Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

ISOTOPIC MASS FRACTIONATION OF SOLAR WIND: EVIDENCE FROM FAST AND SLOW SOLAR WIND COLLECTED BY THE GENESIS MISSION

NASA's Genesis space mission returned samples of solar wind collected over {approx}2.3 years. We present elemental and isotopic compositions of He, Ne, and Ar analyzed in diamond-like carbon targets from the slow and fast solar wind collectors to investigate isotopic fractionation processes during solar wind formation. The solar wind provides information on the isotopic composition for most volatile elements for the solar atmosphere, the bulk Sun and hence, on the solar nebula from which it formed 4.6 Ga ago. Our data reveal a heavy isotope depletion in the slow solar wind compared to the fast wind composition by 63.1 {+-} 2.1 per mille for He, 4.2 {+-} 0.5 per mille amu{sup -1} for Ne and 2.6 {+-} 0.5 per mille amu{sup -1} for Ar. The three Ne isotopes suggest that isotopic fractionation processes between fast and slow solar wind are mass dependent. The He/H ratios of the collected slow and fast solar wind samples are 0.0344 and 0.0406, respectively. The inefficient Coulomb drag model reproduces the measured isotopic fractionation between fast and slow wind. Therefore, we apply this model to infer the photospheric isotopic composition of He, Ne, and Ar from our solar wind data. We also compare the isotopic composition of oxygen and nitrogen measured in the solar wind with values of early solar system condensates, probably representing solar nebula composition. We interpret the differences between these samples as being due to isotopic fractionation during solar wind formation. For both elements, the magnitude and sign of the observed differences are in good agreement with the values predicted by the inefficient Coulomb drag model.

79 ASTRONOMY AND ASTROPHYSICS↗

GLOBAL CORONAL SEISMOLOGY IN THE EXTENDED SOLAR CORONA THROUGH FAST MAGNETOSONIC WAVES OBSERVED BY STEREO SECCHI COR1

We present global coronal seismology for the first time, which allows us to determine inhomogeneous magnetic field strength in the extended corona. From the measurements of the propagation speed of a fast magnetosonic wave associated with a coronal mass ejection (CME) and the coronal background density distribution derived from the polarized radiances observed by the STEREO SECCHI COR1, we determined the magnetic field strengths along the trajectories of the wave at different heliocentric distances. We found that the results have an uncertainty less than 40%, and are consistent with values determined with a potential field model and reported in previous works. The characteristics of the coronal medium we found are that (1) the density, magnetic field strength, and plasma β are lower in the coronal hole region than in streamers; (2) the magnetic field strength decreases slowly with height but the electron density decreases rapidly so that the local fast magnetosonic speed increases while plasma β falls off with height; and (3) the variations of the local fast magnetosonic speed and plasma β are dominated by variations in the electron density rather than the magnetic field strength. These results imply that Moreton and EIT waves are downward-reflected fast magnetosonic waves from the upper solar corona, rather than freely propagating fast magnetosonic waves in a certain atmospheric layer. In addition, the azimuthal components of CMEs and the driven waves may play an important role in various manifestations of shocks, such as type II radio bursts and solar energetic particle events.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTIPLE FAST MOLECULAR OUTFLOWS IN THE PRE-PLANETARY NEBULA CRL 618

CRL 618 is a well-studied pre-planetary nebula. It has multiple highly collimated optical lobes, fast molecular outflows along the optical lobes, and an extended molecular envelope that consists of a dense torus in the equator and a tenuous round halo. Here we present our observations of this source in CO J = 3-2 and HCN J = 4-3 obtained with the Submillimeter Array at up to ∼0.''3 resolutions. We spatially resolve the fast molecular outflow region previously detected in CO near the central star and find it to be composed of multiple outflows that have similar dynamical ages and are oriented along the different optical lobes. We also detect fast molecular outflows further away from the central star near the tips of the extended optical lobes and a pair of equatorial outflows inside the dense torus. We find that two episodes of bullet ejections in different directions are needed, one producing the fast molecular outflows near the central star and one producing the fast molecular outflows near the tips of the extended optical lobes. One possibility to launch these bullets is a magneto-rotational explosion of the stellar envelope.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of sawtooth crashes on fast ion distribution in NSTX-U

