Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Vibration control in accelerators

In the vast majority of accelerator applications, ground vibration amplitudes are well below tolerable magnet jitter amplitudes. In these cases, it is necessary and sufficient to design a rigid magnet support structure that does not amplify ground vibration. Since accelerator beam lines are typically installed at an elevation of 1-2m above ground level, special care has to be taken in order to avoid designing a support structure that acts like an inverted pendulum with a low resonance frequency, resulting in untolerable lateral vibration amplitudes of the accelerator components when excited by either ambient ground motion or vibration sources within the accelerator itself, such as cooling water pumps or helium flow in superconducting magnets. In cases where ground motion amplitudes already exceed the required jiter tolerances, for instance in future linear colliders, passive vibration damping or active stabilization may be considered.

43 PARTICLE ACCELERATORS↗

Dosimetry of an In-Line Kilovoltage Imaging System and Implementation in Treatment Planning

Purpose: To present the beam properties of the Siemens 70-kV and 121-kV linear accelerator-mounted imaging modalities and commissioning of the 121-kV beam in the Philips Pinnacle treatment planning system (TPS); measurements in an Alderson phantom were performed for verification of the model and to estimate the cone-beam CT (CBCT) imaging dose in the head and neck, thorax, and pelvis. Methods and Materials: The beam profiles and depth–dose curve were measured in an acrylic phantom using thermoluminescent dosimeters and a soft x-ray ionization chamber. Measurements were imported into the TPS, modeled, and verified by phantom measurements. Results: Modeling of the profiles and the depth–dose curve can be achieved with good quality. Comparison with the measurements in the Alderson phantom is generally good; only very close to bony structures is the dose underestimated by the TPS. For a 200° arc CBCT of the head and neck, a maximum dose of 7 mGy is measured; the thorax and pelvis 360° CBCTs give doses of 4-10 mGy and 7-15 mGy, respectively. Conclusions: Dosimetric characteristics of the Siemens kVision imaging modalities are presented and modeled in the Pinnacle TPS. Thermoluminescent dosimeter measurements in the Alderson phantom agree well with the calculated TPS dose, validating the model and providing an estimate of the imaging dose for different protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A stochastic perturbation method to generate inflow turbulence in large-eddy simulation models: Application to neutrally stratified atmospheric boundary layers

Despite the variety of existing methods, efficient generation of turbulent inflow conditions for large-eddy simulation (LES) models remains a challenging and active research area. Herein, we extend our previous research on the cell perturbation method, which uses a novel stochastic approach based upon finite amplitude perturbations of the potential temperature field applied within a region near the inflow boundaries of the LES domain [Muñoz-Esparza et al., “Bridging the transition from mesoscale to microscale turbulence in numerical weather prediction models,” Boundary-Layer Meteorol., 153, 409–440 (2014)]. The objective was twofold: (i) to identify the governing parameters of the method and their optimum values and (ii) to generalize the results over a broad range of atmospheric large-scale forcing conditions, U{sub g} = 5 − 25 m s{sup −1}, where U{sub g} is the geostrophic wind. We identified the perturbation Eckert number, Ec=U{sub g}{sup 2}/ρc{sub p}θ{sup ~}{sub pm}, to be the parameter governing the flow transition to turbulence in neutrally stratified boundary layers. Here, θ{sup ~}{sub pm} is the maximum perturbation amplitude applied, c{sub p} is the specific heat capacity at constant pressure, and ρ is the density. The optimal Eckert number was found for nonlinear perturbations allowed by Ec ≈ 0.16, which instigate formation of hairpin-like vortices that most rapidly transition to a developed turbulent state. Larger Ec numbers (linear small-amplitude perturbations) result in streaky structures requiring larger fetches to reach the quasi-equilibrium solution, while smaller Ec numbers lead to buoyancy dominated perturbations exhibiting difficulties for hairpin-like vortices to emerge. Cell perturbations with wavelengths within the inertial range of three-dimensional turbulence achieved identical quasi-equilibrium values of resolved turbulent kinetic energy, q, and Reynolds-shear stress, . In contrast, large-scale perturbations acting at the production range exhibited reduced levels of , due to the formation of coherent streamwise structures, while q was maintained, requiring larger fetches for the turbulent solution to stabilize. Additionally, the cell perturbation method was compared to a synthetic turbulence generator. The proposed stochastic approach provided at least the same efficiency in developing realistic turbulence, while accelerating the formation of large-scales associated with production of turbulent kinetic energy. Also, it is computationally inexpensive and does not require any turbulent information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Acceleration of Biexciton Radiative Recombination at Low Temperature in CdSe Nanoplatelets

