins Aided Data Augmentation Increases Accuracy in Real-Time Cokurtosis-Based Anomaly Detection of Wearable Data

Early detection of potential infectious disease outbreaks is crucial for developing effective interventions. In this study, we introduce advanced anomaly detection methods tailored for health datasets collected from wearables, offering insights at both individual and population levels. Leveraging real-world physiological data from wearables, including heart rate and activity, we developed a framework for the early detection of infection in individuals. Despite the availability of data from recent pandemics, substantial gaps remain in data collection, hindering method development. To bridge this gap, we utilized Wasserstein Generative Adversarial Networks (WGANs) to generate realistic synthetic wearable data, augmenting our dataset for training. Subsequently, we use these augmented datasets to implement a cokurtosis-based technique for anomaly detection in multivariate time-series data. Our approach includes a comprehensive assessment of uncertainties in synthetic data compared to the actual data upon which it was modeled, as well as the uncertainty associated with fine-tuning anomaly detection thresholds in physiological measurements. Through our work, we present an enhanced method for early anomaly detection in multivariate datasets, with promising applications in healthcare and beyond. This framework could revolutionize early detection strategies and significantly impact public health response efforts in future pandemics.

Data-Driven Digital Twins↗

Predicting critical heat flux using localized sensing at invisible vapor-liquid interfaces

Predicting critical heat flux (CHF) in two-phase electronics cooling systems remains a significant challenge due to the sudden onset of boiling crisis and the difficulty in directly visualizing vapor-liquid interfaces. Existing sensing methods rely on lagging temperature measurements, optically accessible systems, or spatially averaged signals that cannot pinpoint CHF initiation at localized high-heat-flux regions. Here, we report a planar capacitive sensing approach that enables real-time, localized detection of vapor-liquid interface dynamics for CHF prediction in boiling heat transfer. The capacitive sensor exploits the dielectric constant difference between liquid and vapor phases to capture bubble nucleation, growth, and departure dynamics with a temporal resolution down to 2 ms. The capacitive sensing reveals distinct signals across boiling regimes: from high-frequency fluctuations during strong nucleate boiling to low-frequency fluctuations with increased amplitudes when approaching CHF. The multi-sensor array experiments demonstrate real-time localized sensing, where each sensor responds exclusively to boiling in its immediate vicinity without crosstalk from neighboring regions. This non-intrusive sensing approach provides predictive rather than lagging sensing signals of CHF occurrence, offering predictive diagnosis of two-phase liquid cooling for the thermal management of high-power-density electronics.

CHF↗

A Systematic Search for MeV–GeV Pulsar Wind Nebulae without Gamma-Ray Detected Pulsars

An increasing number of pulsar wind nebulae (PWNe) are being identified in the TeV band by ground-based Imaging Air Cherenkov Telescopes such that they constitute the dominant source class of Galactic TeV emitters. However, MeV–GeV PWN counterparts are still largely lacking. To date, only a dozen PWNe are identified by the Fermi–Large Area Telescope (LAT) in the MeV–GeV band. Most PWNe are located along the Galactic plane embedded within the prominent, diffuse Galactic γ-ray emission, which makes these sources difficult to disentangle from the bright diffuse background. We present a systematic search for γ-ray counterparts to known PWNe in the 300 MeV–2 TeV energy band using the Fermi–LAT. We target the locations of previously identified PWNe that lack detected Fermi–LAT pulsars to minimize associated pulsar contamination. The sample includes six previously identified Fermi PWNe and eight Fermi–LAT sources associated with PWNe. We report the analysis of 58 regions of interest and classify Fermi–LAT detected sources as either a likely PWN or a candidate PWN counterpart based on their morphological and spectral characteristics across the broadband spectrum. There are nine unidentified Fermi–LAT sources that we consider as likely PWN counterparts, which, if confirmed to be PWNe, would greatly increase the PWN population detected by the Fermi–LAT from 12 to 21. The remaining Fermi–LAT detected sources are considered weaker PWN candidates. A second approach in the systematic search for γ-ray emitting PWNe will involve studying the off-pulse phases of Fermi–LAT detected pulsars for the presence of an obscured PWN and will be reported in a subsequent paper.

