Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE Healthcare), followed by a CT scan for attenuation correction (AC). For each experiment, separate images were created including reconstruction with no corrections (NC), with AC, with attenuation and dual-energy window (DEW) scatter correction (ACSC), with attenuation and partial volume correction (PVC) applied (ACPVC), and with attenuation, scatter, and PVC applied (ACSCPVC). The DEW SC method used was modified to account for the presence of the low-energy tail. Results: T-tests showed that the mean error in absolute activity measurement was reduced significantly for AC and ACSC compared to NC for both (hot and cold) datasets (p < 0.001) and that ACSC, ACPVC, and ACSCPVC show significant reductions in mean differences compared to AC (p ≤ 0.001) without increasing the uncertainty (p > 0.4). The effect of SC and PVC was significant in reducing errors over AC in both datasets (p < 0.001 and p < 0.01, respectively), resulting in a mean error of 5% ± 4%. Conclusions: Quantitative measurements of cardiac {sup 99m}Tc activity are achievable using attenuation and scatter corrections, with the authors’ dedicated cardiac SPECT camera. Partial volume corrections offer improvements in measurement accuracy in AC images and ACSC images with elevated background activity; however, these improvements are not significant in ACSC images with low background activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities

Background: Left ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). Methods and results: After injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/− 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland–Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan. Conclusion: Real-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Independent Confirmatory Survey Summary and Results for the Ford Nuclear Reactor, Ann Arbor, Michigan

At the NRC's request, ORAU conducted confirmatory surveys of the FNR during the period of December 4 through 6, 2012. The survey activities included visual inspections and measurement and sampling activities. Confirmatory activities also included the review and assessment of UM's project documentation and methodologies. Surface scans identified elevated activity in two areas. The first area was on a wall outside of Room 3103 and the second area was in the southwest section on the first floor. The first area was remediated to background levels. However, the second area was due to gamma shine from a neighboring source storage area. A retrospective analysis of UM's FSS data shows that for the SUs investigated by the ORAU survey team, UM met the survey requirements set forth in the FSSP. The total mean surface activity values were directly compared with the mean total surface activity reported by UM. Mean surface activity values determined by UM were within two standard deviations of the mean determined by ORAU. Additionally, all surface activity values were less than the corresponding gross beta DCGLW. Laboratory analysis of the soil showed that COC concentrations were less than the respective DCGLW values. For the inter-lab comparison, the DER was above 3 for only one sample. However, since the sum of fractions for each of the soil samples was below 1, thus none of the samples would fail to meet release guidelines. Based on the findings of the side-by-side direct measurements, and after discussion with the NRC and ORAU, UM decided to use a more appropriate source efficiency in their direct measurement calculations and changed their source efficiency from 0.37 to 0.25.

54 ENVIRONMENTAL SCIENCES↗

Independent Confirmatory Survey Summary and Results for the Ford Nuclear Reactor, Revision 1, Ann Arbor, Michigan

At the NRC's request, ORAU conducted confirmatory surveys of the FNR during the period of December 4 through 6, 2012. The survey activities included visual inspections and measurement and sampling activities. Confirmatory activities also included the review and assessment of UM's project documentation and methodologies. Surface scans identified elevated activity in two areas. The first area was on a wall outside of Room 3103 and the second area was in the southwest section on the first floor. The first area was remediated to background levels. However, the second area was due to gamma shine from a neighboring source storage area. A retrospective analysis of UM's FSS data shows that for the SUs investigated by the ORAU survey team, UM met the survey requirements set forth in the FSSP. The total mean surface activity values were directly compared with the mean total surface activity reported by UM. Mean surface activity values determined by UM were within two standard deviations of the mean determined by ORAU. Additionally, all surface activity values were less than the corresponding gross beta DCGL W . Laboratory analysis of the soil showed that COC concentrations were less than the respective DCGL W values. For the inter-lab comparison, the DER was above 3 for only one sample. However, since the sum of fractions for each of the soil samples was below 1, thus none of the samples would fail to meet release guidelines. Based on the findings of the side-by-side direct measurements, and after discussion with the NRC and ORAU, UM decided to use a more appropriate source efficiency in their direct measurement calculations and changed their source efficiency from 0.37 to 0.25.