Colloidal semiconductor nanocrystals offer bandgap tunability, high photoluminescence quantum yield, and colloidal processing of benefit to optoelectronics, however rapid nonradiative Auger recombination (AR) deleteriously affects device efficiencies at elevated excitation intensities. AR is understood to transition from temperature-dependent behavior in bulk semiconductors to temperature-independent behavior in zero-dimensional quantum dots (QDs) as a result of discretized band structure that facilitates satisfaction of linear momentum conservation. For nanoplatelets (NPLs), two-dimensional morphology renders prediction of photophysical behaviors challenging. Here, in this study, we investigate and compare the temperature dependence of excited-stated lifetime and fluence-dependent emission of CdSe NPLs and QDs. For NPLs, upon temperature reduction, biexciton lifetime surprisingly decreases (even becoming shorter lived than trion emission) and emission intensity increases nearly linearly with fluence rather than saturating, consistent with dominance of radiative recombination rather than AR. CdSe NPLs thus differ fundamentally from core-only QDs and foster increased utility of photogenerated excitons and multiexcitons at low temperatures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-152: Error Sensitivity and Superiority of a Protocol for 3D IMRT Quality Assurance

Purpose: To test if the parameters included in our 3D QA protocol with current tolerance levels are able to detect certain errors and show the superiority of 3D QA method over single ion chamber measurements and 2D gamma test by detecting most of the introduced errors. The 3D QA protocol parameters are: TPS and measured average dose difference, 3D gamma test with 3mmDTA/3% test parameters, and structure volume for which the TPS predicted and measured absolute dose difference is greater than 6%. Methods: Two prostate and two thoracic step-and-shoot IMRT patients were investigated. The following errors were introduced to each original treatment plan: energy switched from 6MV to 10MV, linac jaws retracted to 15cmx15cm, 1,2,3 central MLC leaf pairs retracted behind the jaws, single central MLC leaf put in or out of the treatment field, Monitor Units (MU) increased and decreased by 1 and 3%, collimator off by 5 and 15 degrees, detector shifted by 5mm to the left and right, gantry treatment angle off by 5 and 15 degrees. QA was performed on each plan using single ion chamber, 2D ion chamber array for 2D gamma analysis and using IBA's COMPASS system for 3D QA. Results: Out of the three tested QA methods single ion chamber performs the worst not detecting subtle errors. 3D QA proves to be the superior out of the three methods detecting all of introduced errors, except 10MV and 1% MU change, and MLC rotated (those errors were not detected by any QA methods tested). Conclusion: As the way radiation is delivered evolves, so must the QA. We believe a diverse set of 3D statistical parameters applied both to OAR and target plan structures provides the highest level of QA.

07 ISOTOPE AND RADIATION SOURCES↗

Photon Science at Modern Light Sources

More than 50 large x-ray and UV light sources based on high-energy electron accelerators are in operation around the world, serving a scientific community numbering in the tens of thousands. These sources generate synchrotron radiation from accelerated electrons or positrons. The development of synchrotron light sources over the last 40 years has fueled an exponential increase in x-ray source brightness of more than 10 orders of magnitude. The next large advance in source potential is now underway, with the commissioning of the first x-ray Free-Electron Laser (FEL) sources. Using high-energy electron linear accelerators, these facilities produce sub-picosecond pulses of hard x-rays with peak brightness more than 10 orders of magnitude greater than current synchrotron facilities. FEL x-ray facilities will soon be operational in the US, Japan, and Germany.Research at modern light sources makes use of a wide range of experimental techniques. Many experiments are designed to study the structure of matter at the atomic scale using elastic x-ray scattering. This technique has been particularly effective for determining the structures of biological molecules, such as proteins, viruses, and drugs. Inelastic x-ray scattering, or x-ray absorption followed by emission of electrons or photons, can give information about the electronic structures of atoms, which can be used to deduce local environment information such as atomic species, bonding state, geometry of neighboring atoms, or magnetic state. For some techniques involving x-ray emission from a sample, cryogenic detectors with energy resolution at the {approx}10 eV level or better would be very helpful. Shifts in electron energy levels associated with bonding states and magnetic states are typically several eV, while the energy structure associated with Compton inelastic scattering is typically in the range of a few tens of eV. Current energy-resolving detectors used at synchrotron light sources are hampered by either poor energy resolution ({approx}100 eV for solid state detectors), or very poor angular acceptance (10{sup -3} sr or worse for grating and crystal analyzer detectors).Photon detectors at synchrotron light sources can be presented with very high signal count rates. At the new FEL sources, this issue will be especially acute, since each sub-picosecond pulse will deliver the flux produced in one second by a synchrotron. This invites the use of multiple small detectors to spread the load. The ideal energy-resolving detector for x-ray science at modern light sources would combine eV-level energy resolution, 100-{mu}m pixel size, and a low per-pixel cost allowing several megapixels to be deployed.

