Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Experimental system for the control of surgically induced infections

The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

Source record↗

Cloud object store for archive storage of high performance computing data using decoupling middleware

Cloud object storage is enabled for archived data, such as checkpoints and results, of high performance computing applications using a middleware process. A plurality of archived files, such as checkpoint files and results, generated by a plurality of processes in a parallel computing system are stored by obtaining the plurality of archived files from the parallel computing system; converting the plurality of archived files to objects using a log structured file system middleware process; and providing the objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

97 MATHEMATICS AND COMPUTING↗

Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding and Analyzing Interconnect Errors and Network Congestion on a Large Scale HPC System

Today's High Performance Computing (HPC) systems are capable of delivering performance in the order of petaflops due to the fast computing devices, network interconnect, and back-end storage systems. In particular, interconnect resilience and congestion resolution methods have a major impact on the overall interconnect and application performance. This is especially true for scientific applications running multiple processes on different compute nodes as they rely on fast network messages to communicate and synchronize frequently. Unfortunately, the HPC community lacks state-of-practice experience reports that detail how different interconnect errors and congestion events occur on large-scale HPC systems. Therefore, in this paper, we process and analyze interconnect data of the Titan supercomputer to develop a thorough understanding of interconnects faults, errors and congestion events. We also study the interaction between interconnect, errors, network congestion and application characteristics.

Kumar, Mohit↗

zPerf: A Statistical Gray-Box Approach to Performance Modeling and Extrapolation for Scientific Lossy Compression

With the scaling up of simulation-based scientific discovery on high-performance computing systems, the disparity between compute and I/O has increased, forcing domain scientists to save only a small amount of simulation data to persistent storage. This can result in the loss of essential physics fields that are needed for data analysis. While error-bounded lossy compression has made tremendous progress in bridging the gap between compute and I/O, the lack of understanding of compression performance remains a key hurdle to its wide adoption. Here, in this work, we present zPerf, a statistical gray-box performance modeling approach for scientific lossy compression. Our contributions are threefold: 1) We develop zPerf to estimate the performance of lossy compression techniques, based on in-depth understanding and statistical modeling for data features and core compression metrics; 2) We demonstrate the in-detailed implementation of zPerf using two case studies, where we derive the performance modeling for SZ and ZFP, two leading lossy compressors; 3) We evaluate the effectiveness of zPerf on real-world datasets across various domains. Based on the evaluation, we demonstrate the efficacy of the zPerf performance model; 4) We further discuss three case studies where zPerf is applied to extrapolate the compression ratio of SZ and ZFP with alternative encoding schemes as well as ZFP with an alternative transform scheme. Through the case studies, we demonstrate the potential of zPerf for exploring the design space of lossy compression, which has hardly been studied in the literature.

97 MATHEMATICS AND COMPUTING↗

Liquefaction and Storage of In-Situ Oxygen on the Surface of Mars

The In-Situ production of propellants for Martian and Lunar missions has been heavily discussed since the mid 1990's. One portion of the production of the propellants is the liquefaction, storage, and delivery of the propellants to the stage tanks. Two key technology development efforts are required: large refrigeration systems (cryocoolers) to perform the liquefaction and high performance insulation within a soft vacuum environment. Several different concepts of operation may be employed to liquefy the propellants based on how and where these two technologies are implemented. The concepts that were investigated include: using an accumulator tank to store the propellant until it is needed, liquefying in the flow stream going into the tank, and liquefying in the flight propellant tank itself. The different concept of operations were studied to assess the mass and power impacts of each concept. Additionally, the trade between insulation performance and cryocooler mass was performed to give performance targets for soft vacuum insulation development. It was found that liquefying within the flight propellant tank itself adds the least mass and power requirements to the mission.

Cryogenic Fluid Management↗

Register-Like Block RAM with Boundary Coverage and Its Applications for High Energy Physics Trigger Systems

In high energy physics experiment trigger systems, block memories are utilized for various purposes, especially in binned searching algorithms. In these algorithms, the storages are demanded to perform like a large set of registers. The writing and reading operation must be performed in single clock cycle and once an event is processed, the memory must be globally reset. These demands can be fulfilled with registers but the cost of using registers for large memory is unaffordable. Another common requirement is the boundary coverage feature during reading process. When a memory bin is addressed, the stored contents in the addressed bin and its neighboring bin must be output simultaneously. In this paper, a register-like block memory design scheme is described, which allows updating memory locations in single clock cycle, reading two adjacent bins and effectively refreshing entire memory within a single clock. The implementation and test results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimizing high energy density sulfur cathodes: A multivariate approach to electrode formulation and processing

