Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fractionalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

An Investigation of the Effects of Volume Fraction on Drag Coefficient of Non-Spherical Particles Using PR-DNS

Prediction of the drag coefficient is required in gas-particle multiphase flow modeling and simulation. Experimental data and correlations on the fixed-bed system of spherical particles with high volume fractions for various possible arrangements are available in the literature. However, the effect of volume fraction on the drag coefficient of non-spherical particles is not well studied. In solving the momentum equation, the volume fraction plays a vital role in determining the flow resistances. In this paper, we study the impact of volume fraction in the range of 0.069 to 0.65 on the drag coefficient using the computational fluid dynamics (CFD) simulation of air for Reynold number in the range of 10 to 10000 using particle resolved direct numerical solution (PR-DNS). Regular non-spherical particles such as a cube, tetrahedron, and spheroids are used in this study since their single particle’s drag coefficient data are available in the literature for comparison. For this work, the simulations are carried out in the Ansys Fluent using polyhedral mesh, which consumes significantly less computational time and power. The study showed the sphericity and volume fraction have significant impact on the bed pressure drop and average drag coefficient of the particles in the bed especially in high Reynolds number regime. The bed of the spheroid experiences the lowest drag being the most streamlined particle, and the particles with the edges result in a large drag coefficient due to flow separation at the discontinuity. The vector plots verify this behavior where large wake regions are observed behind the tetrahedron particle.

Mahyawansi, Pratik↗

Effect of radiation protraction on BED in the case of large fraction dose

Purpose: To investigate the effect of radiation protraction on biologically effective dose (BED) in the case when dose per fraction is significantly greater than the standard dose of 2 Gy.Methods: By using the modified linear-quadratic model with monoexponential repair, the authors investigate the effect of long treatment times combined with dose escalation.Results: The dependences of the protraction factor and the corresponding BED on fraction time were determined for different doses per fraction typical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). In the calculations, the authors consider changes in the BED to the normal tissue under the condition of fixed BED to the target.Conclusion: The obtained results demonstrate that simultaneous increase in fraction time and dose per fraction can be beneficial for SRS and SBRT because of the related decrease in BED to normal structures while BED to the target is fixed.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-603: Analysis of Optical Tracked Head Inter-Fraction Movements Within Masks to Access Intracranial Immobilization Techniques in Proton Therapy

Purpose: We present a quantitative methodology utilizing an optical tracking system for monitoring head inter-fraction movements within brain masks to assess the effectiveness of two intracranial immobilization techniques. Methods and Materials: A 3-point-tracking method was developed to measure the mask location for a treatment field at each fraction. Measured displacement of mask location to its location at first fraction is equivalent to the head movement within the mask. Head movements for each of treatment fields were measured over about 10 fractions at each patient for seven patients; five treated in supine and two treated in prone. The Q-fix Base-of-Skull head frame was used in supine while the CIVCO uni-frame baseplate was used in prone. Displacements of recoded couch position of each field post imaging at each fraction were extracted for those seven patients. Standard deviation (S.D.) of head movements and couch displacements was scored for statistical analysis. Results: The accuracy of 3PtTrack method was within 1.0 mm by phantom measurements. Patterns of head movement and couch displacement were similar for patients treated in either supine or prone. In superior-inferior direction, mean value of scored standard deviations over seven patients were 1.6 mm and 3.4 mm for the head movement and the couch displacement, respectively. The result indicated that the head movement combined with a loose fixation between the mask-to-head frame results large couch displacements for each patient, and also large variation between patients. However, the head movement is the main cause for the couch displacement with similar magnitude of around 1.0 mm in anterior-posterior and lateral directions. Conclusions: Optical-tracking methodology independently quantifying head movements could improve immobilization devices by correctly acting on causes for head motions within mask. A confidence in the quality of intracranial immobilization techniques could be more efficient by eliminating the need for frequent imaging.

