Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging

Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuable tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.

60 APPLIED LIFE SCIENCES↗

Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of a water quality imager for coastal zone missions

The present work surveys water quality user requirements and then determines the general characteristics of an orbiting imager (the Applications Explorer, or AE) dedicated to the measurement of water quality, which could be used as a low-cost means of testing advanced imager concepts and assessing the ability of imager techniques to meet the goals of a comprehensive water quality monitoring program. The proposed imager has four spectral bands, a spatial resolution of 25 meters, and swath width of 36 km with a pointing capability of 330 km. Silicon photodetector arrays, pointing systems, and several optical features are included. A nominal orbit of 500 km altitude at an inclination of 50 deg is recommended.

Staylor, W. F.↗

Non-destructive Faraday imaging of dynamically controlled ultracold atoms

We describe an easily implementable method for non-destructive measurements of ultracold atomic clouds based on dark field imaging of spatially resolved Faraday rotation. The signal-to-noise ratio is analyzed theoretically and, in the absence of experimental imperfections, the sensitivity limit is found to be identical to other conventional dispersive imaging techniques. The dependence on laser detuning, atomic density, and temperature is characterized in a detailed comparison with theory. Due to low destructiveness, spatially resolved images of the same cloud can be acquired up to 2000 times. The technique is applied to avoid the effect of shot-to-shot fluctuations in atom number calibration, to demonstrate single-run vector magnetic field imaging and single-run spatial imaging of the system's dynamic behavior. This demonstrates that the method is a useful tool for the characterization of static and dynamically changing properties of ultracold atomic clouds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Simple Method for Improving the Spatial Resolution in Infrared Laser Ablation Mass Spectrometry Imaging

In mass spectrometry imaging of tissues, the size of structures that can be distinguished is determined by the spatial resolution of the imaging technique. Here, the spatial resolution of IR laser ablation is markedly improved by increasing the distance between the laser and the focusing lens. As the distance between the laser and the lens is increased from 1 to 18 m, the ablation spot size decreases from 440 to 44 μm. This way, only the collimated center of the divergent laser beam is directed on the focusing lens, which results in better focusing of the beam. Part of the laser energy is lost at longer distance, but this is compensated by focusing of the radiation to a smaller area on the sample surface. The long distance can also be achieved by a set of mirrors, between which the radiation travels before it is directed to the focusing lens and the sample. This method for improving the spatial resolution can be utilized in mass spectrometry imaging of tissues by techniques that utilize IR laser ablation, such as laser ablation electrospray ionization, laser ablation atmospheric pressure photoionization, and matrix-assisted laser desorption electrospray ionization. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: High-pressure in situ x-ray laminography using diamond anvil cell

A high-pressure in situ X-ray laminography technique was developed using a newly designed, laterally open diamond anvil cell. A low X-ray beam of 8 keV energy was used, aiming at future application to dual energy X-ray chemical imaging techniques. The effects of the inclination angle and the imaging angle range were evaluated at ambient pressure using the apparatus. Sectional images of ruby ball samples were successfully reconstructed at high pressures, up to approximately 50 GPa. The high-pressure in situ X-ray laminography technique is expected to provide new insights into the deep Earth sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automating High-Precision X-Ray and Neutron Imaging Applications with Robotics

Los Alamos National Laboratory and the University of Texas at Austin recently implemented a robotically controlled nondestructive testing (NDT) system for X-ray and neutron imaging. This system is intended to address the need for accurate measurements for a variety of parts and, be able to track measurement geometry at every imaging location, and is designed for high-throughput applications. This system was deployed in a beam port at a nuclear research reactor and in an operational inspection X-ray bay. The nuclear research reactor system consisted of a precision industrial seven-axis robot, 1.1-MW TRIGA research reactor, and a scintillator-mirror-camera-based imaging system. The X-ray bay system incorporated the same robot, a 225-keV microfocus X-ray source, and a custom flat panel digital detector. The robotic positioning arm is programmable and allows imaging in multiple configurations, including planar, cylindrical, as well as other user defined geometries that provide enhanced engineering evaluation capability. The imaging acquisition device is coupled with the robot for automated image acquisition. The robot can achieve target positional repeatability within 17 μm in the 3-D space. Flexible automation with nondestructive imaging saves costs, reduces dosage, adds imaging techniques, and achieves better quality results in less time. Specifics regarding the robotic system and imaging acquisition and evaluation processes are presented. In conclusion, this paper reviews the comprehensive testing and system evaluation to affirm the feasibility of robotic NDT, presents the system configuration, and reviews results for both X-ray and neutron radiography imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparsity-based photoacoustic image reconstruction with a linear array transducer and direct measurement of the forward model

