Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC GUIDE FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Three-dimensional nonlinear efficiency enhancement analysis in free-electron laser amplifier with prebunched electron beam and ion-channel guiding

Efficiency enhancement in free-electron laser is studied by three-dimensional and nonlinear simulation using tapered helical wiggler magnetic field or tapered ion-channel density. In order to reduce the saturation length, prebunched electron beam is used. A set of nonlinear and coupled differential equations are derived that provides the self-consistent description of the evolution of both an ensemble of electrons and the electromagnetic radiation. These equations are solved numerically to show that the combined effect of tapering and prebunching results in significant enhancement of power and considerable reduction of the saturation length. To have a deeper insight into the problem, an analytical treatment is also presented that uses the small signal theory to derive a modified pendulum equation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-AB-BRA-09: Stability Analysis of a Novel Dose Calculation Algorithm for MRI Guided Radiotherapy

Purpose: To determine the iterative deterministic solution stability of the Linear Boltzmann Transport Equation (LBTE) in the presence of magnetic fields. Methods: The LBTE with magnetic fields under investigation is derived using a discrete ordinates approach. The stability analysis is performed using analytical and numerical methods. Analytically, the spectral Fourier analysis is used to obtain the convergence rate of the source iteration procedures based on finding the largest eigenvalue of the iterative operator. This eigenvalue is a function of relevant physical parameters, such as magnetic field strength and material properties, and provides essential information about the domain of applicability required for clinically optimal parameter selection and maximum speed of convergence. The analytical results are reinforced by numerical simulations performed using the same discrete ordinates method in angle, and a discontinuous finite element spatial approach. Results: The spectral radius for the source iteration technique of the time independent transport equation with isotropic and anisotropic scattering centers inside infinite 3D medium is equal to the ratio of differential and total cross sections. The result is confirmed numerically by solving LBTE and is in full agreement with previously published results. The addition of magnetic field reveals that the convergence becomes dependent on the strength of magnetic field, the energy group discretization, and the order of anisotropic expansion. Conclusion: The source iteration technique for solving the LBTE with magnetic fields with the discrete ordinates method leads to divergent solutions in the limiting cases of small energy discretizations and high magnetic field strengths. Future investigations into non-stationary Krylov subspace techniques as an iterative solver will be performed as this has been shown to produce greater stability than source iteration. Furthermore, a stability analysis of a discontinuous finite element space-angle approach (which has been shown to provide the greatest stability) will also be investigated. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stimulus-response incompatibility activates cortex proximate to three eye fields

We used functional magnetic resonance imaging (fMRI) to investigate cortical activation during the performance of three oculomotor tasks that impose increasing levels of cognitive demand. (1) In a visually guided saccade (VGS) task, subjects made saccades to flashed targets. (2) In a compatible task, subjects made leftward and rightward saccades in response to foveal presentation of the uppercase words "LEFT" or "RIGHT." (3) In a mixed task, subjects made rightward saccades in response to the lowercase word "left" and leftward saccades in response to the lowercase word "right" on incompatible trials (60%). The remaining 40% of trials required compatible responses to uppercase words. The VGS and compatible tasks, when compared to fixation, activated the three cortical eye fields: the supplementary eye field (SEF), the frontal eye field (FEF), and the parietal eye field (PEF). The mixed task, when compared to the compatible task, activated three additional cortical regions proximate to the three eye fields: (1) rostral to the SEF in medial frontal cortex; (2) rostral to the FEF in dorsolateral prefrontal cortex (DLPFC); (3) rostral and lateral to the PEF in posterior parietal cortex. These areas may contribute to the suppression of prepotent responses and in holding novel visuomotor associations in working memory. Copyright 2001 Academic Press.

NASA Discipline Neuroscience↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic electron focusing and tuning of the electron current with a pn-junction

Transverse magnetic focusing properties of graphene using a ballistic four terminal structure are investigated. The electric response is obtained using the semiclassical billiard model. The transmission exhibits pronounced peaks as a consequence of skipping orbits at the edge of the structure. When we add a pn-junction between the two probes, snake states along the pn-interface appear. Injected electrons are guided by the pn-interface to one of the leads depending on the value of the applied magnetic field. Oscillations in the resistance are found depending on the amount of particles that end up in each lead.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Negative Mass Instability in an Enge "Pretzel" Magnet

A novel magnet invented by Harald Enge has the useful property of achromatically deflecting charged particle beams. One can envision many applications for these for transport and guiding in high-current electron beam research. However, a high-current electron beam bent by the magnetic field in one of these magnets is subject to the negative mass instability. The negative mass instability is a problem for all accelerators that rely on magnetic fields to bend or circulate the beam. The subject of this article is the assessment of this instability in these devices for a range of electron beam parameters typical of the linear induction accelerators (LIAs) at Los Alamos. We first describe the properties of the magnet, and then calculate the negative mass instability growth rate for a high current beam having parameters of interest. Finally, we show that the beam does not spend enough time circulating through the magnet for the instability to grow significantly.

