Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Maximum likelihood positioning algorithm for high-resolution PET scanners

Purpose: In high-resolution positron emission tomography (PET), lightsharing elements are incorporated into typical detector stacks to read out scintillator arrays in which one scintillator element (crystal) is smaller than the size of the readout channel. In order to identify the hit crystal by means of the measured light distribution, a positioning algorithm is required. One commonly applied positioning algorithm uses the center of gravity (COG) of the measured light distribution. The COG algorithm is limited in spatial resolution by noise and intercrystal Compton scatter. The purpose of this work is to develop a positioning algorithm which overcomes this limitation. Methods: The authors present a maximum likelihood (ML) algorithm which compares a set of expected light distributions given by probability density functions (PDFs) with the measured light distribution. Instead of modeling the PDFs by using an analytical model, the PDFs of the proposed ML algorithm are generated assuming a single-gamma-interaction model from measured data. The algorithm was evaluated with a hot-rod phantom measurement acquired with the preclinical HYPERION II {sup D} PET scanner. In order to assess the performance with respect to sensitivity, energy resolution, and image quality, the ML algorithm was compared to a COG algorithm which calculates the COG from a restricted set of channels. The authors studied the energy resolution of the ML and the COG algorithm regarding incomplete light distributions (missing channel information caused by detector dead time). Furthermore, the authors investigated the effects of using a filter based on the likelihood values on sensitivity, energy resolution, and image quality. Results: A sensitivity gain of up to 19% was demonstrated in comparison to the COG algorithm for the selected operation parameters. Energy resolution and image quality were on a similar level for both algorithms. Additionally, the authors demonstrated that the performance of the ML algorithm is less prone to missing channel information. A likelihood filter visually improved the image quality, i.e., the peak-to-valley increased up to a factor of 3 for 2-mm-diameter phantom rods by rejecting 87% of the coincidences. A relative improvement of the energy resolution of up to 12.8% was also measured rejecting 91% of the coincidences. Conclusions: The developed ML algorithm increases the sensitivity by correctly handling missing channel information without influencing energy resolution or image quality. Furthermore, the authors showed that energy resolution and image quality can be improved substantially by rejecting events that do not comply well with the single-gamma-interaction model, such as Compton-scattered events.

60 APPLIED LIFE SCIENCES↗

High resolution spectra of Venus.

The existing high resolution spectra of Venus show considerable variations in the abundance of CO2. As this is the major constituent of the atmosphere, these day-to-day variations indicate the effective reflecting cloud layer is undergoing substantial vertical displacements over a relatively short time scale. The published observations indicate that CO is uniformly mixed with the CO2, but that the lines of HF may be formed deeper in the atmosphere and HCl lines considerably deeper. These conclusions are based on extrapolations of laboratory measurements and could be considerably altered by new laboratory measurements made under conditions similar to those near the tropopause in Venus.

Young, L. D. G.↗

The TIROS-N high resolution infrared radiation sounder

The high-resolution infrared radiation sounder (HIRS/2) was developed and flown on the Television and Infrared Observation Satellite, N Series (TIROS-N) as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow spectral channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel, and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic performance of the instrument in test is described. Early orbital information from the TIROS-N launched on October 13, 1978 are given and some observations on system quality are made.

Koenig, E. W.↗

Optical alignment of high resolution Fourier transform spectrometers

Remote sensing, high resolution FTS instruments often contain three primary optical subsystems: Fore-Optics, Interferometer Optics, and Post, or Detector Optics. We discuss the alignment of a double-pass FTS containing a cat's-eye retro-reflector. Also, the alignment of fore-optics containing confocal paraboloids with a reflecting field stop which relays a field image onto a camera is discussed.

Breckinridge, J. B.↗

The abundances of CH4, CH3D, NH3, and PH3 in the troposphere of Jupiter derived from high-resolution 1100-1200/cm spectra

High-resolution spectra of the 1100-1200/cm region of the central part of Jupiter obtained in March 1980 and April 1981 are analyzed. The best fit NH3 distribution curve reveals a higher than solar mixing ratio, the abundance of NH3 to that of H2 being (3.3 + or - 1.7) x 10 to the -4th, below the 147 K layer (greater than 0.6 atmosphere). If NH3 ice particles are introduced as an opacity source, the NH3 mixing ratio below the 147 K layer can be lowered, but the fit is worse than that given by the model that excludes NH3 ice particles. The best fit PH3 distribution curve exhibits a PH3/H2 mixing ratio of (8.3 + or - 2.0) x 10 to the -7th in the troposphere. In addition, a CH4/H2 mixing ratio of (2.5 + or - 0.4) x 10 to the -3rd is found in the troposphere.

Knacke, R. F.↗

Coma morphology and dust-emission pattern of periodic comet Halley. III - Additional high-resolution images taken in 1910

High-resolution photographic images of comet Halley obtained at Lick, Helwan, Lowell, and Vienna observatories during May-June 1910 are analyzed using the image-processing algorithm of Larson and Sekanina (1984). The results are presented in tables and compared with analyses of Mt. Wilson plates for the same period (Sekanina and Larson, 1984), and good general agreement is noted. Consideration is given to the position of the rotation pole, features indicative of the nucleus spin rate, the spokelike structure observed on May 21-22, and the expanding gas halo.