60 APPLIED LIFE SCIENCES↗

Sci—Thur AM: YIS - 11: Estimation of Bladder-Wall Cumulative Dose in Multi-Fraction Image-Based Gynaecological Brachytherapy Using Deformable Point Set Registration

Dosimetric parameters based on dose-volume histograms (DVH) of contoured structures are routinely used to evaluate dose delivered to target structures and organs at risk. However, the DVH provides no information on the spatial distribution of the dose in situations of repeated fractions with changes in organ shape or size. The aim of this research was to develop methods to more accurately determine geometrically localized, cumulative dose to the bladder wall in intracavitary brachytherapy for cervical cancer. The CT scans and treatment plans of 20 cervical cancer patients were used. Each patient was treated with five high-dose-rate (HDR) brachytherapy fractions of 600cGy prescribed dose. The bladder inner and outer surfaces were delineated using MIM Maestro software (MIM Software Inc.) and were imported into MATLAB (MathWorks) as 3-dimensional point clouds constituting the “bladder wall”. A point-set registration toolbox for MATLAB, Coherent Point Drift (CPD), was used to non-rigidly transform the bladder-wall points from four of the fractions to the coordinate system of the remaining (reference) fraction, which was chosen to be the emptiest bladder for each patient. The doses were accumulated on the reference fraction and new cumulative dosimetric parameters were calculated. The LENT-SOMA toxicity scores of these patients were studied against the cumulative dose parameters. Based on this study, there was no significant correlation between the toxicity scores and the determined cumulative dose parameters.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 13: Inter-Fraction Target Movement in Image-Guided Radiation Therapy of Prostate Cancer

We investigated the setup variations over the treatment courses of 113 patients with intact prostate treated with 78Gy/39fx. Institutional standard bladder and bowel preparation and image guidance protocols were used in CT simulation and treatment. The RapidArc treatment plans were optimized in Varian Eclipse treatment planning system and delivered on Varian 2100X Clinacs equipped with On-Board Imager to localize the target before beam-on. The setup variations were calculated in terms of mean and standard deviation of couch shifts. No correlation was observed between the mean shift and standard deviation over the treatment course and patient age, initial prostate volume and rectum size. The mean shifts in the first and last 5 fractions are highly correlated (P < 10{sup −10}) while the correlation of the standard deviations cannot be determined. The Mann-Kendall tests indicate trends of the mean daily Ant-Post and Sup-Inf shifts of the group. The target is inferior by ∼1mm to the planned position when the treatment starts and moves superiorly, approaching the planned position at 10th fraction, and then gradually moves back inferiorly by ∼1mm in the remain fractions. In the Ant-Post direction, the prostate gradually moves posteriorly during the treatment course from a mean shift of ∼2.5mm in the first fraction to ∼1mm in the last fraction. It may be related to a systematic rectum size change in the progress of treatment. The biased mean shifts in Ant-Post and Sup-Inf direction of most patients suggest systematically larger rectum and smaller bladder during the treatment than at CT simulation.

60 APPLIED LIFE SCIENCES↗

TU-AB-303-12: Towards Inter and Intra Fraction Plan Adaptation for the MR-Linac

Purpose: To develop a new sequencer for IMRT that during treatment can account for anatomy changes provided by online and real-time MRI. This sequencer employs a novel inter and intra fraction scheme that converges to the prescribed dose without a final segment weight optimization (SWO) and enables immediate optimization and delivery of radiation adapted to the deformed anatomy. Methods: The sequencer is initially supplied with a voxel-based dose prescription and during the optimization iteratively generates segments that provide this prescribed dose. Every iteration selects the best segment for the current anatomy state, calculates the dose it will deliver, warps it back to the reference prescription grid and subtracts it from the remaining prescribed dose. This process continues until a certain percentage of dose or a number of segments has been delivered. The anatomy changes that occur during treatment require that convergence is achieved without a final SWO. This is resolved by adding the difference between the prescribed and delivered dose up to this fraction to the prescription of the subsequent fraction. This process is repeated for all fractions of the treatment. Results: Two breast cases were selected to stress test the pipeline by producing artificial inter and intra fraction anatomy deformations using a combination of incrementally applied rigid transformations. The dose convergence of the adaptive scheme over the entire treatment, relative to the prescribed dose, was on average 8.6% higher than the static plans delivered to the respective deformed anatomies and only 1.6% less than the static segment weighted plans on the static anatomy. Conclusion: This new adaptive sequencing strategy enables dose convergence without the need of SWO while adapting the plan to intermediate anatomies, which is a prerequisite for online plan adaptation. We are now testing our pipeline on prostate cases using clinical anatomy deformation data from our department. This work is financially supported by Elekta AB, Stockholm, Sweden.

