Search NASA⌕ Search

SEARCH · Search NASA

Results for “IRRADIATION DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Dose rate and bias dependency of total dose sensitivity of low dropout voltage regulators

Total dose tests of six different low dropout voltage regulators show sensitivity to both dose rate and bias during exposure. All devices tested exhibited Enhanced Low Dose Rate Sensitivity (ELDRS) and performed worse for the unbiased irradiation condition. Behavior of critical parameters in different dose rate and bias conditions is compared and the impact to hardness assurance methodology is discussed.

Voltage↗

Selection and Use Considerations for Laser Power Photovoltaic Receivers

III-V PV receivers provide high performance over wide range of application conditions. Operating conditions including irradiance and cell temperature must be accounted for. Very high efficiencies demonstrated for small GaAs devices. Potential for significant future advances in performance, especially for other wavelengths and for cost.

GaAs↗

Correlation of a Bipolar-Transistor-Based Neutron Displacement Damage Sensor Methodology with Proton Irradiations

For this research, a bipolar-transistor-based sensor technique has been used to compare silicon displacement damage from known and unknown neutron energy spectra generated in nuclear reactor and high-energy-density physics environments. The technique has been shown to yield 1-MeV(Si) equivalent neutron fluence measurements comparable to traditional neutron activation dosimetry. This study significantly extends previous results by evaluating three types of bipolar devices utilized as displacement damage sensors at a nuclear research reactor and at a Pelletron particle accelerator. Ionizing dose effects are compensated for via comparisons with 10-keV x-ray and/or cobalt-60 gamma ray irradiations. Non-ionizing energy loss calculations adequately approximate the correlations between particle-device responses and provide evidence for the use of one particle type to screen the sensitivity of the other.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MO-E-BRD-02: Accelerated Partial Breast Irradiation in Brachytherapy: Is Shorter Better?

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-03: Intra-Operative Breast Brachytherapy: Is One Stop Shopping Best? [ Non-invasive Image-Guided Breast Brachytherapy ]

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-01: Is Non-Invasive Image-Guided Breast Brachytherapy Good?

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

MO-E-BRD-00: Breast Brachytherapy: The Phoenix of Radiation Therapy

Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant. A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.

60 APPLIED LIFE SCIENCES↗

Synthesis of Sb{sub 2}S{sub 3} nanowall arrays for high performance visible light photodetectors

Highlights: • Sb{sub 2}S{sub 3} nanowall arrays have been synthesized via a facile polyol refluxing process. • We fabricated Sb{sub 2}S{sub 3} rigid and flexible photodetectors successfully. • The photoelectric properties were studied upon visible light irradiation. • The rigid photodetector exhibit excellent photoconductive performance. - Abstract: By using a facile polyol and template-free refluxing process, we report the successful synthesis of Sb{sub 2}S{sub 3} nanowall arrays (NWAs) on the surface of FTO substrate. The as-synthesized samples were characterized by SEM, TEM, XRD and UV–vis DRS. The NWAs-based photodetector exhibits linear photocurrent characteristics, high stability, excellent reproducible properties, low LDR (linear dynamic range) value of 8.6 dB, fast response time of 0.52 s and recovery time of 1.11 s. The flexible photodetector was also fabricated by simply transferring the NWAs to a transparent PET substrate; it revealed good flexibility and stability. Our results imply that Sb{sub 2}S{sub 3} NWAs are prospective candidates for high-performance nanoscale optoelectronic devices.

36 MATERIALS SCIENCE↗

Single-event burnout in homojunction GaN vertical PiN diodes with hybrid edge termination design

GaN devices play a major role in modern electronics, providing high-power handling, efficient high-frequency operation, and resilience in harsh environments. However, electric field crowding at the edge of the anode often limits its full potential, leading to single-event effects (SEEs) at lower bias voltages under heavy ion radiation. Here, in this work, we report on the performance of homojunction GaN vertical PiN diodes with a hybrid edge termination design under heavy ion irradiation, specifically, oxygen ions, chlorine ions, Cf-252 fission fragments, and alpha particles from an Am-241 source. The unique hybrid edge termination (HET) design provides better electric field management, preventing breakdown from occurring at the edge of the anode at lower voltages. The results of this study reveal that these devices exhibit excellent tolerance to 12-MeV oxygen and 16-MeV chlorine ions, owing to their low linear energy transfer (LET) and range in GaN. However, single-event burnout (SEB) is observed during the Cf-252 exposure at about 50% of the diodes' electrical breakdown voltage due to the presence of higher LET and longer-range ions. Optical and scanning electron microscopy (SEM) reveal that the damage that caused by SEB lies close to the center of these devices rather than the anode edge. Devices with junction termination extension (JTE) instead of HET edge termination also show similar SEB when irradiated with Cf-252 fission fragments. Physical damage due to SEB occurs at the edge of the anode for these devices. These comparative results show the benefits of HET for enhancing the resistance of GaN-based PiN diodes to heavy ion irradiation.

