Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fermilab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Machine learning for slow-extraction uniformity at the Fermilab Delivery Ring

The Muon-to-Electron Conversion Experiment (Mu2e) requires uniform slow extraction from the Fermilab Delivery Ring during each 43 ms spill. This project analyzed 13,737 spills from seven parquet files collected during March and June 2026 commissioning. Each spill contained 430 samples at 0.1 ms resolution and was summarized by the Spill Duty Factor. Null Action and active proportional-integral-derivative conditions established operational baselines. Fixed-ramp sessions were segmented to evaluate reproducibility, drift, and spill-to-spill spread, while a deliberate quadrupole-ramp step identified the beam-response peak and trough. Median profiles were reproducible within fixed conditions but drifted over multi-hour periods. The resulting baselines and response features support future physics-based and machine-learning approaches to real-time spill regulation.

Prescott, Matthew J. [Purdue U., West Lafayette; F↗

Bunch length measurement at the Fermilab A0 photoinjector using a Martin-Puplett interferometer

We present preliminary measurements of the electron bunch lengths at the Fermilab A0 Photoinjector using a Martin-Puplett interferometer on loan from DESY. The photoinjector provides a relatively wide range of bunch lengths through laser pulse width adjustment and compression of the beam using a magnetic chicane. We present comparisons of data with simulations that account for diffraction distortions in the signal and discuss future plans for improving the measurement.

43 PARTICLE ACCELERATORS↗

Transatlantic transport of Fermilab 3.9 GHz cryomodule for TTF/FLASH to DESY

In an exchange of technology agreement, Fermilab built and will deliver a 3.9 GHz (3rd harmonic) cryomodule to DESY to be installed in the TTF/FLASH beamline. This cryomodule delivery will involve a combination of flatbed air ride truck and commercial aircraft transport to Hamburg Germany. A description of the isolation and damping systems that maintain alignment during transport and protect fragile components is provided. Initially, transport and corresponding alignment stability studies were performed in order to assess the risk associated with transatlantic travel of a fully assembled cryomodule. Shock loads were applied to the cryomodule by using a coldmass mockup to prevent subjecting actual critical components (such as the cavities and input couplers) to excessive forces. Accumulative and peak shock loads were applied through over-the-road testing and using a pendulum hammer apparatus, respectively. Finite Element Analysis (FEA) studies were implemented to define location of instrumentation for transport studies and provide modal frequencies and shapes. Shock and vibration measurement results of transport studies and stabilization techniques are discussed.

43 PARTICLE ACCELERATORS↗

GammeV: Fermilab axion-like particle photon regeneration results

GammeV is an axion-like particle photon regeneration experiment conducted at Fermilab that employs the light shining through a wall technique. They obtain limits on the coupling of a photon to an axion-like particle that extend previous limits for both scalar and pseudoscalar axion-like particles in the milli-eV mass range. They are able to exclude the axion-like particle interpretation of the anomalous PVLAS 2006 result by more than 5 standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of 325 MHz single spoke resonators at Fermilab

The High Intensity Neutrino Source (HINS) project represents the current effort at Fermilab to produce an 8-GeV proton linac based on 400 independently phased superconducting cavities. Eighteen ?=0.21 single spoke resonators, operating at 325 MHz, comprise the first stage of the linac cold section. In this paper we present the current status of the production and testing of the first two prototype cavities. This includes descriptions of the fabrication, frequency tuning, chemical polishing, high pressure rinse, and high-gradient cold tests.

43 PARTICLE ACCELERATORS↗

Test Results for HINS Focusing Solenoids at Fermilab

A focusing lens R&D program is close to completion and industrial production of magnets has begun. Two types of magnets are being built for use in the room temperature RF section at the front end of a superconducting H-minus linac of a High Intensity Neutrino Source. All of the magnets are designed as a solenoid with bucking coils to cancel the field in the vicinity of adjacent RF cavities, and one type incorporates steering dipole corrector coils. We present a summary of the predicted and measured quench and magnetic properties for both R&D and production device samples that have been tested at Fermilab.