60 APPLIED LIFE SCIENCES↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-12: Impacts of Inter- and Intra-Fractional Organ Motion for High-Risk Prostate Cancer Stereotactic Body Radiation Therapy

Purpose: We are conducting a clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer. Doses to three targets, prostate, intra-prostatic lesion, and pelvic lymph node (PLN) region, are escalated to three different levels via simultaneous integrated boost technique. Inter-/intra-fractional organ motions deteriorate planned dose distribution. This study aims at developing a dose reconstruction system to comprehensively understand the impacts of organ motion in our clinical trial. Methods: A 4D dose reconstruction system has been developed for this study. Using a GPU-based Monte-Carlo dose engine and delivery log file, the system is able to reconstruct dose on static or dynamic anatomy. For prostate and intra-prostatic targets, intra-fractional motion is the main concern. Motion trajectory acquired from Calypso in previously treated SBRT patients were used to perform 4D dose reconstructions. For pelvic target, inter-fractional motion is one concern. Eight patients, each with four cone beam CTs, were used to derive fractional motion. The delivered dose was reconstructed on the deformed anatomy. Dosimetric parameters for delivered dose distributions of the three targets were extracted and compared with planned levels. Results: For prostate intra-fractional motion, the mean 3D motion amplitude during beam delivery ranged from 1.5mm to 5.0mm and the average among all patients was 2.61mm. Inter-fractional motion for the PLN target was more significant. The average amplitude among patients was 4mm with the largest amplitude up to 9.6mm. The D95% deviation from planned level for prostate PTVs and GTVs are on average less than<0.1% and this deviation for intra-prostatic lesion PTVs and GTVs were more prominent. The dose at PLN was significantly affected with D{sub 95}% reduced by up to 44%. Conclusion: Intra-/inter-fractional organ motion is a concern for high-risk prostate SBRT, particularly for the PLN target. Our dose reconstruction approach can also serve as the basis to guide treatment adaptation.

60 APPLIED LIFE SCIENCES↗

Fractional Statistics

The quantum-mechanical description of assemblies of particles whose motion is confined to two (or one) spatial dimensions offers many possibilities that are distinct from bosons and fermions. We call such particles anyons. The simplest anyons are parameterized by an angular phase parameter θ. θ = 0, π correspond to bosons and fermions, respectively; at intermediate values, we say that we have fractional statistics. In two dimensions, θ describes the phase acquired by the wave function as two anyons wind around one another counterclockwise. It generates a shift in the allowed values for the relative angular momentum. Composites of localized electric charge and magnetic flux associated with an abelian U(1) gauge group realize this behavior. More complex charge-flux constructions can involve nonabelian and product groups acting on a spectrum of allowed charges and fluxes, giving rise to nonabelian and mutual statistics. Interchanges of nonabelian anyons implement unitary transformations of the wave function within an emergent space of internal states. Anyons of all kinds are described by quantum field theories that include Chern–Simons terms. The crossings of one-dimensional anyons on a ring are unidirectional, such that a fractional phase θ acquired upon interchange gives rise to fractional shifts in the relative momenta between the anyons. The quasiparticle excitations of fractional quantum Hall states have long been predicted to include anyons. Recently, the anyon behavior predicted for quasiparticles in the ν = 1/3 fractional quantum Hall state has been observed in both scattering and interferometric experiments. Excitations within designed systems, notably including superconducting circuits, can exhibit anyon behavior. Such systems are being developed for possible use in quantum information processing.

Physics↗

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Analysis of Tempered Fractional Operators

Tempered fractional operators provide an improved predictive capability for modeling anomalous effects that cannot be captured by standard partial differential equations. These effects include subdiffusion and superdiffusion (i.e. the mean square displacement in a diffusion process is proportional to a fractional power of the time), that often occur in, e.g., geoscience and hydrology. We analyze tempered fractional operators within the nonlocal vector calculus framework in order to assimilate them to the rigorous mathematical structure developed for nonlocal models. First, we show they are special instances of generalized nonlocal operators by means of a proper choice of the nonlocal kernel. Then, we present a plan for showing tempered fractional operators are equivalent to truncated fractional operators. These truncated operators are useful because they are less computationally intensive than the tempered operators.

