Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Brightness measurement of an electron impact gas ion source for proton beam writing applications

We are developing a high brightness nano-aperture electron impact gas ion source, which can create ion beams from a miniature ionization chamber with relatively small virtual source sizes, typically around 100 nm. A prototype source of this kind was designed and successively micro-fabricated using integrated circuit technology. Experiments to measure source brightness were performed inside a field emission scanning electron microscope. The total output current was measured to be between 200 and 300 pA. The highest estimated reduced brightness was found to be comparable to the injecting focused electron beam reduced brightness. This translates into an ion reduced brightness that is significantly better than that of conventional radio frequency ion sources, currently used in single-ended MeV accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Oscillatory instability development in extraction system of a negative ion source

Conditions of oscillatory instability development in the extraction system of a negative hydrogen ion source based on a volume-produced plasma are studied. Such an ion source is characterized by the presence of the parent gas in the extraction system due to the leakage from the gas-discharge chamber. The secondary electrons in the area of the ion-optical system become the reason of oscillation appearance and possible beam current modulation. Analytically the range of the stable beam propagation is found. The instability increment is shown to be rather small. Maximum increment of the oscillations corresponds to the beam velocity equal to the thermal velocity of plasma electrons. The group velocity of the oscillations is close to the beam velocity so the oscillations are convective. Simulation of the low energy beam propagation is performed in COMSOL Multiphysics, the beam current modulation being observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Arc discharge regulation of a megawatt hot cathode bucket ion source for the experimental advanced superconducting tokamak neutral beam injector

Arc discharge of a hot cathode bucket ion source tends to be unstable what attributes to the filament self-heating and energetic electrons backstreaming from the accelerator. A regulation method, which based on the ion density measurement by a Langmuir probe, is employed for stable arc discharge operation and long pulse ion beam generation. Long pulse arc discharge of 100 s is obtained based on this regulation method of arc power. It establishes a foundation for the long pulse arc discharge of a megawatt ion source, which will be utilized a high power neutral beam injection device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance study of a 28 GHz electron cyclotron resonance ion source for the Rare Isotope Science Project superconducting linear accelerator

A 28 GHz electron cyclotron resonance (ECR) ion source is being developed for use as an injector for the superconducting linear accelerator of the Rare Isotope Science Project. Beam extraction from the ECR ion source has been simulated using the KOBRA3-INP software. The simulation software can calculate charged particle trajectories in three dimensional complex magnetic field structures, which in this case are formed by the arrangement of five superconducting magnets. In this study, the beam emittance is simulated to understand the effects of plasma potential, mass-to-charge ratio, and spatial distribution. The results of these simulations and their comparison to experimental results are presented in this paper.

43 PARTICLE ACCELERATORS↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A negative ion source test facility

Progress is being made in the development of an Ion Source Test Facility (ISTF) by D-Pace Inc. in collaboration with Buckley Systems Ltd. in Auckland, NZ. The first phase of the ISTF is to be commissioned in October 2015 with the second phase being commissioned in March 2016. The facility will primarily be used for the development and the commercialization of ion sources. It will also be used to characterize and further develop various D-Pace Inc. beam diagnostic devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University

At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ and SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D{sup +}, 10 mA of O{sup +}, 10 mA of He{sup +}, and 50 mA of H{sup +}). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

43 PARTICLE ACCELERATORS↗

Physics of a magnetic filter for negative ion sources. I. Collisional transport across the filter in an ideal, 1D filter

Magnetic filters are used in negative ion sources for neutral beam injection in fusion devices to reduce the electron temperature in the extraction region in order to limit negative ion destruction by fast electrons. The drop in electron temperature through the filter is due to the enhanced residence time and collisional energy losses of electrons trapped in the magnetic field. The mechanisms controlling particle and energy transport through the magnetic filter in negative ion sources of the ITER type are still not clear and the aim of this paper is to clarify and quantify these mechanisms. A particle-in-cell Monte Carlo simulation is used to revisit and analyze the role and operation of the magnetic filter in an 'ideal' one-dimensional configuration and to study the stability of the one-dimensional solution in a two-dimensional configuration with periodic boundary conditions. The roles of collisions and instabilities on electron transport through the filter are discussed. The influence of a more realistic geometry on electron transport through the filter is analyzed in the companion paper [Boeuf et al., Phys. Plasmas 19, 113510 (2012)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Research and Development of H Ion Source and LEBT for a Kaon-neutrino Factory

A baseline H{sup -} ion source and low energy beam transport system (LEBT) have been identified for Project X. The filament-discharge H{sup -} ion source has been fabricated by D-Pace, Inc. and is now in operation at LBNL. The source is capable of delivering over 10mA of H{sup -} beam in cw operation with normalized 4rms emittances less than 0.7 {pi} mm mrad. A two-solenoid magnetic lens LEBT system has been design. The design has been validated with simulations of beam transport for 5 mA 30 keV H- beams using various simulation codes.

