Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Progress of Tripwire: Multi-Modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Progress of Tripwire: Multi-modal Distributed Sensing for Repository Verification

This project is developing and demonstrating a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. This paper documents the results of the simulations and modeling efforts that have helped identify the optimal placement of the SFBs. Additionally, the paper includes the current progress on the multi-modal SFB-PCC system, including the fabrication of long-length (>3-m) fibers and their coupling to optical fibers.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Wound Field and Hybrid Synchronous Machines for EV Traction with Brushless Capacitive Rotor Field Excitation (Final Report)

This project focused on the development of wound field synchronous machines (WFSMs) and hybrid excitation synchronous machines (HESMs) with brushless capacitive power transfer for the field excitation. The target application for the machines developed is the main traction motor in electric vehicles. The magnetization in these types of machines is provided by a field winding on the rotor which is excited with DC current. The magnetization level in the machine can be varied by changing the magnitude of the field current. The variable magnetization or field is one of the key features of WFSMs. WFSMs are commonly used as generators however they have several attractive features for automotive traction applications. 1) No use of permanent magnet: Rare earth permanent magnets are primarily mined and processed in China. They have been subject to large price and supply variations and their export may be restricted during times of geopolitical tension. 2) Easy field weakening: Wound field synchronous machines have complete control of their field excitation. With proper design, this type of machine can electromagnetically have an infinite constant power speed range. 3) High power factor: With proper choice of the field excitation, WFSMs may be operated with high or even unity power factor. This potentially allows for the inverter connected to the stator winding to be downsized. In comparison induction machines and interior permanent magnet synchronous machines must supply reactive power to the stator increasing the kVA rating and cost of the inverter. 4) Reduced iron losses at high speed: By reducing the field excitation, the iron loss in the stator can be reduced. This is in comparison to interior permanent magnet synchronous machines which must use stator current to buck or reduce the flux produced by the permanent magnets. Generally, WFSMs have their highest efficiency at high speed. 5) Torque output at high temperatures: The magnetization provided by the field winding only depends on the field current and not on the field winding temperature. This is in contrast to permanent magnet machines where the permanent magnet flux decreases as the magnet temperature increases. Historically a number of approaches have been developed to provide DC current to the rotating field winding in WFSM’s including brushes and slip rings, low frequency brushless exciters, and high frequency rotary transformers and rectifiers. In this project, a different approach was used: brushless capacitive power transfer. Brushless capacitive power transfer uses two sets of rotating capacitors or electrodes in which an AC electric field is established by a high frequency inverter. A displacement current can flow through the airgap in the rotating capacitors which is rectified on the rotor using a diode bridge. The potential advantage of capacitive power transfer is that there is no need for heavy iron to guide magnetic flux. The electric flux lines terminate on the charges on the rotary capacitor surfaces. This should also limit the electric field outside the rotary capacitor airgaps. The main challenge with capacitive power transfer is that the capacitance and surface area of the rotating capacitors is small. Because capacitive power transfer systems are essentially a dual of a magnetic system, an Ampere per Hertz relationship is characteristic versus a Volts per Hertz relationship. A very high frequency power inverter must be used to provide sufficient excitation to the field winding. The concept of using capacitive power transfer to excite a high performance WFSM was initially developed in a previous U.S.A. Dept. of Energy project, DE-EE0006829. This project focused on increasing the power density of the WFSMs and reducing the cost and manufacturing complexity of the capacitive power transfer system. This project has demonstrated that WFSMs with brushless capacitive field power transfer can provide a high-power density and low-cost automotive powertrain technology.

33 ADVANCED PROPULSION SYSTEMS↗

Microprocessor controlled force actuator

The mechanical and electrical design of a prototype force actuator for vibration control of large space structures (LSS) is described. The force actuator is an electromagnetic system that produces a force by reacting against a proof-mass. The actuator has two colocated sensors, a digital microcontroller, and a power amplifier. The total weight of actuator is .998 kg. The actuator has a steady state force output of approximately 2.75 N from approximately 2 Hz to well beyond 1000 Hz.

