Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DISPERSION OF MAGNETIC FIELDS IN MOLECULAR CLOUDS. III

We apply our technique on the dispersion of magnetic fields in molecular clouds to high spatial resolution Submillimeter Array polarization data obtained for Orion KL in OMC-1, IRAS 16293, and NGC 1333 IRAS 4A. We show how one can take advantage of such high-resolution data to characterize the magnetized turbulence power spectrum in the inertial and dissipation ranges. For Orion KL we determine that in the inertial range the spectrum can be approximately fitted with a power law k{sup -(2.9{+-}0.9)} and we report a value of 9.9 mpc for {lambda}{sub AD}, the high spatial frequency cutoff presumably due to turbulent ambipolar diffusion. For the same parameters we have {approx}k{sup -(1.4{+-}0.4)} and a tentative value of {lambda}{sub AD} {approx_equal} 2.2 mpc for NGC 1333 IRAS 4A, and {approx}k{sup -(1.8{+-}0.3)} with an upper limit of {lambda}{sub AD} {approx}< 1.8 mpc for IRAS 16293. We also discuss the application of the technique to interferometry measurements and the effects of the inherent spatial filtering process on the interpretation of the results.

79 ASTRONOMY AND ASTROPHYSICS↗

CfA4: LIGHT CURVES FOR 94 TYPE Ia SUPERNOVAE

We present multi-band optical photometry of 94 spectroscopically confirmed Type Ia supernovae (SNe Ia) in the redshift range 0.0055-0.073, obtained between 2006 and 2011. There are a total of 5522 light-curve points. We show that our natural-system SN photometry has a precision of {approx}< 0.03 mag in BVr'i', {approx}< 0.06 mag in u', and {approx}< 0.07 mag in U for points brighter than 17.5 mag and estimate that it has a systematic uncertainty of 0.014, 0.010, 0.012, 0.014, 0.046, and 0.073 mag in BVr'i'u'U, respectively. Comparisons of our standard-system photometry with published SN Ia light curves and comparison stars reveal mean agreement across samples in the range of {approx}0.00-0.03 mag. We discuss the recent measurements of our telescope-plus-detector throughput by direct monochromatic illumination by Cramer et al. This technique measures the whole optical path through the telescope, auxiliary optics, filters, and detector under the same conditions used to make SN measurements. Extremely well characterized natural-system passbands (both in wavelength and over time) are crucial for the next generation of SN Ia photometry to reach the 0.01 mag accuracy level. The current sample of low-z SNe Ia is now sufficiently large to remove most of the statistical sampling error from the dark-energy error budget. But pursuing the dark-energy systematic errors by determining highly accurate detector passbands, combining optical and near-infrared (NIR) photometry and spectra, using the nearby sample to illuminate the population properties of SNe Ia, and measuring the local departures from the Hubble flow will benefit from larger, carefully measured nearby samples.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal MEMS actuator operation in aqueous media/seawater: Performance enhancement through atomic layer deposition post processing of PolyMUMPs devices

A method to enhance thermal microelectromechanical systems (MEMS) actuators in aqueous media by using dielectric encapsulation layers is presented. Aqueous media reduces the available mechanical energy of the thermal actuator through an electrical short between actuator structures. Al{sub 2}O{sub 3} and TiO{sub 2} laminates with various thicknesses were deposited on packaged PolyMUMPs devices to electrically separate the actuator from the aqueous media. Atomic layer deposition was used to form an encapsulation layer around released MEMS structures and the package. The enhancement was assessed by the increase of the elastic energy, which is proportional to the mechanical stiffness of the actuator and the displacement squared. The mechanical stiffness of the encapsulated actuators compared with the noncoated actuators was increased by factors ranging from 1.45 (for 45 nm Al{sub 2}O{sub 3} + 20 nm TiO{sub 2}) to 1.87 (for 90 nm Al{sub 2}O{sub 3} + 40 nm TiO{sub 2}). Displacement measurements were made for all laminate combinations in filtered tap water and seawater by using FFT based displacement measurement technique with a repeatability of ∼10 nm. For all laminate structures, the elastic energy increased and enhanced the actuator performance: In seawater, the mechanical output energy increased by factors ranging from 5 (for 90 nm Al{sub 2}O{sub 3}) to 11 (for 90 nm Al{sub 2}O{sub 3} + 40 nm TiO{sub 2}). The authors also measured the long-term actuator stability/reliability in seawater. Samples were stored for 29 days in seawater and tested for 17 days in seawater. Laminates with TiO{sub 2} layers allowed constant operation over the entire measurement period.