43 PARTICLE ACCELERATORS↗

Coherent propagation of charged particle bunches in random magnetic fields

When the distribution function for energetic particles moving in interplanetary space is expressed in terms of eigenfunctions of an operator which describes pitch angle scattering by random magnetic fields, the familiar phenomenon of diffusion is the dominant solution of the transport equations provided that the spectrum of magnetic fluctuations is not too steep. The present paper describes a novel mode of particle transport when the latter condition is not satisfied (i.e., when the exponent for the spectrum of magnetic fluctuations is greater than 2). In this mode, the density inhomogeneities propagate coherently, in wavelike fashion, and with very little dispersion along the guiding field at a characteristic velocity equal to half the particle speed. The most striking manifestation of this phenomenon is the observed scatter-free propagation of solar flare electrons below 1 MeV.-

Earl, J. A.↗

THE ACCELERATION OF IONS IN SOLAR FLARES DURING MAGNETIC RECONNECTION

The acceleration of solar flare ions during magnetic reconnection is explored via particle-in-cell simulations that self-consistently and simultaneously follow the motions of both protons and {alpha} particles. We show that the dominant heating of thermal ions during guide field reconnection, the usual type in the solar corona, results from pickup behavior during the entry into reconnection exhausts. In contrast to anti-parallel reconnection, the temperature increment is dominantly transverse, rather than parallel, to the local magnetic field. A comparison of protons and {alpha} reveals a mass-to-charge (M/Q) threshold in pickup behavior that favors the heating of high-M/Q ions, which is consistent with impulsive flare observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Comprehensive tracking study for the H-dipoles and common magnets in the splitter sections of the Cornell/Brookhaven Energy-Recovery-Linac Test Accelerator

The Cornell-Brookhaven Energy-Recovery-Linac Test Accelerator will have two splitter sections responsible for and guiding beams of 42, 78, 114, and 150 MeV energies between the Fixed-Field Alternating Gradient return loop and the Main Linac Cryomodule [6], correcting optics, and providing path length adjustments. Modeling of all 36 H-dipole magnets under contract with Elytt Energy has been completed. Four common dipoles, two of which are needed for next year’s Fractional Arc Test, will be added to the order with Elytt. The design of these magnets is underway. This report describes the findings of the tracking studies of the 36 H-dipoles and gives the status of the common dipoles.

43 PARTICLE ACCELERATORS↗

Direct construction of optimized stellarator shapes. Part 2. Numerical quasisymmetric solutions

Quasisymmetric stellarators are appealing intellectually and as fusion reactor candidates since the guiding-centre particle trajectories and neoclassical transport are isomorphic to those in a tokamak, implying good confinement. Previously, quasisymmetric magnetic fields have been identified by applying black-box optimization algorithms to minimize symmetry-breaking Fourier modes of the field strength $B$ . Here, instead, we directly construct magnetic fields in cylindrical coordinates that are quasisymmetric to leading order in the distance from the magnetic axis, without using optimization. The approach involves solution of a one-dimensional nonlinear ordinary differential equation, originally derived by Garren & Boozer ( Phys. Fluids B, vol. 3, 1991, p. 2805). We illustrate the usefulness and accuracy of this optimization-free approach by providing the results of this construction as input to the codes VMEC and BOOZ_XFORM, confirming the purity and scaling of the magnetic spectrum. The space of magnetic fields that are quasisymmetric to this order is parameterized by the magnetic axis shape along with three other real numbers, one of which reflects the on-axis toroidal current density, and another one of which is zero for stellarator symmetry. The method here could be used to generate good initial conditions for conventional optimization, and its speed enables exhaustive searches of parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adiabatic charged particle motion in rapidly rotating magnetospheres

Some aspects of adiabatic drift theory are investigated in the regime where the E x B drift velocity is comparable with or larger than the gyro velocity. Particles undergo five drifts in addition to the E x B gradient, and line curvature drifts have three more terms in the parallel equation of motion. The case of the rapidly rotating rigid magnetic field configuration is found to be an exception due to the corotating particle with a nearly periodic motion. The guiding center drift velocity and parallel differential equation of motion are obtained, and the drift velocity in the rotating frame is found to consist of the expected field gradient and line curvature drift, plus centrifugal and coriolis force induced drifts. It is shown that the second invariant is conserved in the rotating frame by the four drifts, so that a particle slowly drifts around on its drift shell and returns to its original field line. Thus, there is no long term energy change, and any energy change is periodic on the bounce and drift time scale.

