Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

Convective rainfall estimation from digital GOES-1 infrared data

An investigation was conducted to determine the feasibility of developing and objective technique for estimating convective rainfall from digital GOES-1 infrared data. The study area was a 240 km by 240 km box centered on College Station, Texas (Texas A and M University). The Scofield and Oliver (1977) rainfall estimation scheme was adapted and used with the digital geostationary satellite data. The concept of enhancement curves with respect to rainfall approximation is discussed. Raingage rainfall analyses and satellite-derived rainfall estimation analyses were compared. The correlation for the station data pairs (observed versus estimated rainfall amounts) for the convective portion of the storm was 0.92. It was demonstrated that a fairly accurate objective rainfall technique using digital geostationary infrared satellite data is feasible. The rawinsonde and some synoptic data that were used in this investigation came from NASA's Atmospheric Variability Experiment, AVE 7.

Sickler, G. L.↗

Development of a tunable Fabry-Perot etalon-based near-infrared interference spectrometer for measurement of the HeI 2{sup 3}S-2{sup 3}P spectral line shape in magnetically confined torus plasmas

In magnetically confined torus plasmas, the local emission intensity, temperature, and flow velocity of atoms in the inboard and outboard scrape-off layers can be separately measured by a passive emission spectroscopy assisted by observation of the Zeeman splitting in their spectral line shape. To utilize this technique, a near-infrared interference spectrometer optimized for the observation of the helium 2{sup 3}S–2{sup 3}P transition spectral line (wavelength 1083 nm) has been developed. The applicability of the technique to actual torus devices is elucidated by calculating the spectral line shapes expected to be observed in LHD and QUEST (Q-shu University Experiment with Steady State Spherical Tokamak). In addition, the Zeeman effect on the spectral line shape is measured using a glow-discharge tube installed in a superconducting magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote sensing in hydrology: A survey of applications with selected bibliography and abstracts

Remote infrared sensing as a water exploration technique is demonstrated. Various applications are described, demonstrating that infrared sensors can locate aquifers, geothermal water, water trapped by faults, springs and water in desert regions. The potentiality of airborne IR sensors as a water prospecting tool is considered. Also included is a selected bibliography with abstracts concentrating on those publications which will better acquaint the hydrologist with investigations using thermal remote sensors as applied to water exploration.

Sers, S. W.↗

Synopsis of current satellite snow mapping techniques, with emphasis on the application of near-infrared data

The Skylab EREP S192 Multispectral Scanner data have provided for the first time an opportunity to examine the reflectance characteristics of snowcover in several spectral bands extending from the visible into the near-infrared spectral region. The analysis of the S192 imagery and digital tape data indicates a sharp drop in reflectance of snow in the near-infrared, with snow becoming essentially nonreflective in Bands 11 (1.55-1.75 micron) and 12 (2.10-2.35 micron). Two potential applications to snow mapping of measurements in the near-infrared spectral region are possible: (1) the use of a near-infrared band in conjunction with a visible band to distinguish automatically between snow and water droplet clouds; and (2) the use of one or more near-infrared bands to detect areas of melting snow.

Barnes, J. C.↗

Study of optical techniques for the Ames unitary wind tunnel. Part 5: Infrared imagery

A survey of infrared thermography for aerodynamics was made. Particular attention was paid to boundary layer transition detection. IR thermography flow visualization of 2-D and 3-D separation was surveyed. Heat transfer measurements and surface temperature measurements were also covered. Comparisons of several commercial IR cameras were made. The use of a recently purchased IR camera in the Ames Unitary Plan Wind Tunnels was studied. Optical access for these facilities and the methods to scan typical models was investigated.

Lee, George↗

Emerging Techniques for Vicarious Calibration of Visible Through Short Wave Infrared Remote Sensing Systems

Simple field-portable white light LED calibration source shows promise for visible range (420-750 nm) 1) Prototype demonstrated <0.5% drift over 10-40 C temperature range; 2) Additional complexity (more LEDs) will be necessary for extending spectral range into the NIR and SWIR; 3) LED long lifetimes should produce at least several hundreds of hours or more stability, minimizing need for expensive calibrations and supporting long-duration field campaigns; and 4) Enabling technology for developing autonomous sites.

Ryan, Robert E.↗

Emerging Techniques for Vicarious Calibration of Visible Through Short Wave Infrared Remote Sensing Systems

Autonomous Visible to SWIR ground-based vicarious Cal/Val will be an essential Cal/Val component with such a large number of systems. Radiometrically calibrated spectroradiometers can improve confidence in current ground truth data through validation of radiometric modeling and validation or replacement of traditional sun photometer measurement. They also should enable significant reduction in deployed equipment such as equipment used in traditional sun photometer approaches. Simple, field-portable, white-light LED calibration source shows promise for visible range (420-750 nm). Prototype demonstrated <0.5% drift over 10-40 C temperature range. Additional complexity (more LEDs) will be necessary for extending spectral range into the NIR and SWIR. LED long lifetimes should produce at least several hundreds of hours or more of stability, minimizing the need for expensive calibrations and supporting long-duration field campaigns.

