Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Impeller tandem blade study with grid embedding for local grid refinement

Flow non-uniformity at the discharge of high power density impellers can result in significant unsteady interactions between impeller blades and downstream diffuser vanes. These interactions result in degradation of both performance and pump reliability. The MSFC Pump Technology Team has recognized the importance of resolving this problem and has thus initiated the development and testing of a high head coefficient impeller. One of the primary goals of this program is to improve impeller performance and discharge flow uniformity. The objective of the present work is complimentary. Flow uniformity and performance gains were sought through the application of a tandem blade arrangement. The approach adopted was to numerically establish flow characteristics at the impeller discharge for the baseline MSFC impeller and then parametrically evaluate tandem blade configurations. A tandem design was sought that improves both impeller performance and discharge uniformity. The Navier-Stokes solver AEROVISC was used to conduct the study. Grid embedding is used to resolve local gradients while attempting to minimize model size. Initial results indicate that significant gains in flow uniformity can be achieved through the tandem blade concept and that blade clocking rather than slot location is the primary driver for flow uniformity.

Bache, George↗

A Comparison of Seasonal and Interannual Variability of Soil Dust Aerosols Over the Atlantic Ocean as Inferred by the Toms AI and AVHRR AOT Retrievals

The seasonal cycle and interannual variability of two estimates of soil (or 'mineral') dust aerosols are compared: Advanced Very High Resolution Radiometer (AVHRR) aerosol optical thickness (AOT) and Total Ozone Mapping Spectrometer (TOMS) aerosol index (AI), Both data sets, comprising more than a decade of global, daily images, are commonly used to evaluate aerosol transport models. The present comparison is based upon monthly averages, constructed from daily images of each data set for the period between 1984 and 1990, a period that excludes contamination from volcanic eruptions. The comparison focuses upon the Northern Hemisphere subtropical Atlantic Ocean, where soil dust aerosols make the largest contribution to the aerosol load, and are assumed to dominate the variability of each data set. While each retrieval is sensitive to a different aerosol radiative property - absorption for the TOMS AI versus reflectance for the AVHRR AOT - the seasonal cycles of dust loading implied by each retrieval are consistent, if seasonal variations in the height of the aerosol layer are taken into account when interpreting the TOMS AI. On interannual time scales, the correlation is low at most locations. It is suggested that the poor interannual correlation is at least partly a consequence of data availability. When the monthly averages are constructed using only days common to both data sets, the correlation is substantially increased: this consistency suggests that both TOMS and AVHRR accurately measure the aerosol load in any given scene. However, the two retrievals have only a few days in common per month so that these restricted monthly averages have a large uncertainty. Calculations suggest that at least 7 to 10 daily images are needed to estimate reliably the average dust load during any particular month, a threshold that is rarely satisfied by the AVHRR AOT due to the presence of clouds in the domain. By rebinning each data set onto a coarser grid, the availability of the AVHRR AOT is increased during any particular month, along with its interannual correlation with the TOMS AI The latter easily exceeds the sampling threshold due to its greater ability to infer the aerosol load in the presence of clouds. Whether the TOMS AI should be regarded as a more reliable indicator of interannual variability depends upon the extent of contamination by sub-pixel clouds.

Cakmur, R. V.↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Grid Architecture Mapping to Understand Transformation (GAMUT): Concept Definition

The electric power system is undergoing significant transformation driven by changes in the generation mix, increasing reliance on information and communication technologies, evolving customer expectations, and a dynamic cyber-physical environment. To address these challenges, substantial investments will be made over the next decade to create a flexible, affordable, secure, reliable, and resilient electric system. In response, the U.S. Department of Energy's Office of Electricity is developing knowledge management tools aimed at systematically documenting technology pilots and demonstration projects. This initiative seeks to improve understanding of operating contexts, planning steps, and integration requirements for innovative grid technologies. The Department of Energy project leverages Grid Architecture principles to collect and organize insights into the interdependencies, requirements, and capabilities of various grid solutions. By employing a systematic approach, the project aims to perform a feasibility study for the development of a software tool that will support stakeholders, including regulators, transmission and distribution system operators, distributed energy resources aggregators, and technology providers. By offering a systematic, software-based framework to document technologies, understand their benefits and impacts, and inform deployment strategies, the proposed Grid Architecture Mapping to Understand Transformation (GAMUT) Tool is intended to reduce costs, enhance decision-making, and facilitate scaling and effective deployment of new technologies. The feasibility study will evaluate the technical and financial viability of the GAMUT Tool, identifying stakeholder needs and assessing risks and mitigation strategies. Ultimately, the GAMUT team aims to develop an initial minimal viable product, followed by staged improvements, to aid in the modernization of the electric grid, contributing to a more sustainable and resilient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reimagining Energy Efficiency Resource Standards