74 ATOMIC AND MOLECULAR PHYSICS↗

GEANT4 Application for the Simulation of the Head of a Siemens Primus Linac

The Monte Carlo simulation of the head of a Siemens Primus Linac used at Virgen Macarena Hospital (Sevilla, Spain) has been performed using the code GEANT4, version 9.2. In this work, the main features of the application built by our group are presented. They are mainly focused in the optimization of the performance of the simulation. The geometry, including the water phantom, has been entirely wrapped by a shielding volume which discards all the particles escaping far away through its walls. With this, a factor of four in the time spent by the simulation can be saved. An interface to read and write phase-space files in IAEA format has been also developed to save CPU time in our simulations. Finally, some calculations of the dose absorption in the water phantom have been done and compared with the results given by EGSnrc and with experimental data obtained for the calibration of the machine.

43 PARTICLE ACCELERATORS↗

Shielded Heavy-Ion Environment Linear Detector (SHIELD): an experiment for the Radiation and Technology Demonstration (RTD) Mission

Radiological assessment of the many cosmic ion species of widely distributed energies requires the use of theoretical transport models to accurately describe diverse physical processes related to nuclear reactions in spacecraft structures, planetary atmospheres and surfaces, and tissues. Heavy-ion transport models that were designed to characterize shielded radiation fields have been validated through comparison with data from thick-target irradiation experiments at particle accelerators. With the RTD Mission comes a unique opportunity to validate existing radiation transport models and guide the development of tools for shield design. For the first time, transport properties will be measured in free-space to characterize the shielding effectiveness of materials that are likely to be aboard interplanetary space missions. Target materials composed of aluminum, advanced composite spacecraft structure and other shielding materials, helium (a propellant) and tissue equivalent matrices will be evaluated. Large solid state detectors will provide kinetic energy and charge identification for incident heavy-ions and for secondary ions created in the target material. Transport calculations using the HZETRN model suggest that 8 g cm -2 thick targets would be adequate to evaluate the shielding effectiveness during solar minimum activity conditions for a period of 30 days or more.

NASA Center LaRC↗

Ultrasonic-Assisted Extrusion Processing for Enhancing Physical Properties of High-Density Polyethylene by Flow-Induced Crystallization

The evolution of crystallinity resulting from stress imposed on a melt, known as flow-induced crystallinity, can strongly influence the mechanical and physical properties of semicrystalline polymers. This study investigates shear-induced crystallization by applying an ultrasonic field to the melt flow as it passes through dies with various geometries. A custom-built sonication die is employed for controlling the dynamic temperature and shear environment, resulting in molecular alignment and potential for flow-induced crystallization. Application of both conventional and ultrasonic shear rates at the equilibrium melt temperature of high-density polyethylene (HDPE) was investigated to accelerate crystallinity and manipulate the crystal morphology across the film in pursuit of improved mechanical and gas barrier properties without the need for additives or other polymer layers. The relationships among ultrasonic-assisted extrusion processing, polymer structure, and performance were analyzed using wide- and small-angle X-ray scattering (WAXS and SAXS), tensile testing, and oxygen transmission rate (OTR) analysis. Multiple linear regression models were implemented to predict the correlation among HDPE structure, process, and properties. Structural analysis revealed that both conventional and ultrasonic shear rates had the most significant influence on lamellar spacing and redistribution of rigid and soft amorphous fractions within the crystalline domains, ultimately dictating the mechanical and physical properties of the films. The goal is to explore the potential of the ultrasonic-assisted high crystallinity monolayer that can replace some of the functionality of complex, heterogeneous multilayer packaging with a single-material film having enhanced oxygen barrier properties.

