Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electricity system flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

PHOBOS Exploration using Two Small Solar Electric Propulsion Spacecraft

Primitive bodies are exciting targets for exploration as they provide clues to the early Solar system conditions and dynamical evolution. The two moons of Mars are particularly interesting because of their proximity to an astrobiological target. However, after four decades of Mars exploration, their origin and nature remain enigmatic. In addition, when considering the long-term objectives of the flexible path for the potential human exploration to Mars, Phobos and Deimos present exciting intermediate opportunities without the complication and expense of landing and ascending from the surface. As interest in these targets for the next frontier of human exploration grows, characterization missions designed specifically to examine surface properties, landing environments, and surface mapping prior to human exploration are becoming increasingly important. A precursor mission concept of this sort has been developed using two identical spacecraft designed from low cost, flight proven and certified off-the-shelf component and utilizing Solar Electric Propulsion (SEP) to orbit both targets as secondary payloads launched aboard any NASA or GTO launch. This precursor mission has the potential to address both precursor measurements that are strategic knowledge gaps and decadal science, including soil physical properties at the global and local (human) scale and the search for in situ resources.

Phobos↗

FSVPy: A python-based package for fluorescent streak velocimetry (FSV)

Predictive constitutive equations that connect easy-to-measure transport properties (e.g., viscosity and conductivity) with system performance variables (e.g., power consumption and efficiency) are needed to design advanced thermal and electrical systems. In this work, we explore the use of fluorescent particle-streak analysis to directly measure the local velocity field of a pressure-driven flow, introducing a new Python package (FSVPy) to perform the analysis. Fluorescent streak velocimetry combines high-speed imaging with highly fluorescent particles to produce images that contain fluorescent streaks, whose length and intensity can be related to the local flow velocity. By capturing images throughout the sample volume, the three-dimensional velocity field can be quantified and reconstructed. We demonstrate this technique by characterizing the channel flow profiles of several non-Newtonian fluids: micellar Cetylpyridinium Chloride solution, Carbopol 940, and Polyethylene Glycol. We then explore more complex flows, where significant acceleration is created due to microscale features encountered within the flow. We demonstrate the ability of FSVPy to process streaks of various shapes and use the variable intensity along the streak to extract position-specific velocity measurements from individual images. Thus, we demonstrate that FSVPy is a flexible tool that can be used to extract local velocimetry measurements from a wide variety of fluids and flow conditions.

Mechanics↗

Integrating agrivoltaics into smallholder farming systems to enhance food production and irrigation efficiency under climate stress

Smallholder agricultural growers and entrepreneurs (SAGE) have a crucial role in sustaining food security; their cultivation accounts for roughly 30% of global crop production and contributes substantially to the diversity and nutritional value of food systems. Despite their awareness of and flexibility to adapt to productivity challenges, SAGE communities remain highly vulnerable to heat and drought stress, which threatens both livelihoods and local food availability. While intensification and adaptive farm practices offer partial resilience, their capacity to buffer sudden climatic extremes remains limited. Agrivoltaics, the dual use of land for solar electricity generation and crop cultivation, has emerged as a promising strategy to enhance agricultural productivity and its resilience to climate extremes by altering microclimatic conditions. Although proven effective in hot and arid regions, the benefits of agrivoltaics for temperate climates and small-scale farms remain minimally explored. To address this gap, we evaluated the performance of a small-scale agrivoltaics system in a temperate climate for high-value crops, including leafy vegetables and garlic. We investigate whether the system can (i) protect crops during extreme heat events and (ii) enhance productivity and reduce irrigation requirements during hot and dry periods unsuitable for conventional production. Our findings provide evidence that agrivoltaics is a climate-resilient farming strategy under current and projected climate scenarios, capable of improving yields (by +43% to +127% for the leafy vegetables grown) and reducing water consumption, while creating complementary economic opportunities through decentralized energy generation systems. This work supports the integration of agrivoltaics into small-scale agricultural systems as an innovative pathway to strengthen food security, bolster farmer livelihoods, and enable multiple co-benefits from broader solar energy adoption.

14 SOLAR ENERGY↗

USAID Grid-Scale Energy Storage Technologies Primer

This work provides an overview and compares key operating characteristics of select energy storage technologies. This work explores how these storage technologies may be used to improve the flexibility and reliability of power systems given their technical characteristics. The report covers various electrochemical (lithium-ion, lead-acid, flow, sodium-sulfur), chemical (hydrogen), mechanical (pumped hydro storage, compressed air energy storage, flywheels, gravity) and electrical (supercapacitors) storage mediums.