Photoacoustic (PA) imaging is an emerging imaging technique for many clinical applications. One of the challenges posed by clinical translation is that imaging systems often rely on a finite-aperture transducer rather than a full tomography system. This results in imaging artifacts arising from an underdetermined reconstruction of the initial pressure distribution (IPD). Furthermore, clinical applications often require deep imaging, resulting in a low-signal-to-noise ratio for the acquired signal because of strong light attenuation in tissue. Conventional approaches to reconstruct the IPD, such as back projection and time-reversal, do not adequately suppress the artifacts and noise. We propose a sparsity-based optimization approach that improves the reconstruction of IPD in PA imaging with a linear array ultrasound transducer. In simulation studies, the forward model matrix was measured from k-Wave simulations, and the approach was applied to reconstruct simulated point objects and the Shepp–Logan phantom. The results were compared with the conventional back projection, time-reversal approach, frequency-domain reconstruction, and the iterative least-squares approaches. In experimental studies, the forward model of our imaging system is directly measured by scanning a graphite point source through the imaging field of view. Experimental images of graphite inclusions in tissue-mimicking phantoms are reconstructed and compared with the back projection and iterative least-squares approaches. Altogether these results show that our proposed optimization approach can leverage the sparsity of the PA images to improve the reconstruction of the IPD and outperform the existing popular reconstruction approaches.

47 OTHER INSTRUMENTATION↗

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

Material property analytical relations for the case of an AFM probe tapping a viscoelastic surface containing multiple characteristic times

We explore the contact problem of a flat-end indenter penetrating intermittently a generalized viscoelastic surface, containing multiple characteristic times. This problem is especially relevant for nanoprobing of viscoelastic surfaces with the highly popular tapping-mode AFM imaging technique. By focusing on the material perspective and employing a rigorous rheological approach, we deliver analytical closed-form solutions that provide physical insight into the viscoelastic sources of repulsive forces, tip-sample dissipation and virial of the interaction. We also offer a systematic comparison to the well-established standard harmonic excitation, which is the case relevant for dynamic mechanical analysis (DMA) and for AFM techniques where tip–sample sinusoidal interaction is permanent. This comparison highlights the substantial complexity added by the intermittent-contact nature of the interaction, which precludes the derivation of straightforward equations as is the case for the well-known harmonic excitations. The derivations offered have been thoroughly validated through numerical simulations. Despite the complexities inherent to the intermittent-con-tact nature of the technique, the analytical findings highlight the potential feasibility of extracting meaningful viscoelastic properties with this imaging method.

36 MATERIALS SCIENCE↗

Qualitative and quantitative imaging in microgravity combustion

An overview of the imaging techniques implemented by researchers in the microgravity combustion program shows that for almost any system, imaging of the flame may be accomplished in a variety of ways. Standard and intensified video, high speed, and infrared cameras and fluorescence, laser schlieren, rainbow schlieren, soot volume fraction, and soot temperature imaging have all been used in the laboratory and many in reduced gravity to make the necessary experimental measurements.

Weiland, Karen J.↗

Seismic Holography of Solar Activity

The basic goal of the project was to extend holographic seismic imaging techniques developed under a previous NASA contract, and to incorporate phase diagnostics. Phase-sensitive imaging gives us a powerful probe of local thermal and Doppler perturbations in active region subphotospheres, allowing us to map thermal structure and flows associated with "acoustic moats" and "acoustic glories". These remarkable features were discovered during our work, by applying simple acoustic power holography to active regions. Included in the original project statement was an effort to obtain the first seismic images of active regions on the Sun's far surface.

Lindsey, Charles↗

First spectroscopic observation of gold(I) butadiynylide: Photodetachment velocity map imaging of the AuC{sub 4}H anion

The velocity map imaging technique was used in the investigation of gold(I) butadiynylide, AuC{sub 4}H{sup −}, with images recorded at two excitation wavelengths. The resultant photodetachment spectra show a well defined vibrational progression in the neutral with an energy spacing of 343 ± 3 cm{sup −1}. The adiabatic electron affinity was determined to be 1.775 ± 0.005 eV and assigned to the X{sup 1}Σ{sup +}←X{sup 2}Σ{sup +} transition between the anionic and neutral ground states. Franck-Condon simulations performed on density functional theory optimized geometries assisted the assignment of linear geometries to the neutral and anion and the observed vibrational progression to that of the Au–C{sub 4}H stretch.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Modes for Ground Penetrating Radar and Their Relation to Detection Performance