97 MATHEMATICS AND COMPUTING↗

Conservative Release Fraction Correlation for Spray Releases

Washington River Protection Solutions, LLC (WRPS) is planning to conduct repairs in the Liquid Effluent Retention Facility (LERF), and prior to conducting this work they will re-evaluate the hazard category designation for LERF. As part of this evaluation, WRPS needs estimates of the release fraction of potential accidental sprays, because a spray release is a potential bounding accident. Pacific Northwest National Laboratory previously developed a conservative correlation for the cumulative generation rate (volume per time) of aerosol droplets less than or equal to specific sizes from spray releases as a function of the spray pressure, orifice area, and droplet diameter. To obtain release fraction estimates from the conservative generation rate correlation, the correlation needs to be recast by dividing the aerosol generation rate by the flow rate of a spray. In the current study, a conservative release fraction correlation was developed from the conservative aerosol generation rate correlation developed previously by dividing the generation rate correlation by the flow rate of a spray using an orifice flow rate equation and then this correlation was adjusted to be conservative. Test data were also extrapolated to a lower pressure than the lowest pressure tested (100 psig) for the spray data used for developing the previous conservative generation rate correlation. The new conservative release fraction correlation was then used to predict release fractions of respirable droplets (droplets = 10 µm) for four specific pipes that are part of LERF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Theoretical Analysis of Fractional Viscoelastic Flow in Circular Pipes: Parametric Study

Pipe flow is one of the most commonly used models to describe fluid dynamics. The concept of fractional derivative has been recently found very useful and much more accurate in predicting dynamics of viscoelastic fluids compared with classic models. In this paper, we capitalize on our previous study and consider space-time dynamics of flow velocity and stress for fractional Maxwell, Zener, and Burgers models. We demonstrate that the behavior of these quantities becomes much more complex (compared to integer-order classical models) when adjusting fractional order and elastic parameters. We investigate mutual influence of fractional orders and consider their limiting value combinations. Finally, we show that the models developed can be reduced to classical ones when appropriate fractional orders are set.

Gritsenko, Dmitry (ORCID:0000000248181512)↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗

On the Structure of the AGN Torus through the Fraction of Optically Selected Type 1 AGNs

The ratio in number between unobscured (type 1) and obscured (type 2) active galactic nuclei (AGNs) is often used to explore the structure of the torus in the unified scheme for AGNs. Oh et al. (2015) investigated the type 1 AGN fraction on two-dimensional space in terms of black hole mass (M{sub BH}) and bolometric luminosity (L{sub bol}) and found that the fraction changes depending on both M{sub BH} and L{sub bol}, forming a ridge-shaped distribution. In this study, based on the up-to-date type 1 AGN catalog of Oh et al. (2015), we examine how the trend of the type 1 AGN fraction in the M{sub BH}–L{sub bol} plane is affected by the different methods used to derive M{sub BH} and L{sub bol}, and suggest an analytic model to explain the observations. We use galaxies from the Sloan Digital Sky Survey Data Release 7 in the redshift range 0.01⩽z⩽0.2. In estimating L{sub bol}, we employ two different methods using [O III] and/or [O I] emission lines, and find that the L{sub bol} values obtained from the two methods agree well. We consider the M{sub BH}--σ{sub ∗} relation, the M{sub BH}–L {sub bulge} relation, and the single-epoch Hα-based M{sub BH} estimate in calculating M{sub BH}. We find that the trends of the type 1 AGN fraction with respect to M{sub BH} and L{sub bol} are similar for the different methods of deriving L{sub bol} but different when using different methods to derive M{sub BH}. We present a model based on the clumpy-torus scheme that reproduces the ridge-shaped distribution of the fraction parallel to the iso-Eddington ratio lines.

