Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Quantifying Dynamic Water Storage in Unsaturated Bedrock with Borehole Nuclear Magnetic Resonance

Quantifying the volume of water that is stored in the subsurface is critical to studies of water availability to ecosystems, slope stability, and water-rock interactions. In a variety of settings, water is stored in fractured and weathered bedrock as rock moisture. However, few techniques are available to measure rock moisture in unsaturated rock, making direct estimates of water storage dynamics difficult to obtain. Here, we use borehole nuclear magnetic resonance (NMR) at two sites in seasonally dry California to quantify dynamic rock moisture storage. Additionally, we show strong agreement between NMR estimates of dynamic storage and estimates derived from neutron logging and mass balance techniques. The depths of dynamic storage are up to 9 m and likely reflect the depth extent of root water uptake. To our knowledge, these data are the first to quantify the volume and depths of dynamic water storage in the bedrock vadose zone via NMR.

58 GEOSCIENCES↗

Enhanced magnetic resonance signal of spin-polarized Rb atoms near surfaces of coated cells

We present a detailed experimental and theoretical study of edge enhancement in optically pumped Rb vapor in coated cylindrical pyrex glass cells. The Zeeman polarization of Rb atoms is produced and probed in the vicinity ({approx}10{sup -4} cm) of the cell surface by evanescent pump and probe beams. Spin-polarized Rb atoms diffuse throughout the cell in the presence of magnetic field gradients. In the present experiment the edge enhanced signal from the back surface of the cell is suppressed compared to that from the front surface, due to the fact that polarization is probed by the evanescent wave at the front surface only. The observed magnetic resonance line shape is reproduced quantitatively by a theoretical model and yields information about the dwell time and relaxation probability of Rb atoms on Pyrex glass surfaces coated with antirelaxation coatings.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nuclear magnetic resonance dark-matter searches are sensitive to dark photons and the axion-photon coupling

We demonstrate that nuclear magnetic resonance based searches for dark matter (DM) have intrinsic and powerful sensitivity to dark photons and the axion-photon coupling. The reason is conceptually straightforward. An instrument such as CASPEr-Gradient begins with a large sample of nuclear spins polarized in a background magnetic field. In the presence of axion DM coupled to nucleons, the spin ensemble feels an effective magnetic field 𝐁 ∝ ∇𝑎 that tilts the spins, generating a potentially observable precession. If the magnetic field is real rather than effective, the system responds identically. A real field can be generated by a kinetically mixed dark photon within the shielded region the sample is placed or an axion coupled to photons through its interaction with the background magnetic field. We show that all three signals are detectable and distinguishable. If CASPEr-Gradient were to reach the QCD axion prediction of the axion-nucleon coupling, it would simultaneously be sensitive to kinetic mixings of 𝜀 ≃ 3 × 10 −16 and axion-photon couplings of 𝑔 𝑎⁢𝛾⁢𝛾 ≃ 2 × 10 −16 GeV −1 for 𝑚 ≃ 1 𝜇⁢eV. Our analysis demonstrates that CASPEr-Gradient has the tantalizing possibility of simultaneously measuring two separate couplings of axion dark matter, thereby providing a unique window into the axion’s UV completion.

Beadle, Carl [University of Geneva (Switzerland)] ↗

Influence of the Resonant Magnetic Perturbation on the Plasma Boundary in DIII-D

Stochastic boundaries in fusion devices have been investigated in tokamaks, stellarators and reversed field pinch experiments for many years. However, since edge localized modes (ELMs) have been successfully eliminated in H-mode plasmas at the DIII-D tokamak [1,2] with small, edge resonant magnetic perturbations, they have become a widely investigated topic in tokamaks. In DIII-D stochastic boundaries are produced by coils external to the plasma. The magnetic field there consists of field lines with very different connection lengths, which produces a three dimensional, heterogenous structure of stochastic volume. The most obvious manifestation of the perturbed plasma edge is the strike line splitting observable in heat and particle fluxes, which changes with collisionality. The interaction of the magnetic perturbation and the magnetic equilibrium is of a resonant nature and the structure of the stochastic volume is a strong function of q(95). This is observed as a modulation of e.g. electron temperature as measured by ECE or Thomson scattering. In this work we summarize recent experimental findings on properties of the stochastic boundary in DIII-D. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative prediction of radio frequency induced local heating derived from measured magnetic field maps in magnetic resonance imaging: A phantom validation at 7 T