Acharyya, A. [Univ. of Southern Denmark, Odense (D↗

Statistical Performance of Forced Oscillation Detectors in the Presence of Missing Measurements

In bulk power systems, measurement-based monitoring for large oscillations can help maintain system reliability. One of the challenges encountered in a recent field demonstration was the unavailability of measurements due to underlying measurement quality or communication problems. During the demonstration, the oscillation detector ignored a measurement location if even 10 seconds of data was missing. To extend the detector's ability to operate in these conditions, this paper evaluates the impact of three methods for addressing missing data. The strengths and weaknesses of each approach are evaluated using theoretical expressions for the probability of detection along with results from simulated data and publicly available field measurements. Based on these results, a suitable approach is identified that can extend the oscillation detector's performance when large segments of data are missing.

Follum, James D.↗

X-ray chemical imaging for assessing redox microsites within soils and sediments

Redox reactions underlie several biogeochemical processes and are typically spatiotemporally heterogeneous in soils and sediments. However, redox heterogeneity has yet to be incorporated into mainstream conceptualizations and modeling of soil biogeochemistry. Anoxic microsites, a defining feature of soil redox heterogeneity, are non-majority oxygen depleted zones in otherwise oxic environments. Neglecting to account for anoxic microsites can generate major uncertainties in quantitative assessments of greenhouse gas emissions, C sequestration, as well as nutrient and contaminant cycling at the ecosystem to global scales. However, only a few studies have observed/characterized anoxic microsites in undisturbed soils, primarily, because soil is opaque and microsites require µm-cm scale resolution over cm-m scales. Consequently, our current understanding of microsite characteristics does not support model parameterization. To resolve this knowledge gap, we demonstrate through this proof-of-concept study that X-ray fluorescence (XRF) 2D mapping can reliably detect, quantify, and provide basic redox characterization of anoxic microsites using solid phase “forensic” evidence. First, we tested and developed a systematic data processing approach to eliminate false positive redox microsites, i.e., artefacts, detected from synchrotron-based multiple-energy XRF 2D mapping of Fe (as a proxy of redox-sensitive elements) in Fe-“rich” sediment cores with artificially injected microsites. Then, spatial distribution of Fe II and Fe III species from full, natural soil core slices (over cm-m lengths/widths) were mapped at 1–100 µm resolution. These investigations revealed direct evidence of anoxic microsites in predominantly oxic soils such as from an oak savanna and toeslope soil of a mountainous watershed, where anaerobicity would typically not be expected. We also revealed preferential spatial distribution of redox microsites inside aggregates from oak savanna soils. We anticipate that this approach will advance our understanding of soil biogeochemistry and help resolve “anomalous” occurrences of reduced products in nominally oxic soils.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Longitudinal Serum Analysis and Machine Learning to Develop a Classifier for Cancer Early Detection

Early detection of solid tumors through a simple screening process, such as the proteomic analysis of biofluids, has the potential to significantly alter the management and outcomes of cancers. The application of advanced targeted proteomics measurements and data analysis strategies to uniformly collected serum or plasma samples would enable longitudinal studies of cancer risk, progression, and response to therapy that have the potential to significantly reduce cancer burden in general. In this article, we describe a generalizable workflow combining robust, multiplexed targeted proteomics measurements applied to longitudinal samples from the Department of Defense Serum Repository with a Random Forest machine learning method for developing and initially evaluating the performance of candidate biomarker panels for early detection of cancers. The effectiveness of this approach was demonstrated in a cohort of 175 head and neck squamous cell carcinoma patients. The outlined protocols include methods for sample preparation, instrument analysis, and data analysis and interpretation using this workflow.

Longitudinal analysis, machine learning, cancer, e↗

Implementation of Stochastic Gradient Descent in an Automated Glow Peak Identification Software for Multiple Thermoluminescent Dosimeter Types

A glow-curve analysis code was previously developed in C++ to analyze thermoluminescent dosimeter glow curves using automated peak detection while applying a first-order kinetics model. A newer version of this code was implemented to improve the automated peak detection and curve fitting models. The Stochastic Gradient Descent Algorithm was introduced to replace the prior approach of taking first and second-order derivatives for peak detection. Additionally, early stopping mechanisms were invoked to improve the previously used Levenberg-Marquardt Algorithm employed for curve fitting. The two software versions were compared through glow curve analysis of different thermoluminescent dosimeter materials and calculation of the corresponding figures of merit. Altogether improvements were shown, namely an increase in the number of peaks detected and a reduction of the mean figure of merit by approximately 46%.

