Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Lidar Observations of Raman Scattering from S02 in a Power Plant Stack Plume

LIDAR techniques have been successfully applied to the detection of the Raman backscatter from S02 in the plume of a 200 megawatt coal-burning electrical- generating plant from a distance of 210 meters. The LIDAR system used consists of a 61-centimeter-diameter, f /4 Newtonian telescope and a 1.0-1.5-joules per pulse, 1-pulse-per-second ruby laser. Narrow band interference filters are used to select the 7546-angstrom v (sub 1) vibrational line of S02. The signal from a photomultiplier tube was sequentially applied to each 254-nanosecond-wide channel of a 15-cihannel photon counting system, resulting in a direct correlation between channel number and range increment. Photon counts were accumulated from the backscatter of a number of laser pulses (typically 50 or 100), and the accumulated counts per channel printed on paper tape. One sequence of measurements was made during a two-hour period while the plant electrical output was being reduced by approximately 50 percent. Although the Raman system had not been quantitatively calibrated, the LIDAR data correlated well with the varying plant electrical output. N2 scattering observations were also made and an approximate quantitative S02 concentration obtained by ratioing the S02 data to N2 data. This ratio compared well to the in-situ measurements made during the same period by Environmental Protection Agency sampling instruments.

Brumfield, M. L.↗

The angular diameter of X Cancri.

Analysis of an occultation reappearance of the semiregular variable X Cancri observed with the 107-inch telescope of McDonald Observatory on 9 November 1971 by the laser group using slightly modified laser equipment. The problem of the effective temperature of this carbon star is discussed, and estimates near 2500 K are derived both from the occultation data and from an integration based on the multicolor photometry reported by Mendoza (1967). This figure is 300-400 K higher than Mendoza's calibration, and it is clear that unsolved problems remain in many areas connected with these stars.

Bartholdi, P.↗

Laser doppler velocimeter system for subsonic jet mixer nozzle testing at the NASA Lewis Aeroacoustic Propulsion Lab

A laser Doppler velocimeter (LDV) system developed for the Aeroacoustic Propulsion Laboratory (APL) at the NASA Lewis Research Center is described. This system was developed to acquire detailed flow field data which could be used to quantify the effectiveness of internal exhaust gas mixers (IEGM's) and to verify and calibrate computational codes. The LDV was used as an orthogonal, three component system to measure the flow field downstream of the exit of a series of IEGM's and a reference axisymmetric splitter configuration. The LDV system was also used as a one component system to measure the internal axial flow within the nozzle tailpipe downstream of the mixers. These IEGM's were designed for low-bypass ratio turbofan engines. The data were obtained at a simulated low flight speed, high-power operating condition. The optical, seeding, and data acquisition systems of the LDV are described in detail. Sample flow field measurements are provided to illustrate the capabilities of the system at the time of this test, which represented the first use of LDV at the APL. A discussion of planned improvements to the LDV is also included.

Podboy, Gary G.↗

The Mars Orbiter Laser Altimeter Archive: Final Precision Experiment Data Record Release and Status of Radiometry

A final release (Version L) of the Mars Orbiter Laser Altimeter (MOLA) Precision Experiment Data Record (PEDR) has been submitted to the Planetary Data System (PDS). Additional gridded data record products are forthcoming. These products have evolved since their original description, owing in part to improved gravity modeling and cartographic reference frames, and in part to refinements in calibration. An additional component, the 1064 nm narrowband radiometry data, is also being archived. These data will be invaluable for future studies by Mars explorers and scientists.

Neumann, Gregory A.↗

Liquid-metal-fed Pulsed Plasma Thrusters for In-space Propulsion

Liquid metal propellants may provide a path toward more reliable and efficient pulsed plasma thrusters (PPTs). Conceptual thruster designs which eliminate the need for high current switches and propellant metering valves are described. Propellant loading techniques are suggested that show promise to increase thruster propellant utilization, dynamic, and electrical efficiency. Calibration results from a compact, electromagnetically-pumped propellant feed system are presented. Results for lithium and gallium propellants show capability to meter propellant at flow rates up to 10 +/- 0.1 mg/s. Experiments investigating the initiation of arc discharges using liquid metal droplets are presented. High speed photography and laser interferometry provide spatially and temporally resolved information on the decomposition of liquid metal droplets , and the evolution of the accelerating current channel.