During the 2016 experimental campaign of NSTX-U (Menard et al 2012 Nucl. Fusion 52 083015), long L-mode and reproducible sawtoothing plasmas have been achieved that were previously not accessible before the upgrade. This provides a good opportunity to study the effect of sawtooth crashes on fast ion confinement and redistribution in spherical tokamaks. The solid-state neutral particle analyzer (SSNPA) and fast ion D-alpha (FIDA) diagnostics on NSTX-U each have a tangentially-viewing instrument and a radially- or vertically-viewing instrument, which are mainly sensitive to passing and trapped fast ions, respectively. It has been observed on both diagnostics that passing particles are strongly expelled from the plasma core to the edge during sawtooth crashes, while trapped fast ions are weakly affected. The tangentially-viewing SSNPA observes large signal spikes at the sawtooth crashes because fast ions move to the edge and charge exchange with edge neutrals. The radially-viewing SSNPA data suggest that there is a small drop of trapped particles in the core. The tangentially-viewing FIDA (t-FIDA) system observes a depletion as large as 25% in the region inside the inversion radius, while an increase at the outer region. There is almost no change in the signals of the vertically-viewing FIDA system. The neutron emission can drop as much as 15% at the sawtooth crashes, accompanied by an increase of edge D α light. Simulations with the Kadomstev and Porcelli sawtooth models have also been performed and compared with the measurements. The full reconnection Kadomtsev model overestimates the neutron rate drop at each sawtooth crash. When tuning the sawtooth input parameters, the partial reconnection Porcelli sawtooth model can qualitatively reproduce the neutron rate drop and t-FIDA signal drop in the core, but it fails to predict the t-FIDA signal increase at the edge.

43 PARTICLE ACCELERATORS↗

Investigation of fast particle redistribution induced by sawtooth instability in NSTX-U

The effects of sawtooth on fast ion transport have been examined in reproducible, 2s long sawtoothing L-mode discharges during the 2016 experimental campaign on National Spherical Torus Experiment Upgrade (NSTX-U) [J.E. Menard et al. Nucl. Fusion (2012) 083015]. Analysis of the discharges showed that standard sawtooth models (full/partial reconnection models) in the TRANSP code were not capable to fully reproduce the fast ion redistribution induced by sawtooth crashes. Some global parameters such as neutron rate can be recovered while detailed features, e.g. distribution functions, estimated using the models were different from the experimental observation. The standard sawtooth models in TRANSP do not take into account the different effect of sawtooth crashes depending on fast ion energy and orbit type and that may cause the disagreement between experiments and simulations. In this work, the newly developed kick model has been applied to replace the standard sawtooth models for the fast ion transport. TRANSP simulation results using the kick model, taking into account the characteristics of fast ion such as energy and pitch angle, can reproduce experimental neutron rates within 10\% difference. The qualitative comparison of the measurements and synthetic diagnostics of FIDA and SSNPA using the TRANSP simulation results with kick model demonstrates good agreements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of fast ion pressure in the isotope effect in JET L-mode plasmas

This paper presents results of JET ITER-like wall L-mode experiments in hydrogen and deuterium (D) plasmas, dedicated to the study of the isotope dependence of ion heat transport by determination of the ion critical gradient and stiffness by varying the ion cyclotron resonance heating power deposition. When no strong role of fast ions in the plasma core is expected, the main difference between the two isotope plasmas is determined by the plasma edge and the core behavior is consistent with a gyro-Bohm scaling. When the heating power (and the fast ion pressure) is increased, in addition to the difference in the edge region, also the plasma core shows substantial changes. The stabilization of ion heat transport by fast ions, clearly visible in D plasmas, appears to be weaker in H plasmas, resulting in a higher ion heat flux in H with apparent anti-gyro-Bohm mass scaling. The difference is found to be caused by the different fast ion pressure between H and D plasmas, related to the heating power settings and to the different fast ion slowing down time, and is completely accounted for in non-linear gyrokinetic simulations. The application of the TGLF quasi-linear model to this set of data is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling of sawtooth-induced fast ion transport in positive and negative triangularity in TCV