Ryan, Robert E.↗

Trace-gas sensing using the compliance voltage of an external cavity quantum cascade laser

Quantum cascade lasers (QCLs) are increasingly being used to detect, identify, and measure levels of trace gases in the air. External cavity QCLs (ECQCLs) provide a broadly-tunable infrared source to measure absorption spectra of chemicals and provide high detection sensitivity and identification confidence. Applications include detecting chemical warfare agents and toxic industrial chemicals, monitoring building air quality, measuring greenhouse gases for atmospheric research, monitoring and controlling industrial processes, analyzing chemicals in exhaled breath for medical diagnostics, and many more. Compact, portable trace gas sensors enable in-field operation in a wide range of platforms, including handheld units for use by first responders, fixed installations for monitoring air quality, and lightweight sensors for deployment in unmanned aerial vehicles (UAVs). We present experimental demonstration of a new chemical sensing technique based on intracavity absorption in an external cavity quantum cascade laser (ECQCL). This new technique eliminates the need for an infrared photodetector and gas cell by detecting the intracavity absorption spectrum in the compliance voltage of the laser device itself. To demonstrate and characterize the technique, we measure infrared absorption spectra of chemicals including water vapor and Freon-134a. Sub-ppm detection limits in one second are achieved, with the potential for increased sensitivity after further optimization. The technique enables development of handheld, high-sensitivity, and high-accuracy trace gas sensors for in-field use.

infrared spectroscopy, quantum cascade laser, trac↗

Deep Full-sky Coadds from Three Years of WISE and NEOWISE Observations

We have reprocessed over 100 terabytes of single-exposure Wide-field Infrared Survey Explorer ( WISE )/NEOWISE images to create the deepest ever full-sky maps at 3–5 microns. We include all publicly available W1 and W2 imaging—a total of ∼8 million exposures in each band—from ∼37 months of observations spanning 2010 January to 2015 December. Our coadds preserve the native WISE resolution and typically incorporate ∼3× more input frames than those of the AllWISE Atlas stacks. Our coadds are designed to enable deep forced photometry, in particular for the Dark Energy Camera Legacy Survey (DECaLS) and Mayall z-Band Legacy Survey (MzLS), both of which are being used to select targets for the Dark Energy Spectroscopic Instrument. We describe newly introduced processing steps aimed at leveraging added redundancy to remove artifacts, with the intent of facilitating uniform target selection and searches for rare/exotic objects (e.g., high-redshift quasars and distant galaxy clusters). Forced photometry depths achieved with these coadds extend 0.56 (0.46) magnitudes deeper in W1 (W2) than is possible with only pre-hibernation WISE imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

A TRMM-Calibrated Infrared Rainfall Algorithm Over Brazil

An improved version of the Convective/Stratiform Technique (CST) and its application over Brazil are presented. Keeping the major components of traditional CST, we have modified the scheme for classing convective and stratiform rainfall and tested various schemes to eliminate non-raining cirrus clouds. The parameters of the technique are calibrated using Tropical Rainfall Measuring Mission (TRMM) multi-sensor observations, including TMI, PR and Visible Infrared Scanner (VIRS). This technique takes advantage of the high temporal sampling rate of geosynchronous infrared channel and the better instantaneous rain observation of TRMM Microwave Imager (TMI) and PR. Moreover, sparse TMI rain estimates are used to dynamically calibrate the parameters of the technique to improve its performance. The technique is applied to make rainfall estimates on various time scales and to study rainfall statistics such as the distributions of rain intensity and storm duration over a four-month period beginning January 1999. The study period coincides with the TRMM/Large-Scale Biosphere-Atmosphere experiment in Amazonia (LBA) ground validation experiment, and observations from the LBA radar are used to validate the technique. Results show the mean diurnal cycle of precipitation over the LBA area, and are compared to radar data from the Tropical Oceans and Global Atmosphere (TOGA) radar. When the larger geographic region is considered, the analysis of the mean hourly estimates revealed the pronounced effects of rivers, topography and local circulations on the rainfall.

Negri, Andrew J.↗

Utilization of ERTS-1 for appraising changes in continental migratory bird habitat

The author has identified the following significant results. Information on numbers, distribution, and quality of wetlands in the breeding range of migratory waterfowl is important for the management of this wildlife resource. Using computer processing of data gathered by the ERTS-1 multispectral scanner, techniques for obtaining indices of annual waterfowl recruitment, and habitat quality are examined. As a primary task, thematic maps and statistics relating to open surface water were produced. Discrimination of water was based upon water's low apparent radiance in a single, near-infrared waveband. An advanced technique using multispectral information for discerning open water at a level of detail finer than the virtual resolution of the data was also successfully tested. In another related task, vegetation indicators were used for detecting conditions of latent or occluded water and upland habitat characteristics.

