Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Saving”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of AddUp Precision L-PBF Technology for Tooling and Other Industrial Applications

ORNL (Contractor) and AddUp Inc. (Participant) collaborated to enable the adoption of laser powder bed fusion for tooling applications, critical for reshoring the manufacturing sector in the U.S. Most of the work on laser powder bed fusion has focused on high value materials such as Ti-6Al-4V and Inconel 718 for niche applications in aerospace, biomedical and energy sectors. In this collaboration, ORNL and AddUp worked laser powder bed fusion of maraging steels for tooling applications while leveraging the unique ability of the AddUp laser powder bed fusion system to deposit fine powders. We demonstrated that the AddUp technology is capable of depositing complex artifacts and features such as overhangs within desired tolerances. We also showed that direct aging of the deposited parts result in simultaneously higher strength and elongation compared to the conventional two step heat treatments, which could result in significant energy savings. Finally, we developed thermos-kinetic models to enable design of heat treatments for optimal material properties compared to the energy intensive empirical methods currently used. The report summarizes the detailed findings of this collaboration.

36 MATERIALS SCIENCE↗

Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China

Increasing envelope facet albedos considerably reduces solar heat gain, thus yielding building cooling energy savings. Few studies have explored the potential benefits of utilizing cool coatings on building envelopes (“cool-coated buildings”) based on life-cycle cost analysis. A holistic approach integrating the field testing, building energy simulation, and a 20-year life-cycle-based optimization was developed to explore cool-coated building performance and the maximum net savings of optimal building envelope retrofit and design. Experimental results showed that applying cool coatings to a west wall of an office building in Chongqing, China reduced its exterior surface temperature by up to 9.3 °C in summer. Additionally, simulation results showed that in Chongqing, making the roof and walls cool could reduce annual HVAC electricity use by up to 11.9% in old buildings (with poorly insulated envelopes) and up to 5.9% in new buildings. Retrofitting old buildings with a cool roof provided the net savings per modified area with present values up to 42.8 CNY/m2; retrofitting a new building with a cool roof or cool walls was not cost-effective. Optimizing both envelope insulation and envelope albedo can achieve 5.6 times the net savings of optimizing the insulation only, and 1.6 times that of optimizing albedo only.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional suitability of heating tower heat pumps based on technical and economic performance maps

The heating tower heat pump (HTHP) technology is evolving rapidly due to its high performance in summer and frost-free characteristic in winter. However, lacking comprehensive comparisons between the HTHP and conventional methods, such as air-source heat pump (ASHP), and chiller and boiler, greatly limits its applications. To address this problem, this paper carries out technological and economic performance analyses of the three systems in 353 locations over China by the processes of building load calculation, system sizing, annual simulation, performance comparison, and demonstration. Energy saving principle and potential of the HTHP are presented and explained. Based on that, economic performance comparison is conducted by considering the energy conversion efficiency and prices. The results show that the HTHP has advantage over the ASHP in most locations in China. The improvement in annual coefficient of performance (COP) is about 10% to 20%. For the locations in southwest China like Chongqing, the improvement is also less than 10% due to the large regeneration penalization in winter and small difference between dry-bulb and wet-bulb temperature in summer. The annual COP of the HTHP is 10% to 23% higher than that of the chiller and boiler in hot summer and cold winter zone, and cold zone. However, the HTHP shows no advantage over the chiller and boiler in severe cold zone because of the low efficiency of heat pump in winter, neither in hot summer and warm winter zone due to the small heating load. Based on the results, technical and economic performance maps are developed to guide the application of the HTHP in different climate regions.

heating tower heat pump, air-source heat pump, chi↗

Syracuse University Industrial Assessment Center (Final Report)

Syracuse University Industrial Assessment Center (SU-IAC) project is focused on the two primary objectives: (i) educate undergraduate and graduate students in engineering and associated disciplines on the concepts of energy sustainability and to provide hands-on training by performing energy assessment at industrial facilities to become future energy efficiency experts, and (ii) offer energy assessments to small and mid-sized manufacturing companies in SU-IAC 2 the greater New York State region, perform analytical engineering work in support of assessment recommendations, and to report the results of those analyses to the client companies, to DOE, and to Field office personnel Through this project period, SU-IAC successfully trained 77 engineering students who were undergraduate or graduate students at Syracuse University College of Engineering, or at SU- IAC’s satellite center at Clarkson University. Each of these students received comprehensive ‘in-class’ technical training, safety training, and hands-on field training. The students performed various tasks related to energy assessment at the manufacturing facilities, including billing analysis, energy use reduction recommendations, and report preparation. Through this project period, a total of 34 students have completed all requirements of the SU-IAC program and have received the US DoE Certificate on Energy Efficiency, with the remaining students continuing at various stages of field work or training. During this project period, due to Covid-related measures in New York State, Syracuse University campus and most of the manufacturing facilities were completely closed or were under severe restrictions for access, for an extended period from March 2020 through April 2021. The closures affected our project execution, with the project Sponsor offering structured relief to carry-out a modified project during the affected budget periods. During this project period, SU-IAC student teams, led by its Director, completed a total of 77 energy assessments at small- and medium-scale manufacturing facilities located in New York State. For these facilities, SU-IAC prepared and presented details for 569 assessment recommendations (ARs). The facilities implemented a total of 258 of these ARs, realizing annual average energy savings in the range of $\$ $3,300 to $\$ $55,000 per facility. Cumulatively, these facilities have reduced their “first year after implementation” energy use by a total of 4.37 million kwh, and fuel use by a total of 27.7 billion BTU. SU-IAC project has successfully met the two primary objectives (and the associated sub objectives) and helped the manufacturing facilities in New York State achieve quantitative energy use reductions as a result of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mode shift strategies in intercity transportation and their effect on energy consumption

