Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dose Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-F-T-578: Characterization of Vidar DosimetryPro Advantage RED Scanner with Application to SBRT and SRS QA

Purpose: To use Gafchromic EBT3 film to quantify key dosimetric characteristics of the Vidar DosimetryPro Advantage RED film scanner for use in SBRT/SRS QA, by analyzing scanner uniformity and dose sensitivity. Method: Gafchromic EBT3 film was used in this study. Films were irradiated using 6MV FFF and 10MV FFF beams from a Varian Edge linear accelerator, with setup of 100cm SAD at depth 5 cm. Nine doses were delivered per film, with calibration dose ranges of 1–10 Gy and 3–24 Gy for 6MV FFF, and 3–27 Gy for 10MV FFF. Films were scanned with the long side of the film parallel to the detector array. Dose calibration curves were fitted to a 3rd degree polynomial. The derivative of a calibration curve was taken to determine the scanner’s sensitivity per dose delivered (OD/Gy). Scanner non-uniformity was calculated in 2 dimensions by taking the mean of standard deviation in each row and column. Absolute dose SRS/SBRT Gamma analyses were performed with passing criteria of 3% and 1mm DTA. For comparison, Gamma analyses were also performed using an Epson Expression 10000 XL. Results: Uniformity for the Vidar scanner was 0.37% +/− 0.03% in the perpendicular to scan direction and 0.67% +/− 0.05% in the parallel to scan direction, with an overall uniformity of 0.52% +/− 0.03%. Epson red channel uniformity was 0.85% +/− 0.05% and 0.88% +/− 0.08% for the green channel. The Vidar average dose sensitivity from 1–10 Gy was 0.112 OD/Gy and 0.061 OD/Gy for 3–24 Gy. SBRT/SRS Gamma pass rates were 97.8 +/− 1.4 for Vidar and 97.5 +/− 1.4 for Epson. Conclusion: The Vidar scanner has 41% less non-uniformity compared to Epson XL10000 green channel. The dose sensitivity is 2–3 time greater for the Vidar scanner compared to the Epson in the SRS/SBRT dose range of 5–24 Gy.

60 APPLIED LIFE SCIENCES↗

Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce the electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. As a result, the use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO 3 , a material that is traditionally difficult to image by TEM/STEM because of dose issues.

36 MATERIALS SCIENCE↗

SU-G-TeP4-05: An Evaluation of a Low Dose Rate (LDR) Prostate Brachytherapy Procedure Using a Failure Modes and Effects Analysis (FMEA)

Purpose: The aim of the study is the application of a Failure Modes and Effects Analysis (FMEA) to access the risks for patients undergoing a Low Dose Rate (LDR) Prostate Brachytherapy Treatment. Methods: FMEA was applied to identify all the sub processes involved in the stages of identifying patient, source handling, treatment preparation, treatment delivery, and post treatment. These processes characterize the radiation treatment associated with LDR Prostate Brachytherapy. The potential failure modes together with their causes and effects were identified and ranked in order of their importance. Three indexes were assigned for each failure mode: the occurrence rating (O), the severity rating (S), and the detection rating (D). A ten-point scale was used to score each category, ten being the number indicating most severe, most frequent, and least detectable failure mode, respectively. The risk probability number (RPN) was calculated as a product of the three attributes: RPN = O X S x D. The analysis was carried out by a working group (WG) at UPMC. Results: The total of 56 failure modes were identified including 32 modes before the treatment, 13 modes during the treatment, and 11 modes after the treatment. In addition to the protocols already adopted in the clinical practice, the prioritized risk management will be implanted to the high risk procedures on the basis of RPN score. Conclusion: The effectiveness of the FMEA method was established. The FMEA methodology provides a structured and detailed assessment method for the risk analysis of the LDR Prostate Brachytherapy Procedure and can be applied to other radiation treatment modes.