36 MATERIALS SCIENCE↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring

The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on plant parameters and the pump electrical signatures. Additionally, the reactor simulation is being used to generate normal operation data and data with instrumentation faults and process anomalies. A frequency controller was interfaced with the motor power supply in order to vary the electrical supply frequency. The experimental flow control loop was used to generate operational data under varying motor performance characteristics. Coolant leakage events were simulated by varying the bypass loop flow rate. The accuracy of motor power calculation was improved by incorporating the power factor, computed from motor current and voltage in each phase of the induction motor.- A variety of experimental runs were made for steady-state and transient pump operating conditions. Process, vibration, and electrical signatures were measured using a submersible pump with variable supply frequency. High correlation was seen between motor current and pump discharge pressure signal; similar high correlation was exhibited between pump motor power and flow rate. Wide-band analysis indicated high coherence (in the frequency domain) between motor current and vibration signals. - Wide-band operational data from a PWR were acquired from AMS Corporation and used to develop time-series models, and to estimate signal spectrum and sensor time constant. All the data were from different pressure transmitters in the system, including primary and secondary loops. These signals were pre-processed using the wavelet transform for filtering both low-frequency and high-frequency bands. This technique of signal pre-processing provides minimum distortion of the data, and results in a more optimal estimation of time constants of plant sensors using time-series modeling techniques.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Massively Scalable Near Duplicate Detection in Streams of Documents using MDSH

In a world where large-scale text collections are not only becoming ubiquitous but also are growing at increasing rates, near duplicate documents are becoming a growing concern that has the potential to hinder many different information filtering tasks. While others have tried to address this problem, prior techniques have only been used on limited collection sizes and static cases. We will briefly describe the problem in the context of Open Source Intelligence (OSINT) along with our additional constraints for performance. In this work we propose two variations on Multi-dimensional Spectral Hash (MDSH) tailored for working on extremely large, growing sets of text documents. We analyze the memory and runtime characteristics of our techniques and provide an informal analysis of the quality of the near-duplicate clusters produced by our techniques.

Bogen, Paul Logasa↗

Methods and apparatus for broadband frequency comb stabilization

Feedback loops can be used to shift and stabilize the carrier-envelope phase of a frequency comb from a mode-locked fibers laser or other optical source. Compared to other frequency shifting and stabilization techniques, feedback-based techniques provide a wideband closed-loop servo bandwidth without optical filtering, beam pointing errors, or group velocity dispersion. It also enables phase locking to a stable reference, such as a Ti:Sapphire laser, continuous-wave microwave or optical source, or self-referencing interferometer, e.g., to within 200 mrad rms from DC to 5 MHz. In addition, stabilized frequency combs can be coherently combined with other stable signals, including other stabilized frequency combs, to synthesize optical pulse trains with pulse durations of as little as a single optical cycle. Such a coherent combination can be achieved via orthogonal control, using balanced optical cross-correlation for timing stabilization and balanced homodyne detection for phase stabilization.

42 ENGINEERING↗

Cross sections for fast-neutron interaction with Lu, Tb, and Ta isotopes

The cross sections for (n,x) reactions with Lu, Tb, and Ta isotopes were measured at (d,t) neutron energies around 14 MeV with the activation technique using metal foils of natural composition. Additionally, tantalum samples were irradiated with (d,d) neutrons and filtered neutron beams. To ensure an acceptable precision of the results all major sources of uncertainties were taken into account. Calculations of efficiency and correction factors were performed with the Monte Carlo technique. The cross section results obtained for the {sup 175}Lu(n,{alpha}){sup 172}Tm reaction at (d,t) neutron energies are reported for the first time. {sup 181}Ta(n,{gamma}){sup 182}Ta{sup m2} reaction cross sections were also measured for the first time at 1.9, 58.7, and 144.3 keV and at 2.85 MeV. The earlier evaluated cross section upper estimate for the nuclear reaction {sup 159}Tb(n,n{sup '}{alpha}){sup 155}Eu is reported in this article to be one order lower. Some other cross sections were obtained with higher precision. Theoretical calculations of excitation functions were performed with the TALYS-1.0 code and compared with the experimental cross section values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchtop assessment of sealing efficacy and breathability of additively manufactured (AM) face masks