crystallinity↗

THERMOHALINE INSTABILITIES INSIDE STARS: A SYNTHETIC STUDY INCLUDING EXTERNAL TURBULENCE AND RADIATIVE LEVITATION

We have derived a new expression for the thermohaline mixing coefficient in stars, including the effects of radiative levitation and external turbulence, by solving Boussinesq equations in a nearly incompressible stratified fluid with a linear approximation. It is well known that radiative levitation of individual elements can lead to their accumulation in specific stellar layers. In some cases, it can induce important effects on the stellar structure. Here we confirm that this accumulation is moderated by thermohaline convection due to the resulting inverse {mu}-gradient. The new coefficient that we have derived shows that the effect of radiative accelerations on the thermohaline instability itself is small. This effect must however be checked in all computations. We also confirm that the presence of large horizontal turbulence can reduce or even suppress the thermohaline convection. These results are important as they concern all the cases of heavy element accumulation in stars. Computations of radiative diffusion must be revisited to include thermohaline convection and its consequences. It may be one of the basic reasons for the fact that the observed abundances are always smaller than those predicted by pure atomic diffusion. In any case, these processes have to compete with rotation-induced mixing, but this competition is more complex than previously thought due to their mutual interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of D{sub sJ} decays to D*K in inclusive e{sup +}e{sup -} interactions

We observe the decays D{sub s1}*(2710){sup +}{yields}D*K and D{sub sJ}*(2860){sup +}{yields}D*K and measure their branching fractions relative to the DK final state. We also observe, in the D*K mass spectrum, a new broad structure at a mass of (3044{+-}8{sub stat}((+30/-5)){sub syst}) MeV/c{sup 2} having a width {gamma}=(239{+-}35{sub stat}((+46/-42)){sub syst}) MeV. To obtain this result we use 470 fb{sup -1} of data recorded by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} storage rings at the Stanford Linear Accelerator Center running at center-of-mass energies near 10.6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of D_s J decays to D*K in inclusive e+e- interactions

We observe the decays D*{sub s1} (2710){sup +} {yields} D*K and D*{sub sJ} (2860){sup +} {yields} D*K and measure their branching fractions relative to the DK final state. We also observe, in the D*K mass spectrum, a new broad structure at a mass of (3044 {+-} 8{sub stat}(+30/-5){sub syst}) MeV/c{sup 2} having a width {Lambda} = (239 {+-} 35{sub stat}(+46/-42){sub syst}) MeV. To obtain this result we use 470 fb{sup -1} of data recorded by the BABAR detector at the PEP-II asymmetric-energy e{sup +}e{sup -} storage rings at the Stanford Linear Accelerator Center running at center-of-mass energies near 10.6 GeV.

43 PARTICLE ACCELERATORS↗

Dispersion in the Presence of Strong Transverse Wakefields

To minimize emittance growth in a long linac, it is necessary to control the wakefields by correcting the beam orbit excursions. In addition, the particle energy is made to vary along the length of the bunch to introduce a damping, known as the BNS damping, to the beam break-up effect. In this paper, we use a two-particle model to examine the relative magnitudes of the various orbit and dispersion functions involved. The results are applied to calculate the effect of a closed orbit bump and a misaligned structure. It is shown that wake-induced dispersion is an important contribution to the beam dynamics in long linacs with strong wakefields like SLC.

43 PARTICLE ACCELERATORS↗

Monitoring of dielectric permittivity in accelerated alkali-silica reaction concrete with microwave backscattering

Deterioration of concrete due to the alkali–silica reaction (ASR) involves a reaction between alkaline ions in the cement pore solution and non-crystalline silica found in many aggregates. The product of reaction is a porous hydrophilic ASR gel, which causes expansion and cracking of concrete structure. Currently, there is no reliable method for non-destructive evaluation of ASR. We have investigated the feasibility of using relative dielectric permittivity obtained from X-band microwave backscattering of concrete. Advantages of this method of concrete evaluation are that measurements are non-contact and one-sided, and the approach is scalable to arbitrary-size concrete structures. The exploratory study was performed using an unrestrained set of accelerated ASR concrete prism specimens developed according to the ASTM1293 standard. One set of specimens contained no entrained air, while another set was contained entrained air. The specimens were removed from the environmental chamber at different times during a year-long study to create a set of different ASR maturity specimens. Strain measurements were performed on all specimens. Strain data both air entrained and non-air entrained sets were shown to be in close agreement with Larive model of isothermal unrestrained ASR expansion with similar fitting parameters. Furthermore, relative dielectric permittivity of concrete specimens was correlated with strain data. Both sets show correlation between dielectric permittivity and strain, with stronger linear correlation observed for the air-entrained specimens. Development of such correlation would enable estimating expansion of actual concrete structures from microwave backscattering measurements, which could be used for risk stratification to guide and minimize coring.