Northrop, T. G.↗

Dry coupled magnetostrictive transducers for robotic inspection of dry storage casks - 15304

The lack of a national repository for used nuclear fuel has lead to the usage of dry storage casks as the de facto long term storage solution, the usage of which is prevalent throughout the United States. Furthermore, as shown in figure 3, the usage of dry storage is only expected to increase over time. Because these casks were originally intended as only an interim measure, there is an urgent need to develop methods to monitor their structural health over the long-term. Additionally, when concerns about the susceptibility of these casks to cracking is considered, the need for inspection becomes even more apparent. The use of robotic devices to inspect the interior of these casks for signs of damage has been proposed, but in order for this to be realized, advances in sensing technology must occur. We develop a novel type of transducer for non-destructive evaluation to aid in these efforts. We construct a prototype sensor, demonstrate simple defect detection with it, and present a design for an inspection robot equipping these transducers. Ultrasonic inspection is a well known method of non-destructive evaluation which works by measuring the response of ultrasonic waves propagating through a material. In through-transmission inspection, a transmitter and receiver are used to generate and detect waves in the material to be inspected. The presence of a crack or defect in the material will scatter some of the transmitted wave's energy, reducing the strength of the response at the receiver. Magnetostrictive transducers are often used to generate and detect guided waves. These transducers depend on the magnetostrictive effect, where certain materials will deform in the presence of a magnetic field. The typical construction of one of these transducers is shown in figure 5, consisting of a magnetostrictive foil, meandering coil, and a biasing magnet. Materials typically used for the foil include Fe-Co and Terfenol-D. For wave generation, a high-frequency alternating current is supplied to the coil of the transducer, which generates an oscillating magnetic field that causes the foil to deform. For reception, the inverse occurs: deformation of the foil results in a current in the coil that can be detected. The deformation of the foil is usually coupled to the material to be inspected with an adhesive, and waves are transmitted through this bond. Obviously, an inspection robot cannot have its sensors bound to the surface of the cask. A robot is being designed for inspection, and it must deal with many challenges inside the cask, including tight confines, right-angle transitions, high temperatures, and radiation. For our initial design, we consider only the geometrical constraints, and present a design for a prototype that can be assembled from COTS components. The robot needs to be articulated to navigate the bends in the cask, so each wheel is individually actuated. The robot is controlled via a tether, which also supplies electrical power and compressed air. For localization, ultrasonic range-finders and a camera are equipped. Using the basic transducer, we experimented with various configurations of materials and geometry. In order to gather relevant data, we used force sensitive resistors to measure applied force, and a Matec computer system to generate and measure ultrasonic waves. A testing rig was constructed to simulate the geometrical constraints of the interior of the cask, and we experimented using deadweights, a pneumatic cylinder, and an air bladder to apply the force. It was discovered early in the testing process that the performance of the transducer was very sensitive to the alignment of the components, and the method by which the foil was attached. To maximize performance, we designed an enclosure that would hold the components in alignment while still allowing the foil to float. To test the effectiveness of our new transducer, we cut circular holes of varying diameter in 2 mm aluminum plate, and measured the response across them. It can be seen that there is a clear relationship between the strength of the received signal and the force applied, and to a lesser extent, the size of the defect. This design performs adequately as a proof of concept, and a more precisely fabricated enclosure should further increase the accuracy of its measurements.

42 ENGINEERING↗

Violation of Field Line Conservation and Associated Spatial Scales in Particle-in-Cell Simulations and MMS Data

For the first time, space flight technology exists to detect, in situ, violation of magnetic field line conservation. The violation of magnetic line conservation on scales smaller than the system size is a necessary and sufficient condition for finite magnetic field reconnection. We demonstrate that violation of line conservation produces a detectable, structured signature both in particle-in-cell simulations of reconnection and in data from the Magnetospheric Multi-Scale mission. In particle-in-cell simulations of asymmetric reconnection, the quantity—which we call M—that identifies this violation achieves significant values in electron skin depth-scale layers that extend away from the separator, with higher values emerging on the low-density, high-magnetic-field side of the current sheet. At the separator, M owes largely to perpendicular gradients in the parallel electric field, while it attains its highest values away from the separator in dispersed, layered structures associated with gradients in the perpendicular nonideal electric field and electron transport. Sub-ion scale bipolar forms of the quantity also appear further from the separator. In two MMS burst data intervals detecting the electron diffusion region, we find that M exceeds measurement uncertainties both at the separator and near the separatrices. One interval has highly sheared reconnecting fields and the other a stronger guide field. For one event, we determine the location and scale of M and the inner electron diffusion region relative to electron outflows and the magnetic separatrices. The measure can therefore serve as a potent diagnostic for magnetic reconnection in space measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Violation of Field Line Conservation and Associated Spatial Scales in Particle-In-Cell Simulations and MMS Data