60 APPLIED LIFE SCIENCES↗

Ion-Neutron Irradiated BOR60 Sample Preparation and Characterization: Nuclear Science User Facility 2017 Milestone Report

This document outlines the results obtained by Oak Ridge National Laboratory (ORNL) in collaboration with the University of Michigan-led Consolidated Innovative Nuclear Research project, “Feasibility of combined ion-neutron irradiation for accessing high dose levels.” In this reporting period, neutron irradiated were prepared and shipped to the University of Michigan for subsequent ion irradiation. The specimens were returned to ORNL’s Low Activation Materials Development and Analysis facility, prepared via focused ion beam for examination using scanning/transmission electron microscopy (S/TEM), and then examined using S/TEM to measure the as-irradiated microstructure. This report briefly summarizes the S/TEM results obtained at ORNL’s Low Activation Materials Development and Analysis facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Changes in Plants Developed from Imbibed Seeds Irradiated by Simulated Solar Particle Events

One of the major concerns for long-term exploration missions beyond the Earth’s magnetosphere is radiation risk primarily from solar particle events (SPEs) and galactic cosmic rays (GCRs). With the goal of enabling manned Mars exploration, the production of fresh food during long duration space missions may provide nutritional supplementation and benefit astronauts’ behavioral health. However, the effects of space radiation on plants and plant propagules have not been sufficiently investigated and characterized. In this study, we evaluated the effect of simulated SPEs on imbibed seeds of mizuna mustard, ‘Outredgeous’ red romaine lettuce, and ‘Red Robin’ dwarf tomato. Seeds were exposed to various doses of simulated SPEs (0, 40, 80 cGy, and 200 cGy), either acutely or at a low dose rate (LDR only for 40 and 80 cGy doses), using the NASA Space Radiation Laboratory (NSRL) facility at Brookhaven National Lab (BNL). Simulated SPE exposure was achieved using sequential exposures to protons with a broad energy range at 50-150 MeV/n. Control and irradiated seeds were planted either onto 0.5% MS-based agar plates containing required nutrients for early seedling analysis, or in peat plugs/pots for 28 day (mizuna and lettuce) and 91 day (tomato) grow outs. All plants were maintained under space-vehicle relevant conditions at 3000 ppm CO2, 50% RH, and 23°C, and a 16/8 h photoperiod with 300 μmol·m(exp -2)·s(exp -1) photosynthetically active radiation. Plant/fruit morphometrics and edible fresh mass were measured. Additionally, nutrient analyses were performed on mizuna and tomato fruit. Seedlings from irradiated seeds (both 40 and 80 cGy) showed significant and dose dependent impacts on cotyledon development and root length. Interestingly, small, but significant changes in vitamin content were found in mizuna and tomato fruits grown from 80 cGy (LDR) irradiated seeds. In addition, 80 cGy (LDR) simulated SPEs significantly delayed tomato early seedling development and plant growth, and reduced the quantity of fruits produced from the surviving plants. (This study was supported by NASA Human Research Program.)

J. T. Richards↗

Changes in Plants Developed from Imbibed Seeds Irradiated by Simulated Solar Particle Events