54 ENVIRONMENTAL SCIENCES↗

Effect of Silicon in U-10Mo Alloy

This document details a method for evaluating the effect of silicon impurity content on U-10Mo alloys. Silicon concentration in U-10Mo alloys has been shown to impact the following: volume fraction of precipitate phases, effective density of the final alloy, and 235-U enrichment in the gamma-UMo matrix. This report presents a model for calculating these quantities as a function of Silicon concentration, which along with fuel foil characterization data, will serve as a reference for quality control of the U-10Mo final alloy Si content. Additionally, detailed characterization using scanning electron microscope imaging, transmission electron microscope diffraction, and atom probe tomography showed that Silicon impurities present in U-10Mo alloys form a Si-rich precipitate phase.

36 MATERIALS SCIENCE↗

XTE J1908+094

Goddard Space Flight Center reports the serendipitous discovery of a new x-ray transient, XTE J1908+094, in RXTE (Rossi X-ray Timing Explorer) PCA (Proportional Counter Array) observations of the soft-gamma-ray repeater SGR 1900+14, triggered following the burst activity on Feb. 17-18 (GCN 1253). These observations failed to detect the 5.2-s SGR pulsations, pointing towards a possible new source as the origin of the high x-ray flux. An RXTE PCA scan of the region around SGR 1900+14 on Feb. 21 was consistent with emission only from known sources (and no new sources). However, the scans required SGR 1900+14 to be 20 times brighter than its quiescent flux level (GCN 1256). A Director's Discretionary Time Chandra observation on Mar. 11 showed that the SGR was quiescent and did not reveal any new source within the Chandra ACIS (Advanced CCD (charge coupled device) Imaging Spectrometer) field-of-view. A subsequent RXTE PCA scan on Mar. 17, taken in combination with the first scan, required that a new source be included in the fit. The best-fit position is R.A. 19h 08m 50s, Decl. = +9 22 deg .5 (equinox J2000.0; estimated 2 deg systematic error radius), or approximately 24 deg away from the SGR source. The source spectrum (2-30 kev) can be best fit with a power-law function including photoelectric absorption (column density N_h = 2.3 x 10(exp 22), photon index = 1.55). Iron line emission is present, but may be due to the Galactic ridge. Between Feb. 19 and Mar. 17, the source flux (2-10 keV) has risen from 26 to 64 mCrab. The power spectrum is flat between 1 mHz and 0.1 Hz, falling approximately as 1/f**0.5 up to 1 Hz. At 1 Hz is seen a broad quasiperiodic oscillation peak and a break to a 1/f**2 power law, which continues to 4 Hz. The fractional rms (root mean square) amplitude from 1 mHz to 4 Hz is 43 percent. No coherent pulsations are seen between 0.001 and 1024 Hz. The authors conclude that XTE J1908+094 is a new blackhole candidate.

Woods, P. M.↗

Geometric characterization of multi-axis multi-pinhole SPECT

A geometric model and calibration process are developed for single photon emission computed tomography (SPECT) imaging with multiple pinholes and multiple mechanical axes. Unlike the typical situation where pinhole collimators are mounted directly to rotating gamma ray detectors, this geometric model allows for independent rotation of the detectors and pinholes, for the case where the pinhole collimator is physically detached from the detectors. This geometric model is applied to a prototype small animal SPECT device with a total of 22 pinholes and which uses dual clinical SPECT detectors. All free parameters in the model are estimated from a calibration scan of point sources and without the need for a precision point source phantom. For a full calibration of this device, a scan of four point sources with 360 deg. rotation is suitable for estimating all 95 free parameters of the geometric model. After a full calibration, a rapid calibration scan of two point sources with 180 deg. rotation is suitable for estimating the subset of 22 parameters associated with repositioning the collimation device relative to the detectors. The high accuracy of the calibration process is validated experimentally. Residual differences between predicted and measured coordinates are normally distributed with 0.8 mm full width at half maximum and are estimated to contribute 0.12 mm root mean square to the reconstructed spatial resolution. Since this error is small compared to other contributions arising from the pinhole diameter and the detector, the accuracy of the calibration is sufficient for high resolution small animal SPECT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of precipitation behaviors in a non-stoichiometric Cu-24.5at.%Al-19.4at.%Mn alloy