42 ENGINEERING↗

Precise, reproducible nano-domain engineering in lithium niobate crystals

We present a technique for domain engineering the surface of lithium niobate crystals with features as small as 100 nm. A film of chromium (Cr) is deposited on the lithium niobate surface and patterned using electron beam lithography and lift-off and then irradiated with a wide diameter beam of intense visible laser light. The regions patterned with chromium are domain inverted while the uncoated regions are not affected by the irradiation. With the ability to realize nanoscale surface domains, this technique could offer an avenue for fabrication of nano-photonic and phononic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of Delayed Neutrons from Fissionable Samples: Monte Carlo Modelling and Physical Assumptions for a Design of the DET-12 Device

An activation of fissionable materials with neutrons has been considered as a possible neutron diagnostic of D–D and D–T fusion plasma. Fission reaction caused by fusion neutrons leads up to emission of secondary neutrons: prompt and delayed. Physical assumptions have been outlined to design a new device (DET-12) for measurements of delayed neutrons emitted from samples of fissionable materials activated with neutrons at big fusion-plasma devices. The aim is to support a classic neutron activation method used as one of plasma diagnostics at tokamaks or stellarators. An interpretation of the time decay of delayed neutrons enables an assessment of the primary neutron flux which induced fission reaction. Monte Carlo calculations have been carried out in order to elaborate the method considered. Nuclides like: pure {sup 235}U, {sup 238}U and {sup 232}Th, have been selected as possible materials to be irradiated. Physical fundamentals of generation of the delayed neutrons are mentioned and a resulting concept of the DET-12 device, built in the Institute of Nuclear Physics, Poland, is presented. A general size and dimensions of particular constituent material layers, and a number and placement of neutron detectors are optimized by means of Monte Carlo modelling. Recommendations for a technical design of the measuring chamber were formulated. Detection efficiency of DET-12 has been also estimated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high-efficiency, low-Ĉerenkov Micro-Layered Fast-Neutron Detector for the $\mathrm{TREAT}$ hodoscope

Here this paper presents an enabling technology for high-efficiency fast-neutron detection for the Transient Reactor Test (TREAT) Facility hodoscope. The hodoscope is currently outfitted with 25.4-mm long Hornyak buttons for fast-neutron detection. However, they require improvements, as they suffer from low detection efficiency, Ĉerenkov radiation contaminating the signal, and non-linearity of detector response at large transients. To address these issues, a layered ZnS:Ag device has been constructed. The layered design provides various advantages: it incorporates greater scintillation volume, Ĉerenkov background is significantly reduced by eliminating the need for additional light guides, and the detection process is simplified by achieving gamma-ray rejection using only pulse-height discrimination. The result is a greater number of fast neutron counts with reduced background noise contaminating the signal. On being irradiated with a 252Cf source (whose neutron energy spectrum closely mimics a reactor fission spectrum), a 25.4-mm long layered device was found to exhibit an intrinsic fast-neutron detection efficiency of 8.1% for neutrons with an average energy of 2 MeV, while a 43-mm long device allows for a greater number of fast neutron to be detected, increasing the efficiency to 9.1%. Further lengthening of the device up to 20 cm has been numerically predicted to exhibit even higher efficiencies. The detectors can be mass-produced easily and inexpensively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Mechanical Properties Analysis of Triple Ion-Beam Irradiated and Neutron Irradiated Potential Plasma Facing Components