One of the major concerns for long-term exploration missions beyond the Earth’s magnetosphere is radiation risk primarily from solar particle events (SPEs) and galactic cosmic rays (GCRs). With the goal of manned Mars exploration, the production of fresh food during long duration space missions may provide nutritional supplementation and benefit astronauts’ behavioral health. However, the effects of space radiation on plants and plant propagules have not been sufficiently investigated and characterized. In this study, we evaluated the effect of simulated SPEs on imbibed seeds of mizuna mustard, ‘Outredgeous’ red romaine lettuce, and ‘Red Robin’ dwarf tomato. Seeds were exposed to various doses of simulated SPEs (0, 40, 80 cGy, and 200 cGy), either acutely or at a low dose rate (LDR only for 40 and 80 cGy doses), using the NASA Space Radiation Laboratory (NSRL) facility at Brookhaven National Lab (BNL). Simulated SPE exposure was achieved using sequential exposures to protons with a broad energy range at 50-150 MeV/n. Control and irradiated seeds were planted either onto 0.5% MS-based agar plates containing required nutrients for early seedling analysis, or in peat plugs/pots for 28 day (mizuna and lettuce) and 91 day (tomato) grow outs. All plants were maintained under space-vehicle relevant controlled environment conditions at 3000 ppm CO2, 50% RH, and 23°C, and a 16/8 h photoperiod with 300 μmol·m-2·s-1 photosynthetically active radiation. Plant/fruit morphometrics and edible fresh mass were measured. In addition, nutrient analyses were performed for both mizuna and ripe tomatoe fruit. Seedlings from irradiated seeds (both 40 cGy and 80 cGy) showed significant changes in cotyledon development, as well as root length. Interestingly, small, but significant changes in vitamin content were found in mizuna and tomato fruits grown from 80 cGy (LDR) irradiated seeds. In addition, 80 cGy (LDR) simulated SPEs significantly affected tomato early seedling development, plant growth, and the quantity of fruits produced from the surviving plants. Generally, compared to 80 cGy, 40 cGy (LDR) of simulated SPEs displayed some impacts to the seeds and seedlings, but to a much lesser degree. (This study was supported by NASA Human Research Program.)

J.T. Richards↗

Changes in Plants Developed from Imbibed Seeds Irradiated by Simulated Solar Particle Events

One of the major concerns for long-term exploration missions beyond the Earth’s magnetosphere is radiation risk primarily from solar particle events (SPEs) and galactic cosmic rays (GCRs). With the goal of manned Mars exploration, the production of fresh food during long duration space missions may provide nutritional supplementation and benefit astronauts’ behavioral health. However, the effects of space radiation on plants and plant propagules have not been sufficiently investigated and characterized. In this study, we evaluated the effect of simulated GCRs on dry seeds of mizuna mustard, ‘Outredgeous’ red romaine lettuce, and ‘Red Robin’ dwarf tomato. Seeds were exposed to various doses of simulated GCRs (0, 40, and 80 cGy), either acutely or at a low dose rate (LDR), using the NASA Space Radiation Laboratory (NSRL) facility at Brookhaven National Lab (BNL). Control and irradiated seeds were planted and maintained under space-vehicle relevant controlled environment conditions. Plant/fruit morphometrics and edible fresh mass were measured. In addition, nutrient analyses were performed for both mizuna and ripe tomatoe fruit. Seedlings from irradiated seeds (both 40 cGy and 80 cGy) showed significant changes in cotyledon development, but not in root length or morphology. Interestingly, significant changes in vitamin content were found in mizuna grown from 80 cGy (LDR) irradiated seeds. In addition, 80 cGy (LDR) simulated GCRs significantly affected lettuce and tomato seed quality, delayed tomato fruiting, and reduced the total yield of tomato. Generally, compared to 80 cGy, 40 cGy (LDR) of simulated GCRs displayed some impacts to the seeds and seedlings, but to a much lesser degree. (This study was supported by NASA Human Research Program.)

J.T. Richards↗

Neutron damage and recovery studies of SiPMs

SiPM lost its performance characteristics when exposed to hig dose of neutrons. However, the distinct hallmark of SiPMs, low dark count and excellent photon-number-resolving capability, can be recovered by thermal annealing. Several SiPMs from different vendors are characterized before and after exposure of up to 1010 neutron/cm2 dosage using a 14 MeV neutron generation source. Collectively, we established that the typical orders of magnitude increase in dark current upon neutron irradiation can be lowered substantially after processing them with a thermal annealing procedure, and single-photon detection are to some extent recovered. Moreover, we found no significant difference on neutron damaged behavior when SiPMs are irradiated at room or liquid nitrogen temperatures suggesting that there is no evidence of radiation hardening when SiPMs are operated in cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oculometric Detection and Characterization of Sub-Clinical Visual/Visuomotor Impairment