Scanning and transmission electron microscopy examinations of Cu-24.5at.% Al-19.4at.%Mn (similar to Cu{sub 2.2}Mn{sub 0.8}Al) alloy were performed after aging at temperatures ranging from 350 deg. C to 700 deg. C for various durations. It was observed that only {gamma}-brass type and L-J phases were formed after aging at or below 400 deg. C. On the other hand, the {beta}-Mn phase was formed after aging at temperatures ranging from 500 deg. C to 650 deg. C. It is noteworthy that the precipitation behaviors of the {gamma}-brass type and {beta}-Mn phases are different at different aging temperatures. This remarkable result differs from those reported in previous studies on the Cu{sub 3-X}Mn{sub X}Al alloys with X {<=} 1. - Research Highlights: {yields}Precipitation behaviors in a Cu{sub 2.2}Mn{sub 0.8}Al alloy shows different results from those reported in previous studies on the Cu-A-lMn alloys. {yields}The {gamma}-brass type precipitate occurs at temperatures ranging from 350 deg. C to 500 deg. C revealing different precipitation characteristics. {yields}The {beta}-Mn phase formed after aging at 500 deg. C to 650 deg. C shows different precipitation behaviors as well. {yields}L-J phase having an orthorhombic structure could be always observed in the as-quenched and aged conditions.

36 MATERIALS SCIENCE↗

The Dosimetric Effect of Zipper Artifacts on TomoTherapy Adaptive Dose Calculation-A Phantom Study

Tomotherapy adaptive dose calculation offers the ability to verify and adjust the therapeutic plan during the treatment. Using tomotherapy adaptive dose calculation, the planned fluence pattern can be used to recalculate the dose distribution on pretreatment megavoltage computed tomography (MVCT) images. Zipper artifacts, which appear as increased density in the central region of MVCT images, may affect the accuracy of adaptive dose recalculation. The purpose of this study was to evaluate the dosimetric effects of zipper artifacts on tomotherapy adaptive dose calculation. MVCT images of a cylindrical water phantom of 22-cm diameter were acquired on a tomotherapy system. The zipper artifacts were enclosed by a cylindrical planning target volume (PTV) contoured on these images. For comparison, artifact-free images were created by replacing the computed tomography (CT) numbers of zipper artifacts with the mean CT number of water. Treatment plans were generated by giving a uniform dose of 2 Gy to the PTV based on these modified images; it was then applied to the images that have the zipper artifacts. The impacts of different pitch ratios on the artifacts were assessed. The dose distribution differences between the 2 sets of images were compared. The absorbed dose that covered 95% volume of PTV and maximum dose, minimum dose, and mean dose of the PTV were also calculated and compared. The water phantom was scanned on the tomotherapy system twice per week for 12 consecutive weeks. The mean CT number of zipper artifacts (101 HU) was three times higher than that of water (34 HU). The CT number value and location of zipper artifacts were not affected by the pitch ratio. Gamma analysis was performed between the original and recalculated dose distributions. The discrepancies between the isodose distributions calculated by two sets of images were within 1%/1-mm tolerance. The dosimetric impact from zipper artifacts was found insignificant such that the recalculated dose was underestimated by less than 0.5%.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interdiffusion and Formation of Intermetallic Compounds in High-Temperature Power Electronics Substrate Joints Fabricated by Transient Liquid Phase Bonding