25 ENERGY STORAGE↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

Journey into tomorrow - Developing nuclear propulsion for the Space Exploration Initiative

Nuclear propulsion, either nuclear thermal propulsion or nuclear electric propulsion, offers the potential of reduced trip times and/or reduced mass into low earth orbit, compared to chemical propulsion systems. In addition, the greater performance benefits of nuclear propulsion can provide the added margin for greater operational flexibility, including mission abort options and increased launch windows. During the 1950s and 1960s experimental and analytical studies showed the feasibility of nuclear propulsion. NASA, in cooperation with other agencies and organizations, is currently planning a technology development program for nuclear propulsion. The overall objective is to develop at least one NTP concept and one NEP concept for piloted and robotic (e.g., cargo) missions to Mars.

Harer, Kathleen F.↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Development of a Hardware-in-The-Loop Testbed for a Decentralized, Data-Driven Electric Vehicle Charging Control Algorithm

This study presents the design of an electric vehicle (EV)-grid integration (EVGI) hardware test-bed to implement smart EV charging algorithms. Here, the proposed test-bed also allows to create different grid events via flexible integration of other power hardware (e.g., controllable loads and battery energy storage systems) and test their impacts on EV charging. The design uses a real-time digital simulator to realize a complex distribution grid model with primary and secondary networks. A grid simulator physically realizes the selected nodes of the simulated grid to power an actual EV, forming a hardware-in-the-loop (HIL) test setup. The EV-grid integration is demonstrated based on the custom hardware and software implementation of the J1772 charging protocol using dSPACE MicroLabBox, operating as a custom EV Supply Equipment (EVSE). The HIL test-bed features a novel testing platform for accurate implementation and analysis of scalable charging algorithms. To this end, a data-driven, decentralized, model-free charging controller based on the Additive Increase and Multiplicative Decrease (AIMD) algorithm is presented and validated on an EV using the HIL test-bed. We tested the proposed algorithm under various case studies, and presented a comparison study with an existing droop-based, decentralized charging solution. The results showed that the EV successfully performed charging commands generated by the EVSE and regulated its charging power to effectively reduce the system loading caused by high EV penetration.

33 ADVANCED PROPULSION SYSTEMS↗

Adaptive/learning control of large space structures - System identification techniques

Techniques developed for the control of aircraft under changing operating conditions are used to develop a learning control system structure for a multi-configuration, flexible space vehicle. A configuration identification subsystem that is to be used with a learning algorithm and a memory and control process subsystem is developed. Adaptive gain adjustments can be achieved by this learning approach without prestoring of large blocks of parameter data and without dither signal inputs which will be suppressed during operations for which they are not compatible. The Space Shuttle Solar Electric Propulsion (SEP) experiment is used as a sample problem for the testing of adaptive/learning control system algorithms.

Thau, F. E.↗

Hydropower representation in water and energy system models: a review of divergences and call for reconciliation

Abstract Reservoir-based hydropower systems represent key interactions between water and energy systems and are being transformed under policy initiatives driven by increasing water and energy demand, the desire to reduce environmental impacts, and interacting effects of climate change. Such policies are often guided by complex system models, whereby divergence in system representations can potentially translate to incompatible planning outcomes, thereby undermining any planning that may rely on them. We review different approaches and assumptions in hydropower representation in water and energy systems. While the models and issues are relevant globally, the review focuses on applications in California given its extensive development of energy and water models for policy planning, but discusses the extent to which these observations apply to other regions. Structurally, both water-driven and energy-driven management models are similar. However, in energy models, hydropower is often represented as a single-priority output. Water management models typically allocate water for competing priorities, which are generally uninformed by dynamic electricity load demand, and often result in a lower priority for hydropower. In water models, constraints are increasingly resolved for non-energy components (e.g. inflow hydrology and non-energy water demand); few analogues exist for energy models. These limitations may result in inadequate representations of each respective sector, and vastly different planning outcomes for the same facilities between the two different sectors. These divergent modeling approaches manifest themselves in California where poorly reconciled outcomes may affect decisions in hydropower licensing, electricity grid flexibility and decarbonization, and planning for environmental water. Fully integrated water-energy models are computationally intensive and specific to certain regions, but better representation of each domain in respective efforts would help reconcile divergences in planning and management efforts related to hydropower across energy and water systems.