Zimmerman, D. C.↗

Electron-impact ionization and electron attachment cross sections of radicals important in transient gaseous discharges

Electron-impact ionization and electron attachment cross sections of radicals and excited molecules were measured using an apparatus that consists of an electron beam, a molecular beam and a laser beam. The information obtained is needed for the pulse power applications in the areas of high power gaseous discharge switches, high energy lasers, particle beam experiments, and electromagnetic pulse systems. The basic data needed for the development of optically-controlled discharge switches were also investigated. Transient current pulses induced by laser irradiation of discharge media were observed and applied for the study of electron-molecule reaction kinetics in gaseous discharges.

Lee, Long C.↗

Low Power Magnetic Bearing Design for High Speed Rotating Machinery

Magnetic suspension technology has advanced to the point of being able to offer a number of advantages to a variety of applications in the rotating machinery and aerospace fields. One strong advantage is the decrease in power consumption. The design and construction of a set of permanent magnet biased, actively controlled magnetic bearing for a flexible rotor are presented. Both permanent magnets and electromagnets are used in a configuration which effectively provides the necessary fluxes in the appropriate air gaps, while simultaneously keeping the undesirable destabilizing forces to a minimum. The design includes two radial bearings and a thrust bearing. The theoretical development behind the design is briefly discussed. Experimental performance results for a set of operating prototype bearings is presented. The results include measurements of load capacity, bearing stiffness and damping, and the dynamic response of the rotor. With few exceptions, the experimental results matched very well with the predicted performance. The power consumption of these bearings was found to be significantly reduced from that for a comparable set of all electromagnetic bearings.

Allaire, P. E.↗

Solar control of the earth's emission of energetic O(+)

Energetic (0.1-16 keV/e) O(+) data obtained in the earth's plasma sheet (between 10 and 23 RE) by an ion mass spectrometer on the ISEE-1 spacecraft are compared statistically with published data on the concurrent solar wind and IMF. The most strongly variable parameter of the plasma sheet O(+) is its density, which is found to be well correlated with certain solar wind parameters, especially with the solar wind flow speed and the IMF component perpendicular to the flow vector. When those two solar wind parameters are combined to form an electric field (-v x B), both the number density and the energy density of the O(+) are found to vary in proportion to the square of that electric field, on average, suggesting that the emission of energetic O(+) ions from the earth may be powered by that same field. Based on this and on the previously published correlation with solar activity, it is argued that the emission of O(+) is controlled by a combination of HF (ionizing) and quasi-static (accelerating) solar electromagnetic fields.

Lennartsson, W.↗

Bone Analyzer

The danger of disuse osteoporosis under weightless condition in space led to extensive research into measurements of bone stiffness and mass by the Biomedical Research Division of Ames and Stanford University. Through its Technology Utilization Program, NASA funded an advanced SOBSA, a microprocessor-controlled bone probe system. SOBSA determines bone stiffness by measuring responses to an electromagnetic shaker. With this information, a physician can identify bone disease, measure deterioration and prescribe necessary therapy. The system is now undergoing further testing.

Source record↗

Flow Components in a NaK Test Loop Designed to Simulate Conditions in a Nuclear Surface Power Reactor

A test loop using NaK as the working fluid is presently in use to study material compatibility effects on various components that comprise a possible nuclear reactor design for use on the lunar surface. A DC electromagnetic (EM) pump has been designed and implemented as a means of actively controlling the NaK flow rate through the system and an EM flow sensor is employed to monitor the developed flow rate. These components allow for the matching of the flow rate conditions in test loops with those that would be found in a full-scale surface-power reactor. The design and operating characteristics of the EM pump and flow sensor are presented. In the EM pump, current is applied to a set of electrodes to produce a Lorentz body force in the fluid. A measurement of the induced voltage (back-EMF) in the flow sensor provides the means of monitoring flow rate. Both components are compact, employing high magnetic field strength neodymium magnets thermally coupled to a water-cooled housing. A vacuum gap limits the heat transferred from the high temperature NaK tube to the magnets and a magnetically-permeable material completes the magnetic circuit. The pump is designed to produce a pressure rise of 5 psi, and the flow sensor's predicted output is roughly 20 mV at the loop's nominal flow rate of 0.5 GPM.