Power electronics packages typically comprise a dielectric substrate bonded to a metal layer and attached to heat sinks using a low-thermal-conductivity solder. These multiple layers increase the effective thermal resistance of the package and are responsible for package failures under cyclic thermal loads. Bonding the aluminum nitride dielectric layer (AlN) directly to a low coefficient of thermal expansion (CTE) aluminum silicon carbide (AlSiC) cold plate using copper-aluminum (Cu-Al) transient liquid phase (TLP) bonding has been shown to improve the mechanical reliability of the power electronic packages while making the package more compact by bringing the cooling solutions closer to the devices. This study aims to characterize the Cu-Al bonds formed during the TLP bonding of AlSiC with three different power electronics substrates: pure aluminum nitride (AlN), aluminum (DBA), and copper (DBC). The material compositions and microstructures of the bonds were analyzed using scanning electron microscopy (SEM), x-ray spectroscopy (EDS), confocal scanning acoustic microscopy (C-SAM), and x-ray diffraction (XRD). ..alpha..-Al solid compound was identified as the dominant phase in AlN-AlSiC and Al-AlSiC, with a notable presence of SiC particles. In contrast, three intermetallic phases - ..theta..-CuAl2, ..eta..-CuAl, and ..gamma..'- Cu9Al4 - were observed in the Cu-AlSiC bond. A computational solid-state diffusion model was developed to predict the intermetallic compounds (IMCs) formed during Cu-Al TLP bonding in each system, which supported the observation that an initial Cu volume fraction of 20 % in the material layers produced a final bond composition of >95 % Al with minimal IMC growth. However, increased Cu concentrations produced higher concentration gradients, leading to increased growth of IMCs, Kirkendall voids, and interstitial cracks.

DIRECT ENERGY CONVERSION↗

Synthesis and characterization of molybdenum catalysts supported on {gamma}-Al{sub 2}O{sub 3}-CeO{sub 2} composite oxides

The physical and chemical properties of a catalyst play a vital role in various industrial applications. Molybdenum catalysts supported on {gamma}-Al{sub 2}O{sub 3} and {gamma}-Al{sub 2}O{sub 3}-CeO{sub 2} mixed oxides with varying loading of CeO{sub 2} (5, 10, 15, 20 wt% with respect to {gamma}-Al{sub 2}O{sub 3}) were prepared by wet impregnation method. The physiochemical properties of these synthesized Mo catalysts were studied with various characterization techniques such as X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), temperature-programmed reduction (TPR), field emission scanning electron microscopy-energy dispersive analysis (FESEM-EDX) and X-ray fluorescence spectrometer (XRF). The results showed that the addition of CeO{sub 2} into the support affected the binding energies of the elements and reducibility of the metal oxides formed after calcination of catalyst samples due to the change in metal-support interaction. Further, the characterization techniques showed that the active metal was well dispersed on the surface of support material.

36 MATERIALS SCIENCE↗

Search for Sub-eV Mass Solar Axions by the CERN Axion Solar Telescope with {sup 3}He Buffer Gas

The CERN Axion Solar Telescope (CAST) has extended its search for solar axions by using {sup 3}He as a buffer gas. At T=1.8 K this allows for larger pressure settings and hence sensitivity to higher axion masses than our previous measurements with {sup 4}He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV < or approx. m{sub a} < or approx. 0.64 eV. From the absence of excess x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g{sub a}{gamma} < or approx. 2.3x10{sup -10} GeV{sup -1} at 95% C.L., the exact value depending on the pressure setting. Kim-Shifman-Vainshtein-Zakharov axions are excluded at the upper end of our mass range, the first time ever for any solar axion search. In the future we will extend our search to m{sub a} < or approx. 1.15 eV, comfortably overlapping with cosmological hot dark matter bounds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TPSAS-NF1676L-34417-DND

A boron nitride nanotube (BNNT), an electrically-insulating counterpart of a carbon nanotube (CNT), is a great nanofiller candidate for ferroelectric polymeric nanocomposites due to BNNT?s exceptional properties in piezoelectricity, thermal stability, mechanical strength, and radiation shielding capability. Fast and high-yield polar crystallization of polyvinylidene fluoride (PVDF) was accomplished by incorporating BNNTs as a nucleating agent. As-fabricated BNNT-PVDF nanocomposites were characterized by Fourier-transform infrared spectroscopy (FTIR), wide-angle X-ray diffraction (XRD), and differential scanning calorimetry (DSC) to identify and quantify chain conformations. Besides, piezoelectric constants, d33 of BNNT-PVDF nanocomposites were measured and compared with that of a mechanically drawn beta phase polar PVDF. The polar transformation due to BNNT incorporation has a great advantage over conventional beta or gamma transformation methods that require (1) mechanical drawing often resulting in defects or (2) high-temperature annealing for an extended time. In addition to the fast polar crystallization, BNNTs had a role of reinforcement of the polymer matrix. The improved Young?s modulus and electromechanical coupling coefficient of BNNT-PVDF nanocomposites indicated potential applications in energy harvesting under harsh environments such as large deformation, wide temperature cycles, and high radiation.