Policies are examined which, if implemented, could lead to significant energy savings in intercity travel in the northeast corridor arena, without restricting the traveler's freedom of mode choice. The effects on arena energy consumption of introducing new, more energy-efficient aircraft are investigated; and several strategies unrelated to the implementation of new aircraft are introduced to yield reductions in overall intercity energy use. In both parts of this analysis, resulting changes in patronage (modal share) and energy use are demonstrated, leading to new insights into the effectiveness of different potential policies for achieving energy conservation. Some observations on induced demand trends that could be associated with certain strategies and the resultant potential effect on energy conservation are provided.

Sokolsky, S.↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Why Tunable? A Look at Schools Using Tunable Lighting

Between 2016-2019, Pacific Northwest National Laboratory (PNNL), documented two early pilot installations of tunable lighting in schools, supported by U.S. Department of Energy (DOE) Solid-State Lighting (SSL) program. These pilot installations were opportunities for the schools to become more familiar with the technology, save energy, and support teachers and students. Tunable lighting continues to be of interest, particularly in classrooms for students with disabilities. This case study looks at tunable lighting systems installed in classrooms at eight school districts across the U.S. since 2015, the earliest known installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building ControlScore: Research Laboratory Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore tool which captures operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refining Control, Charging, and Battery Chemistry for CO 2 e Savings in Heavy-Duty Off-Road Plug-In Series Hybrid

With current and future regulations continuing to drive reductions in carbon dioxide equivalent (CO 2 e) emissions in the on-road industry, the off-road industry is also likely to be regulated for fuel and CO 2 e savings. This work focuses on converting a heavy-duty off-road material handler from a conventional diesel powertrain to a plug-in series hybrid, achieving a 49% fuel reduction and 29% CO 2 e reduction via simulation. Control strategies were refined for energy savings, including a regenerative braking strategy to increase regenerative braking and a load-following hydraulic strategy to decrease electrical energy consumption. The load-following hydraulic control shuts off the hydraulic electric machine when it is not needed—an approach not previously seen in a load-sensing, pressure-compensated system. Furthermore, these strategies achieved a 24.1% fuel savings, resulting in total savings of 61% in fuel and 41% in CO 2 e in the plug-in series compared to the conventional machine. Beyond control strategies, this study evaluated battery chemistry and charging strategy refinements for total cost of ownership (TCO) and lifetime CO 2 e. LFP batteries emerged as the most cost-effective and least emitting due to their longer lifespan, which reduced replacement frequency. Charging comparisons showed that Level 2 charging (L2C) typically resulted in lower TCO but higher lifetime CO 2 e than DC fast charging (DCFC). DCFC costs were heavily influenced by local demand charges, and DCFC emissions were heavily influenced by local grid emissions.

33 ADVANCED PROPULSION SYSTEMS↗

diffReplication - An Energy-Aware Fault Tolerance Model for Silent Error Detection and Mitigation in Heterogeneous Extreme-scale Computing Environment

At extreme scale, the frequency of silent errors – a class of errors that remain undetected by low-level error detection mechanisms – increases significantly with the computational complexity of the application and the scale of the computing infrastructure. As hardware and software advances are made to usher in the next scientific era of computing, developing new approaches to mitigate the impact of silent errors remains a challenging problem. In this work, we propose an energy-aware fault-tolerance model, referred to diffReplication to overcome silent errors. In the proposed model, the main process is associated with one replica that executes at the same rate as the main process, and one diffReplica that is executed at a fraction of the main process' execution rate. If the main and its replica reach consensus at the end of a computation phase, the state of the diffReplica is updated and computation is resumed. If the synchronization attempt results in a disagreement, however, the diffReplica increases its execution speed to complete the computation and quickly reach the synchronization barrier. Assuming a single error over any given synchronization interval, a majority voting is used to reach consensus and tolerate silent errors. To further enhance its performance, diffReplication is augmented with speculative execution, whereby the main or its fast replica is selected to continue execution without waiting for the diffReplica. The selection process is based on the previous behaviour of the main and its replica. A performance analysis study is carried out to assess the performance of diffReplication, in terms of the energy saving and time-to-completion reduction achieved by the diffReplication scheme. The experiment shows that speculative execution reduces the time to completion with additional energy, and dynamic decision-making balances the energy consumption and time to completion.