Rheinheimer, David E. (ORCID:0000000315259069)↗

Controlling distributed energy resources via deep reinforcement learning for load flexibility and energy efficiency

Behind-the-meter distributed energy resources (DERs), including building solar photovoltaic (PV) technology and electric battery storage, are increasingly being considered as solutions to support carbon reduction goals and increase grid reliability and resiliency. However, dynamic control of these resources in concert with traditional building loads, to effect efficiency and demand flexibility, is not yet commonplace in commercial control products. Traditional rule-based control algorithms do not offer integrated closed-loop control to optimize across systems, and most often, PV and battery systems are operated for energy arbitrage and demand charge management, and not for the provision of grid services. More advanced control approaches, such as MPC control have not been widely adopted in industry because they require significant expertise to develop and deploy. Recent advances in deep reinforcement learning (DRL) offer a promising option to optimize the operation of DER systems and building loads with reduced setup effort. However, there are limited studies that evaluate the efficacy of these methods to control multiple building subsystems simultaneously. Additionally, most of the research has been conducted in simulated environments as opposed to real buildings. This paper proposes a DRL approach that uses a deep deterministic policy gradient algorithm for integrated control of HVAC and electric battery storage systems in the presence of on-site PV generation. The DRL algorithm, trained on synthetic data, was deployed in a physical test building and evaluated against a baseline that uses the current best-in-class rule-based control strategies. Performance in delivering energy efficiency, load shift, and load shed was tested using price-based signals. The results showed that the DRL-based controller can produce cost savings of up to 39.6% as compared to the baseline controller, while maintaining similar thermal comfort in the building. The project team has also integrated the simulation components developed during this work as an OpenAIGym environment and made it publicly available so that prospective DRL researchers can leverage this environment to evaluate alternate DRL algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated operation of pumped-storage hydropower with power and water distribution systems

Small pumped-storage hydropower (PSH) units have gained popularity as distributed energy storage options that can provide flexibility to the operation of power distribution systems. Optimal operation of small PSH units is not only dependent on the energy storage provided to power distribution system, but also on the inflow and outflow of water from and to the water distribution system. Here, in this context, this paper develops an optimization model for coordinated operation of PSH units with power and water distribution systems. The proposed model optimizes the operation of water tanks, variable-speed pumps and PSH in pumping and generating modes to minimize the operation cost of power distribution system, while respecting the power flow constraints of power distribution and hydraulic constraints of water distribution system. Appropriate electricity tariffs are implemented to avoid additional expenses in water distribution system that can be enforced by its coordinated operation in favor of power distribution system. The proposed model is implemented on a 33-bus and a 123-bus test power distribution system connected to a 16-node test water distribution system. Results demonstrate the effectiveness of proposed model in tapping PSH flexibility to reduce the operation cost of power and water distribution systems, while meeting the power and water demands.

13 HYDRO ENERGY↗

System and Component Development of Particle-Based Pumped Thermal Energy Storage

Reliable power supply from variable renewable resources requires energy storage at various scales to overcome resource intermittency. Long-duration energy storage (LDES, 10-100 hours) can improve dispatchability and grid reliability with increasing levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus has the potential to meet the LDES need and provide charging and discharging durations beyond the economic capacity of conventional batteries. TES technology has evolved from concentrating solar thermal power (CSP) generation and is recognized as an economic large-scale energy storage method. A standalone electric-thermal energy storage system supporting renewable integration of wind and solar power without CSP solar field can firm renewable generation and boost overall grid resilience and security.

concentrating solar thermal power↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

A Multiport DC Transformer to Enable Flexible Scalable DC as a Service

The rapid adoption of new DC loads and sources, including photovoltaic arrays, DC fast charging of electric vehicle, battery energy storage and data centers, requires a large amount of DC power conversion. A majority of new deployments also necessitate the integration of multiple DC loads and sources at one site. The traditional approach to serve these new applications relies on multiple standard power converters, each dedicated to a source or load, and results in highly customized systems, with challenging control coordination, complex protection strategies, and poor scalability. Instead, this paper proposes the concept of a multiport DC transformer (MDCT) as a modular building block for realizing a flexible, scalable DC as a Service system and address this rapidly growing need. The MDCT uses the S4T to achieve very tight control of cycle-by-cycle energy exchange between multiple ports, with high efficiency. A single multiport converter replaces 4-6 distinct converters, integrates all energy flows and manages protection. As a result, a new layered control architecture is introduced to ensure stability and scalability of the MDCT, with multiple S4T power converter building blocks connected in parallel to realize a fully modular system and reach the target power levels.