For the first time, space flight technology exists to detect, in situ, violation of magnetic field line conservation. The violation of magnetic line conservation on scales smaller than the system size is a necessary and sufficient condition for finite magnetic field reconnection. We demonstrate that violation of line conservation produces a detectable, structured signature both in particle-in-cell simulations of reconnection and in data from the Magnetospheric Multi-Scale mission. In particle-in-cell simulations of asymmetric reconnection, the quantity-which we call M-that identifies this violation achieves significant values in electron skin depth-scale layers that extend away from the separator, with higher values emerging on the low-density, high-magnetic-field side of the current sheet. At the separator, M owes largely to perpendicular gradients in the parallel electric field, while it attains its highest values away from the separator in dispersed, layered structures associated with gradients in the perpendicular nonideal electric field and electron transport. Sub-ion scale bipolar forms of the quantity also appear further from the separator. In two MMS burst data intervals detecting the electron diffusion region, we find that M exceeds measurement uncertainties both at the separator and near the separatrices. One interval has highly sheared reconnecting fields and the other a stronger guide field. For one event, we determine the location and scale of M and the inner electron diffusion region relative to electron outflows and the magnetic separatrices. The measure can therefore serve as a potent diagnostic for magnetic reconnection in space measurements.

Wendel, Deirdre E.↗

Reconnection Guide Field and Quadrupolar Structure Observed by MMS on 16 October 2015 at 1307 UT

We estimate the guide field near the X point, B(sub M0), for a magnetopause crossing by the Magnetospheric Multiscale (MMS) spacecraft at 1307 UT on 16 October 2015 that showed features of electron-scale reconnection. This component of the magnetic field is normal to the reconnection plane L-N containing the reconnection magnetic field, B(sub L), and the direction e(sub N) normal to the current sheet. The B(sub M) field component appears to approximately have quadrupolar structure close to the X point. Using several different methods to estimate values of the guide field near the X point, some of which use an assumed quadrupolar symmetry, we find values ranging between -3.1 nT and -1.2 nT, with a nominal value of about -2.5 nT. The rough consistency of these values is evidence that the quadrupolar structure exists.

Denton, R. E.↗

A two-fluid study of oblique tearing modes in a force-free current sheet

Kinetic simulations have demonstrated that three-dimensional reconnection in collisionless regimes proceeds through the formation and interaction of magnetic flux ropes, which are generated due to the growth of tearing instabilities at multiple resonance surfaces. Since kinetic simulations are intrinsically expensive, it is desirable to explore the feasibility of reduced two-fluid models to capture this complex evolution, particularly, in the strong guide field regime, where two-fluid models are better justified. With this goal in mind, this paper compares the evolution of the collisionless tearing instability in a force-free current sheet with a two-fluid model and fully kinetic simulations. Our results indicate that the most unstable modes are oblique for guide fields larger than the reconnecting field, in agreement with the kinetic results. The standard two-fluid tearing theory is extended to address the tearing instability at oblique angles. The resulting theory yields a flat oblique spectrum and underestimates the growth of oblique modes in a similar manner to kinetic theory relative to kinetic simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The CLAS12 Central Time-of-Flight system

The Central Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system consists of a hermetic barrel of 48 scintillation counters at a radius of 25 cm from the beamline. The wedge-shaped counters are 3.4 cm wide, 3.0 cm thick, and 90 cm long, and span a range of polar angles relative to the center of the nominal target location from roughly 35° to 125°. The counters reside in the 5-T field of the CLAS12 superconducting solenoid. The bars are read out via bent light guides 1 m long on the upstream end of the counters and 1.6 m long on the downstream end. The phototubes are shielded by a multi-layer dynamical magnetic shield system to reduce the local fringe fields in the range from 400 G to 1000 G down to the level of 0.2 G at the location of the photocathodes. The average effective time resolution of the counters is 80 ps.

47 OTHER INSTRUMENTATION↗