Lithium-sulfur (Li-S) batteries involve complex solid-liquid-solid phase transformations during both discharging and charging processes, where cathode materials, formulation, and structure play a crucial role. Here, a design of experiments (DoE) methodology and an empirical model are developed to systematically explore the interactions and trade-offs among cathode factors and process variables, and to obtain generalizable effects estimates for the multivariate system. Compared to the conventional one-factor-at-a-time (OFAT) approach, this work demonstrates advantages in both efficiency and accuracy by allowing the data to guide future research and decisions. Further, an optimized cathode formulation and processing parameters are predicted and validated experimentally, achieving over 1000 mAh g -1 in discharge capacity and improved cycling under practical lean electrolyte (4 µL mg -1 S) and high S-loading cathodes (>4 mg cm -2 ) conditions. The optimized cathode was scaled up and assembled into Li-S pouch cells, achieving 316 Wh kg -1 in cell-level energy, proving that the comprehensive and rigorous framework for optimizing complex systems with DoE leads to improved performance in a practical pouch cell system.

25 ENERGY STORAGE↗

Room temperature thermal conductivity measurements of neat MOF-5 compacts with high pressure hydrogen and helium

Metal-organic frameworks (MOFs) are a highly porous crystalline material with potential in various applications including on-board vehicle hydrogen storage for fuel cell vehicles. The thermal conductivity of MOFs is an important parameter in the design and ultimate performance of an on-board hydrogen storage system. However, in-situ thermal conductivity measurements have not been previously reported. The present study reports room temperature thermal conductivity and thermal diffusivity measurements performed on neat MOF-5 cylindrical compacts (ρ = 0.4 g/mL) as a function of pressure (0.27–90 bar) and gas type (hydrogen and helium). The transient plane source technique was used to measure both the non-directional thermal properties (isotropic method) and the directional thermal properties (anisotropic method). High pressure measurements were made using our in-house built low-temperature, high pressure thermal conductivity sample cell. The intrinsic thermal properties of neat MOF-5 measured under vacuum were—Isotropic: k isotropic = 0.1319 W/m K, α isotropic = 0.4165 mm 2 /s; Anisotropic: k axial = 0.1477 W/m K, k radial = 0.1218 W/m K, α axial = 0.5096 mm 2 /s, and α radial = 0.4232 mm 2 /s. The apparent thermal properties of neat MOF-5 increased with increasing hydrogen and helium pressure, with the largest increase occurring in the narrow pressure range of 0–10 bar and then monotonically asymptoting with increasing pressures up to around 90 bar. On average, a greater than two-fold enhancement in the apparent thermal properties was observed with neat MOF-5 in the presence of helium and hydrogen compared to the intrinsic values of neat MOF-5 measured under vacuum. The apparent thermal properties of neat MOF-5 measured with hydrogen were higher than those measured with helium, which were directly related to the gas-specific thermal properties of helium and hydrogen. Neat MOF-5 exhibited a small degree of anisotropy under all conditions measured with thermal conductivities and diffusivities in the axial direction being higher than those in the radial direction. As a result, the low temperature specific heat capacities of neat MOF-5 were also measured and reported for the temperature range of 93–313 K (–180–40 °C).

36 MATERIALS SCIENCE↗

Water-lubricated intercalation in V2O5·nH2O for high-capacity and high-rate aqueous rechargeable zinc batteries

Co-intercalation is an effective approach to tune the diffusion coefficient with which cations insert into the electrodes for energy storage devices. By applying this concept in aqueous Zn batteries, a prospective system for stationary energy storage, we demonstrate the critical role of structural H2O on Zn2+ intercalation into bilayer V2O5·nH2O. The H2O solvation of Zn2+ largely reduces its effective charge and thus electrostatic interaction with the V2O5 framework, evidently promoting the diffusion of solvated Zn2+. Benefited from the ‘lubricating’ effect, the aqueous Zn battery shows a specific energy of ~ 305 Wh kg-1 (based on cathode), comparable to those of LiCoO2//Graphite batteries. Meanwhile, it can maintain an energy density of 199 Wh kg-1 at a high power density of 24 kW kg-1 with a capacity retention of 88% after 900 cycles, making it a promising candidate for high-performance, low-cost, safe and environmentally friendly energy storage device.