The onset of the 2019 novel coronavirus disease (COVID-19) led to a shortage of personal protective equipment (PPE), medical devices, and other medical supplies causing many stakeholders and the general public alike to turn to additive manufacturing (AM) as a stopgap when normally accessible devices were not available. However, without a method to test these AM constructs, there continued to be a disconnect between AM suppliers and the community’s needs. The objective of this study was to characterize the pressure drop and leakage of four different publicly available AM face mask models with two filter material combinations, as well as to investigate the impact of frame modification techniques including the use of foam strips and hot-water face forming to improve fit when the masks are donned on manikin head forms. AM face mask frame designs were downloaded from public repositories during the early stages of the COVID-19 pandemic. AM face masks were fabricated and tested on manikin head forms within a custom chamber containing dry aerosolized NaCl. Pressure drops, particle penetration, and leakage were evaluated for various flow rates and NaCl concentrations. Results indicated that filter material combination and frame modification played a major role in the overall performance of the AM face masks studied. Filter material combinations showed improved performance when high filtration fabric was used, and the cross-sectional area of the fabric was increased. AM frame modifications appeared to improve AM face mask leakage performance by as much as 69.6%.

36 MATERIALS SCIENCE↗

The Uniaxial Tensile Response of Porous and Microcracked Ceramic Materials

The uniaxial tensile stress-strain behavior of three porous ceramic materials was determined at ambient conditions. Test specimens in the form of thin beams were obtained from the walls of diesel particulate filter honeycombs and tested using a microtesting system. A digital image correlation technique was used to obtain full-field 2D in-plane surface displacement maps during tensile loading, and in turn, the 2D strains obtained from displacement fields were used to determine the Secant modulus, Young s modulus and initial Poisson s ratio of the three porous ceramic materials. Successive unloading-reloading experiments were performed at different levels of stress to decouple the linear elastic, anelastic and inelastic response in these materials. It was found that the stress-strain response of these materials was non-linear and that the degree of nonlinearity is related to the initial microcrack density and evolution of damage in the material.

anelasticity↗

Studies of sheath characteristics in a double plasma device with a negatively biased separating grid and a magnetic filter field

A double plasma device has two regions: Source region and target region. These two regions are divided by a magnetic filter field. A grid is placed coplanar to the magnetic filter. To study the sheath structure in the target region, a metallic plate is placed at the center, which can be biased with respect to the chamber (ground) potential. Plasma is created in the source region by filament discharge technique. Plasma diffusing from the source region to the target region is subjected to the magnetic filter field and also an electric field applied on the grid. Plasma thus obtained in the target region forms a sheath on the biased plate. The influence of both the magnetic filter field and the electric field, applied between the grid and the chamber wall, on the sheath structure formed on the biased plate is studied. It is found that the magnetic filter field and the electric field change the sheath structure in different ways.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of frequency selective surface for band stop IR-filter

Fabrication and characterization of frequency selective surfaces (FSS) on silicon dioxide/ silicon is reported. Electron beam lithography based techniques are used for the fabrication of periodic slot structure in tungsten layer on silicon dioxide/silicon. The fabrication process consists of growth of SiO{sub 2} on silicon, tungsten deposition, electron beam lithography, and wet etching of tungsten. The optical characterization of the structural pattern was carried out using fourier transform infrared spectroscopy (FTIR). The reflectance spectra clearly show a resonance peak at 9.09 µm in the mid infrared region. This indicates that the patterned surface acts as band stop filter in the mid-infrared region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive OFDM Waveform Design for Spatio-Temporal-Sparsity Exploited STAP Radar