Internal kinks are a common magneto hydro-dynamic (MHD) instability observed in tokamak operation when the q profile in the plasma core is close to unity. This MHD instability impacts both the transport of the bulk plasma (current, particle and energy transport) and minority species, such as fast ions. In TCV (R 0 /a = 0.88 m/0.25 m) the fast ion population is generated in the plasma by neutral beam tangential injection of energies up to 28 keV. TCV features 16 active shaping coils permitting a great flexibility in plasma shape, including negative triangularity (δ) configurations that show surprisingly high confinement. This study focuses on the transport of fast ions induced by sawteeth, by comparing two triangularity cases and simulation results with experimental data. Comparison of two equilibria with opposite δ shows that the fast ion drifts are larger for δ < 0. Furthermore, the sawtooth-induced transport in this case is larger than δ > 0 in similar conditions. Additionally, comparison with experimental data confirms the dominance of the modification of thermal kinetic profiles following the sawtooth crash in explaining drops in the neutron rates and FIDA signals. Additional fast ion diffusion, however, improves the interpretation of the experimental data. For δ < 0, the amplitude of the perturbation better representing the experimental data is larger. Finaly, an exploratory study for 50 keV particles (soon available in TCV) shows that the situation does not worsen for such particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion confinement in quasi-axisymmetric stellarator equilibria

This report presents an initial analysis of the fast ion confinement and losses within quasi-axisymmetric stellarator equilibria in consideration by Thea Energy. The equilibria have not yet been explicitly optimized for fast particle confinement and require validation. Modeling with the ASCOT5 code is used to directly examine the fast ion transport. The particle tracking simulations are purely (neo)classical in nature and simply contain the supplied equilibrium and collisions (pitch-angle, energy slowing, and velocity diffusion) from supplied thermal profiles. Uniform marker deposition is used to probe the general confinement properties of the equilibria while a realistic beam-born population is provided from the BEAMS3D code and an alpha particle population is calculated from a fusion source integrator. A first wall is included and defines the loss boundary. Analysis for NBI ions within Thea Energy’s conceptual Eos neutron source are presented along with alpha particles in an enlarged DT-plasma. The fast ions are assessed in regards to their confinement time, pitch, energy, and spatial coordinates. For each population, the impact of collisions and orbit drifts are discussed. It is found that NBI born ions in Eos are strongly confined until slowing-down, owing largely to the tangential injection geometry, while 22% of DT-born alpha energy is lost in the scaled device, indicating that any fusion pilot plant design optimization should include metrics for fast ion confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Ion Transport in the Three-Dimensional Reversed-Field Pinch

Here, we report on the first comprehensive experimental and numerical study of fast ion transport in the helical reversed-field pinch (RFP). Classical orbit effects dominate the macroscopic confinement properties. The strongest effect arises from growth in the dominant fast ion guiding-center island, but substantial influence from remnant subdominant tearing modes also plays a critical role. At the formation of the helical RFP, neutron flux measurements indicate a drastic loss of fast ions at sufficient subdominant mode amplitudes. Simulations corroborate these measurements and suggest that subdominant tearing modes strongly limit fast ion behavior. Previous work details a sharp thermal transport barrier and suggests the helical RFP as an Ohmically heated fusion reactor candidate; the enhanced transport of fast ions reported here identifies a key challenge for this scheme, but a workable scenario is conceivable with low subdominant tearing mode amplitudes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance of the NIRS fast scanning system for heavy-ion radiotherapy