137Cs↗

A Search for IceCube Events in the Direction of ANITA Neutrino Candidates

During the first three flights of the Antarctic Impulsive Transient Antenna (ANITA) experiment, the collaboration detected several neutrino candidates. Two of these candidate events were consistent with an ultra-high-energy upgoing air shower and compatible with a tau neutrino interpretation. A third neutrino candidate event was detected in a search for Askaryan radiation in the Antarctic ice, although it is also consistent with the background expectation. The inferred emergence angle of the first two events is in tension with IceCube and ANITA limits on isotropic cosmogenic neutrino fluxes. Here we test the hypothesis that these events are astrophysical in origin, possibly caused by a point source in the reconstructed direction. Given that any ultra-high-energy tau neutrino flux traversing the Earth should be accompanied by a secondary flux in the TeV-PeV range, we search for these secondary counterparts in 7 yr of IceCube data using three complementary approaches. In the absence of any significant detection, we set upper limits on the neutrino flux from potential point sources. Finally, we compare these limits to ANITA's sensitivity in the same direction and show that an astrophysical explanation of these anomalous events under standard model assumptions is severely constrained regardless of source spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

BRAVE_EBC-TMT.1.0

Exhaled breath condensate (EBC) represents a low-cost and non-invasive means of examining respiratory health. EBC has been used to discover and validate exhaled volatile and non-volatile biomarkers of disease related to the respiratory system distress such as asthma, COPD, lung cancer, and secondary infections. One newly emerging utilization of EBC, is proteomics analysis, which can provide an unbiased snapshot into ongoing biological processes in the airway. Fully characterizing the biological landscape of EBC collections is challenging though, due to sample variability, and low detection sensitivity. EBC is primarily composed of condensed water, causing technical challenges with detecting key macromolecules from the dilute sample matrix; therefore, high sensitivity techniques are required to unlock the full capability of EBC as a method for non-invasive biomarker detection. To overcome some of these technical challenges for proteomic analyses, we applied our recently developed microscale proteomic techniques and developed a novel TMT based approach which enabled reliable, relative quantification with significantly improved detection of low abundance peptides/proteins across multiple healthy volunteer EBC samples. Our EBC collection design includes longitudinal EBC collections from five individual healthy volunteers on three separate days of the week with triplicate, back-to-back donations each day. Here, we report a total of 235 quantifiable proteins corresponding to 1,877 non-redundant peptides for evaluating sample collection reproducibility and establishing a healthy (human host) baseline EBC biomarker proteome studies. This work will pave the way for further investigations of EBC protein expression profiles and showcase the value of using non-invasive collection method techniques for clinically relevant biomarker discovery. This research was supported by the LDRD Biomedical Resilience And Readiness in AdVerse Operating Environments (BRAVE) Project (73748), and was conducted at Pacific Northwest National Laboratory (PNNL) in Richland, WA. PNNL is a multiprogram national laboratory operated by Battelle for the Department of Energy (DOE) under Contract DE-AC05-76RLO 1830.

59 BASIC BIOLOGICAL SCIENCES↗

A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Non-invasive authentication of mail packages using nuclear quadrupole resonance spectroscopy

The international postal network is one of the most widely used methods for correspondence throughout the world. Most postal traffic across the globe consists of legitimate interpersonal, business-consumer, and business-business communications. However, the global postal system is also utilized for criminal activity. In particular, it is often utilized to ship and distribute contraband, including illegal psychoactive drugs such as fentanyl and heroin, to consumers. Existing technological solutions are capable of identifying synthetic opioids and other illegal drugs within packages, but are accompanied by several disadvantages that make them unsuitable for large-scale authentication of international mail traffic. This paper presents a novel method for non-invasive authentication of mail packages that overcomes these challenges. The approach uses nuclear quadrupole resonance (NQR) spectroscopy to detect and quantify the presence of known active pharmaceutical ingredients (APIs) within the package. It has been experimentally demonstrated using a bench top prototype. Test results from a variety of package types demonstrate the effectiveness of the proposed authentication approach.

