Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffraction limited”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Synchrotron X-Ray Diffraction Studies of Olivine from Comet Wild 2

We have analyzed a collection of the Comet Wild 2 coma grains returned by the NASA Stardust Mission, using micro-area Laue diffraction equipment. The purpose of the diffraction experiment is to permit the structure refinement of olivine including site occupancies. In addition to the intrinsic importance of the olivine structures for revealing the thermal history of Wild 2 materials, we wish to test reports that olivine recovered after hypervelocity capture in silica aerogel has undergone a basic structural change due to capture heating [1]. The diffraction equipment placed at beam line BL- 4B1 of PF, KEK was developed with a micropinhole and an imaging plate (Fuji Co. Ltd.) using the Laue method combined with polychromatic X-ray of synchrotron radiation operated at energy of 2.5 GeV. The incident beam is limited to 1.6 m in diameter by a micropinhole set just upstream of the sample [2, 3]. It is essential to apply a microbeam to obtain diffracted intensities with high signal to noise ratios. This equipment has been successfully applied to various extraterrestrial materials, including meteorites and interplanetary dust particles [4]. The Laue pattern of the sample C2067,1,111,4 (Fig. 1) was successfully taken on an imaging plate after a 120 minute exposure (Fig. 2).

Source record↗

Transmission media effects on precise Doppler tracking

The effects of the transmission media - the earth's troposphere and ionosphere, and the solar wind - on precise Doppler tracking are discussed. The charged particle effects can be largely removed by dual frequency observations; however there are limitations to these corrections (besides system noise and/or finite integration times) including the effects of magnetic fields, diffraction, and differential refraction, all of which must be carefully evaluated. The earth's troposphere can contribute an error of delta f/f approximately 10 to the minus 14th power.

Callahan, P. S.↗

A comparison between GO/aperture-field and physical-optics methods for offset reflectors

Both geometrical optics (GO)/aperture-field and physical-optics (PO) methods are used extensively in the diffraction analysis of offset parabolic and dual reflectors. An analytical/numerical comparative study is performed to demonstrate the limitations of the GO/aperture-field method for accurately predicting the sidelobe and null positions and levels. In particular, it is shown that for offset parabolic reflectors and for feeds located at the focal point, the predicted far-field patterns (amplitude) by the GO/aperture-field method will always be symmetric even in the offset plane. This, of course, is inaccurate for the general case and it is shown that the physical-optics method can result in asymmetric patterns for cases in which the feed is located at the focal point. Representative numerical data are presented and a comparison is made with available measured data.

Rahmat-Samii, Y.↗

Stellar occultation probes of the Uranian rings at 0.1 and 2.2 microns - A comparison of Voyager UVS and earth-based results

A comparison between Voyager 2 UV spectrometer data for stellar occultations of the Uranian ring system obtained at 0.11 microns and 2.2-micron earth-based occultation data reveals the anticipated factor-of-two reduction in observed optical depths relative to those observed from earth. This is due to Voyager's proximity to the rings, which allows light diffracted out of the direct beam by ring particles to be replaced by light diffracted into the direct beam light from other particles, and further permits the placing of firm lower limits on typical particle sizes of 0.3 and 1 cm for the epsilon and delta rings, respectively. As a function of true anomaly, the epsilon ring profile is noted to remain very similar in shape and essentially constant in equivalent depth, even very near periapse.

Holberg, J. B.↗

Two-color method for optical astrometry - Theory and preliminary measurements with the Mark III stellar interferometer

The two-color method for interferometric astrometry provides a means of reducing the error in a stellar position measurement attributable to atmospheric turbulence. The primary limitation of the method is shown to be turbulent water vapor fluctuations. Secondary atmospheric effects caused by diffraction from small refractive-index inhomogeneities and differential refraction for the observation of stars away from zenith are shown to introduce errors that behave as white noise and which should not be significant. Other potential error sources due to photon noise, systematic instrumental effects, and imperfect data reduction are also considered. The improvement in accuracy possible with the two-color method is estimated as a factor of 5-10 over the corresponding one-color measurement. Some preliminary two-color measurements with the Mark III stellar interferometer at Mt. Wilson are presented, which demonstrate a factor of about 5 reduction in the amplitude of the atmospheric fluctuations in a stellar position measurement.

