Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators

For many aspheric and freeform optical components, existing interferometric solutions require a custom computer-generated hologram (CGH) to characterize the part. The overall objective of this research is to develop hardware and a procedure to produce a combined, dynamic, Hartmann/ Digital Holographic interferometry inspection system for a wide range of advanced optical components, including aspheric and freeform optics. This new instrument would have greater versatility and dynamic range than currently available measurement systems. The method uses a spatial light modulator to pre-condition wavefronts for imaging, interferometry, and data processing to improve the resolution and versatility of an optical inspection instrument. Existing interferometers and Hartmann inspection systems have either too small a dynamic range or insufficient resolution to characterize conveniently unusual optical surfaces like aspherical and freeform optics. For interferometers, a specially produced, computer-generated holographic optical element is needed to transform the wavefront to within the range of the interferometer. A new hybrid wavefront sensor employs newly available spatial light modulators (SLMs) as programmable holographic optical elements (HOEs). The HOE is programmed to enable the same instrument to inspect an optical element in stages, first by a Hartmann measurement, which has a very large dynamic range but less resolution. The first measurement provides the information required to precondition a reference wave that avails the measurement process to the more precise phase shifting interferometry. The SLM preconditions a wavefront before it is used to inspect an optical component. This adds important features to an optical inspection system, enabling not just wavefront conditioning for null testing and dynamic range extension, but also the creation of hybrid measurement procedures. This, for example, allows the combination of dynamic digital holography and Hartmann sensing procedures to cover a virtually unlimited dynamic range with high resolution. Digital holography technology brings all of the power and benefits of digital holographic interferometry to the requirement, while Hartmann-type wavefront sensors bring deflectometry technologies to the solution. The SLM can be used to generate arbitrary wavefronts in one leg of the interferometer, thereby greatly simplifying its use and extending its range. The SLM can also be used to modify the system into a dynamic Shack-Hartmann system, which is useful for optical components with large amounts of slope. By integrating these capabilities into a single instrument, the system will have tremendous flexibility to measure a variety of optical shapes accurately.

Trolinger, James↗

Primary Objective Grating Astronomical Telescope

It has been 370 years since a seventeenth century French mathematician, Mersenne, presciently sketched out an astronomical telescope based on dual parabolic reflectors. Since that time the concept of the primary objective has been virtually unchanged. Now a new class of astronomical telescope with a primary objective grating (POG) has been studied as an alternative. The POG competes with mirrors, in part, because diffraction gratings provide the very chromatic dispersion that mirrors defeat. The resulting telescope deals effectively with long-standing restrictions on multiple object spectroscopy (MOS). Other potential benefits include unprecedented apertures and collection areas. The new design also favors space deployment as a gossamer membrane. The inventor, Tom Ditto, first discovered that higher-order diffraction images contain hidden depth cues, for which he was granted a seminal range finding patent in 1987. Subsequently, he invented and patented 3D localizers, profilometers and microscopes using POGs. The POG telescope was placed in the public domain to expedite research. The function of a telescopes primary objective is to collect flux and to deliver images. Both functions dictate that size matters, and bigger is better. For that reason, there has been a steady push over the past century to ramp up the size of the primary mirror. However, for every doubling of mirror diameter, the elapsed time between initial effort and first light has also doubled. Meanwhile, costs escalated beyond the mirror alone, because larger instruments required larger enclosures and better pointing mechanisms. One key catalog of observation, spectrographic data, is far more difficult to amass than two-dimensional imagery. While the number of observable objects has increased with mirror size, the capacity to take spectra has not increased proportionately. In the best of circumstances, spectrograms are available for one per cent of the all objects surveyed. Spectroscopy was a historical afterthought introduced in the nineteenth century shortly after the invention of the diffraction grating and over a century after Newtons 1670 telescope. Spectroscopy is generally accomplished using a diffraction grating as the disperser in the secondary. The light being delivered to the spectrograph is first captured by a primary mirror which provides no chromatic magnification by itself. Sizeable spectrographs could not be deployed while diffraction gratings were rare commodities scribed using mechanical ruling engines that produced one grating line at a time. Today diffraction gratings are commonplace. Their recent availability is a product of both the invention of holography and the mass replication of surface microstructures. Holography permits all lines in a grating to be made simultaneously in a single photographic exposure. Holograms can then be reproduced by embossing processes. The improvement in replication is analogous to how Gutenberg changed the availability of books. The masters may be expensive, but the copies are not. Computer science is another technology that emerged in the second half of the twentieth century without which our proposed spectrographic instrument could not function due to the complexity of image processing required in data reduction. The employment of very large diffraction gratings as primary objectives for astronomical telescopes requires a novel

spectroscopy↗

A multiwavelength digital holographic microscope architecture for enhancing life detection

Spectral properties of living organism can provide a discriminating method for characterization. However, digital holographic microscopy (DHM), a high-resolution, volumetric imaging technique that is well-suited for examining microbial species is typically monochromatic. Thus, the spectral properties of bacteria are not probed with DHM save only for the wavelength of operation. Here we describe a new DHM instrument which enhances the method via the simultaneous recording of wavelength multiplexed holograms of the sample. This coarse spectral encoding is akin to labeling with RGB values, thereby producing colorized images of the species which enables a new dimension of characterization. This new instrument is derived from a previous architecture which has already demonstrated superior opto/mechanical stability. Herein, this novel instrument is described, and the results of experimental measurements taken with this new instrument are shown.