42 ENGINEERING↗

Periodicity significance testing with null-signal templates: reassessment of PTF’s SMBH binary candidates

Periodograms are widely employed for identifying periodicity in time series data, yet they often struggle to accurately quantify the statistical significance of detected periodic signals when the data complexity precludes reliable simulations. We develop a data-driven approach to address this challenge by introducing a null-signal template (NST). The NST is created by carefully randomizing the period of each cycle in the periodogram template, rendering it non-periodic. It has the same frequentist properties as a periodic signal template, and we show with simulations that the distribution of false positives is the same as with the original periodic template, regardless of the underlying data. Thus, performing a periodicity search with the NST acts as an effective simulation of the null (no-signal) hypothesis, without having to simulate the noise properties of the data. We apply the NST method to the supermassive black hole binaries (SMBHB) search in the Palomar Transient Factory (PTF), where Charisi et al. had previously proposed 33 high signal-to-noise candidates utilizing simulations to quantify their significance. Our approach reveals that these simulations do not capture the complexity of the real data. There are no statistically significant periodic signal detections above the non-periodic background. To improve the search sensitivity, we introduce a Gaussian quadrature based algorithm for the Bayes Factor with correlated noise as a test statistic. We show with simulations that this improves sensitivity to true signals by more than an order of magnitude. However, the Bayes Factor approach also results in no statistically significant detections in the PTF data.

79 ASTRONOMY AND ASTROPHYSICS↗

An empirical DNA-based identification of morphologically similar snappers (Lutjanus campechanus, Lutjanus purpureus) using a versatile bioinformatics workflow for the discovery and analysis of informative single-nucleotide polymorphisms

The commercially important speciesLutjanus campechanus(Northern/Gulf red snapper) andLutjanus purpureus(Southern/Caribbean red snapper) are the protagonists of a decade’s long taxonomic debate over their species delimitation, due in part to partial habitat overlap, extensive morphological similarity, and the lack of resolution when applying canonically reliable DNA barcoding approaches. In this study, we leveraged publicly available RAD-Seq data forL. campechanusandL. purpureusto identify species-informative single‐nucleotide polymorphisms (SNPs) at the genome scale that were successful in distinguishing the Northern and Southern red snappers, while also detecting individuals exhibiting introgression. This 4-step empirical approach demonstrates the value of applying novel bioinformatics pipelines to existing genome-scale data to maximize the distillation of informative subsets. Our results facilitate economically relevant species identification in addition to confirming or challenging species identifications for specimens with data in public databases. These findings and their applications will benefit future sustainability strategies and broader research questions surrounding these overfished and evolutionarily entangled snapper species.

Environmental Sciences & Ecology↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Click-Chemistry-Based Free Azide versus Azido Sugar Detection Enables Rapid In Vivo Screening of Glycosynthase Activity

Engineering of carbohydrate-active enzymes such as glycosynthases to enable chemoenzymatic synthesis of bespoke oligosaccharides has been limited by the lack of suitable ultrahigh-throughput screening methods capable of robustly detecting either starting substrates or end-products of the glycosidic bond formation reaction. Currently, there are limited screening methods available for rapid and highly sensitive single-cell-based screening of glycosynthase enzymes employing azido sugars as activated donor glycosyl substrates. Here, we report a fluorescence-based approach employing click-chemistry for the selective detection of glycosyl azides as substrates versus free inorganic azides as reaction products that facilitated an ultrahigh-throughput in vivo single-cell-based assay of glycosynthase activity. This assay was developed based on the distinct differences observed in relative fluorescence intensity of the triazole-containing fluorophore product formed during the click-chemistry reaction of organic glycosyl azides versus inorganic azides. This discovery formed the basis for proof of concept validation of a directed evolution methodology for screening and sorting glycosynthase mutants capable of synthesis of targeted fucosylated oligosaccharides. Our screening approach facilitated fluorescence-activated cell sorting of an error-prone polymerase chain reaction-based mutant library of fucosynthases expressed in Escherichia coli to identify several novel mutants that showed increased activity for ß-fucosyl azide-activated donor sugars toward desired acceptor sugars (e.g., pNP-xylose and lactose). Finally, we discuss avenues for improving this proof of concept in vivo assay method to identify better glycosynthase mutants and further demonstrate the broader applicability of this screening methodology for synthesis of bespoke glycans.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconstruction of β-Delayed Neutron Energy Spectra from Recoil-Ion Spectroscopy of Trapped Ions

Here Beta-delayed one-neutron (βn) emission has been investigated by confining radioactive ions in an ion trap and detecting the β particles and recoiling nuclei that emerge following decay. In this approach, the βn energy spectrum and branching ratio can be deduced without needing to detect the neutrons, as the neutron emission is inferred from the observed time of flight of the recoiling ions. This paper details the dominant effects that influence the extraction of the neutron energy from the time-of-flight measurement and explores the impact they have on the energy calibration and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