Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Using neutral beams as a light ion beam probe (invited)

By arranging the particle first banana orbits to pass near a distant detector, the light ion beam probe (LIBP) utilizes orbital deflection to probe internal fields and field fluctuations. The LIBP technique takes advantage of (1) the in situ, known source of fast ions created by beam-injected neutral particles that naturally ionize near the plasma edge and (2) various commonly available diagnostics as its detector. These born trapped particles can traverse the plasma core on their inner banana leg before returning to the plasma edge. Orbital displacements (the forces on fast ions) caused by internal instabilities or edge perturbing fields appear as modulated signal at an edge detector. Adjustments in the q-profile and plasma shape that determine the first orbit, as well as the relative position of the source and detector, enable studies under a wide variety of plasma conditions. This diagnostic technique can be used to probe the impact on fast ions of various instabilities, e.g., Alfvén eigenmodes (AEs) and neoclassical tearing modes, and of externally imposed 3D fields, e.g., magnetic perturbations. To date, displacements by AEs and by externally applied resonant magnetic perturbation fields have been measured using a fast ion loss detector. Comparisons with simulations are shown. In addition, nonlinear interactions between fast ions and independent AE waves are revealed by this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the hohlraum radiation via one-end driven experiments

A new experiment is designed and performed on the Shenguang III laser facility with the first eight available beams to characterizing the hohlraum radiation, in which the hohlraum with laser entrance holes on both ends is driven through one-end only. The experiment enables us to identify the x-ray radiations originated from the hohlraum reemission wall and high-Z bubble plasmas utilizing their position and spectral characters, which provides a better test on the associated hohlraum models. The total and M-band x-ray radiation fluxes are measured with the flat response x-ray detectors and the filtered M-band x-ray detectors, respectively. Numerical simulations are conducted with the two-dimensional radiation hydrodynamic code LARED-INTEGRATION using the multi-group radiation transfer and/or diffusion models. It is found that the experimentally measured temporal profiles and angular distributions of hohlraum radiation are in good agreement with the predictions of simulation using radiation transfer models, but differ significantly from the results obtained with the multi-group radiation diffusion calculations. We thus note that to accurately represent the hohlraum radiation, a true radiation transfer model is essential.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Region-of-interest diffuse optical tomography system

Diffuse optical tomography (DOT) using near-infrared light is a promising tool for non-invasive imaging of deep tissue. This technique is capable of quantitative reconstruction of absorption (μ{sub a}) and scattering coefficient (μ{sub s}) inhomogeneities in the tissue. The rationale for reconstructing the optical property map is that the absorption coefficient variation provides diagnostic information about metabolic and disease states of the tissue. The aim of DOT is to reconstruct the internal tissue cross section with good spatial resolution and contrast from noisy measurements non-invasively. We develop a region-of-interest scanning system based on DOT principles. Modulated light is injected into the phantom/tissue through one of the four light emitting diode sources. The light traversing through the tissue gets partially absorbed and scattered multiple times. The intensity and phase of the exiting light are measured using a set of photodetectors. The light transport through a tissue is diffusive in nature and is modeled using radiative transfer equation. However, a simplified model based on diffusion equation (DE) can be used if the system satisfies following conditions: (a) the optical parameter of the inhomogeneity is close to the optical property of the background, and (b) μ{sub s} of the medium is much greater than μ{sub a} (μ{sub s} > > μ{sub a}). The light transport through a highly scattering tissue satisfies both of these conditions. A discrete version of DE based on finite element method is used for solving the inverse problem. The depth of probing light inside the tissue depends on the wavelength of light, absorption, and scattering coefficients of the medium and the separation between the source and detector locations. Extensive simulation studies have been carried out and the results are validated using two sets of experimental measurements. The utility of the system can be further improved by using multiple wavelength light sources. In such a scheme, the spectroscopic variation of absorption coefficient in the tissue can be used to arrive at the oxygenation changes in the tissue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FUNDAMENTAL PERFORMANCE OF A DISPERSED FIXED DELAY INTERFEROMETER IN SEARCHING FOR PLANETS AROUND M DWARFS