Purpose: A project to construct a new treatment facility, as an extension of the existing HIMAC facility, has been initiated for the further development of carbon-ion therapy at NIRS. This new treatment facility is equipped with a 3D irradiation system with pencil-beam scanning. The challenge of this project is to realize treatment of a moving target by scanning irradiation. To achieve fast rescanning within an acceptable irradiation time, the authors developed a fast scanning system. Methods: In order to verify the validity of the design and to demonstrate the performance of the fast scanning prior to use in the new treatment facility, a new scanning-irradiation system was developed and installed into the existing HIMAC physics-experiment course. The authors made strong efforts to develop (1) the fast scanning magnet and its power supply, (2) the high-speed control system, and (3) the beam monitoring. The performance of the system including 3D dose conformation was tested by using the carbon beam from the HIMAC accelerator. Results: The performance of the fast scanning system was verified by beam tests. Precision of the scanned beam position was less than {+-}0.5 mm. By cooperating with the planning software, the authors verified the homogeneity of the delivered field within {+-}3% for the 3D delivery. This system took only 20 s to deliver the physical dose of 1 Gy to a spherical target having a diameter of 60 mm with eight rescans. In this test, the average of the spot-staying time was considerably reduced to 154 {mu}s, while the minimum staying time was 30 {mu}s. Conclusions: As a result of this study, the authors verified that the new scanning delivery system can produce an accurate 3D dose distribution for the target volume in combination with the planning software.

60 APPLIED LIFE SCIENCES↗

Preliminary investigations for the option to use fast uniform scanning with compensators on a gantry designed for IMPT

Purpose: In this experimental study, the authors explored the possibility to deliver the dose for proton therapy with fast uniform scanning on a gantry primarily designed for the delivery of conformal beam scanning and IMPT. The uniform scanning submode has been realized without equipment modifications by using the same small pencil beam used for conformal scanning, resulting in reduced realization costs. Uniform scanning has recently been adopted in a few proton therapy centers, as a basic beam delivery solution, and as an alternative to the use of scattering foils. The option to use such a mode to mimic scattering on a full-fledged scanning gantry could be of interest for treating some specific indications and as a possible solution for treating moving targets. Methods: Uniform iso-energy dose layers were painted by fast magnetic scanning alternated with fast energy changes with the gantry beam line. The layers were stacked and repainted appropriately to produce homogeneous three-dimensional dose distributions. A collimator/compensator was used to adjust the dose to coincide laterally/distally with the target volume. In addition, they applied volumetric repainting, since they are confident that this will further mitigate the effects of organ motion as compared with the presently used clinical scanning solutions. With the approach presented in this paper, they can profit from the higher flexibility of the scanning system to obtain additional advantages. For instance the shape of the energy layers can be adjusted to the projected target shape in order to reduce treatment time and neutrons produced in the collimator. The shape of the proximal layers can be shrunk, according to the cross section of the target at the corresponding range. This provides variable range modulation (proximal conformity) while standard scattering only provides fixed range modulation with unnecessary 100% dose proximal to the target. The field-specific hardware for a spherical target volume was mounted on the Gantry 2 nozzle. One field with proximal field size shrinking and one without, each of 1 Gy, were delivered. The dose distributions at different depths were recorded as CCD images of a scintillating screen. Results: The time to scan the volume once was about 4 s and the total delivery time was approximately 30 s. For the field with proximal conformity, dose sparing of up to 25% was measured in the region proximal to the target. A repainting capability of 48 times was achieved on the most distal layer. The proximal layers were repainted more due to the contribution of the plateau dose from the deeper layers. Conclusions: The flexibility of a fast scanning gantry with very fast energy changes can easily provide beam delivery by uniform layer stacking with a significant degree of volumetric repainting and with the benefit of a dose reduction proximal to the target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-03: MR-Based Cortical Bone Segmentation for PET Attenuation Correction with a Non-UTE 3D Fast GRE Sequence