Larson, S. M.↗

A high resolution ultraviolet Shuttle glow spectrograph

The High Resolution Shuttle Glow Spectrograph-B (HRSGS-B) is a small payload being developed by the Naval Research Laboratory. It is intended for study of shuttle surface glow in the 180-400 nm near- and middle-ultraviolet wavelength range, with a spectral resolution of 0.2 nm. It will search for, among other possible features, the band systems of excited NO which result from surface-catalyzed combination of N and O. It may also detect O2 Hertzberg bands and N2 Vegard-Kaplan bands resulting from surface recombination. This wavelength range also includes possible N2+ and OH emissions. The HRSGS-B will be housed in a Get Away Special canister, mounted in the shuttle orbiter payload bay, and will observe the glow on the tail of the orbiter.

Carruthers, George R.↗

Determination of Total Ozone over Mauna Loa Using Very High Resolution Infrared Solar Spectra

A very high resolution infrared Fourier transform spectrometer has been used to record solar spectra at the Mauna Loa Observatory in Hawaii. Spectra are normally taken one day a week at sunrise. These spectra have been analyzed for ozone and N2O total columns, and the ozone column compared with the value reported by tile Mauna Loa Dobson spectrophotometer. Aside from the FTIR reporting about 5% lower values than the Dobson (which may be due to a systematic difference in the treatment of tropospheric ozone), the FTIR and Dobson agree to within 2.7% (RMS) during this period.

David, Shelle J.↗

Reconstructing High Resolution ESM Data Through a Novel Fast Super Resolution Convolutional Neural Network (FSRCNN)

In this work, we present the first application of a fast super resolution convolutional neural network (FSRCNN) based approach for downscaling earth system model (ESM) simulations. Unlike other SR approaches, FSRCNN uses the same input feature dimensions as the low resolution input. This allows it to have smaller convolution layers, avoiding over-smoothing, and reducing computational costs. We adapt the FSRCNN to improve reconstruction on ESM data, we term the FSRCNN-ESM. We use high-resolution (~0.25°) monthly averaged model output of five surface variables over North America from the US Department of Energy's Energy Exascale Earth System Model's control simulation. These high-resolution and corresponding coarsened low-resolution (~1°) pairs of images are used to train the FSRCNN-ESM and evaluate its use as a downscaling approach. We find that FSRCNN-ESM outperforms FSRCNN and other super-resolution methods in reconstructing high resolution images producing finer spatial scale features with better accuracy for surface temperature, surface radiative fluxes, and precipitation.

58 GEOSCIENCES↗

Aspects of a high-resolution scheme for the Navier-Stokes equations

In this paper we emphasize the importance of the form of the numerical dissipation model in computing accurate viscous flow solutions. A high-resolution scheme for viscous flows based on three-point central differencing and a matrix dissipation is considered. The various components of this scheme, including 'entropy fix', limiter function, and boundary-point dissipation are discussed. By analyzing boundary-point dissipation stencils, we confirm that with the matrix dissipation model the normal numerical dissipation terms in the streamwise momentum equation are independent of the Reynolds number. Such independence is not achieved with a scalar dissipation form. The accuracy of the central-difference scheme, with and without matrix dissipation, and the flux-difference split scheme of Roe, which is classified as a high-resolution scheme, is compared. For this comparison, three high Reynolds number laminar flows are considered. Solutions of the Navier-Stokes equations are obtained for low-speed flow over a flat plate, transonic flow over an airfoil with transition near the leading edge, and hypersonic flow over a compression ramp. The emphasis of the comparison is primarily on the details of the viscous flows. The necessity of the high-resolution property is revealed.

Swanson, R. C.↗

Decon2LS: An Open-Source Software Package for Automated Processing and Visualization of High Resolution Mass Spectrometry Data

Data generated from liquid chromatography coupled to high-resolution mass spectrometry (LC-MS)-based studies of a biological sample can contain large amounts of biologically significant information in the form of proteins, peptides, and metabolites. Interpreting these data uses the mass spectra to infer masses and abundances of biomolecules injected into the instrument. Because of the inherent complexity of mass spectral patterns produced by these biomolecules, the analysis is significantly enhanced by using visualization capabilities to inspect and confirm results. In this paper we describe Decon2LS, an open-source software package for automated processing and visualization of high-resolution MS data. Drawing extensively on algorithms developed over the last ten years for ICR2LS, Decon2LS packages the algorithms as a rich set of modular, reusable processing classes for performing diverse functions such as raw data readers, routine peak finding, theoretical isotope distribution modelling, and deisotoping. Because the source code is openly available, these functionalities can now be used to build derivative applications in relatively fast manner. In addition, Decon2LS provides an extensive set of visualization tools, such as high performance chart controls.

59 BASIC BIOLOGICAL SCIENCES↗

Generalization Across Experimental Parameters in Neural Network Analysis of High-Resolution Transmission Electron Microscopy Datasets

Neural networks are promising tools for high-throughput and accurate transmission electron microscopy (TEM) analysis of nanomaterials, but are known to generalize poorly on data that is “out-of-distribution” from their training data. Given the limited set of image features typically seen in high-resolution TEM imaging, it is unclear which images are considered out-of-distribution from others. Here, we investigate how the choice of metadata features in the training dataset influences neural network performance, focusing on the example task of nanoparticle segmentation. We train and validate neural networks across curated, experimentally collected high-resolution TEM image datasets of nanoparticles under various imaging and material parameters, including magnification, dosage, nanoparticle diameter, and nanoparticle material. Overall, we find that our neural networks are not robust across microscope parameters, but do generalize across certain sample parameters. Additionally, data preprocessing can have unintended consequences on neural network generalization. Our results highlight the need to understand how dataset features affect deployment of data-driven algorithms.

42 ENGINEERING↗