We present a new method to calculate fundamental Doppler measurement limits with a dispersed fixed delay interferometer (DFDI) in the near-infrared (NIR) wavelength region for searching for exoplanets around M dwarfs in the coming decade. It is based on calculating the Q factor, a measure of flux-normalized Doppler sensitivity in the fringing spectra created with DFDI. We calculate the Q factor as a function of spectral resolution R, stellar-projected rotational velocity Vsin i, stellar effective temperature T{sub eff}, and optical path difference (OPD) of the interferometer. We also compare the DFDI Q factor to that for the popular cross-dispersed echelle spectrograph method (the direct echelle (DE) method). We find that (1) Q{sub DFDI} is a factor of 1.5-3 higher than Q{sub DE} at R ranging from 5000 to 20,000; (2) Q{sub DFDI} and Q{sub DE} converge at a very high R (R {>=} 100,000); (3) Q{sub DFDI} increases as R increases and Vsin i deceases; (4) for a given R, Q{sub DFDI} increases as T{sub eff} drops from 3100 K to 2400 K (M4V to M9V). We also investigate how Q{sub DFDI} is affected by OPD and find that a 5 mm deviation from the optimal OPD does not significantly affect Q{sub DFDI} (10% or less) for a wide range of R. Given that the NIR Doppler measurement is likely to be detector-limited for a while, we introduce new merit functions, which is directly related to photon-limited radial velocity (RV) uncertainty, to evaluate Doppler performance with the DFDI and DE methods. We find that DFDI has strength in wavelength coverage and multi-object capability over the DE for a limited detector resource. We simulate the performance of the InfraRed Exoplanet Tracker (IRET) based on the DFDI design, being considered for the next generation IR Doppler measurements. The predicted photon-limited RV uncertainty suggests that IRET is capable of detecting Earth-like exoplanets in habitable zone around nearby bright M dwarfs if they exist. A new method is developed to quantitatively estimate the influence of telluric lines on RV uncertainty. Our study shows that photon-limited RV uncertainty can be reached if 99% of the strength of telluric lines can be removed from the measured stellar spectra. At low to moderate levels of telluric line strength removal (50%-90%), the optimal RV uncertainty is typically a factor of two to three times larger than photon-limited RV uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT replacements. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. Here, no dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the XENON1T low-energy electronic recoil excess using NEST

The search for dark matter, the missing mass of the Universe, is one of the most active fields of study within particle physics. The XENON1T experiment recently observed a 3.5⁢𝜎 excess potentially consistent with dark matter, or with solar axions. Here, we will use the Noble Element Simulation Technique (NEST) software to simulate the XENON1T detector, reproducing the excess. We utilize different detector efficiency and energy reconstruction models, but they primarily impact sub-keV energies and cannot explain the XENON1T excess. However, using NEST, we can reproduce their excess in multiple, unique ways, most easily via the addition of 31 ± 11 37 Ar decays. Furthermore, this results in new, modified background models, reducing the significance of the excess to ≤2.2⁢𝜎 at least using non-Profile Likelihood Ratio (PLR) methods. This is independent confirmation that the excess is a real effect, but potentially explicable by known physics. Many cross-checks of our 37 Ar hypothesis are presented.

particle dark matter↗

Measurement of Charged Pion Production Yields off the NuMI Target

The fixed-target MIPP experiment, Fermilab E907, was designed to measure the production of hadrons from the collisions of hadrons of momenta ranging from 5 to 120 GeV/c on a variety of nuclei. These data will generally improve the simulation of particle detectors and predictions of particle beam fluxes at accelerators. The spectrometer momentum resolution is between 3 and 4%, and particle identification is performed for particles ranging between 0.3 and 80 GeV/c using $dE/dx$, time-of-flight and Cherenkov radiation measurements. MIPP collected $1.42 \times10^6$ events of 120 GeV Main Injector protons striking a target used in the NuMI facility at Fermilab. The data have been analyzed and we present here charged pion yields per proton-on-target determined in bins of longitudinal and transverse momentum between 0.5 and 80 GeV/c, with combined statistical and systematic relative uncertainties between 5 and 10%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-G-IeP2-04: Dosimetric Accuracy of a Monte Carlo-Based Tool for Cone-Beam CT Organ Dose Calculation: Validation Against OSL and XRQA2 Film Measurements