Yan, Mengyu↗

Energy Storage for Lunar Surface Exploration

This paper presents the updated results of a previous NASA study funded under the Advanced Exploration Systems (AES) Modular Power Systems (AMPS) project. This work focuses on generating high-level system sizing relationships for two lunar surface locations that serve as bounding conditions for most other locations. Four critical parameters are considered to provide sizing data: specific energy, energy density, specific power, and power density. Given the energy storage requirements or customer power demand for a lunar mission location, the data presented in this paper provides a method to determine the critical parameter values of a Regenerative Fuel Cell (RFC) system in order to perform high-level mission architecture trades.

surface power systems↗

Underwater characterization of control rods for waste disposal using SMOPY

Storage of spent fuel assemblies in cooling ponds requires careful control of the geometry and proximity of adjacent assemblies. Measurement of the fuel burnup makes it possible to optimise the storage arrangement of assemblies taking into account the effect of the burnup on the criticality safety margins ('burnup credit'). Canberra has developed a measurement system for underwater measurement of spent fuel assemblies. This system, known as 'SMOPY', performs burnup measurements based on gamma spectroscopy (collimated CZT detector) and neutron counting (fission chamber). The SMOPY system offers a robust and waterproof detection system as well as the needed capability of performing radiometric measurements in the harsh high dose - rate environments of the cooling ponds. The gamma spectroscopy functionality allows powerful characterization measurements to be performed, in addition to burnup measurement. Canberra has recently performed waste characterisation measurements at a Nuclear Power Plant. Waste activity assessment is important to control costs and risks of shipment and storage, to ensure that the activity level remains in the range allowed by the facility, and to declare activity data to authorities. This paper describes the methodology used for the SMOPY measurements and some preliminary results of a radiological characterisation of AIC control rods. After describing the features and normal operation of the SMOPY system, we describe the approach used for establishing an optimum control rod geometric scanning approach (optimum count time and speed) and the method of the gamma spectrometry measurements as well as neutron check measurements used to verify the absence of neutron sources in the waste. We discuss the results obtained including {sup 60}Co, {sup 110m}Ag and {sup 108m}Ag activity profiles (along the length of the control rods) and neutron results including Total Measurement Uncertainty evaluations. Full self-consistency checks were performed and these demonstrate the validity of the techniques. The results are described and analysed in the context of the measurement performance of the equipment. Different casks were fully characterized using a 60 mm{sup 3} CZT detector, to determine the total activities and spatial profiles. A total activity range measurement of 1x10{sup 8} - 1x10{sup 13} Bq/cm was found to be achievable. Finally, comments are made, based on our measurements, on the ability of this equipment for performing in-situ characterisation of wastes in the harsh environments typical of fuel assembly and waste storage ponds and silos. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Storage Performance of Preferentially Oriented Mg/rGO Hybrids

Chemical interactions on the surface of a functional nanoparticle are closely related to its crystal facets, which can regulate the corresponding energy storage properties like hydrogen absorption. In this study, we reported a one-step growth of magnesium (Mg) particles with both close- and nonclose-packed facets, that is, {0001} and {$2\overline{116}$} planes, on atomically thin reduced graphene oxide (rGO). The detailed microstructures of Mg/rGO hybrids were revealed by X-ray diffraction, selected-area electron diffraction, high-resolution transmission electron microscopy, and fast Fourier transform analysis. Hydrogen storage performance of Mg/rGO hybrids with different orientations varies: Mg with preferential high-index {$2\overline{116}$} crystal surface shows remarkably increased hydrogen absorption up to 6.2 wt % compared with the system exposing no preferentially oriented crystal surfaces showing inferior performance of 5.1 wt % within the first 2 h. First-principles calculations revealed improved hydrogen sorption properties on the {$2\overline{116}$} surface with a lower hydrogen dissociation energy barrier and higher stability of hydrogen atoms than those on the {0001} basal plane, supporting the hydrogen uptake experiment. In addition, the hydrogen penetration energy barrier is found to be much lower than that of {0001} because of low surface atom packing density, which might be the most critical process to the hydrogenation kinetics. Here, the experimental and calculation results present a new handle for regulating the hydrogen storage of metal hydrides by controlled Mg facets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On-Board Chemical Propulsion Technology