Polzin, Kurt A.↗

GRC Supporting Technology for NASA's Advanced Stirling Radioisotope Generator (ASRG)

From 1999 to 2006, the NASA Glenn Research Center (GRC) supported a NASA project to develop a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions. Lockheed Martin was selected as the System Integration Contractor for the SRG110, under contract to the Department of Energy (DOE). The potential applications included deep space missions, and Mars rovers. The project was redirected in 2006 to make use of the Advanced Stirling Convertor (ASC) that was being developed by Sunpower, Inc. under contract to GRC, which would reduce the mass of the generator and increase the power output. This change would approximately double the specific power and result in the Advanced Stirling Radioisotope Generator (ASRG). The SRG110 supporting technology effort at GRC was replanned to support the integration of the Sunpower convertor and the ASRG. This paper describes the ASRG supporting technology effort at GRC and provides details of the contributions in some of the key areas. The GRC tasks include convertor extended-operation testing in air and in thermal vacuum environments, heater head life assessment, materials studies, permanent magnet characterization and aging tests, structural dynamics testing, electromagnetic interference and electromagnetic compatibility characterization, evaluation of organic materials, reliability studies, and analysis to support controller development.

Schreiber, Jeffrey G.↗

An assessment of controlled source EM for monitoring subsurface CO 2 injection at the wyoming carbonSAFE geologic carbon storage site

Here we evaluate if electromagnetic (EM) geophysical methods for monitoring geologic carbon storage (GCS) efforts at the Wyoming CarbonSAFE project adjacent to the Dry Fork Station power plant near Gillette, Wyoming. This first involved acquiring both electric and magnetic fields at eleven different locations ranging in distance from immediately adjacent to 4 km from the plant. Passive EM measurements were made to provide spectral EM noise measurements generated by electricity production at the plant and to determine if useful magnetotelluric (MT) data can be successfully collected in the region. The processed data indicate that useful MT data can be collected as long as the site is located more than 2km away from the power plant as well as active roads and rail lines. Controlled source EM data were collected using three different source configurations, two of which connected to steel casings used to complete the injection wells. Comparing the EM noise measurements to the CSEM data show measurable electric and magnetic field signals at all sites. Next a series of three-dimensional (3D) numerical models were built that simulate resistivity changes caused by the proposed CO2 injection at depths ranging from 2.4 to 3.0km. These models were used to simulate various EM measurement configurations. The modeling shows that casing-source CSEM monitoring can provide sensitivity to the injected CO 2 if source electrodes are connected to the bottom of one or both of the injection wells.

58 GEOSCIENCES↗

Controlling spins with surface magnon polaritons

Polaritons in metals, semimetals, semiconductors, and polar insulators can allow for extreme confinement of electromagnetic energy, providing many promising opportunities for enhancing typically weak light-matter interactions such as multipolar radiation, multiphoton spontaneous emission, Raman scattering, and material nonlinearities. These extremely confined polaritons are quasielectrostatic in nature, with most of their energy residing in the electric field. As a result, these “electric” polaritons are far from optimized for enhancing emission of a magnetic nature, such as spin relaxation, which is typically many orders of magnitude slower than corresponding electric decays. Here, we take concepts of “electric” polaritons into magnetic materials, and propose using surface magnon polaritons in negative magnetic permeability materials to strongly enhance spin relaxation in nearby emitters. Specifically, we provide quantitative examples with MnF 2 and FeF 2 , enhancing spin transitions in the THz spectral range. In this work we find that these magnetic polaritons in 100-nm thin films can be confined to lengths over 10 000 times smaller than the wavelength of a photon at the same frequency, allowing for a surprising 12 orders of magnitude enhancement in magnetic dipole transitions. This takes THz spin-flip transitions, which normally occur at timescales on the order of a year, and forces them to occur at sub-ms timescales. Our results suggest an interesting platform for polaritonics at THz frequencies, and more broadly, a way to use polaritons to control light-matter interactions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Supported X-ray horn for controlling e-beams

A magnetic apparatus and a method of operating the magnetic apparatus can include a scanning electromagnet that redirects a beam of charged particles, a vacuum chamber that prevents the atmosphere from interfering with the charged particles, and, a parallelizing permanent magnet array for parallelizing the beam of charged particles. The parallelizing permanent magnet array can be located proximate to a target comprising a Bremsstrahlung target or an object that is being irradiated. The magnetic field of the scanning electromagnet can be variable to produce all angles necessary to sweep the beam of charged particles across the target and the parallelizing permanent magnet array can be configured from a magnetic material that does not require an electric current.