43 PARTICLE ACCELERATORS↗

The variable input coupler for the Fermilab Vertical Cavity Test Facility

A variable input coupler has been designed for the Fermilab vertical cavity test facility (VCTF), a facility for CW RF vertical testing of bare ILC 1.3 GHz 9-cell SRF cavities at 2K, to provide some flexibility in the test stand RF measurements. The variable coupler allows the cavity to be critically coupled for all RF tests, including all TM010 passband modes, which will simplify or make possible the measurement of those modes with very low end-cell fields, e.g., {pi}/9 mode. The variable coupler assembly mounts to the standard input coupler port on the cavity, and uses a cryogenic motor submerged in superfluid helium to control the antenna position. The RF and mechanical design and RF test results are described.

43 PARTICLE ACCELERATORS↗

GammeV: A gamma to milli-eV particle search at Fermilab

GammeV is an experiment conducted at Fermilab that employs the light shining through a wall technique to search for axion-like particles and employs a particle in a jar technique to search for dilaton-like chameleon particles. We obtain limits on the coupling of photons to an axion-like particle that extend previous limits for both scalars and pseudoscalars in the milli-eV mass range. We are able to exclude the axion-like particle interpretation of the anomalous PVLAS 2006 result by more than 5 standard deviations. We also present results on a search for chameleons and set limits on their possible coupling to photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic shielding for the Fermilab Vertical Cavity Test Facility

A superconducting RF cavity has to be shielded from magnetic fields present during cool down below the critical temperature to avoid freezing in the magnetic flux at localized impurities, thereby degrading the cavity intrinsic quality factor Q{sub 0}. The magnetic shielding designed for the Fermilab vertical cavity test facility (VCTF), a facility for CW RF vertical testing of bare ILC 1.3 GHz 9-cell SRF cavities, was recently completed. For the magnetic shielding design, we used two cylindrical layers: a room temperature 'outer' shield of Amumetal (80% Ni alloy), and a 2K 'inner' shield of Cryoperm 10. The magnetic and mechanical design of the magnetic shielding and measurement of the remanent magnetic field inside the shielding are described.

43 PARTICLE ACCELERATORS↗

A Fast-sampling, Planar Array for Measuring the AC Field of Fermilab Pulsed Extraction Magnets

A system employing a planar array of inductive pick-up coils has been developed for measurements of the rapidly changing dipole field in pulsed extraction magnets for the Fermilab MuCool project. The magnets are of C-type and deigned to support a peak field of 0.65 T during 8.33 millisecond half-sine pulse at a 15 Hz repetition rate. The coils of the measurement system are fabricated on a single, 97.5 mm wide, 2-layer circuit board. The array of coils is simultaneously sampled at data rates of up to 100 kHz with 10 kHz bandwidth using 24-bit ADC's. A detailed overview of the system and data analysis is presented, along with a characterization of results and system performance.

43 PARTICLE ACCELERATORS↗

Test Results of the AC Field Measurements of Fermilab Booster Corrector Magnets

Multi-element corrector magnets are being produced at Fermilab that enable correction of orbits and tunes through the entire cycle of the Booster, not just at injection. The corrector package includes six different corrector elements--normal and skew orientations of dipole, quadrupole, and sextupole--each independently powered. The magnets have been tested during typical AC ramping cycles at 15Hz using a fixed coil system to measure the dynamic field strength and field quality. The fixed coil is comprised of an array of inductive pick-up coils around the perimeter of a cylinder which are sampled simultaneously at 100 kHz with 24-bit ADC's. The performance of the measurement system and a summary of the field results are presented and discussed.