Colavita, M. Mark↗

The laser elevator - Momentum transfer using an optical resonator

In a conventional laser lightsail system the payload is propelled by the momentum imparted to it by the reflection of a laser beam without the use of any propellant. Because of the unfavorable relationship between energy and momentum in a light beam, these systems are very inefficient. The efficiency can be greatly improved, in principle, if the photons that impact the payload mirror are returned to the source and then redirected back toward the payload again. This system, which recirculates the laser beam, is defined as the 'laser elevator'. The gain of the laser elevator over conventional lightsails depends on the number of times the beam is recycled which is limited by the reflectance of the mirrors used, any losses in the transmission of the beam, and diffraction. Due to the increase pathlength of the folded beam, diffraction losses occur at smaller separations of the payload and the source mirror than for conventional lightsail system. The laser elevator has potential applications in launching to low earth orbit, orbital transfer, and rapid interplanetary delivery of small payloads.

Meyer, Thomas R.↗

Human serum albumin crystals and method of preparation

Human serum albumin (HSA) crystals are provided in the form of tetragonal plates having the space groups P42(sub 1)2, the crystals being grown to sizes in excess of 0.5 mm in two dimensions and a thickness of 0.1 mm. Growth of the crystals is carried out by a hanging drop method wherein a precipitant solution containing polyethylene glycol (PEG) and a phosphate buffer is mixed with an HSA solution, and a droplet of mixed solution is suspended over a well of precipitant solution. Crystals grow to the desired size in 3 to 7 days. Concentration of reagents, pH and other parameters are controlled within prescribed limits. The resulting crystals exhibit a size and quality such as to allow performance of x ray diffraction studies and enable the conduct of drug binding studies as well as genetic engineering studies.

Carter, Daniel C.↗

Ray Scattering by an Arbitrarily Oriented Spheroid: 2. Transmission and Cross-polarization Effects

Transmission of an arbitrarily polarized plane wave by an arbitrarily oriented spheroid in the short-wavelength limit is considered in the context of ray theory. The transmitted electric field is added to the diffracted plus reflected ray-theory electric field that was previously derived to obtain an approximation to the far-zone scattered intensity in the forward hemisphere. Two different types of cross-polarization effects are found. These are: (a) a rotation of the polarization state of the transmitted rays from when they are referenced with respect to their entrance into the spheroid to when they are referenced with respect to their exit from it and (b) a rotation of the polarization state of the transmitted rays when they are referenced with respect to the polarization state of the diffracted plus reflected rays.

Lock, James A.↗

Crystallization and initial X-ray diffraction analysis of human pyruvate dehydrogenase

Human pyruvate dehydrogenase (E1) is a component enzyme of the pyruvate dehydrogenase complex. The enzyme catalyzes the irreversible decarboxylation of pyruvic acid and the rate-limiting reductive acetylation of the lipoyl moiety linked to the dihydrolipoamide acetyltransferase component of the pyruvate dehydrogenase complex. E1 is an alpha(2)beta(2) tetramer ( approximately 154 kDa). Crystals of this recombinant enzyme have been grown in polyethylene glycol 3350 using a vapor-diffusion method at 295 K. The crystals are characterized as orthorhombic, space group P2(1)2(1)2(1), with unit-cell parameters a = 64.2, b = 126.9, c = 190.2 A. Crystals diffracted to a minimum d spacing of 2.5 A. The asymmetric unit contains one alpha(2)beta(2) tetrameric E1 assembly; self-rotation function analysis showed a pseudo-twofold symmetry relating the two alphabeta dimers.

Pyruvate Dehydrogenase Complex/chemistry↗

Alignment Cube with One Diffractive Face

An enhanced alignment cube has been invented for use in a confined setting (e.g., a cryogenic chamber) in which optical access may be limited to a single line of sight. Whereas traditional alignment-cube practice entails the use of two theodolites aimed along two lines of sight, the enhanced alignment cube yields complete alignment information through use of a single theodolite aimed along a single line of sight. Typically, an alignment cube is placed in contact with a datum surface or other reference feature on a scientific instrument during assembly or testing of the instrument. The alignment cube is then used in measuring a small angular deviation of the feature from a precise required orientation. Commonly, the deviation is expressed in terms of rotations (Rx,Ry,Rz) of the cube about the corresponding Cartesian axes (x,y,z). In traditional practice, in order to measure all three rotations, it is necessary to use two theodolites aimed at two orthogonal faces of the alignment cube, as shown in the upper part of the figure. To be able to perform such a measurement, one needs optical access to these two faces. In the case of an alignment cube inside a cryogenic chamber or other enclosed space, the optical-access requirement translates to a requirement for two windows located along the corresponding two orthogonal lines of sight into the chamber. In a typical application, it is difficult or impossible to provide two windows. The present enhanced version of the alignment cube makes it possible to measure all three rotations by use of a single line of sight, thereby obviating a second window.