It has long been known that qualitative abnormalities in eye movements can be used to diagnose overt brain pathologies (Diefendorf & Dodge, 1908; Fox & Holmes, 1926; Leigh & Zee, 2015). Here, we will examine the use of a set of quantitative measures of the human behavioral response (oculometrics) in a 5-minute radial ocular tracking task (Krukowski & Stone, 2005) with sufficient temporal, spatial, and directional uncertainty to minimize the contribution of a priori prediction or anticipation, and to emphasize the use of a posteriori visual processing of the stimulus trajectory (Liston & Stone, 2014). The derived oculometrics provide a largely independent, reliable set of metrics that are sensitive enough to detect mild sub-clinical impairment across a range of possible neural loci (Stone et al., 2019) with the pattern of impairment across the set providing specificity as to its nature (Tyson et al., 2023). We will review our earlier findings where oculometrics have been used to detect mild impairment due to traumatic brain injury, sleep loss, and low-dose alcohol (Liston et al., 2017; Stone et al., 2019; Tyson et al., 2021). We will also report on a recent clinical study of asymptomatic patients at risk of retinal pathology (Leung et al., 2022) and show that oculometrics can detect and characterize substantive loss of visual function in the absence of clinical indicators of pathology. We conclude that oculometric testing could be used as a routine non-invasive ophthalmological or neurological tool to aid in the early detection and diagnosis of neural injury, toxicity, or disease.

eye movements↗

SU-F-T-138: Commissioning and Evaluating Dose Computation Models for a Dedicated Proton Line Scanning Beam Nozzle in Eclipse Treatment Planning System

Purpose: In this study, we present an effective method to derive low dose envelope of the proton in-air spot fluence at beam positions other than the isocenter to reduce amount of measurements required for planning commission. Also, we demonstrate commissioning and validation results of this method to the Eclipse treatment planning system (version 13.0.29) for a Sumitomo dedicated proton line scanning beam nozzle. Methods: The in-air spot profiles at five beam-axis positions (±200, ±100 and 0 mm) were obtained in trigger mode using a MP3 Water tank (PTW-Freiburg) and a pinpoint ionization chamber (model 31014, PTW-Freiburg). Low dose envelope (below 1% of the center dose) of the spot profile at isocenter was obtained by repeated point measurements to minimize dosimetry uncertainty. The double Gaussian (DG) model was used to fit and obtain optimal σ1, σ2 and their corresponding weightings through our in-house MATLAB (Mathworks) program. σ1, σ2 were assumed to expand linearly along the beam axis from a virtual source position calculated by back projecting fitted sigmas from the single Gaussian (SG) model. Absolute doses in water were validated using an Advanced Markus chamber at the depth of 2cm with Pristine Peak (BP) R90d ranging from 5–32 cm for 10×10 cm2 scanned fields. The field size factors were verified with square fields from 2 to 20 cm at 2cm and before BP depth. Results: The absolute dose outputs were found to be within ±3%. For field size factor, the agreement between calculated and measurement were within ±2% at 2cm and ±3% before BP, except for the field size below 2×2 cm2. Conclusion: The double Gaussian model was found to be sufficient for characterizing the Sumitomo dedicated proton line scanning nozzle. With our effective double Gaussian fitting method, we are able to save significant proton beam time with acceptable output accuracy.