43 PARTICLE ACCELERATORS↗

Collimation system for beam loss localization with slip stacking injection in the Fermilab Main Injector

Slip stacking injection for high intensity operation of the Fermilab Main Injector produces a small fraction of beam which is not captured in buckets and accelerated. A collimation system has been implemented with a thin primary collimator to define the momentum aperture at which this beam is lost and four massive secondary collimators to capture the scattered beam. The secondary collimators define tight apertures and thereby capture a fraction of other lost beam. The system was installed in 2007 with commissioning continuing in 2008. The collimation system will be described including simulation, design, installation, and commissioning. Successful operation and operational limitations will be described.

43 PARTICLE ACCELERATORS↗

Overview of the High Intensity Neutrino Source Linac R&D program at Fermilab

The Fermilab High Intensity Neutrino Source (HINS) Linac R&D program is building a first-of-a-kind 60 MeV superconducting H- linac. The HINS Linac incorporates superconducting solenoids for transverse focusing, high power RF vector modulators for independent control of multiple cavities powered from a single klystron, and superconducting spoke-type accelerating cavities starting at 10 MeV. This will be the first application and demonstration of any of these technologies in a low-energy, high-intensity proton/H- linear accelerator. The HINS effort is relevant to a high intensity, superconducting H- linac that might serve the next generation of neutrino physics and muon storage ring/collider experiments. An overview of the HINS program, machine design, status, and outlook is presented.

43 PARTICLE ACCELERATORS↗

A fast chopper for the Fermilab High Intensity Neutrino Source (HINS)

A fast chopper capable of kicking single 2.5 MeV H-bunches spaced at 325 MHz, at rates greater than 50 MHz is needed for the Fermilab High Intensity Neutrino Source (HINS) [1]. Four 1.2 kV fast pulsers, designed and manufactured by Kentech Instruments Ltd., will drive a 0.5 m long meander made from a copper plated ceramic composite. Test results showing pulses from the first 1.2 kV pulser and meander results will be presented.

43 PARTICLE ACCELERATORS↗

Landau damping of space-charge dominated Fermilab Booster beam

The stable region of the Fermilab Booster beam in the complex coherent-tune-shift plane appears to have been shifted far away from the origin by its intense space-charge making Landau damping impossible. However, it is shown that the bunching structure of the beam reduces the mean space-charge tune shift. As a result, the beam can be stabilized by suitable octupole-driven tune spread.

43 PARTICLE ACCELERATORS↗

The NuMI proton beam at Fermilab successes and challenges

The NuMI beam at Fermilab has delivered over 5 x 10{sup 20} 120 GeV protons to the neutrino production target since the start for MINOS [1] neutrino oscillation experiment operation in 2005. We report on proton beam commissioning and operation status, including successes and challenges with this beam.

43 PARTICLE ACCELERATORS↗

Stability of electron energy in the Fermilab electron cooler

A powerful electron beam (4.3 MeV, 0.1 A DC) generated by an electrostatic accelerator has been used at Fermilab for three years to cool antiprotons in the Recycler ring. For electron cooling to be effective, the electron energy should not deviate from its optimum value by more than 500V. The main tool for studying the energy stability is the electron beam position in a high-dispersion area. The energy ripple (frequencies above 0.2 Hz) was found to be less than 150 eV rms; the main cause of the ripple is the fluctuations of the chain current. In addition, the energy can drift to up to several keV that is traced to two main sources. One of them is a drift of the charging current, and another is a temperature dependence of generating voltmeter readings. The paper describes the efforts to reach the required level of stability as well as the setup, diagnostics, results of measurements, and operational experience.

43 PARTICLE ACCELERATORS↗

Recent ground motion studies at Fermilab

Understanding slow and fast ground motion is important for the successful operation and design for present and future colliders. Since 2000 there have been several studies of ground motion at Fermilab. Several different types of HLS (hydro static level sensors) have been used to study slow ground motion (less than 1 hertz) seismometers have been used for fast (greater than 1 hertz) motions. Data have been taken at the surface and at locations 100 meters below the surface. Data of recent slow ground motion measurements with HLSs, many years of alignment data and results of the ATL-analysis are presented and discussed.

43 PARTICLE ACCELERATORS↗