36 MATERIALS SCIENCE↗

Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy

Purpose: To develop an efficient and robust tool for output measurement and absolute dose verification of electron beam therapy by using a high spatial-resolution and high frame-rate amorphous silicon flat panel electronic portal imaging device (EPID). Methods: The dosimetric characteristics of the EPID, including saturation, linearity, and ghosting effect, were first investigated on a Varian Clinac 21EX accelerator. The response kernels of the individual pixels of the EPID to all available electron energies (6, 9, 12, 16, and 20 MeV) were calculated by using Monte Carlo (MC) simulations, which formed the basis to deconvolve an EPID raw images to the incident electron fluence map. The two-dimensional (2D) dose distribution at reference depths in water was obtained by using the constructed fluence map with a MC simulated pencil beam kernel with consideration of the geometric and structural information of the EPID. Output factor measurements were carried out with the EPID at a nominal source–surface distance of 100 cm for 2 × 2, 3 × 3, 6 × 6, 10 × 10, and 15 × 15 cm{sup 2} fields for all available electron energies, and the results were compared with that measured in a solid water phantom using film and a Farmer-type ion chamber. The dose distributions at a reference depth specific to each energy and the flatness and symmetry of the 10 × 10 cm{sup 2} electron beam were also measured using EPID, and the results were compared with ion chamber array and water scan measurements. Finally, three patient cases with various field sizes and irregular cutout shapes were also investigated. Results: EPID-measured dose changed linearly with the monitor units and showed little ghosting effect for dose rate up to 600 MU/min. The flatness and symmetry measured with the EPID were found to be consistent with ion chamber array and water scan measurements. The EPID-measured output factors for standard square fields of 2 × 2, 3 × 3, 6 × 6, 10 × 10, 15 × 15 cm{sup 2} agreed with film and ion chamber measurements. The average discrepancy between EPID and ion chamber/film measurements was 0.81% ± 0.60% (SD) and 1.34% ± 0.75%, respectively. For the three clinical cases, the difference in output between the EPID- and ion chamber array measured values was found to be 1.13% ± 0.11%, 0.54% ± 0.10%, and 0.74% ± 0.11%, respectively. Furthermore, the γ-index analysis showed an excellent agreement between the EPID- and ion chamber array measured dose distributions: 100% of the pixels passed the criteria of 3%/3 mm. When the γ-index was set to be 2%/2 mm, the pass rate was found to be 99.0% ± 0.07%, 98.2% ± 0.14%, and 100% for the three cases. Conclusions: The EPID dosimetry system developed in this work provides an accurate and reliable tool for routine output measurement and dosimetric verification of electron beam therapy. Coupled with its portability and ease of use, the proposed system promises to replace the current film-based approach for fast and reliable assessment of small and irregular electron field dosimetry.

60 APPLIED LIFE SCIENCES↗

The Orthorhomic Structure of CaCo[subscript 3], SrCO[subscript 3], PbCO[subscript 3] and BaCO[subscript 3]: Linear Structural Trends

The crystal structures of four isostructural orthorhombic carbonates, CaCO{sub 3} (aragonite), SrCO{sub 3} (strontianite), PbCO{sub 3} (cerussite), and BaCO{sub 3} (witherite), were obtained by Rietveld refinements using data acquired by synchrotron high-resolution powder X-ray diffraction (HRPXRD). For BaCO{sub 3}, powder neutron-diffraction data were obtained and refined by the Rietveld method. For aragonite, we also carried out a refinement of the structure by single-crystal X-ray diffraction. These carbonates belong to the space group Pmcn, with Z = 4. The CO{sub 3} group is slightly non-planar, and the two independent C-O distances are slightly different. The CO{sub 3} group becomes more symmetrical and less aplanar from CaCO{sub 3} to BaCO{sub 3} (M{sub radii}{sup 2+}: Ca < Sr < Pb < Ba). The CaCO{sub 3} structure is, therefore, the most distorted, whereas the BaCO{sub 3} structure is the least distorted. Several linear structural trends are observed in plots of selected parameters as a function of the unit-cell volume, V. These parameters are radii of the nine-coordinated M{sup 2+} cations, the unit-cell axes, the average <M-O> and <C-O> distances, average <O-C-O> angle, and aplanarity. These linear trends are the result of the effective size of the divalent ionic radius of the M cations that are coordinated to nine oxygen atoms. The geometrical features of the CO{sub 3} group can be obtained reliably only by using neutron-diffraction data, especially in the presence of other heavy atoms.

36 MATERIALS SCIENCE↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Laser damage threshold measurements of optical materials for direct laser accelerators

The laser-damage threshold is a fundamental limit for any dielectric laser-driven accelerator and is set by the material of the structure. In this paper, we present a theoretical model of the laser damage mechanism, in comparison with experimental data on the damage threshold of silicon. Additionally, we present damage threshold measurement data of various optical materials, most of which have not been previously characterized in the picosecond-regime.

36 MATERIALS SCIENCE↗