97 MATHEMATICS AND COMPUTING↗

Fuel cell environmental life cycle assessment : a progress report

Energy generation using fuel cells offers the possibility of high conversion efficiency and reduced pollution. Thus, in the futue, conventional methods of energy generation using coalfired power plants, natural gas turbines and internal combustion engines can potentially be replaced by fuel cells. The United States, Japan and several countries in Europe are currently developing fuel cells for transportation, distributed energy generation and portable electronics applications. On a system basis, the efficiency of chemical to electrical energy conversion in fuel cells can be as high as 45%. Also, because of the lower operating temperatures compared to turbines and internal combustion engines, emissions such as carbon monoxide and nitrogen oxides are extremely small. An assessment of the environmental impact of fuel cells over the entire lifecycle is needed to determine the specific benefits in various application scenarios. Such a comparative pollutants assessment must include a "cradle to grave" approach encompassing fuel production, fuel transportation, materials/manufacturing processes, waste management, and recycling. A comparative pollutant model would be a useful tool for industry and government in estimating energy savings and environmental credits, and providing a holistic understanding on regulatory needs. Another important benefit would be the ability to make appropriate comparisons with competitive energy generation technologies such as hybrids, turbines, and internal combustion engines, and to set up realistic targets. Also, exercising the model will assist in the initial screening for potential hot spots and showstoppers and focus on the right component technologies design for manufacturing, designs for input substitution and waste minimization, and prevent any unforeseen burdens.

Narayanan, S. R.↗

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Industrial Energy Assessment Training Effectiveness Evaluation: An Eye-Tracking Study

It is essential to understand the effectiveness of any training program so it can be improved accordingly. Various studies have applied standard metrics for the evaluation of visual behavior to recognize the areas of interest that attract individuals’ attention as there is a high correlation between attentional behavior and where one is focusing on. However, through reviewing the literature, we believe that studies that applied eye-tracking technologies for training purposes are still limited, especially in the industrial energy assessment training field. In this paper, the effectiveness of industrial energy assessment training was quantitatively evaluated by measuring the attentional allocation of trainees using eye-tracking technology. Moreover, this study identifies the areas that require more focus based on evaluating the performance of subjects after receiving the training. Additionally, this research was conducted in a controlled environment to remove the distractions that may be caused by environmental factors to only concentrate on variables that influence the learning behavior of subjects. The experiment results showed that after receiving the training, the subjects’ performance in energy assessment was significantly improved in two areas: production, and recycling and waste management, and the designed training program enhanced the knowledge of participants in identifying energy-saving opportunities to the knowledge level of experienced participants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

22 GeV CEBAF with Novel Fixed Field Alternating Gradient Design

Extending the energy reach of CEBAF up to 22 GeV within the existing tunnel is being explored. Proposed energy upgrade can be achieved by increasing the number of recirculations, while using the existing CEBAF SRF cavity system. Presented scheme is based on an exciting new approach to acceleratie electrons efficiently with multiple passes in a single FFA beam line. Encouraged by recent success of the CBETA Test Accelerator, a proposal was formulated raise CEBAF energy by replacing the highest-energy arcs with Fixed Field Alternating Gradient (FFA) arcs. The new pair of arcs configured with FFA lattice would support simultaneous transport of additional 6 passes with energies spanning a factor of two, using the non-scaling FFA principle implemented with Halbach-derived permanent magnets - a novel magnet technology that significantly saves energy and lowers operating costs. One of the challenges of the multi-pass (11) linac optics is to provide uniform focusing in a vast range of energies, using fixed field lattice. Here, we propose a triplet lattice scaled up with increasing momentum along the linac. This would provide a stable periodic solution covering energy ratio of 1:33. The current CEBAF configured with a 123 MeV injector, makes optical matching in the first linac virtually impossible due to extremely high energy span ratio (1:175). Therefore, we envision replacement of the current injector with a 650 MeV 3-pass recirculating injector based on the existing LERF facility. Finally, the 22 GeV CEBAF would promise to deliver in 10-passes a beam with normalized emittance of 80 mm·mrad and with a relative energy spread of 1.5 × 10-3. Further recirculation beyond 22 GeV is limited by large, 974 MeV per electron, energy loss due to synchrotron radiation.

Bogacz, Slawomir↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design Progress for the 22 GeV CEBAF Energy Upgrade

Extending the energy reach of CEBAF up to 22 GeV within the existing tunnel is being explored. Proposed energy upgrade can be achieved by increasing the number of recirculations, while using the existing CEBAF SRF cavity system. A proposal was formulated to raise CEBAF energy by replacing the highest-energy arcs with FFA arcs. The new pair of arcs configured with FFA (Fixed Field Alternating Gradient) lattice would support simultaneous transport of additional 6 passes with energies spanning a factor of two, using the non-scaling FFA principle implemented with Halbach-derived permanent magnets - a novel magnet technology that significantly saves energy and lowers operating costs. The design involves new optics for the linacs and remaining electromagnetic arcs, as well as new electromagnetic switchyard. These feed into the permanent magnet FFA arcs. We also report on ongoing beam dynamics studies and mitigating measures to alleviate energy loss and emittance dilution due to synchrotron radiation.

Bogacz, Alex [Thomas Jefferson National Accelerato↗