60 APPLIED LIFE SCIENCES↗

What a difference a delay makes! CT urogram: a pictorial essay

Purpose: The aim of this pictorial essay is to demonstrate several cases where the diagnosis would have been difficult or impossible without the excretory phase image of CT urography. Methods: A brief discussion of CT urography technique and dose reduction is followed by several cases illustrating the utility of CT urography. Results: CT urography has become the primary imaging modality for evaluation of hematuria, as well as in the staging and surveillance of urinary tract malignancies. CT urography includes a non-contrast phase and contrast-enhanced nephrographic and excretory (delayed) phases. While the three phases add to the diagnostic ability of CT urography, it also adds potential patient radiation dose. Several techniques including automatic exposure control, iterative reconstruction algorithms, higher noise tolerance, and split-bolus have been successfully used to mitigate dose. The excretory phase is timed such that the excreted contrast opacifies the urinary collecting system and allows for greater detection of filling defects or other abnormalities. Sixteen cases illustrating the utility of excretory phase imaging are reviewed. Conclusions: Excretory phase imaging of CT urography can be an essential tool for detecting and appropriately characterizing urinary tract malignancies, renal papillary and medullary abnormalities, CT radiolucent stones, congenital abnormalities, certain chronic inflammatory conditions, and perinephric collections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating 225 Ac and 177 Lu Radioimmunoconjugates against Antibody–Drug Conjugates for Small-Cell Lung Cancer

Interest in the use of 225 Ac for targeted alpha therapies has increased dramatically over the past few years, resulting in a multitude of new isotope production and translational research efforts. However, 225 Ac radioimmunoconjugate (RIC) research is still in its infancy, with most prior experience in hematologic malignancies and only one reported preclinical solid tumor study using 225 Ac RICs. In an effort to compare 225 Ac RICs to other current antibody conjugates, a variety of RICs are tested against intractable small-cell lung cancer (SCLC). Here we directly compare, in vitro and in vivo , two promising candidates of each α or β - category, 225 Ac and 177 Lu, versus pyrrolobenzodiazepine (PBD) nonradioactive benchmarks. The monoclonal antibody constructs are targeted to either delta like 3 protein (DLL3), a recently discovered SCLC target, or CD46 as a positive control. An immunocompromised maximum tolerated dose assay is performed on NOD SCID mice, along with tumor efficacy proof-of-concept studies in vivo . We overview the conjugation techniques required to create serum-stable RICs and characterize and compare in vitro cell killing with RICs conjugated to nonspecific antibodies (huIgG1) with either native or site-specific thiol loci against tumor antigen DLL3-expressing and nonexpressing cell lines. Using patient-derived xenografts of SCLC onto NOD SCID mice, solid tumor growth was controlled throughout 3 weeks before growth appeared, in comparison to PBD conjugate controls. NOD SCID mice showed lengthened survival using 225 Ac compared to 177 Lu RICs, and PBD dimers showed full tumor suppression with nine out of ten mice. The exploration of RICs on a variety of antibody-antigen systems is necessary to direct efforts in cancer research toward promising candidates. However, the anti-DLL3-RIC system with 225 Ac and 177 Lu appears to be not as effective as the anti-DLL3-PBD counterpart in SCLC therapy with matched antibodies and portrays the challenges in both SCLC therapy as well as the specialized utility of RICs in cancer treatment.

60 APPLIED LIFE SCIENCES↗

Mapping the space radiation environment in LEO orbit by the SATRAM Timepix payload on board the Proba-V satellite

Detailed spatial- and time-correlated maps of the space radiation environment in Low Earth Orbit (LEO) are produced by the spacecraft payload SATRAM operating in open space on board the Proba-V satellite from the European Space Agency (ESA). Equipped with the hybrid semiconductor pixel detector Timepix, the compact radiation monitor payload provides the composition and spectral characterization of the mixed radiation field with quantum-counting and imaging dosimetry sensitivity, energetic charged particle tracking, directionality and energy loss response in wide dynamic range in terms of particle types, dose rates and particle fluxes. With a polar orbit (sun synchronous, 98° inclination) at the altitude of 820 km the payload samples the space radiation field at LEO covering basically the whole planet. First results of long-period data evaluation in the form of time-and spatially-correlated maps of total dose rate (all particles) are given.