Purpose: To determine the feasibility of identifying cortical bone on MR images with a short-TE 3D fast-GRE sequence for attenuation correction of PET data in PET/MR. Methods: A water-fat-bone phantom was constructed with two pieces of beef shank. MR scans were performed on a 3T MR scanner (GE Discovery™ MR750). A 3D GRE sequence was first employed to measure the level of residual signal in cortical bone (TE{sub 1}/TE{sub 2}/TE{sub 3}=2.2/4.4/6.6ms, TR=20ms, flip angle=25°). For cortical bone segmentation, a 3D fast-GRE sequence (TE/TR=0.7/1.9ms, acquisition voxel size=2.5×2.5×3mm{sup 3}) was implemented along with a 3D Dixon sequence (TE{sub 1}/TE{sub 2}/TR=1.2/2.3/4.0ms, acquisition voxel size=1.25×1.25×3mm{sup 3}) for water/fat imaging. Flip angle (10°), acquisition bandwidth (250kHz), FOV (480×480×144mm{sup 3}) and reconstructed voxel size (0.94×0.94×1.5mm{sup 3}) were kept the same for both sequences. Soft tissue and fat tissue were first segmented on the reconstructed water/fat image. A tissue mask was created by combining the segmented water/fat masks, which was then applied on the fast-GRE image (MRFGRE). A second mask was created to remove the Gibbs artifacts present in regions in close vicinity to the phantom. MRFGRE data was smoothed with a 3D anisotropic diffusion filter for noise reduction, after which cortical bone and air was separated using a threshold determined from the histogram. Results: There is signal in the cortical bone region in the 3D GRE images, indicating the possibility of separating cortical bone and air based on signal intensity from short-TE MR image. The acquisition time for the 3D fast-GRE sequence was 17s, which can be reduced to less than 10s with parallel imaging. The attenuation image created from water-fat-bone segmentation is visually similar compared to reference CT. Conclusion: Cortical bone and air can be separated based on intensity in MR image with a short-TE 3D fast-GRE sequence. Further research is required to optimize the strategy to reduce Gibbs artifacts.

60 APPLIED LIFE SCIENCES↗

Non-self-sustained glow discharge with electrostatic confinement of electrons sustained by a fast neutral molecule beam

Experimental study of plasma produced at the nitrogen pressure 0.2-1 Pa in the chamber volume V Almost-Equal-To 0.12 m{sup 3} as a result of injection into the chamber of a broad nitrogen molecule beam with 1-4 keV energy and 0.1-1 A equivalent current is carried out, and the study results are presented. Dependences of the plasma density distribution on the beam equivalent current I{sub b}, energy E{sub b}, and gas pressure p indicate a crucial role of fast molecules in gas ionization, and the probe characteristics reveal two groups of plasma electrons with the temperatures T{sub e} {approx} 0.4 eV and T{sub e} {approx} 16 eV. Immersion in plasma of an electrode isolated from the chamber and application to the electrode of a positive voltage U result in non-self-sustained discharge. When U changes from {approx}0.5 to {approx}1.5 V, the discharge current I rapidly rises to a certain value I*, and after that the rate of rise dI/dU drops by an order of magnitude. At U {approx} 10 V, the current I rises to I{sub 0} Almost-Equal-To 1.5I*, and dI/dU once again drops by an order of magnitude. Current I{sub 0} specifies the number of electrons produced inside the chamber per second, and it grows up with E{sub b}, I{sub b}, and p. At U > 20 V, due to gas ionization by fast electrons emitted by the chamber and accelerated up to the energy {approx}eU in the sheath between the plasma and the chamber walls, the current I rises again. When U grows up to {approx}50 V, production of fast electrons with energies exceeding the ionization threshold begins inside the sheath, and the ionization intensity rises dramatically. At U > 150 V, contribution of fast electrons to gas ionization already exceeds the contribution of fast molecules, and the plasma density and its distribution homogeneity inside the chamber both grow up substantially. However, even in this case, the discharge is non-self-sustained, and only at U > 300 V it does not expire when the beam source is switched off.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Charge-Driven Li Plating on Anode and Structural Degradation of Cathode

Enabling fast charging in lithium ion batteries (LIBs) is a key factor to make electric vehicles drive just like gasoline-powered vehicles when the time comes to refuel. However, fast charging to current LIBs (LiNi x Mn y Co 1–z O 2 /graphite) is limited by lithium plating, which is barely reversible and causes LIBs to lose capacity over time. Thus, research to quantify the lithium plating in LIB cells is extremely important in improving our fundamental understanding of lithium plating behavior and enabling fast charging for LIBs. Here, we precisely quantified the amount of fast-charge-driven lithium plating in a coin-cell composed of LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532)/graphite. We found that the amount of lithium plating gradually increases with the cycle count and reaches 25.59 μmole (26.80 mAh g –1 cathode ) by the 100th cycle. The study also reveals that the NMC532 has lost 19% of its original lithium content after 100 fast-charging cycles; this, correspondingly, causes a lattice volumetric strain of 0.59%.