Bedrossian, Manuel↗

DHMx (Digital Holographic Microscope Experience) Software Tool

The DHMx (Digital Holographic Microscope Experience) is an open-source software suite designed to perform reconstructions from off-axis holograms obtained from either a real-time stream or from disk with a graphical interface for commanding and display

Fregoso, S. Felipe↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r 0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

Folded Optical Design for High Fidelity Atmospheric Emulation With A Spatial Light Modulator

Atmospheric emulators based on spatial light modulators offer the ability to test atmospheric propagation effects on a laser communication component’s performance in the laboratory setting. To create a high-fidelity atmospheric emulator, details of the optical design are key. This paper discusses the optical design choices and refinements that enabled the creation of a system that was verified to recreate multi-layer turbulence with high fidelity up to D/r0 =50. Optical design choices that affect the fidelity discussed in this paper include the characteristics of the input laser, the spatial light modulator, the holograms, the image relay optical components, and the spatial filter. Also included in this paper is a comparison of the chosen folded optical layout to an alternative angled layout.

Atmospheric turbulence↗

The PCM is Dead! Long Live O-PCM!

The ability to reconfigure the optical behavior of a device enables free-space applications ranging from imaging to sensing and signal control. Such optical devices can be compacted via meta-surfaces, patterned structures with feature sizes below the incident wavelength. Leveraging geometry in addition to material properties and CMOS fabrication techniques has allowed meta-surfaces for lenses, holograms, beam steerers and more. To incorporate multiple optical functions into one device, various methods of device control have been implemented, such as stretching of flexible substrates, tuning the refractive index of the comprising meta-atoms via the electro-optic or the thermo-optic effects, phase transition materials such as VO2 and more. Chalcogenide glasses used as optical phase change materials, such as Ge¬2Sb2Te5 (GST), have gained increased traction in the optics community for potential use in the near infrared (NIR) and mid infrared (MIR) bands, including the telecom bands. Various chalcogenides such as Sb2Se3, Sb2S3, Ge2Sb¬2Se5 and Ge2Sb2Se4Te (GSST) have been investigated due to their broad NIR or MIR transparency window and large changes in refractive index. In their amorphous phase, these materials usually display a lower refractive index and low absorption when compared to their crystalline state which display a higher refractive index and typically larger extinction coefficients. The amorphous-crystalline reversible switching can be done via fast melt-quenching thermal processes triggered by laser or electrical impulses, relying on a substrate as a heat sink. The potential of PCMs in photonic devices can be limited by intrinsic material limitations as well as by device fabrication issues. To explore the cyclability of GSST, a PCM with large refractive index contrast and on-chip electrothermal switching on a silicon-on-insulator platform has been done to analyze potential failure mechanisms from both a material and device perspective. A brief outline of the instrumentation and phase change contrast analysis is provided. Dewetting of the PCM, delamination of and damage in the PECVD SiNx protective layer, elemental migration in the PCM and optical contrast decay have been observed in cycled GSST devices. Guidelines for device performance improvement are proposed, and an improved design with larger endurance is shown in progress.

reconfigurable photonics↗

The Electron Ronchigram

The electron Ronchigram is a form of inline hologram that offers a convenient way to directly see and measure electron optical aberrations. Any user of an aberration-corrected STEM is likely to benefit from a basic understanding of how such an image is formed and used. This chapter will review the formation of the electron Ronchigram with a particular emphasis on the effects and measurement of aberrations. This review will be largely based on our own approach and previously published work.

47 OTHER INSTRUMENTATION↗

High resolution projection micro stereolithography system and method

A high-resolution P.mu.SL system and method incorporating one or more of the following features with a standard P.mu.SL system using a SLM projected digital image to form components in a stereolithographic bath: a far-field superlens for producing sub-diffraction-limited features, multiple spatial light modulators (SLM) to generate spatially-controlled three-dimensional interference holograms with nanoscale features, and the integration of microfluidic components into the resin bath of a P.mu.SL system to fabricate microstructures of different materials.

36 MATERIALS SCIENCE↗

Dual laser holography for in situ measurement of plasma facing component erosion (invited)

A digital holography (DH) surface erosion/deposition diagnostic is being developed for 3D imaging of plasma facing component surfaces in situ and in real time. Digital holography is a technique that utilizes lasers reflected from a material surface to form an interferogram, which carries information about the topology of the surface when reconstructed. As described, dual CO 2 lasers at 9.271 and 9.250 μm wavelengths illuminate the interrogated surface (at a distance of ~1 m) in a region of ~1 cm × 1 cm. The surface feature resolution is ~0.1 mm in the plane of the surface, and the depth resolution ranges from ~0.0001 to ~2 mm perpendicular to the surface. The depth resolution lower limit is set by single-laser and detector optical limitations, while the upper limit is determined by 2π phase ambiguity of the dual-laser synthetic wavelength. Measurements have been made “on the bench” to characterize the single-laser and dual-laser DH configurations utilizing standard resolution targets and material targets that were previously exposed to high flux plasmas in either the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) or the electro-thermal (ET) arc source. Typical DH measurements were made with 0.03 ms integration with an IR camera that can be framed at rates approaching 1.5 kHz. Finally, the DH diagnostic system is progressing toward in situ measurements of plasma erosion/deposition either on Proto-MPEX or the ET arc source.

47 OTHER INSTRUMENTATION↗

Multiple Methods of Determining the Gravity-Sag of Light-Weighted Optics

Characterizing Gravity-sag (G-sag) is an essential part of developing a large space-based optic. A method to back out gravity sag of a light-weighted optic using a CGH will be demonstrated. The results from the G-sag CGH determination is compared to the G-sag and Zero-G figure obtained during horizontal G-sag testing. The results from the CGH testing are also compared to the G-sag figure determined from modeling.