Ohl, Raymond G.↗

Investigation of the Surface Stress in SiC and Diamond Nanocrystals by In-situ High Pressure Powder Diffraction Technique

The real atomic structure of nanocrystals determines key properties of the materials. For such materials the serious experimental problem lies in obtaining sufficiently accurate measurements of the structural parameters of the crystals, since very small crystals constitute rather a two-phase than a uniform crystallographic phase system. As a result, elastic properties of nanograins may be expected to reflect a dual nature of their structure, with a corresponding set of different elastic property parameters. We studied those properties by in-situ high-pressure powder diffraction technique. For nanocrystalline, even one-phase materials such measurements are particularly difficult to make since determination of the lattice parameters of very small crystals presents a challenge due to inherent limitations of standard elaboration of powder diffractograms. In this investigation we used our methodology of the structural analysis, the 'apparent lattice parameter' (alp) concept. The methodology allowed us to avoid the traps (if applied to nanocrystals) of standard powder diffraction evaluation techniques. The experiments were performed for nanocrystalline Sic and GaN powders using synchrotron sources. We applied both hydrostatic and isostatic pressures in the range of up to 40 GPa. Elastic properties of the samples were examined based on the measurements of a change of the lattice parameters with pressure. The results show a dual nature of the mechanical properties (compressibilities) of the materials, indicating a complex, core-shell structure of the grains.

Palosz, B.↗

Experimental investigations of elastohydrodynamic lubrication

Various experimental studies of elastohydrodynamic lubrication have been reviewed. The various types of machines used in these investigations, such as the disc, two and four ball, crossed-cylinders, and crossed-axes rolling disc machine, are described. The measurement of the most important parameters, such as film shape, film thickness, pressure, temperature, and traction, is considered. Determination of the film thickness is generally the most important of these effects since it dictates the extent to which the asperities on opposing surfaces can come into contact and thus has a direct bearing on wear and fatigue failure of the contacting surfaces. Several different techniques for measuring film thickness have been described, including electrical resistance, capacitance, X-ray, optical interferometry, laser beam diffraction, strain gage, and spring dynamometer methods. An attempt has been made to describe the basic concepts and limitations of each of these techniques. These various methods have been used by individual researchers, but there is no universally acceptable technique for measuring elastohydrodynamic film thickness. Capacitance methods have provided most of the reliable data for nominal line or rectangular conjunctions, but optical interferometry has proved to be the most effective procedure for elliptical contacts. Optical interferometry has the great advantage that it reveals not only the film thickness, but also details of the film shape over the complete area of the conjunction.

Hamrock, B. J.↗

Scattering of sound by atmospheric turbulence predictions in a refractive shadow zone

According to ray theory, regions exist in an upward refracting atmosphere where no sound should be present. Experiments show, however, that appreciable sound levels penetrate these so-called shadow zones. Two mechanisms contribute to sound in the shadow zone: diffraction and turbulent scattering of sound. Diffractive effects can be pronounced at lower frequencies but are small at high frequencies. In the short wavelength limit, then, scattering due to turbulence should be the predominant mechanism involved in producing the sound levels measured in shadow zones. No existing analytical method includes turbulence effects in the prediction of sound pressure levels in upward refractive shadow zones. In order to obtain quantitative average sound pressure level predictions, a numerical simulation of the effect of atmospheric turbulence on sound propagation is performed. The simulation is based on scattering from randomly distributed scattering centers ('turbules'). Sound pressure levels are computed for many realizations of a turbulent atmosphere. Predictions from the numerical simulation are compared with existing theories and experimental data.

Mcbride, Walton E.↗

The Selection of Q-Switch for a 350mJ Air-borne 2-micron Wind Lidar

In the process of designing a coherent, high energy 2micron, Doppler wind Lidar, various types of Q-Switch materials and configurations have been investigated for the oscillator. Designing an oscillator with a relatively low gain laser material, presents challenges related to the management high internal circulating fluence due to high reflective output coupler. This problem is compounded by the loss of hold-off. In addition, the selection has to take into account the round trip optical loss in the resonator and the loss of hold-off. For this application, a Brewster cut 5mm aperture, fused silica AO Q-switch is selected. Once the Q-switch is selected various rf frequencies were evaluated. Since the Lidar has to perform in single longitudinal and transverse mode with transform limited line width, in this paper, various seeding configurations are presented in the context of Q-Switch diffraction efficiency. The master oscillator power amplifier has demonstrated over 350mJ output when the amplifier is operated in double pass mode and higher than 250mJ when operated in single pass configuration. The repetition rate of the system is 10Hz and the pulse length 200ns.