Markusic, Thomas E.↗

Ge's Mobile, Coherent Doppler Lidar Test/Ealuation Facilities

The primary objective of this independent research and development (IR and D) program in support of the Laser Atmospheric Wind Sounder (LAWS) program is to develop and evaluate technologies with direct applications to spaceborne laser wind sensing, and to develop system level engineering experience in designing, operating, and modeling a coherent Doppler lidar. GE is developing a mobile, ground based coherent Doppler lidar as an end-to-end system level test facility to evaluate applicable technologies, verify system level performance issues, perform instrument calibration, and validate end-to-end system performance model predictions. Here, the primary focus is on a description of the ground based lidar system and the performance during the initial shakedown operation after system integration.

Sroga, J. T.↗

Application of an On-machine Gage for Diameter Measurements

This paper describes the design analysis and application of a laser based gage made specifically for measuring parts on the machine tool to a high accuracy. The tri-beam gage uses three beams of light to measure the local curvature of the part in a manner similar to a V-block gage. The properties of this design include: calibration that is independent of the machine tool scales, non-contact damage free operation, low cost of the gage, and the ability to measure parts in motion.

Harding, Kevin G.↗

Doppler global velocimetry: Development of a flight research instrumentation system for application to non-intrusive measurements of the flow field

Doppler Global Velocimetry (DGV) is a new diagnostic tool that offers potential for flow field measurements in flight by acquiring three-component velocity data in near real-time during flight maneuvers. The feasibility of implementation of a flight DGV system aboard NASA's High-Angle-of-Attack Research Vehicle (HARV) was addressed in this work by identifying the essential characteristics of a flight measurement system and by performing calibration and error tests. Results from this work were: an outline that establishes a preliminary basis for system configurations by analyzing measurement errors, installation issues, and operating requirements; measurement of the accuracy of the DGV technique using a laboratory breadboard DGV system based on a frequency-doubled Nd: YAG laser and iodine Absorption Line Filter (ALF), which showed excellent agreement between the DGV data and pilot measurements on a laminar flow jet with velocities of up to 150 m/sec; a survey of DGV system components and technologies that are relevant to the design of a flight measurement system, including a survey of cameras for the next generation DGV receivers; an assessment of the candidate lasers and absorption line filters for the flight system, resulting in a near-term recommendation of Nd: host lasers and an iodine ALF for both flight and wind tunnel applications.

Komine, Hiroshi↗

Laser induced fluorescence measurements and modeling of nitric oxide in high-pressure premixed flames

Laser-induced fluorescence (LIF) has been applied to the quantitative measurement of nitric oxide (NO) in premixed, laminar, high-pressure flames. Their chemistry was also studied using three current kinetics schemes to determine the predictive capabilities of each mechanism with respect to NO concentrations. The flames studied were low-temperature (1600 less than T less than 1850K) C2H6/O2/N2 and C2H6/O2/N2 flames, and high temperature (2100 less than T less than 2300K) C2H6/O2/N2 flames. Laser-saturated fluorescence (LSF) was initially used to measure the NO concentrations. However, while the excitation transition was well saturated at atmospheric pressure, the fluorescence behavior was basically linear with respect to laser power at pressures above 6 atm. Measurements and calculations demonstrated that the fluorescence quenching rate variation is negligible for LIF measurements of NO at a given pressure. Therefore, linear LIF was used to perform quantitative measurements of NO concentration in these high-pressure flames. The transportability of a calibration factor from one set of flame conditions to another also was investigated by considering changes in the absorption and quenching environment for different flame conditions. The feasibility of performing LIF measurements of (NO) in turbulent flames was studied; the single-shot detection limit was determined to be 2 ppm.