25 ENERGY STORAGE↗

Across-Depth Heterogeneity and Irreversibility of Fast-Charge-Driven Lithium Plating

Enabling fast charging in lithium-ion batteries (LIBs) is a key factor for resolving consumers’ “range anxiety” concerns in choosing an electric vehicle over a gasoline-powered one. The best-known issue in the fast charging of current LIBs (based on LiNi x Mn y Co 1–x–y O 2 /graphite) is lithium plating, which is barely reversible and is accompanied by capacity loss over time. Therefore, understanding the reasons for the irreversibility of lithium plating driven by fast charging is critical to enhancing the fast-charging capability of LIBs. Here, a study of the irreversibility and heterogeneity of lithium plating is carried out by using electrochemical analyses, inductively coupled plasma mass spectroscopy, and X-ray photoelectron spectroscopy. Further, the study shows that the majority of the lithium plated during fast charging remains inactive even with very slow discharging rates, implying that most of the plated lithium is irreversibly lost. The study also reveals that chemical compounds such as LiF, Li 2 O and Li 2 (CO 3 ) are formed heterogeneously within the lithium plating and are responsible for some of the irreversibility of the plated lithium.

33 ADVANCED PROPULSION SYSTEMS↗

A fast comparative genome browser for diverse bacteria and archaea

Genome sequencing has revealed an incredible diversity of bacteria and archaea, but there are no fast and convenient tools for browsing across these genomes. It is cumbersome to view the prevalence of homologs for a protein of interest, or the gene neighborhoods of those homologs, across the diversity of the prokaryotes. We developed a web-based tool, fast . genomics , that uses two strategies to support fast browsing across the diversity of prokaryotes. First, the database of genomes is split up. The main database contains one representative from each of the 6,377 genera that have a high-quality genome, and additional databases for each taxonomic order contain up to 10 representatives of each species. Second, homologs of proteins of interest are identified quickly by using accelerated searches, usually in a few seconds. Once homologs are identified, fast . genomics can quickly show their prevalence across taxa, view their neighboring genes, or compare the prevalence of two different proteins. Fast . genomics is available at https://fast.genomics.lbl.gov .

59 BASIC BIOLOGICAL SCIENCES↗

Electron Generation and Transport in Intense Relativistic Laser-Plasma Interactions Relevant to Fast Ignition ICF

The reentrant cone approach to Fast Ignition, an advanced Inertial Confinement Fusion scheme, remains one of the most attractive because of the potential to efficiently collect and guide the laser light into the cone tip and direct energetic electrons into the high density core of the fuel. However, in the presence of a preformed plasma, the laser energy is largely absorbed before it can reach the cone tip. Full scale fast ignition laser systems are envisioned to have prepulses ranging between 100 mJ to 1 J. A few of the imperative issues facing fast ignition, then, are the conversion efficiency with which the laser light is converted to hot electrons, the subsequent transport characteristics of those electrons, and requirements for maximum allowable prepulse this may put on the laser system. This dissertation examines the laser-to-fast electron conversion efficiency scaling with prepulse for cone-guided fast ignition. Work in developing an extreme ultraviolet imager diagnostic for the temperature measurements of electron-heated targets, as well as the validation of the use of a thin wire for simultaneous determination of electron number density and electron temperature will be discussed.