Dongwon Lee↗

LENR Products: Lattice Confinement Fusion (LCF), Fission, or Both?

Lattice Confinement Fusion (LCF) or Low Energy Nuclear Reactions (LENR) generate heat from the high energy products they produce. Conventionally, d-d fusion reactions may produce either 2.45 MeV neutrons, 3 MeV protons, or high energy gammas. Generally, fission will give 5-10x the excess energy of fusion. However, aneutronic “cold fusion” would provide 24 MeV/reaction, D(d,γ) 4 He, where the gamma is suppressed. In a series of pressurized gas cycling experiments with a palladium silver (75 wt.% Pd and 25 wt.% Ag or Pd25Ag) alloy [1], samples cycled with deuterium showed excess heat via unexplained temperature rises. Post-test analysis of the Pd25Ag samples using a Scanning Electron Microscope (SEM/EDX) showed several molten features containing anomalous elements other than Pd and Ag. Researchers such as Liu et al [2] have also observed transmutations under similar conditions. These molten areas and anomalous elements suggest Pd fission. This nuclear process has been referred to as nuclear disintegration. Either nuclear fission or disintegration may result in neutron rich fragments. The fragments would rapidly beta decay to shorter lived daughters until they reach stability. We’ve observed evidence of both fusion and fission products [3]. Figure 1 shows neutron spectroscopy showing fusion and boosted neutron energies in bremsstrahlung-initiated fusion of TiD2. Figure 2 shows possible fission products from D 2 gas cycled Pd25Ag alloy. Alternatively, Oppenheimer-Phillips stripping reactions, enhanced by electron screening [4] may also occur. In this case, the 8.6 MeV binding energy per Pd or Ag minus the 2.2 MeV deuteron binding energy leaves 6.4 MeV distributed between the reaction products. The energy is shared inversely proportional to the masses of the stripped off nucleon, p or n, and the new target nucleus.

Theresa L. Benyo↗

LENR Products: Lattice Confinement Fusion (LCF), Fission, or Both?

Lattice Confinement Fusion (LCF) or Low Energy Nuclear Reactions (LENR) generate heat from the high energy products they produce. Conventionally, d-d fusion reactions may produce either 2.45 MeV neutrons, 3 MeV protons, or high energy gammas. Generally, fission will give 5-10x the excess energy of fusion. However, aneutronic “cold fusion” would provide 24 MeV/reaction, D(d,γ) 4 He, where the gamma is suppressed. In a series of pressurized gas cycling experiments with a palladium silver (75 wt.% Pd and 25 wt.% Ag or Pd25Ag) alloy [1], samples cycled with deuterium showed excess heat via unexplained temperature rises. Post-test analysis of the Pd25Ag samples using a Scanning Electron Microscope (SEM/EDX) showed several molten features containing anomalous elements other than Pd and Ag. Researchers such as Liu et al [2] have also observed transmutations under similar conditions. These molten areas and anomalous elements suggest Pd fission. This nuclear process has been referred to as nuclear disintegration. Either nuclear fission or disintegration may result in neutron rich fragments. The fragments would rapidly beta decay to shorter lived daughters until they reach stability. We’ve observed evidence of both fusion and fission products [3]. Figure 1 shows neutron spectroscopy showing fusion and boosted neutron energies in bremsstrahlung-initiated fusion of TiD2. Figure 2 shows possible fission products from D2 gas cycled Pd25Ag alloy. Alternatively, Oppenheimer-Phillips stripping reactions, enhanced by electron screening [4] may also occur. In this case, the 8.6 MeV binding energy per Pd or Ag minus the 2.2 MeV deuteron binding energy leaves 6.4 MeV distributed between the reaction products. The energy is shared inversely proportional to the masses of the stripped off nucleon, p or n, and the new target nucleus.