Purpose: The intensive use of Cone-Beam Computed Tomography (CBCT) during radiotherapy treatments raise some questions about the dose to healthy tissues delivered during image acquisitions. We hence developed a Monte Carlo (MC)-based tool to predict doses to organs delivered by the Elekta XVI kV-CBCT. This work aims at assessing the dosimetric accuracy of the MC tool, in all tissue types. Methods: The kV-CBCT MC model was developed using the PENELOPE code. The beam properties were validated against measured lateral and depth dose profiles in water, and energy spectra measured with a CdTe detector. The CBCT simulator accuracy then required verification in clinical conditions. For this, we compared calculated and experimental dose values obtained with OSL nanoDots and XRQA2 films inserted in CIRS anthropomorphic phantoms (male, female, and 5-year old child). Measurements were performed at different locations, including bone and lung structures, and for several acquisition protocols: lung, head-and-neck, and pelvis. OSLs and film measurements were corrected when possible for energy dependence, by taking into account for spectral variations between calibration and measurement conditions. Results: Comparisons between measured and MC dose values are summarized in table 1. A mean difference of 8.6% was achieved for OSLs when the energy correction was applied, and 89.3% of the 84 dose points were within uncertainty intervals, including those in bones and lungs. Results with XRQA2 are not as good, because incomplete information about electronic equilibrium in film layers hampered the application of a simple energy correction procedure. Furthermore, measured and calculated doses (Fig.1) are in agreement with the literature. Conclusion: The MC-based tool developed was validated with an extensive set of measurements, and enables the organ dose calculation with accuracy. It can now be used to compute and report doses to organs for clinical cases, and also to drive strategies to optimize imaging protocols.

60 APPLIED LIFE SCIENCES↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Cosmic Ray Muon Tomography

This presentation discusses muons and their application in detectors, imaging and simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PMT Gain Calibration In MicroBooNE

Liquid argon (LAr) is an ideal scintillating detector medium: it is very bright, releasing O(10, 000) photons per MeV of deposited energy, and is also transparent to its own scintillation. Light data in liquid argon time projection chamber (LArTPC) experiments in general and MicroBooNE in particular has many important uses. In MicroBooNE, light collected over all photosensors is used as a first and second level trigger. At the data acquisition stage ~ 5PE is required for triggering. An additional software trigger of ≈ 20PE helps reject a large portion of cosmic ray background in events with no neutrino interaction occurring during the beam spill. Scintillation can also be used for the determination of absolute drift coordinate of non-beam related events. Additionally, matching reconstructed light to reconstructed TPC charge is a powerful tool for cosmic ray rejection. Finally due to the specific properties of LAr scintillation, light information can be used for particle identification. For many of these tasks good modeling of the light response of the detector is crucial. Applying data-driven corrections to optical detector data and simulation (prediction) allows to obtain a well calibrated energy scale from the PMTs. This reduces discrepancies between data and simulation, and calibrates out non-uniformities of data over the full data taking period. Thus it is expected to factor in improving systematic uncertainties on MicroBooNE’s flagship analyses - the low energy excess (LEE) search and LAr-ν cross-section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Fission Products at CARIBU: Near Field Detection (Q3/FY21 Quarterly Progress Report)

The overview of our project as well as most recent results have been presented at the NSARD review in April, and more recently during the WoNDRAM workshop. We have been dealing with recent personnel changes in the group. Miguel Bencomo, who has worked with us on this project as a postdoc at LLNL since 2019, will be terminating his appointment within the next two weeks to take a full-time appointment with Raytheon. We continue training our new team member Dan Hoff to take over data analysis from the last experiment we performed, as well as prepare for upcoming measurements. Additionally, we are working with a summer student, John Wilkinson, who is training to perform GEANT4 simulations of beta detector this summer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE Rucio Server Scalabiilty Studies

The DUNE collaboration has an ongoing production effort to simulate the full detectors and to analyze the various prototypes that are currently running. Rucio is used to manage the 40PB of files made to date. When 500 or more jobs were sending output to Rucio simultaneously via Rucio upload, we observed timeouts, unhandled exceptions, and Rucio server restarts due to slow performance. In collaboration with the core Rucio team we did a full review of the Rucio upload code and identified several optimizations that can be made. We also have deployed the Ingress load balancer in front of our Rucio servers and added a database connection pooling utility. These changes led to significant improvement both in reliability and scalability, yet we anticipate even better performance will eventually be required. We describe in this paper the initial state of the system, the various debugging processes that were used, and our plans to further improve scalability.