30 DIRECT ENERGY CONVERSION↗

The Transactive Energy Network Template Metamodel

While transactive energy, which is defined as an allocation of electricity based on dynamically discovered values or prices, has been extensively studied, its uptake and use has been slow. This report describes a tool, the transactive network template, which should hasten the creation and uptake of transactive energy networks. Some basic principles of transactive energy are familiar from existing wholesale electricity markets. Locational prices are calculated today for zones within bulk electric transmission systems. Locational prices differ while accounting for the locational costs of electricity generation and the losses and constraints incurred when electricity is transmitted from generators and distributed to consumers. A transactive energy network might include these transmission zones. However, current research strives to apply transactive energy also in electricity distribution circuits, buildings, and even for individual generating and consuming devices. At the same time, researchers explore how to apply transactive energy in real time during increasingly shorter time intervals. Automated computational agents become necessary as transactive energy becomes applied to smaller circuit zones and at faster dynamic timescales. A transactive energy network is an example of a multi-agent system. Each zone in the network is represented by its transactive agent, which makes decisions for and acts on behalf of a business entity that is responsible for and manages one of the circuit regions. A transactive energy network is also an example of a decentralized, distributed control system. Control decisions and responsibilities are distributed among the network’s transactive agents. The transactive agents are independent; that is, there typically is no centralized authority or oversight function. Instead, transactive agents exchange transactive signals and thereby negotiate the prices and quantities of electricity that they will exchange. Initially, the circuit regions and responsibilities of transactive agents appear to be very dissimilar. Each circuit region may comprise transmission, distribution, or building-level circuits. Each has a unique position and electrical connectivity within the transactive energy network. Each possesses unique assets that either generate or consume electricity, and these (e.g., renewable energy generator, diesel generator, aggregate utility load, building load, space conditioning, refrigerator, etc.) may further differ in their price flexibility and in their strategies for responding to dynamic electricity prices. Given such diversity, an implementer’s first inclination might be to start from scratch to define all these devices and to engineer their seemingly unique interactions. Given that each implementer’s perspective may be narrow within a transactive energy network, it is unlikely that uniquely engineered systems would interact well. This is where the transactive network template is applicable. The transactive network template is a metamodel that has been developed to guide implementers as they configure their own transactive agent within a network of such agents. The object-oriented design of the transactive network template provides basic code object types that may be used and extended by implementers to represent each of the assets in their circuit region. These objects further facilitate the transactive agent’s necessary computations, which are divided among responsibilities to schedule power usage, balance electric supply and demand, and coordinate the exchange of electricity with the other transactive agents. This report addresses the conceptual transactive network template design. Implementers are directed to more formal design documents and reference implementations. A Python™-based1 reference implementation of the transactive network template has been coded, and three implementations have been configured to represent a national laboratory and two university campuses. Version 2 of the transactive node template generalizes the market class and its methods to facilitate multiple, and more diverse market coordination mechanisms than were facilitated by and demonstrated using Version 1. Version 3 includes new Appendix B, which addresses the designs of methods that would make dynamic prices track approved electricity rates. In the future, the author wishes to make the transactive network template more generally applicable to networks that require more accurate power flow. Development of the transactive network template is jointly funded by the U.S. Department of Energy (DOE) Energy Efficiency and Renewable Energy and the DOE Office of Electricity. In late 2015, one of the first projects to be funded by the DOE Grid Laboratory Modernization Laboratory Consortium was the Clean Energy and Transactive Campus project, led by Pacific Northwest National Laboratory. DOE funds were matched by an investment by the Washington Department of Commerce through its Clean Energy Fund. The transactive network template was developed to guide the implementation of transactive energy networks within this project’s scope.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity Markets for Transactive Energy Systems

Capacity markets provide important incentives for resource adequacy in electricity markets and may become more important for providing sufficient revenue and generation capacity with changes to energy market prices driven by increasing levels of zero marginal cost resources. However, current capacity market designs also have important shortfalls that may limit the benefits they can provide to the future grid. Current capacity markets are primarily designed for participation from conventional thermal generators, but markets are evolving with increasing levels of variable renewable energy resources. However, further reforms may be necessary to enable more participation from DERs and demand-side resources. To understand the benefits and shortfalls of current capacity market design, we review the historical reasons electricity markets have needed capacity markets or capacity payments for resource adequacy, and how current capacity market designs may create challenges for incorporating increasing levels of DERs and demand-side resources. We then consider how transactive systems, which allow the coordination of bids and offers for DERs and demand-side resources through a market interaction approach, administered by a Distribution System Operator (DSO), can address traditional resource adequacy problems due to inelastic consumer demand. We also consider the need for a DSO-level capacity market in helping to meet resource adequacy, reliability, and other electricity market objectives. We find that because the missing money in electricity markets is largely driven by incentives to meet resource adequacy goals, and the bulk grid would always supply power to the DSO, that resource adequacy is unlikely to be a determining factor in the need for a DSO-level capacity market. Many current reliability problems could also be addressed by the incorporation of more flexible demand enabled with transactive energy systems. However, other DSO objectives, including resilience, reactive power, voltage control, environmental policies, and energy equity could lead to specific challenges that could be aided by a DSO-level capacity market. We consider the possibility of a DSO-level capacity market in addressing these challenges as well as its potential role in coordinating with the Independent System Operator (ISO) who operates the wholesale market. We conclude with suggestions for future research, including the need to develop analytical models of DSO-level capacity market designs to address these potential objectives and examine their implications for DSOs and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