Gilmer, D. S.↗

High Resolution Near Infrared Spectrometer to Study the Zodiacal Light Spectrum

We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 612, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I line at 5184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program.

Kutyrev, Alexander↗

High Efficiency Near Infrared Spectrometer for Zodiacal Light Spectral Study

We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 61 2, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I l~neat 5 184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program.

Kutyrea, A. S.↗

Comprehensive analysis of Shuttle Orbiter leeside surface infrared imagery obtained during atmospheric entry

The thermographic analysis techniques developed for processing of data from the Shuttle Infrared Leeside Temperature Sensing (SILTS) experiment are discussed. The SILTS experiment will obtain high-spatial-resolution infrared images of the leeside of the Space Shuttle Orbiter during atmospheric entry by means of a scanning infrared radiometer located atop the orbiter's vertical stabilizer. Comprehensive analysis of the SILTS thermography requires accurate consideration of all those factors (such as geometry of the observed surfaces, local surface emissivity, solar radiation, and other potential sources of image degradation) which may potentially affect the output of the infrared radiometer. An overview of the entire data processing procedure and brief descriptions of the data processing algorithms are presented.

Myrick, D. L.↗

Comparison of CALIPSO-Like, LaRC, and MODIS Retrievals of Ice Cloud Properties over SIRTA in France and Florida during CRYSTAL-FACE

This study compares cirrus particle effective radius retrieved by a CALIPSO-like method with two similar methods using MODIS, MODI Airborne Simulator (MAS), and GOES imagery. The CALIPSO-like method uses lidar measurements coupled with the split-window technique that uses the infrared spectral information contained at the 8.65-micrometer, 11.15-micrometer and 12.05-micrometer bands to infer the microphysical properties of cirrus clouds. The two other methods, sing passive remote sensing at visible and infrared wavelengths, are the operational MODIS cloud products (referred to by its archival product identifier MOD06 for MODIS Terra) and MODIS retrievals performed by the CERES team at LaRC (Langley Research Center) in support of CERES algorithms; the two algorithms will be referred to as MOD06- and LaRC-method, respectively. The three techniques are compared at two different latitudes: (i) the mid-latitude ice clouds study uses 18 days of observations at the Palaiseau ground-based site in France (SIRTA: Site Instrumental de Recherche par Teledetection Atmospherique) including a ground-based 532 nm lidar and the Moderate Resolution Imaging Spectrometer (MODIS) overpasses on the Terra Platform, (ii) the tropical ice clouds study uses 14 different flight legs of observations collected in Florida, during the intensive field experiment CRYSTAL-FACE (Cirrus Regional Study of Tropical Anvils and cirrus Layers-Florida Area Cirrus Experiment), including the airborne Cloud Physics Lidar (CPL) and the MAS. The comparison of the three methods gives consistent results for the particle effective radius and the optical thickness, but discrepancies in cloud detection and altitudes. The study confirms the value of an active remote-sensing method (CALIPSO-like) for the study of sub-visible ice clouds, in both mid-latitudes and tropics. Nevertheless, this method is not reliable in optically very thick tropical ice clouds.

Chiriaco, M.↗

Characterization of Mid-Infrared Single Mode Fibers as Modal Filters

We present a technique for measuring the modal filtering ability of single mode fibers. The ideal modal filter rejects all input field components that have no overlap with the fundamental mode of the filter and does not attenuate the fundamental mode. We define the quality of a nonideal modal filter Q(sub f) as the ratio of transmittance for the fundamental mode to the transmittance for an input field that has no overlap with the fundamental mode. We demonstrate the technique on a 20 cm long mid-infrared fiber that was produced by the U.S. Naval Research Laboratory. The filter quality Q(sub f) for this fiber at 10.5 micron wavelength is 1000 +/- 300. The absorption and scattering losses in the fundamental mode are approximately 8 dB/m. The total transmittance for the fundamental mode, including Fresnel reflections, is 0.428 +/- 0.002. The application of interest is the search for extrasolar Earthlike planets using nulling interferometry. It requires high rejection ratios to suppress the light of a bright star, so that the faint planet becomes visible. The use of modal filters increases the rejection ratio (or, equivalently, relaxes requirements on the wavefront quality) by reducing the sensitivity to small wavefront errors. We show theoretically that, exclusive of coupling losses, the use of a modal filter leads to the improvement of the rejection ratio in a two-beam interferometer by a factor of Q(sub f).

single mode fibers↗