43 PARTICLE ACCELERATORS↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Plasma characteristics of single- and dual-electrode ion source systems utilized in low-energy ion extraction

Discharge characteristics in the upstream as well as in the downstream regions of a 50-eV positive ion beam were measured along the beam axis. Single- and dual-electrode configurations made of 0.1-mm diameter tungsten wires were tested. By varying the upstream discharge parameters, the shape of the sheath edge around the extractors, which can either be “planar” or “cylindrical,” can be controlled. The sheath eventually affected the simultaneous extraction of ions and neutralizing electrons. The dual-electrode configuration at the lower discharge current, revealed a homogeneous discharge downstream. At this condition, the edge of the sheath can be inferred to be “planar” which allowed the uniform extraction and propagation of low-energy ions at longer distances. The dual-electrode configuration was capable of transmitting low-energy ions up to 70 mm downstream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation and optimization of a 10 A electron gun with electrostatic compression for the electron beam ion source

Increasing the current density of the electron beam in the ion trap of the Electron Beam Ion Source (EBIS) in BNL's Relativistic Heavy Ion Collider facility would confer several essential benefits. They include increasing the ions' charge states, and therefore, the ions' energy out of the Booster for NASA applications, reducing the influx of residual ions in the ion trap, lowering the average power load on the electron collector, and possibly also reducing the emittance of the extracted ion beam. Here, we discuss our findings from a computer simulation of an electron gun with electrostatic compression for electron current up to 10 A that can deliver a high-current-density electron beam for EBIS. The magnetic field in the cathode-anode gap is formed with a magnetic shield surrounding the gun electrodes and the residual magnetic field on the cathode is (5 Division-Sign 6) Gs. It was demonstrated that for optimized gun geometry within the electron beam current range of (0.5 Division-Sign 10) A the amplitude of radial beam oscillations can be maintained close to 4% of the beam radius by adjusting the injection magnetic field generated by a separate magnetic coil. Simulating the performance of the gun by varying geometrical parameters indicated that the original gun model is close to optimum and the requirements to the precision of positioning the gun elements can be easily met with conventional technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of superconducting magnets for RAON 28 GHz ECR ion source

RAON, a 28 GHz electron cyclotron resonance ion source (ECR IS), was designed and tested as a Rare Isotope Science Project. It is expected that RAON would provide not only rare-isotope beams but also stable heavy ions ranging from protons to uranium. In order to obtain the steady heavy-ion beam required for ECR IS, we must use a 28 GHz microwave source as well as a high magnetic field. A superconducting magnet using a NbTi wire was designed and manufactured for producing the ECR IS and a test was conducted. In this paper, the design and fabrication of the superconducting magnet for the ECR IS are presented. Experimental results show that the quench current increases whenever quenching occurs, but it has not yet reached the designed current. The experiment is expected to reveal the ideal conditions required to reach the designed current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Work function measurements during plasma exposition at conditions relevant in negative ion sources for the ITER neutral beam injection

Cesium seeded sources for surface generated negative hydrogen ions are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER. The stability and delivered current density depend highly on the work function during vacuum and plasma phases of the ion source. One of the most important quantities that affect the source performance is the work function. A modified photocurrent method was developed to measure the temporal behavior of the work function during and after cesium evaporation. The investigation of cesium exposed Mo and MoLa samples under ITER negative hydrogen ion based neutral beam injection relevant surface and plasma conditions showed the influence of impurities which result in a fast degradation when the plasma exposure or the cesium flux onto the sample is stopped. A minimum work function close to that of bulk cesium was obtained under the influence of the plasma exposition, while a significantly higher work function was observed under ITER-like vacuum conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of Ion Generation by a ps-laser for External Injection into Electron Beam Ion Source

We investigated ion generation from Al, Ti, Cu, Nb and Ta target elements by a picosecond-laser in the range of 10 11 – 10 13 W/cm 2 power densities at the target surface. A ps-laser with 1.27 mJ maximum energy within a 8 ps pulse and repetition rate up to 400 Hz has been used to generate a laser-ablated plasma. Dependencies of ion current vs time, total charge of registered ions as well as ion kinetic energy distributions are characterized using a Faraday cup. Significant difference in ion current dynamics between first, second and following shots onto the same target spot was found for all five target elements. The total charge of ions registered by the Faraday cup increase linearly with increasing laser pulse energy and are almost independent on the target element and number of shots onto the same target spot for all five target elements studied. Target craters have been examined using a commercially available microscope (Nikon Eclipse LV150) and crater cross section areas were found to be in the range of 0.0076 – 0.0172 mm 2 within the first five shots onto the same target spot for different target elements. A linear dependence of crater cross section square on laser pulse energy has been observed for the Ta target. Ion energy distributions for all target elements have a plateau or a slight peak in the energy range of 10 - 100 eV and long low-intensity energy tail up to tens of keV.

43 PARTICLE ACCELERATORS↗

Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Cold and Hot Electron Populations, Temperatures and Their Transports in the Edge Plasma of the ORNL CAPRICE ECR Ion Source

The edge plasma of the ORNL CAPRICE ECR ion source is studied by directly measuring, with electrical probes, its local plasma parameters such as plasma density, temperature and electron energy distribution characteristics at different rf power levels, at various pressures, at various axial magnetic field strengths and different distances from the resonant zone. It is found that the edge plasma can be approximated to be bi-Maxwellian, whose characteristics become more pronounced at the more distant positions from the ECR zone, at lower source pressures and at increased magnetic field strengths. These trends are consistently explained in terms of long-range electron-electron and electron-ion Coulomb scattering collisions that occur during the transport of hot electrons from the ECR plasma to the probe and their frequency dependence on electron temperature and density.

43 PARTICLE ACCELERATORS↗