79 ASTRONOMY AND ASTROPHYSICS↗

The Binary Fraction of Stars in the Dwarf Galaxy Ursa Minor via Dark Energy Spectroscopic Instrument

We utilize multi-epoch line-of-sight velocity measurements from the Milky Way Survey of the Dark Energy Spectroscopic Instrument to estimate the binary fraction for member stars in the dwarf spheroidal galaxy Ursa Minor. Our dataset comprises 670 distinct member stars, with a total of more than 2,000 observations collected over approximately one year. We constrain the binary fraction for UMi to be $0.61^{+0.16}_{-0.20}$ and $0.69^{+0.19}_{-0.17}$, with the binary orbital parameter distributions based on solar neighborhood observation from Duquennoy & Mayor (1991) and Moe & Di Stefano (2017), respectively. Furthermore, by dividing our data into two subsamples at the median metallicity, we identify that the binary fraction for the metal-rich ([Fe/H]>-2.14) population is slightly higher than that of the metal-poor ([Fe/H]<-2.14) population. Based on the Moe & Di Stefano model, the best-constrained binary fractions for metal-rich and metal-poor populations in UMi are $0.86^{+0.14}_{-0.24}$ and $0.48^{+0.26}_{-0.19}$, respectively. After a thorough examination, we find that this offset cannot be attributed to sample selection effects. We also divide our data into two subsamples according to their projected radius to the center of UMi, and find that the more centrally concentrated population in a denser environment has a lower binary fraction of $0.33^{+0.30}_{-0.20}$, compared with $1.00^{+0.00}_{-0.32}$ for the subsample in more outskirts.

Qiu, Tian [Shanghai Jiao Tong Univ. (China); DESI ↗

Relationship between cloud radiative forcing, cloud fraction and cloud albedo, and new surface-based approach for determining cloud albedo

This paper focuses on three interconnected topics: (1) quantitative relationship between surface shortwave cloud radiative forcing, cloud fraction, and cloud albedo; (2) surface-based approach for measuring cloud albedo; (3) multiscale (diurnal, annual and inter-annual) variations and covariations of surface shortwave cloud radiative forcing, cloud fraction, and cloud albedo. An analytical expression is first derived to quantify the relationship between cloud radiative forcing, cloud fraction, and cloud albedo. The analytical expression is then used to deduce a new approach for inferring cloud albedo from concurrent surface-based measurements of downwelling surface shortwave radiation and cloud fraction. High-resolution decade-long data on cloud albedos are obtained by use of this surface-based approach over the US Department of Energy's Atmospheric Radiaton Measurement (ARM) Program at the Great Southern Plains (SGP) site. The surface-based cloud albedos are further compared against those derived from the coincident GOES satellite measurements. The three long-term (1997-2009) sets of hourly data on shortwave cloud radiative forcing, cloud fraction and cloud albedo collected over the SGP site are analyzed to explore the multiscale (diurnal, annual and inter-annual) variations and covariations. The analytical formulation is useful for diagnosing deficiencies of cloud-radiation parameterizations in climate models.

54 ENVIRONMENTAL SCIENCES↗

Baryon fraction from the BAO amplitude: a consistent approach to parameterizing perturbation growth

Galaxy clustering constrains the baryon fraction Omega_b/Omega_m through the amplitude of baryon acoustic oscillations and the suppression of perturbations entering the horizon before recombination. This produces a different pre-recombination distribution of baryons and dark matter. After recombination, the gravitational potential responds to both components in proportion to their mass, allowing robust measurement of the baryon fraction. This is independent of new-physics scenarios altering the recombination background (e.g. Early Dark Energy). The accuracy of such measurements does, however, depend on how baryons and CDM are modeled in the power spectrum. Previous template-based splitting relied on approximate transfer functions that neglected part of information. We present a new method that embeds an extra parameter controlling the balance between baryons and dark matter in the growth terms of the perturbation equations in the CAMB Boltzmann solver. This approach captures the baryonic suppression of CDM prior to recombination, avoids inconsistencies, and yields a clean parametrization of the baryon fraction in the linear power spectrum, separating out the simple physics of growth due to the combined matter potential. We implement this framework in an analysis pipeline using Effective Field Theory of Large-Scale Structure with HOD-informed priors and validate it against noiseless LCDM and EDE cosmologies with DESI-like errors. The new scheme achieves comparable precision to previous splitting while reducing systematic biases, providing a more robust way to baryon-fraction measurements. In combination with BBN constraints on the baryon density and Alcock-Paczynski estimates of the matter density, these results strengthen the use of baryon fraction measurements to derive a Hubble constant from energy densities, with future DESI and Euclid data expected to deliver competitive constraints.

Crespi, Andrea [U. Waterloo (main); Waterloo U., I↗