Kroc, Thomas↗

Dipolar quantum logic for freely rotating trapped molecular ions

We consider the practical feasibility of using the direct, electric dipole-dipole interaction between cotrapped molecular ions for robust quantum logic without the need for static polarizing fields. Here, the use of oscillating dipole moments, as opposed to static electric dipoles, dynamically decouples the dipoles from laboratory fields, including the electric fields of the trap itself. Further, this implementation does not require the quantum control of motion, potentially removing a major roadblock to ion trap quantum computing scalability. Since the polarizing field is electromagnetic radiation, even pairs of states with splittings in the THz regime can be fully polarized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive optics and optical structures; Proceedings of the Meeting, European Congress on Optics, 3rd, The Hague, Netherlands, Mar. 12-14, 1990

The present conference on adaptive optics (AO) and optical structures addresses AO systems and controls, AO components, nonlinear optics applications to AO, astronomical applications of AO, large telescopes and optical alignment, as well as the wavefront control experiment for the use of AO in beam propagation. Specific references are made to applications of electromagnetic theory in optics, theoretical studies of system performance and design parameters, Hartmann-Shack wavefront sensing, the use of ray-based techniques in cophasing segmented mirrors, the use of a phase-conjugating mirror for real-time phase visualization, and the absolute instability of oppositely directed waves with respect to a high-reflectivity phase-conjugate mirror. Also addressed are automatic control systems, precision segmented reflectors, AO system creation, the VLT's 8.2-m primary mirrors, an optical 12-m telescope, alignment optimization via the Talbot effect, and a combination of interferometry and ray-tracing analysis.

Tyson, Robert K.↗

Optical position measurement for a large gap magnetic suspension system: Design and performance analysis

An optical measurement system (OMS) has been designed and tested for a large gap magnetic suspension system (LGMSS). The LGMSS will be used to study control laws for magnetic suspension systems for vibration isolation and pointing applications. The LGMSS features six degrees of freedom and consists of a planar array of electromagnets that levitate and position a cylindrical element containing a permanent magnet core. The OMS provides information on the location and orientation of the element to the LGMSS control system to stabilize suspension. The hardware design of this optical sensing system and the tracking algorithms are presented. The results of analyses and experiments are presented that define the accuracy limits of the optical sensing system and that quantify the errors in position estimation.

Welch, Sharon S.↗

Chemical Tuning Meets 2D Molecular Magnets

Two-dimensional (2D) magnets provoke a surge of interest in large anisotropy in reduced dimensions and are promising for next-generation information technology where dynamic magnetic tuning is essential. Until recently, the crucial metal-organic magnet Cr(pyz) 2 ∙xLiCl∙yTHF with considerable high coercivity and high-temperature magnetic order opens up a new platform to control magnetism in metal-organic materials at room temperature. Here we report an in-situ chemical tuning route to realize the controllable transformation of low-temperature magnetic order into room-temperature hard magnetism in Cr(pyz) 2 ∙xLiCl∙yTHF. The chemical tuning via electrochemical lithiation and solvation/desolvation exhibits continuously variable magnetic features from cryogenic magnetism to the room-temperature optimum performance of coercivity (H c ) of 8500 Oe and energy product of 0.6 MGOe. Such chemically flexible tunability of room-temperature magnetism is ascribed to the different degrees of lithiation and solvation that modify the stoichiometry and Cr-pyrazine coordination framework. Furthermore, the additively manufactured hybrid magnets show air stability and electromagnetic induction, providing potential applications. Our findings here suggest chemical tuning as a universal approach to control the anisotropy and magnetism of 2D hybrid magnets at room temperature, promising for data storage, magnetic refrigeration, and spintronics.

36 MATERIALS SCIENCE↗

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