Abstract Several classes of materials are being proposed for use in fusion reactors including oxide dispersion strengthened (ODS) and reduced activation ferritic-martensitic (RAF/M) steels to withstand the severe and harsh conditions. In this work, the mechanical properties of a Fe-16Cr-4Al-2W-0.3Ti-0.3Y 2 O 3 (K3) (ODS) ferritic steel and a Fe-8.9Cr-1.1W-0.47Mn-0.2V-0.14Ta-0.11C (Eurofer 97) (RAF/M) steel) after triple ion beam irradiation were locally evaluated utilizing in-situ micro-pillar compression tests, and continuous stiffness/quasi-static nanoindentation. No change in mechanical properties was observed in the K3 ODS steel. However, the Eurofer 97 RAF/M steel exhibited radiation-induced effects via increases in yield strength. Micro-pillar techniques were expanded to neutron-irradiated materials via an in-situ testing technique employing lift-out methods on Fe-14Cr-0.9Ti-0.3Mo-0.25Y 2 O 3 (MA957) ODS ferritic steel. Both the non-irradiated and irradiated compressive yield stresses of the MA 957 micro-pillars were in good agreement with bulk yield stress values reported in the literature, suggesting that the lift-out micro-pillar compression testing technique is a promising method. The demonstration of these techniques on ion beam and neutron irradiated ODS steels and ion beam RAF/M steels gives information to inform models of the material degradation during use in a fusion device.

alloys↗

Micro-Raman Analysis of Irradiated Diamond Films

Owing to its unique and robust physical properties, diamond is a much sought after material for use in advanced technologies, even in Microelectromechanical Systems (MEMS). The volume and weight savings promised by MEMS-based devices are of particular interest to spaceflight applications. However, much basic materials science research remains to be completed in this field. Results of micro-Raman analysis of proton (10(exp 15) - 10(exp 17) H(+)/sq cm doses) irradiated chemical vapor deposited (CVD) films are presented and indicate that their microstructure is retained even after high radiation exposure.

Newton, Robert L.↗

Proton irradiation effects in Molybdenum-Carbide-Graphite composites

The High Luminosity upgrade of the Large Hadron Collider (HL-LHC) has prompted the investigation of novel materials for beam-intercepting devices, and in particular for the collimators responsible for protecting the machine from beam losses. The HL-LHC collimation system will inevitably experience increased levels of radiation damage and undergo changes in their crucial physio-mechanical properties. Graphite-matrix composite materials containing molybdenum carbide particles, along with small amounts of titanium carbide, were developed with the objective of enhanced in-beam performance and tested under proton irradiation. The physical degradation observed in early grades of molybdenum carbide compounds, even after modest proton fluences, has prompted the development of advanced compounds. In this work, we examine the effects of proton irradiation on the microstructural and thermophysical properties of new grades of Molybdenum-carbide-graphite compounds up to fluences of ~2 × 10 20 p/cm 2 . Here, we employ a combination of precision dilatometry and high-energy X-ray diffraction to quantify the dimensional stability and crystallographic phase evolution both pre- and post-irradiation. Our results reveal that these new compounds exhibit superior resilience to radiation damage than their predecessors.

36 MATERIALS SCIENCE↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Refining Absorber Shroud Geometry to Maximize Power Output and Reduce Power Peaking in ATF Test Train

In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refining Absorber Shroud Geometry to Maximize Power Output and Reduce Power Peaking in ATF Test Train

In the wake of the Fukushima Daiichi nuclear power plant accident in 2011, the accident tolerant fuels (ATF) program was initiated to enhance the safety of light-water reactor fuels, placing significant emphasis on cladding. A crucial step for the broad implementation of ATF in commercial reactors involves irradiation testing of the fuel designs. ATF-2D, the latest experiment in the ATF series, is slated to undergo irradiation in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). ATF-2D is a joint effort of the INL with industry partners General Electric Global Research; Framatome; General Atomics; the Japan Atomic Energy Agency; Hitachi-GE Nuclear Energy, Ltd; Global Nuclear Fuel-Japan Co., Ltd; Nippon Nuclear Fuel Development Co., Ltd; and Mitsubishi Heavy Industries, Ltd. The ATF-2D test train design consists of four tiers, each housing six rodlets. The device will be inserted in Loop 2A within the central flux trap of the ATR, and is anticipated to undergo irradiation throughout three 60-day cycles. Typical pressurized water reactor conditions will be emulated during the irradiation. The objective of the work presented here is to dimension neutron-absorbing hafnium (Hf) components surrounding the fuel rodlets, such that the axial power profile is flattened, while simultaneously ensuring that the total fission power output of the entire test train remains below 200 kW.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