42 ENGINEERING↗

Indirectly detected chemical shift correlation NMR spectroscopy in solids under fast magic angle spinning

The development of fast magic angle spinning (MAS) opened up an opportunity for the indirect detection of insensitive low-γ nuclei (e.g., 13 C and 15 N) via the sensitive high-{gamma} nuclei (e.g., 1 H and 19 F) in solid-state NMR, with advanced sensitivity and resolution. In this thesis, new methodology utilizing fast MAS is presented, including through-bond indirectly detected heteronuclear correlation (HETCOR) spectroscopy, which is assisted by multiple RF pulse sequences for 1 H- 1 H homonuclear decoupling. Also presented is a simple new strategy for optimization of 1 H- 1 H homonuclear decoupling. As applications, various classes of materials, such as catalytic nanoscale materials, biomolecules, and organic complexes, are studied by combining indirect detection and other one-dimensional (1D) and two-dimensional (2D) NMR techniques. Indirectly detected through-bond HETCOR spectroscopy utilizing refocused INEPT (INEPTR) mixing was developed under fast MAS (Chapter 2). The time performance of this approach in 1 H detected 2D 1 H{l_brace} 13 C{r_brace} spectra was significantly improved, by a factor of almost 10, compared to the traditional 13 C detected experiments, as demonstrated by measuring naturally abundant organic-inorganic mesoporous hybrid materials. The through-bond scheme was demonstrated as a new analytical tool, which provides complementary structural information in solid-state systems in addition to through-space correlation. To further benefit the sensitivity of the INEPT transfer in rigid solids, the combined rotation and multiple-pulse spectroscopy (CRAMPS) was implemented for homonuclear 1 H decoupling under fast MAS (Chapter 3). Several decoupling schemes (PMLG5 m $\bar{x}$ , PMLG5 mm $\bar{x}$x and SAM3) were analyzed to maximize the performance of through-bond transfer based on decoupling efficiency as well as scaling factors. Indirect detection with assistance of PMLG m $\bar{x}$ during INEPTR transfer proved to offer the highest sensitivity gains of 3-10. In addition, the CRAMPS sequence was applied under fast MAS to increase the 1 H resolution during t 1 evolution in the traditional, 13 C detected HETCOR scheme. Two naturally abundant solids, tripeptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (f-MLF-OH) and brown coal, with well ordered and highly disordered structures, respectively, are studied to confirm the capabilities of these techniques. Concomitantly, a simple optimization of 1 H homonuclear dipolar decoupling at MAS rates exceeding 10 kHz was developed (Chapter 4). The fine-tuned decoupling efficiency can be obtained by minimizing the signal loss due to transverse relaxation in a simple spin-echo experiment, using directly the sample of interest. The excellent agreement between observed decoupling pattern and earlier theoretical predictions confirmed the utility of this strategy. The properties of naturally abundant surface-bound fluorocarbon groups in mesoporous silica nanoparticles (MSNs) were investigated by the above-mentioned multidimensional solid-state NMR experiments and theoretical modeling (Chapter 5). Two conformations of (pentafluorophenyl)propyl groups (abbreviated as PFP) were determined as PFP-prone and PFP-upright, whose aromatic rings are located above the siloxane bridges and in roughly upright position, respectively. Several 1D and 2D NMR techniques were implemented in the characterizations, including indirectly detected 1 H{l_brace} 13 C{r_brace} and 19 F{l_brace} 13 C{r_brace} 2D HETCOR, Carr-Purcell-Meiboom-Gill (CPMG) assisted 29 Si direct polarization and 29 Si 19 F 2D experiments, 2D double-quantum (DQ) 19 F MAS NMR spectra and spin-echo measurements. Furthermore, conformational details of two types of PFP were confirmed by theoretical calculation, operated by Dr. Takeshi Kobayashi. Finally, the arrangement of two surfactants, cetyltrimetylammoium bromide (CTAB) and cetylpyridinium bromide (CPB), mixed inside the MSN pores, was studied by solid-state NMR (Chapter 6). By analyzing the 1 H- 1 H DQMAS and NOESY correlation spectra, the CTAB and CPB molecules were shown to co-exist inside the pores without forming significant monocomponent domains. A 'folded-over' conformation of CPB headgroups was proposed according to the results from 1 H- 29 Si 2D HETCOR.

01 COAL, LIGNITE, AND PEAT↗