Calcutt, J. [Brookhaven Natl. Lab.]↗

A programmable CCD driver circuit for multiphase CCD operation

A programmable CCD (charge-coupled device) driver circuit was designed to drive CCDs in multiphased modes. The purpose of the drive electronics is to operate developmental CCD imaging arrays for NASA's tiltable moderate resolution imaging spectrometer (MODIS-T). Five objectives for the driver were considered during its design: (1) the circuit drives CCD electrode voltages between 0 V and +30 V to produce reasonable potential wells, (2) the driving sequence is started with one input signal, (3) the driving sequence is started with one input signal, (4) the circuit allows programming of frame sequences required by arrays of any size, (5) it produces interfacing signals for the CCD and the DTF (detector test facility). Simulation of the driver verified its function with the master clock running up to 10 MHz. This suggests a maximum rate of 400,000 pixels/s. Timing and packaging parameters were verified. The design uses 54 TTL (transistor-transistor logic) chips. Two versions of hardware were fabricated: wirewrap and printed circuit board. Both were verified functionally with a logic analyzer.

Ewin, Audrey J.↗

Monte Carlo Shower Counter Studies

Activities and accomplishments related to the Monte Carlo shower counter studies are summarized. A tape of the VMS version of the GEANT software was obtained and installed on the central computer at Gallaudet University. Due to difficulties encountered in updating this VMS version, a decision was made to switch to the UNIX version of the package. This version was installed and used to generate the set of data files currently accessed by various analysis programs. The GEANT software was used to write files of data for positron and proton showers. Showers were simulated for a detector consisting of 50 alternating layers of lead and scintillator. Each file consisted of 1000 events at each of the following energies: 0.1, 0.5, 2.0, 10, 44, and 200 GeV. Data analysis activities related to clustering, chi square, and likelihood analyses are summarized. Source code for the GEANT user subprograms and data analysis programs are provided along with example data plots.

Snyder, H. David↗

ANTARES Constrains a Blazar Origin of Two IceCube PeV Neutrino Events

Context. The source(s) of the neutrino excess reported by the IceCube Collaboration is unknown. The TANAMI Collaboration recently reported on the multiwavelength emission of six bright, variable blazars which are positionally coincident with two of the most energetic IceCube events. Objects like these are prime candidates to be the source of the highest-energy cosmic rays, and thus of associated neutrino emission. Aims. We present an analysis of neutrino emission from the six blazars using observations with the ANTARES neutrino telescope. Methods. The standard methods of the ANTARES candidate list search are applied to six years of data to search for an excess of muons - and hence their neutrino progenitors - from the directions of the six blazars described by the TANAMI Collaboration, and which are possibly associated with two IceCube events. Monte Carlo simulations of the detector response to both signal and background particle fluxes are used to estimate the sensitivity of this analysis for di erent possible source neutrino spectra. A maximum-likelihood approach, using the reconstructed energies and arrival directions of through-going muons, is used to identify events with properties consistent with a blazar origin. Results. Both blazars predicted to be the most neutrino-bright in the TANAMI sample (1653-329 and 1714-336) have a signal flux fitted by the likelihood analysis corresponding to approximately one event. This observation is consistent with the blazar-origin hypothesis of the IceCube event IC 14 for a broad range of blazar spectra, although an atmospheric origin cannot be excluded. No ANTARES events are observed from any of the other four blazars, including the three associated with IceCube event IC20. This excludes at a 90% confidence level the possibility that this event was produced by these blazars unless the neutrino spectrum is flatter than -2.4.

general↗

Absorber Optimization Study for the Terahertz Intensity Mapper (TIM)

We discuss the design and optimization of the absorber for the long-wavelength arm of the Terahertz Intensity Mapper (TIM), a balloon-borne spectrometer employing Kinetic Inductance Detectors (KIDs). Electromagnetic simulations of our design indicate in-band absorption efficiency over 80% in both linear polarization modes. By developing custom transmission line model and mode-matching calculations, we find the absorption efficiency is affected by the absorber’s reactive part and overall shape. These insights into the operation of this design provide guidance for its optimization for low-resistance absorber. materials.

Nie, Rong↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage [1] with over 2,000 casks already loaded [2]. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980s. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies’ location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988 [3]. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield [4]. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis [5] [6] [7], rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