Theresa L. Benyo↗

A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments

Treatment plans are usually designed, optimized, and evaluated based on the total 3D dose distribution, motivating a total 3D dose verification. The purpose of this study was to develop a 2D transmission-dosimetry method using an electronic portal imaging device (EPID) into a simple 3D method that provides 3D dose information. In the new method, the dose is reconstructed within the patient volume in multiple planes parallel to the EPID for each gantry angle. By summing the 3D dose grids of all beams, the 3D dose distribution for the total treatment fraction is obtained. The algorithm uses patient contours from the planning CT scan but does not include tissue inhomogeneity corrections. The 3D EPID dosimetry method was tested for IMRT fractions of a prostate, a rectum, and a head-and-neck cancer patient. Planned and in vivo-measured dose distributions were within 2% at the dose prescription point. Within the 50% isodose surface of the prescribed dose, at least 97% of points were in agreement, evaluated with a 3D {gamma} method with criteria of 3% of the prescribed dose and 0.3 cm. Full 3D dose reconstruction on a 0.1x0.1x0.1 cm{sup 3} grid and 3D {gamma} evaluation took less than 15 min for one fraction on a standard PC. The method allows in vivo determination of 3D dose-volume parameters that are common in clinical practice. The authors conclude that their EPID dosimetry method is an accurate and fast tool for in vivo dose verification of IMRT plans in 3D. Their approach is independent of the treatment planning system and provides a practical safety net for radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical evaluation of the iterative metal artifact reduction algorithm for CT simulation in radiotherapy

Purpose: To clinically evaluate an iterative metal artifact reduction (IMAR) algorithm prototype in the radiation oncology clinic setting by testing for accuracy in CT number retrieval, relative dosimetric changes in regions affected by artifacts, and improvements in anatomical and shape conspicuity of corrected images. Methods: A phantom with known material inserts was scanned in the presence/absence of metal with different configurations of placement and sizes. The relative change in CT numbers from the reference data (CT with no metal) was analyzed. The CT studies were also used for dosimetric tests where dose distributions from both photon and proton beams were calculated. Dose differences and gamma analysis were calculated to quantify the relative changes between doses calculated on the different CT studies. Data from eight patients (all different treatment sites) were also used to quantify the differences between dose distributions before and after correction with IMAR, with no reference standard. A ranking experiment was also conducted to analyze the relative confidence of physicians delineating anatomy in the near vicinity of the metal implants. Results: IMAR corrected images proved to accurately retrieve CT numbers in the phantom study, independent of metal insert configuration, size of the metal, and acquisition energy. For plastic water, the mean difference between corrected images and reference images was −1.3 HU across all scenarios (N = 37) with a 90% confidence interval of [−2.4, −0.2] HU. While deviations were relatively higher in images with more metal content, IMAR was able to effectively correct the CT numbers independent of the quantity of metal. Residual errors in the CT numbers as well as some induced by the correction algorithm were found in the IMAR corrected images. However, the dose distributions calculated on IMAR corrected images were closer to the reference data in phantom studies. Relative spatial difference in the dose distributions in the regions affected by the metal artifacts was also observed in patient data. However, in absence of a reference ground truth (CT set without metal inserts), these differences should not be interpreted as improvement/deterioration of the accuracy of calculated dose. With limited data presented, it was observed that proton dosimetry was affected more than photons as expected. Physicians were significantly more confident contouring anatomy in the regions affected by artifacts. While site specific preferences were detected, all indicated that they would consistently use IMAR corrected images. Conclusions: IMAR correction algorithm could be readily implemented in an existing clinical workflow upon commercial release. While residual errors still exist in IMAR corrected images, these images present with better overall conspicuity of the patient/phantom geometry and offer more accurate CT numbers for improved local dosimetry. The variety of different scenarios included herein attest to the utility of the evaluated IMAR for a wide range of radiotherapy clinical scenarios.

60 APPLIED LIFE SCIENCES↗

The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