Energy Efficiency Resource Standards (EERS) are a long-standing policy used to advance state goals and priorities, such as reliability, affordability and decarbonization. They ensure cost-effective energy efficiency is used to lower energy consumption, reduce peak demand, and enable grid flexibility. Adapting EERS through strategic design, and integrating EERS into broader energy plans and policies, can help states optimize their approach to meet modern and evolving power system needs and achieve sustainable energy outcomes. This report examines how states consider energy efficiency in the context of four policy priorities: providing grid benefits, addressing load growth, reducing emissions, and promoting affordability. It provides examples of states that are pursuing these priorities, reviews the role of energy efficiency in them and identifies opportunities to further promote energy efficiency alongside the priorities. Decisionmakers and stakeholders can draw directly from these examples and findings to design an EERS that maximizes co-benefits, captures synergies, and promotes consideration of the all the possible solutions to advance their goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The 200-kilowatt wind turbine project

The three 200 kilowatt wind turbines described, compose the first of three separate systems. Proposed wind turbines of the two other systems, although similar in design, are larger in both physical size and rated power generation. The overall objective of the project is to obtain early operation and performance data while gaining initial experience in the operation of large, horizontal-axis wind turbines in typical utility environments. Several of the key issues addressed include the following: (1) impact of the variable power output (due to varying wind speeds) on the utility grid (2) compatibility with utility requirements (voltage and frequency control of generated power) (3) demonstration of unattended, fail-safe operation (4) reliability of the wind turbine system (5) required maintenance and (6) initial public reaction and acceptance.

Source record↗

Role of PHM in Autonomous Decision-Making: Aerospace applications

There is an increased need for onboard decision-making capabilities in cyber-physical systems be it in energy, automotive, aviation, space, or other industries as they aim for increased efficiency, resiliency, and mission assurance capabilities. Emerging next-gen technologies such as multi-rover planetary missions, distributed satellites, unmanned ground and aerial vehicle operations and smart grid systems rely on in-time risk assessment and autonomous decision-making. One critical piece of the autonomy puzzle is reliable prediction of system behavior under time-varying and potentially uncertain environmental conditions. Further, if agent states change during operation such as initiation of faults or degradation, reliable diagnostic tools need to be investigated. In this tutorial, we will revise approaches that integrates existing physics-based and data-driven models of agents interacting with probability models of the environment and component operation state. Role of existing PHM methodologies as they feed into decision-making under uncertainty will be studied. Balancing critical trade-offs between high-fidelity prognostic models, prediction time-horizons and the computational requirements for in-time cost-effective decision-making will be discussed through the implementation of surrogate models. Finally, the audience will be introduced to a real-time application of in-time trajectory planning of an unmanned aerial system (UAS) based on its PHM assessments under uncertain and varying wind conditions.

decision-making↗

A Machine Learning Approach for Hourly Traffic Prediction Used in EV-Charging Sites

Reliable forecasting of hourly traffic volumes on highways is critical for planning and operating electric-vehicle charging infrastructure without overloading the grid. In this work, we develop and evaluate a station-specific machine-learning approach based on NeuralProphet, enhanced with conditional seasonality to better distinguish weekday, weekend, and holiday patterns. For each station, the model automatically retrieves the same calendar day from the prior years as an AR-Net initialization, fits trend and Fourier-based seasonality components, and then applies short-term auto-regressive corrections. We train and test on 2021 and 2022 TMAS data, respectively, and validate performance over the whole year. We chose to demonstrate how the model performs on a typical weekday (3/15/2022), weekend (3/27/2022), and a special holiday (12/25/2022). Our results yield MAPE of 7.4%, 23.6%, and 32.0%, respectively. Over the entire year 2022, the overall MAPE was 17%. This demonstrates that station-specific models with conditional seasonality can achieve accurate, scalable hourly forecasts for EV-charging load planning.