79 ASTRONOMY AND ASTROPHYSICS↗

Recombination in liquid-filled ionization chambers beyond the Boag limit

Purpose: The high mass density and low mobilities of charge carriers can cause important recombination in liquid-filled ionization chambers (LICs). Saturation correction methods have been proposed for LICs. Correction methods for pulsed irradiation are based on Boag equation. However, Boag equation assumes that the charge ionized by one pulse is fully collected before the arrival of the next pulse. This condition does not hold in many clinical beams where the pulse repetition period may be shorter than the charge collection time, causing overlapping between charge carriers ionized by different pulses, and Boag equation is not applicable there. In this work, the authors present an experimental and numerical characterization of collection efficiencies in LICs beyond the Boag limit, with overlapping between charge carriers ionized by different pulses. Methods: The authors have studied recombination in a LIC array for different dose-per-pulse, pulse repetition frequency, and polarization voltage values. Measurements were performed in a Truebeam Linac using FF and FFF modalities. Dose-per-pulse and pulse repetition frequency have been obtained by monitoring the target current with an oscilloscope. Experimental collection efficiencies have been obtained by using a combination of the two-dose-rate method and ratios to the readout of a reference chamber (CC13, IBA). The authors have also used numerical simulation to complement the experimental data. Results: The authors have found that overlap significantly increases recombination in LICs, as expected. However, the functional dependence of collection efficiencies on the dose-per-pulse does not change (a linear dependence has been observed in the near-saturation region for different degrees of overlapping, the same dependence observed in the nonoverlapping scenario). On the other hand, the dependence of collection efficiencies on the polarization voltage changes in the overlapping scenario and does not follow that of Boag equation, the reason being that changing the polarization voltage also affects the charge collection time, thus changing the amount of overlapping. Conclusions: These results have important consequences for saturation correction methods for LICs. On one hand, the two-dose-rate method, which relies on the functional dependence of the collection efficiencies on dose-per-pulse, can also be used in the overlapping situation, provided that the two measurements needed to feed the method are performed at the same pulse repetition frequency (monitor unit rate). This result opens the door to computing collection efficiencies in LICs in many clinical setups where charge overlap in the LIC exists. On the other hand, correction methods based on the voltage-dependence of Boag equation like the three-voltage method or the modified two-voltage method will not work in the overlapping scenario due to the different functional dependence of collection efficiencies on the polarization voltage.

60 APPLIED LIFE SCIENCES↗

Arrays of Si vacancies in 4 H -SiC produced by focused Li ion beam implantation

Point defects in SiC are an attractive platform for quantum information and sensing applications because they provide relatively long spin coherence times, optical spin initialization, and spin-dependent fluorescence readout in a fabrication-friendly semiconductor. The ability to precisely place these defects at the optimal location in a host material with nano-scale accuracy is desirable for integration of these quantum systems with traditional electronic and photonic structures. Here, we demonstrate the precise spatial patterning of arrays of silicon vacancy (${V}_{Si}$) emitters in an epitaxial 4H -SiC (0001) layer through mask-less focused ion beam implantation of Li + . We characterize these arrays with high-resolution scanning confocal fluorescence microscopy on the Si-face, observing sharp emission lines primarily coming from the ${V1}^{{\prime}}$ zero-phonon line (ZPL). The implantation dose is varied over 3 orders of magnitude, leading to ${V}_{Si}$ densities from a few per implantation spot to thousands per spot, with a linear dependence between ZPL emission and implantation dose. Optically-detected magnetic resonance (ODMR) is also performed, confirming the presence of V2 ${V}_{Si}$. Our investigation reveals scalable and reproducible defect generation.

36 MATERIALS SCIENCE↗

WE-DE-201-10: Pitfalls When Using Ruby as An Inorganic Scintillator Detector for Ir-192 Brachytherapy Dosimetry