The focus of this paper is an empirical study conducted to determine how imaging modes for ground penetrating radar (GPR) affect buried object detection performance. GPR data was collected repeatedly over lanes whose buried objects were mostly non-metallic. This data was collected and processed with a GPR antenna array, system hardware, and processing software developed by the authors and their colleagues. The system enables GPR data to be collected, imaged, and processed in real-time on a moving vehicle. The images are focused by applying multistatic and synthetic aperture imaging techniques either separately or jointly to signal scans acquired by the GPR antenna array. An image-based detection statistic derived from the ratio of buried object energy in the foreground to energy of soil in the background is proposed. Detection – false alarm performance improved significantly when the detection algorithm was applied to focused multistatic synthetic aperture radar (SAR) images rather than to unfocused GPR signal scans.

47 OTHER INSTRUMENTATION↗

Plasma properties of hot coronal loops utilizing coordinated SMM and solar research rocket observations

Three improvements in photographic x-ray imaging techniques for solar astronomy are presented. The testing and calibration of a new film processor was conducted; the resulting product will allow photometric development of sounding rocket flight film immediately upon recovery at the missile range. Two fine grained photographic films were calibrated and flight tested to provide alternative detector choices when the need for high resolution is greater than the need for high sensitivity. An analysis technique used to obtain the characteristic curve directly from photographs of UV solar spectra were applied to the analysis of soft x-ray photographic images. The resulting procedure provides a more complete and straightforward determination of the parameters describing the x-ray characteristic curve than previous techniques. These improvements fall into the category of refinements instead of revolutions, indicating the fundamental suitability of the photographic process for x-ray imaging in solar astronomy.

Moses, J. Daniel↗

Influence of Pore Water on the Fracture of Silica Sand at Particle Scale

The fracture of particles has a significant influence on the engineering behavior of granular materials. There are no reported conclusive answers in the literature to explain the influence of pore water on the fracture of sand, gravel, railroad ballast rock, aggregates, rockfill, and so on. Here, in this paper, two novel techniques were adopted to investigate the influence of pore water on the fracture of natural silica sand at the particle scale. The three-dimensional (3D) synchrotron microcomputed tomography (SMT) imaging technique was used to acquire and analyze multiple 3D images of specimens composed of wetted silica sand that were subjected to confined one-dimensional (1D) compression loading up to the fracture stage. A few representative particles were identified and digitally separated from the liquid water and gas phases. The 3D SMT images offer clear experimental evidence of the phase transition of water from liquid to gas within the opening cracks. In addition, a computational fluid dynamics numerical simulation framework for water flow into an opening crack was adopted and the results show that the fast opening of the crack induced cavitation, water phase transition, and water hammer effects. The results of the numerical simulations agree with the confined 1D compression experiments where the onset of the bubbles (gas phase) within the crack is mainly generated during the secondary cavitation stage, and the generated bubble near the crack mouth opening resulted from the primary cavitation, which was directly caused by the crack expansion. The results reported in this paper present a new cavitation phenomenon that occurs during particle fracture, which offers a physics-based explanation of why water-wetted sand fractures at smaller stresses than dry and can pave the way for more in-depth future studies on the fracture of water-wetted sand.

cavitation↗

Structural and elemental changes in glioblastoma cells in situ : complementary imaging with high resolution visible light- and X-ray microscopy

The glioblastoma (GBM) is characterized by a short median survival and an almost 100% tumor related mortality. GBM cells exhibit highly invasive behavior whose mechanisms are not yet fully understood. The present study explores application of X-ray and visible light microscopy to display the elemental and structural images of cells from 3 patient derived GMB samples and an established GMB cell line. Slight differences in elemental concentrations, in actin cytoskeleton organization and cell morphology were noted between all cells types by X-ray fluorescence and full field soft X-ray microscopy, as well as the Structured Illumination Super-resolution Microscope (SIM). Different sample preparation approaches were used to match each imaging technique. While preparation for SIM included cell fixation and staining, intact frozen hydrated cells were used for the trace element imaging by hard X-ray fluorescence and exploration of the structural features by soft X-ray absorption tomography. In conclusion, each technique documented differences between samples with regard to morphology and elemental composition and underscored the importance of use of multiple patient derived samples for detailed GBM study.

59 BASIC BIOLOGICAL SCIENCES↗