99 - GENERAL AND MISCELLANEOUS↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

A Hardware-in-the-Loop Experimental Testbed Using Air Conditioners for Grid Balancing

Driven by the need to offset the variability of renewable generation on the grid, development of load control is a highly active field of research. However, practical use of residential loads for grid balancing remains rare, in part due to the cost of communicating with large numbers of small loads and also the limited experimentation done so far to demonstrate reliable operation. To establish a basis for the safe and reliable use of fleets of compressor loads as distributed energy resources, we constructed an experimental testbed in a laboratory, so that load coordination schemes could be tested at extreme conditions. Here, this experimental testbed was used to tune a simulation testbed to which it was then linked, thereby augmenting the effective size of the fleet. Modeling of the system was done both to demonstrate the experimental testbed's behavior and also to understand how to tune the behavior of each load. Implementing this testbed has enabled rapid turnaround of experiments on various load control algorithms, and year-round testing without the constraints and limitations arising in seasonal field tests with real houses. Experimental results show the practical feasibility of an ensemble of small loads contributing to grid balancing.

Air Conditioners↗

Assessment of NuScale SMR Steam Heat Augmentation for Chemical Plant Decarbonization

Nearly 50% of the total energy consumed by the industrial sector in the United States is used to produce process steam with natural gas and coal-fired boilers1 . This project conducts a technoeconomic assessment of a NuScale Small Modular Reactor (SMR) coupled with a chemical plant as an Integrated Energy System (IES) where nuclear produces steam and electric power to meet the requirements of a large chemical plant. In a 2020 study, ORNL evaluated the feasibility of using advanced SMRs, including the NuScale design, to supply energy to the Eastman Chemical Plant. However, since that report was published, NuScale received NRC approval for its uprated 77 MWe design with 56% more power and has also introduced a high-temperature, high pressure, steam heat-augmentation system, a key focus of the new study. The new study also benefits from revised capital costs, a 10-day refueling outage time, reduced plant staffing, higher capacity factors, and a site boundary Emergency Planning Zone methodology. The study consists of a techno-economic assessment of two possible energy sources (nuclear and natural gas) in a number of steam and power generation configurations (NuScale Power Modules (NPMs), boilers and combinations of both) to satisfy the steam and power demand with the most reliable and cost competitive system. A total of 2,947.3 klb/hr of steam and 72.5 MWe of electricity are required for the demonstration case. A range of scenarios and solutions are explored, from a 12-NPM plant (3,000 MWth)—with excess capacity and redundancy, capable of supplying a significant amount of extra power to the grid—to a 4-NPM (1,000 MWth) plant—supplemented with existing boilers or grid power for redundancy. The study uses historical steam and power data from a chemical plant and examines the sensitivity to natural gas and grid power cost variations. Scenarios with up to two times gas and electricity costs were considered. Profitability in a 60-year time horizon was analyzed, consistent with NuScale’s design life specification. A steady-state site integration and reliability analysis was performed, and trade-offs were identified.

20 FOSSIL-FUELED POWER PLANTS↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Environmental Evaluation of Gas Switching Reforming for Low Carbon Hydrogen: A Power-to-X Study

Gas Switching Reforming for hydrogen production (GSR-H2) offers a promising pathway for producing low-carbon hydrogen at scale, with significant implications for Power-to-X (PtX) systems that rely on clean hydrogen as a feedstock for synthetic fuels and chemicals. GSR-H2 integrates inherent carbon capture and thermal self-sufficiency, positioning it as an efficient alternative to conventional steam methane reforming (SMR), proton exchange membrane (PEM) electrolysis, and chemical looping reforming (CLR). Unlike SMR, GSR-H2 avoids external natural gas combustion by leveraging exothermic redox cycles to generate process steam and recover electricity internally. Its innovative reactor design consolidates all reforming stages within a single reactor cluster, eliminating the need for solid circulation found in CLR, thereby reducing capital costs and improving system reliability and scalability. This presentation describes the first environmental life cycle assessment (LCA) of GSR-H2, evaluating its environmental performance across U.S. grid and renewable energy scenarios. In a renewables-powered configuration, GSR-H2 achieves a global warming potential (GWP) of 2.77 kg CO2 equivalent per kg H2, substantially lower than SMR (10.4 kg) and competitive with PEM electrolysis (1.85 kg) and CLR (1.84 kg). Results across additional impact categories, including air quality and water use, support GSR-H2’s role as a complementary hydrogen source in PtX applications. Its reduced environmental burden, thermal integration, and simplified scale-up potential make GSR-H2 a viable contributor to net-zero PtX systems, particularly where renewable energy is abundant and electricity-intensive hydrogen production faces economic or infrastructure constraints.

03 NATURAL GAS↗