Purpose: To study the promising potential of inorganic scintillator detectors (ISDs) and investigate various unwanted luminescence properties which may compromise their accuracy. Methods: The ISDs were comprised of a ruby crystal coupled to a polymethyl methacrylate (PMMA) fiber-optic cable and a charged coupled device camera. A new type of ISD was manufactured and included a long-pass filter that was sandwiched between the crystal and the fiber-optic cable. The purpose of the filter was to suppress the Cerenkov and fluorescence background light induced in the PMMA (the stem signal) from striking the ruby crystal, generating unwanted ruby excitation. A variety of experiments were performed to characterize the ruby based ISDs. The relative contribution of the induced ruby signal and the stem signal were quantified while exposing the detector and a bare fiber-optic cable to a high dose rate (HDR) brachytherapy (BT) source, respectively. The unwanted ruby excitation was quantified while irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and a comparison to other commonly used organic scintillator detectors (BCF-12, BCF-60). Results: When the BT source dwelled 0.5 cm away from the fiber-optic cable, the unwanted ruby excitation amounted to >5% of the total signal if the source-distance from the scintillator was >7 cm. However, the unwanted excitation was suppressed to <1% if the ISD incorporated an optic filter. The stem signal was suppressed with a 20 nm band-pass filter and was <3% as long as the source-distance was <7 cm. The ruby based ISDs generated signal up to 20(40) times that of BCF-12(BCF-60). Conclusion: The study presents solutions to unwanted luminescence properties of ruby based ISDs for HDR BT. An optic filter should be sandwiched between the scintillator volume and the fiber-optic cable to prevent the stem signal to excite the ruby crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additive Manufacturing of Hierarchical Multi-Phase High-Entropy Alloys for Nuclear Component

In recent years, high entropy alloys (HEAs), composed of four or more metallic elements mixed in equal or near equal atomic percent, have attracted significant attention due to their excellent mechanical properties and good corrosion resistance. They show significant promise as candidates for high temperature fission and fusion structural applications. However, the conventional synthesis methods are unlikely to present an industrially suitable route for the production and use of HEAs. Recognizing rapidly evolving additive manufacturing (AM) techniques, the goal of this proposal is to optimize the AM process to fabricate HEAs with predesigned chemical compositions and phase morphologies for nuclear components. For this project, two HEAs FeCrNiMn and FeCrNiMnAl have been successfully synthesized. Correlated mechanical response has been systematically characterized under a variety of laser processing and ion irradiations. Both high entropy alloys are found to present comparable swelling and extraordinary irradiation tolerance (limited voids and stabilized phase structure under high irradiation dose). In addition, the microstructure and radiation-induced hardening can be tailored by laser processing under additive manufacturing. And we have assembled at LANL a unique database of HEAs containing a total of 674 compositions with Phase Stability information. Based on this, the machine learning and Artificial Intelligence capability now are established to predict the microstructure of casted HEAs by given chemical compositions. This unique integration will lead to an optimal AM recipe for fabricating radiation tolerant HEAs. The development of both modeling models and experimental capability will also benefit other programs at LANL.

36 MATERIALS SCIENCE↗

Assessment of the Reversion to Virulence and Protective Efficacy in Pigs Receiving the Live Attenuated Classical Swine Fever Recombinant Vaccine Candidate FlagT4G

Background/Objectives: Control of classical swine fever virus (CSFV) in endemic countries relies on vaccination using live attenuated vaccines (LAVs). Most of these LAVs do not allow for the differentiation of vaccinated animals from infected animals (DIVA) based on their serological response. FlagT4G vaccine is a novel candidate that confers robust protective immunity early after vaccination and shows DIVA capabilities. Methods: This report presents the characterization of FlagT4G virus in terms of the stability of its genomic and attenuated phenotypes assessed by a reversion to virulence protocol, as well as its protective efficacy by determining the minimal protective dose. Results: Results presented here demonstrate that after five consecutive passages in groups of 5-week-old susceptible domestic pigs, FlagT4G virus remains genetically stable, and its attenuated phenotype remains unaltered. In terms of efficacy, FlagT4G virus induced solid protection against the intranasal challenge with 105 tissue culture infectious dose (TCID50) of virulent field isolate Brescia virus, even with a vaccine dose as low as 102 TCID50. Conclusions: Results presented here indicate that the FlagT4G vaccine may be a useful tool for CSFV control.

Immunology↗