Reisel, John R.↗

Poster Presentation: Optical Test of NGST Developmental Mirrors

An Optical Testing System (OTS) has been developed to measure the figure and radius of curvature of NGST developmental mirrors in the vacuum, cryogenic environment of the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The OTS consists of a WaveScope Shack-Hartmann sensor from Adaptive Optics Associates as the main instrument, a Point Diffraction Interferometer (PDI), a Point Spread Function (PSF) imager, an alignment system, a Leica Disto Pro distance measurement instrument, and a laser source palette (632.8 nm wavelength) that is fiber-coupled to the sensor instruments. All of the instruments except the laser source palette are located on a single breadboard known as the Wavefront Sensor Pallet (WSP). The WSP is located on top of a 5-DOF motion system located at the center of curvature of the test mirror. Two PC's are used to control the OTS. The error in the figure measurement is dominated by the WaveScope's measurement error. An analysis using the absolute wavefront gradient error of 1/50 wave P-V (at 0.6328 microns) provided by the manufacturer leads to a total surface figure measurement error of approximately 1/100 wave rms. This easily meets the requirement of 1/10 wave P-V. The error in radius of curvature is dominated by the Leica's absolute measurement error of VI.5 mm and the focus setting error of Vi.4 mm, giving an overall error of V2 mm. The OTS is currently being used to test the NGST Mirror System Demonstrators (NMSD's) and the Subscale Beryllium Mirror Demonstrator (SBNM).

Hadaway, James B.↗

Laser Time-of-Flight Mass Spectrometry for Space

A miniature reflection time-of-flight mass spectrometer for in situ planetary surface analysis is described. The laser ablation mass spectrometer (LAMS) measures the regolith's elemental and isotopic composition without high-voltage source extraction or sample preparation. The compact size (< 2 x 10(exp 3) cubic cm) and low mass (approximately 2 kg) of LAMS, due to its fully coaxial design and two-stage reflectron, fall within the strict resource limitations of landed science missions to solar system bodies. A short-pulse laser focused to a spot with a diameter approximately 30-50 micrometers is used to obtain microscopic surface samples. Assisted by a microimager, LAMS can interactively select and analyze a range of compositional regions (with lateral motion) and with repeated pulses can access unweathered, subsurface materials. The mass resolution is calibrated to distinguish isotopic peaks at unit masses, and detection limits are on resolved to a few ppm. The design and calibration method of a prototype LAMS device is described, which include the development of preliminary relative sensitivity coefficients for major element bulk abundance measurements.

Brinckerhoff, W. B.↗

AWP: NASA's Aerosol Wind Profiler Coherent Doppler Wind Lidar

A new airborne coherent Doppler Wind Lidar (DWL) instrument has been implemented leveraging NASA's development of the 2-micron Wind-Space Pathfinder (Wind-SP) lidar transceiver. A technology development project, Wind-SP refined and demonstrated numerous components required for a coherent-detection space wind lidar instrument. Aerosol Wind Profiler (AWP) transitioned this transceiver into an airborne wind lidar capable of providing full 3-D wind vector retrievals. AWP operates with laser pulse energy and repetition rate combination required for high spatial and vertical resolution wind profiling from space. Operation from aircraft platforms will yield very strong signal return required for detailed process studies at <2km spatial and <100m vertical resolution under most conditions. AWP will serve as NASA’s wind calibration and validation instrument for future space-based wind observations over the coming decades, while also providing data supporting space wind lidar simulation studies. The AWP instrument is introduced and preliminary results from recent AWP demonstration flights are presented.

AWP↗

Fiber optic and laser sensors IV; Proceedings of the Meeting, Cambridge, MA, Sept. 22-24, 1986

The conference presents papers on industrial uses of fiber optic sensors, point and distributed polarimetric optical fiber sensors, fiber optic electric field sensor technology, micromachined resonant structures, single-mode fibers for sensing applications, and measurement techniques for magnetic field gradient detection. Consideration is also given to electric field meter and temperature measurement techniques for the power industry, the calibration of high-temperature fiber-optic microbend pressure transducers, and interferometric sensors for dc measurands. Other topics include the recognition of colors and collision avoidance in robotics using optical fiber sensors, the loss compensation of intensity-modulating fiber-optic sensors, and an embedded optical fiber strain tensor for composite structure applications.

De Paula, Ramon P.↗

The Fiber Optic System for the Advanced Topographic Laser Altimeter System (ATLAS) Instrument

The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm. The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.

global climate changes↗

Experimental and analytical study of cryogenic propellant boiloff to develop and verify alternate pressurization concepts for Space Shuttle external tank using a scaled down tank