In this chapter, we describe a sparsity-based space-time adaptive processing (STAP) algorithm to detect a slowly moving target using an orthogonal frequency division multiplexing (OFDM) radar. The motivation of employing an OFDM signal is that it improves the target-detectability from the interfering signals by increasing the frequency diversity of the system. However, due to the addition of one extra dimension in terms of frequency, the adaptive degrees-of-freedom in an OFDM-STAP also increases. Therefore, to avoid the construction a fully adaptive OFDM-STAP, we develop a sparsity-based STAP algorithm. We observe that the interference spectrum is inherently sparse in the spatio-temporal domain, as the clutter responses occupy only a diagonal ridge on the spatio-temporal plane and the jammer signals interfere only from a few spatial directions. Hence, we exploit that sparsity to develop an efficient STAP technique that utilizes considerably lesser number of secondary data compared to the other existing STAP techniques, and produces nearly optimum STAP performance. In addition to designing the STAP filter, we optimally design the transmit OFDM signals by maximizing the output signal-to-interference-plus-noise ratio (SINR) in order to improve the STAP performance. The computation of output SINR depends on the estimated value of the interference covariance matrix, which we obtain by applying the sparse recovery algorithm. Therefore, we analytically assess the effects of the synthesized OFDM coefficients on the sparse recovery of the interference covariance matrix by computing the coherence measure of the sparse measurement matrix. Our numerical examples demonstrate the achieved STAP-performance due to sparsity-based technique and adaptive waveform design.

Sen, Satyabrata↗

Real-time cure monitoring of fiber-reinforced polymer composites using infrared thermography and recursive Bayesian filtering

Despite the desirable characteristics of fiber-reinforced polymer (FRP) composites, their utilization in high volume production industries is limited by a lack of efficient manufacturing techniques. Monitoring the curing process of these composites can help with improving the quality and efficiency of the manufacturing process. This article discusses a method that uses Kalman-filter-based fusion of the information obtained from infrared thermography (surface temperature measurements) and a heat conduction model to estimate degrees of cure and internal temperatures of curing FRP composite parts in real time. The effectiveness of the methodology is demonstrated by successfully monitoring the curing of an FRP composite part in a laboratory experiment. Finally, the proposed methodology is a crucial step towards identifying anomalies in the curing process that negatively impact the quality of FRP composite parts.

36 MATERIALS SCIENCE↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Early arrival waveform inversion using data uncertainties and matching filters with application to near-surface seismic refraction data

We develop an early arrival waveform inversion (EAWI) technique for high-resolution near-surface velocity estimation by iteratively updating the P-wave velocity model to minimize the difference between the observed and calculated seismic refraction data. Traditional EAWI uses a least-squares penalty function and an acoustic forward-modeling engine. Conventional least-squares error is sensitive to data with low signal-to-noise ratio (S/N) and iterations of EAWI stop at a local-minimum data misfit or at the preassigned maximum number of iterations. These stopping criteria can result in overfitting the data. In addition, fitting the elastic field data with an acoustic modeling engine can introduce artifacts in velocity estimation, especially in land data with significant elastic effects. To overcome these challenges, we develop a robust EAWI (REAWI) method by (1) incorporating the data uncertainties into the penalty function and (2) mitigating the elastic effects using a matching filter workflow. The data uncertainties are estimated from waveform reciprocal errors. When full-waveform reciprocity is not available, trace interpolation is applied. The proposed method prevents closely fitting data with low S/N, avoids overall overfitting by stopping the iterations when a normalized chi-square ([Formula: see text]) waveform misfit of one is achieved, and is less affected by elastic effects. Numerical examples and application to near-surface refraction data at a groundwater contamination site suggest that the final REAWI models are more accurate than the corresponding EAWI models, at the same level of misfit. This is the first known application of a matching filter workflow to real land data. The final REAWI models satisfy an appropriate misfit between the real data and predicted elastic P-wave data, making this approach in this respect equivalent to elastic waveform inversion. We also develop a method to analyze model constraint by examining the energy of the wavefield Fréchet derivative thereby avoiding the influence of the data residuals in traditional Fréchet kernels.

Geochemistry & Geophysics↗

A novel method to recover DD fusion proton CR-39 data corrupted by fast ablator ions at OMEGA and the National Ignition Facility

CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