Petros, Mulugeta↗

Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

Archilles, Cherie↗

Gratings and Random Reflectors for Near-Infrared PIN Diodes

Crossed diffraction gratings and random reflectors have been proposed as means to increase the quantum efficiencies of InGaAs/InP positive/intrinsic/ negative (PIN) diodes designed to operate as near-infrared photodetectors. The proposal is meant especially to apply to focal-plane imaging arrays of such photodetectors to be used for near-infrared imaging. A further increase in quantum efficiency near the short-wavelength limit of the near-infrared spectrum of such a photodetector array could be effected by removing the InP substrate of the array. The use of crossed diffraction gratings and random reflectors as optical devices for increasing the quantum efficiencies of quantum-well infrared photodetectors (QWIPs) was discussed in several prior NASA Tech Briefs articles. While the optical effects of crossed gratings and random reflectors as applied to PIN photodiodes would be similar to those of crossed gratings and random reflectors as applied to QWIPs, the physical mechanisms by which these optical effects would enhance efficiency differ between the PIN-photodiode and QWIP cases: In a QWIP, the multiple-quantum-well layers are typically oriented parallel to the focal plane and therefore perpendicular or nearly perpendicular to the direction of incidence of infrared light. By virtue of the applicable quantum selection rules, light polarized parallel to the focal plane (as normally incident light is) cannot excite charge carriers and, hence, cannot be detected. A pair of crossed gratings or a random reflector scatters normally or nearly normally incident light so that a significant portion of it attains a component of polarization normal to the focal plane and, hence, can excite charge carriers. A pair of crossed gratings or a random reflector on a PIN photodiode would also scatter light into directions away from the perpendicular to the focal plane. However, in this case, the reason for redirecting light away from the perpendicular is to increase the length of the optical path through the detector to increase the probability of absorption of photons and thereby increase the resulting excitation of charge carriers. A pair of crossed gratings or a random reflector according to the proposal would be fabricated as an integral part of photodetector structure on the face opposite the focal plane (see figure). In the presence of crossed gratings, light would make four passes through the device before departing. In the presence of a random reflector, a significant portion of the light would make more than four passes: After each bounce, light would be scattered at a different random angle, and would have a chance to escape only when it was reflected, relative to the normal, at an angle less than the critical angle for total internal reflection. Given the indices of refraction of the photodiode materials, this angle would be about 17 . This amounts to a very narrow cone for escape of trapped light.

Gunapala, Sarath↗

Extension of Subreflector Increases Antenna Efficiency

According to calculations, efficiency of offset Cassegrain reflector antenna increased by about 8 percent by extending edge of subreflector outward about 1 wavelength beyond optical limit. Even though main reflector partially shadowed by subreflector, partial aperture blockage more than offset by consequent reduction of diffraction on subreflector. Similar conclusions apply to symmetric Cassegrain antennas.

Rahmat-Samii, Y.↗

A New Optical Aerosol Spectrometer

An optical particle spectrometer capable of measuring aerosol particle size distributions from 0.02 to 100 micrometers has been developed. This instrument combines several optical methods in one, in-situ configuration; it can provide continuous data collection to encompass the wide dynamic size ranges and concentrations found in studies of modeled planetary atmospheres as well as terrestrial air quality research. Currently, the system is incorporated into an eight liter capacity spherical pressure vessel that is appropriate both for flowthrough and for in-situ particle generation. The optical sizing methods include polarization ratio, The scattering, and forward scattering detectors, with illumination from a fiber-coupled, Argon-ion laser. As particle sizes increase above 0.1 micrometer, a customized electronics and software system automatically shifts from polarization to diffraction-based measurements as the angular scattering detectors attain acceptable signal-to-noise ratios. The number concentration detection limits are estimated to be in the part-per-trillion (ppT by volume) range, or roughly 1000 submicron particles per cubic centimeter. Results from static experiments using HFC134A (approved light scattering gas standard), flow-through experiments using sodium chloride (NaCl) and carbon particles, and dynamic 'Tholin' (photochemical produced particles from ultraviolet (UV)-irradiated acetylene and nitrogen) experiments have been obtained. The optical spectrometer data obtained with particles have compared well with particle sizes determined by electron microscopy. The 'Tholin' tests provided real-time size and concentration data as the particles grew from about 30 nanometers to about 0.8 micrometers, with concentrations ranging from ppT to ppB, by volume. Tests are still underway, to better define sizing accuracy and concentration limits, these results will be reported.

Fonda, Mark↗