On-board propulsion functions include orbit insertion, orbit maintenance, constellation maintenance, precision positioning, in-space maneuvering, de-orbiting, vehicle reaction control, planetary retro, and planetary descent/ascent. This paper discusses on-board chemical propulsion technology, including bipropellants, monopropellants, and micropropulsion. Bipropellant propulsion has focused on maximizing the performance of Earth storable propellants by using high-temperature, oxidation-resistant chamber materials. The performance of bipropellant systems can be increased further, by operating at elevated chamber pressures and/or using higher energy oxidizers. Both options present system level difficulties for spacecraft, however. Monopropellant research has focused on mixtures composed of an aqueous solution of hydroxl ammonium nitrate (HAN) and a fuel component. HAN-based monopropellants, unlike hydrazine, do not present a vapor hazard and do not require extraordinary procedures for storage, handling, and disposal. HAN-based monopropellants generically have higher densities and lower freezing points than the state-of-art hydrazine and can higher performance, depending on the formulation. High-performance HAN-based monopropellants, however, have aggressive, high-temperature combustion environments and require advances in catalyst materials or suitable non-catalytic ignition options. The objective of the micropropulsion technology area is to develop low-cost, high-utility propulsion systems for the range of miniature spacecraft and precision propulsion applications.

Reed, Brian D.↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

Development & Experimental Validation of a Generalized Resistance-Capacitance Model for Numerical Simulation of Phase-Change Material Embedded Heat Exchangers

Latent heat thermal energy storage (LHTES) using phase change material (PCM) has attracted increased attention as a viable solution for overcoming the mismatch between energy supply and demand for renewable energy-based systems. PCM-embedded heat exchangers (PCM-HX) have the potential to significantly improve thermal performance due to high storage capacity and low temperature variation during the phase change process. Most models for simulating LHTES heat transfer use Computational Fluid Dynamics (CFD) simulations, which have high computational costs resulting from considering the complex and time-dependent physics relevant to PCM-HXs. In this paper, a Generalized Resistance Capacitance-based Model (GRCM) was developed to predict the thermal performance of arbitrary PCM-HXs in a computationally efficient manner without compromising modeling accuracy. The GRCM is exercised for three case studies: (i) verification for a single-slabbed finned PCM-HX, (ii) verification and validation for a copper foam/paraffin composite PCM-HX, and (iii) validation for a straight tube annular finned PCM-HX. The copper foam PCM-HX uses an electric heater at the top of HX, while the other two configurations utilize water as heat transfer fluid. For the single-slabbed finned PCM-HX melting case, the mean deviation in average PCM temperature predicted by the GRCM compared to the CFD model was between 0.56 – 0.73 K, with maximum temperature deviation of 2.68 K. For the HTF outlet temperature, the validation results showed that GRCM prediction matches very well with experimental data, with mean temperature deviation of 0.24 K during melting case, while for solidification case was 0.34 K. These results showcase the GRCM’s capability for accurately reproducing the thermal characteristics of PCM-HXs with considerably lower computational effort.

42 ENGINEERING↗

Profiling and Improving I/O Performance of a Large-Scale Climate Scientific Application

Exascale computing systems are soon to emerge, which will pose great challenges on the huge gap between computing and I/O performance. Many large-scale scientific applications play an important role in our daily life. The huge amounts of data generated by such applications require highly parallel and efficient I/O management policies. In this paper, we adopt a mission-critical scientific application, GEOS-5, as a case to profile and analyze the communication and I/O issues that are preventing applications from fully utilizing the underlying parallel storage systems. Through in-detail architectural and experimental characterization, we observe that current legacy I/O schemes incur significant network communication overheads and are unable to fully parallelize the data access, thus degrading applications' I/O performance and scalability. To address these inefficiencies, we redesign its I/O framework along with a set of parallel I/O techniques to achieve high scalability and performance. Evaluation results on the NASA discover cluster show that our optimization of GEOS-5 with ADIOS has led to significant performance improvements compared to the original GEOS-5 implementation.

Exascale↗

Disruptive effect of Dzyaloshinskii-Moriya interaction on the magnetic memory cell performance

In order to increase the thermal stability of a magnetic random access memory cell, materials with high spin-orbit interaction are often introduced in the storage layer. As a side effect, a strong Dzyaloshinskii-Moriya interaction (DMI) may arise in such systems. Here, we investigate the impact of DMI on the magnetic cell performance, using micromagnetic simulations. We find that DMI strongly promotes non-uniform magnetization states and non-uniform switching modes of the magnetic layer. It appears to be detrimental for both the thermal stability of the cell and its switching current, leading to considerable deterioration of the cell performance even for a moderate DMI amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