Self pressurization by propellant boiloff is experimentally studied as an alternate pressurization concept for the Space Shuttle external tank (ET). The experimental setup used in the study is an open flow system which is composed of a variable area test tank and a recovery tank. The vacuum jacketed test tank is geometrically similar to the external LOx tank for the Space Shuttle. It is equipped with instrumentation to measure the temperature and pressure histories within the liquid and vapor, and viewports to accommodate visual observations and Laser-Doppler Anemometry measurements of fluid velocities. A set of experiments were conducted using liquid Nitrogen to determine the temperature stratification in the liquid and vapor, and pressure histories of the vapor during sudden and continuous depressurization for various different boundary and initial conditions. The study also includes the development and calibration of a computer model to simulate the experiments. This model is a one-dimensional, multi-node type which assumes the liquid and the vapor to be under non-equilibrium conditions during the depressurization. It has been tested for a limited number of cases. The preliminary results indicate that the accuracy of the simulations is determined by the accuracy of the heat transfer coefficients for the vapor and the liquid at the interface which are taken to be the calibration parameters in the present model.

Akyuzlu, K. M.↗

High-degree Gravity Models from GRAIL Primary Mission Data

We have analyzed Ka‒band range rate (KBRR) and Deep Space Network (DSN) data from the Gravity Recovery and Interior Laboratory (GRAIL) primary mission (1 March to 29 May 2012) to derive gravity models of the Moon to degree 420, 540, and 660 in spherical harmonics. For these models, GRGM420A, GRGM540A, and GRGM660PRIM, a Kaula constraint was applied only beyond degree 330. Variance‒component estimation (VCE) was used to adjust the a priori weights and obtain a calibrated error covariance. The global root‒mean‒square error in the gravity anomalies computed from the error covariance to 320×320 is 0.77 mGal, compared to 29.0 mGal with the pre‒GRAIL model derived with the SELENE mission data, SGM150J, only to 140×140. The global correlations with the Lunar Orbiter Laser Altimeter‒derived topography are larger than 0.985 between l = 120 and 330. The free‒air gravity anomalies, especially over the lunar farside, display a dramatic increase in detail compared to the pre‒GRAIL models (SGM150J and LP150Q) and, through degree 320, are free of the orbit‒track‒related artifacts present in the earlier models. For GRAIL, we obtain an a posteriori fit to the S‒band DSN data of 0.13 mm/s. The a posteriori fits to the KBRR data range from 0.08 to 1.5 micrometers/s for GRGM420A and from 0.03 to 0.06 micrometers/s for GRGM660PRIM. Using the GRAIL data, we obtain solutions for the degree 2 Love numbers, k20=0.024615+/-0.0000914, k21=0.023915+/-0.0000132, and k22=0.024852+/-0.0000167, and a preliminary solution for the k30 Love number of k30=0.00734+/-0.0015, where the Love number error sigmas are those obtained with VCE.

Primary 1↗

Comparison of the frequencies of NH3, CO2, H2O, N2O, CO, and CH4 as infrared calibration standards

The absolute accuracies of infrared calibration standards for the line positions have been investigated using a 0.0056-kayser-resolution (unapodized) Fourier-transform spectrum recorded from 550 to 5000 kayser. The spectrum has been obtained using a multicell arrangement containing the various molecular species. Detailed comoparisons reveal that standards for CO2, CH4, and N2O obtained from laser research and NH3 from Fourier-transform spectrometer research are consistent within the accuracies of the present data (+ or 0.0001 kayser). However, certain N2O, H2O, and CO values in the 1100-to 2300 kayser region are systematically high by 0.0001 to 0.0004 kayser. Correction factors for the H2O and CO standards are obtained to bring these into agreement with the laser values. In addition, corrected values for the 2nu-2 and nu-1 bands of N2O at 9 microns are reported.

Brown, L. R.↗

Uncertainties in hot-wire measurements of compressible turbulent flows implied by comparisons with laser-induced fluorescence

A hot-wire anemometer and a new nonintrusive laser-induced fluorescence (LIF) technique are used to survey a Mach 2 turbulent boundary layer. The hot-wire anemometer's ability to accurately measure mass flux, temperature, and density fluctuations in a compressible flow is examined by comparing its results with those obtained using LIF. Several methods of hot-wire calibration are used, and the uncertainties in their measurements of various fluctuating flow parameters are determined. The results show that although a hot-wire operated at high overheat can measure mass flux fluctuations, temperature and density fluctuations are not determined accurately from such measurements. However, a hot-wire operated at multiple overheats can be used to measure static and total temperature fluctuations. The presence of pressure fluctuations and their correlation with density can prevent the use of hot-wire data to determine density fluctuations.

Mckenzie, R. L.↗