Electrical Properties Tomography (EPT) technique utilizes measurable radio frequency (RF) coil induced magnetic fields (B1 fields) in a Magnetic Resonance Imaging (MRI) system to quantitatively reconstruct the local electrical properties (EP) of biological tissues. Information derived from the same data set, e.g., complex numbers of B1 distribution towards electric field calculation, can be used to estimate, on a subject-specific basis, local Specific Absorption Rate (SAR). SAR plays a significant role in RF pulse design for high-field MRI applications, where maximum local tissue heating remains one of the most constraining limits. The purpose of the present work is to investigate the feasibility of such B1-based local SAR estimation, expanding on previously proposed EPT approaches. To this end, B1 calibration was obtained in a gelatin phantom at 7 T with a multi-channel transmit coil, under a particular multi-channel B1-shim setting (B1-shim I). Using this unique set of B1 calibration, local SAR distribution was subsequently predicted for B1-shim I, as well as for another B1-shim setting (B1-shim II), considering a specific set of parameter for a heating MRI protocol consisting of RF pulses plaid at 1% duty cycle. Local SAR results, which could not be directly measured with MRI, were subsequently converted into temperature change which in turn were validated against temperature changes measured by MRI Thermometry based on the proton chemical shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid-State Nuclear Magnetic Resonance as a Tool to Probe the Impact of Mechanical Preprocessing on the Structure and Arrangement of Plant Cell Wall Polymers

Efficient separation of the plant cell wall polymers during lignocellulose processing has been historically challenging due to insolubility of the polymers and their propensity for recalcitrant reassembly. Methods, such as “lignin first” extraction techniques, have advanced efficient biomass use, but the molecular mechanisms for recalcitrance remain enigmatic. Here, we discuss how solid-state Nuclear Magnetic Resonance (NMR) approaches report on the 3D organization of cellulose, xylan, and lignin in the plant cell wall. Recent results illustrate that the organization of these polymers varies across biomass sources and sample preparation methods, with even minimal physical processing causing significant effects. These structural differences contribute to variable extraction efficiencies for bioproducts after downstream processing. We propose that solid-state NMR methods can be applied to follow biomass processing, providing an understanding of the polymer rearrangements that can lead to poor yields for the desired bioproducts. The utility of the technique is illustrated for mechanical processing using lab-scale vibratory ball milling of Sorghum bicolor .

59 BASIC BIOLOGICAL SCIENCES↗

Microscopic subsurface characterization of layered magnetic materials using magnetic resonance force microscopy

This project resulted in the following accomplishments: 1) The invention of scanned probe ferromagnetic resonance microscopy. Upon implementation and refinement this approach was used to measure static and dynamic magnetic resonance properties of ferromagnets with an unprecedented combination of spectral and spatial resolution. 2) Demonstration and study of spin pumping in a pristine ferromagnet across a boundary defined entirely by a magnetic field gradient, and so free of materials discontinuities. 3) First demonstrated highly efficient dynamic spin injection from Y 3 Fe 5 O 12 (YIG) into NiO, an antiferromagnetic (AF) insulator and robust spin propagation in AF NiO over distances up to 100-nm thickness; both spin injection and spin transport are mediated by the AF spin correlations. 4) Demonstration of exceptionally high efficiency conversion of spin current to charge current achieved in spin pumping from the dynamic magnetization of a ferromagnetic insulator into a variety of adjacent metal films. 5) Seminal study of the nature of spin-orbit coupling in d-electron metals that revealed the dominant sensitivity of the d-orbital moment to the d-electron count and revealing the important roles of both d-electron configuration and atomic number in the physics of the spin Hall effect. 6) Demonstration of observation of FMR by means of optically-detected NV diamond relaxometry that provided a highly sensitive, spatially resolved FMR detection method and revealed spin pumping across 100-nm length scales by means of dipolar coupling. 7) Using magnetic field localization, developed for FMR imaging, demonstrated a novel approach to discretizing spin wave modes to improve the characteristics of auto-oscillators driven by pure spin currents produced by the spin Hall effect. 8) We demonstrated large spin pumping signals from propagating high wavevector spinwaves in thin film YIG find that the spin pumping efficiency was insensitive to wavevector thus emphasizing the promise of thin YIG films for spinwave-based spintronics by allowing for predictable down-scaling of device dimensions and enabling a broad range of operational frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Porous silicon nanoparticles as biocompatible contrast agents for magnetic resonance imaging

We propose porous silicon nanoparticles (PSi NPs) with natural oxide coating as biocompatible and bioresorbable contrast agents for magnetic resonant imaging (MRI). A strong shortening of the transversal proton relaxation time (T{sub 2}) was observed for aqueous suspensions of PSi NPs, whereas the longitudinal relaxation time (T{sub 1}) changed moderately. The longitudinal and transversal relaxivities are estimated to be 0.03 and 0.4 l/(g·s), respectively, which are promising for biomedical studies. The proton relaxation is suggested to undergo via the magnetic dipole-dipole interaction with Si dangling bonds on surfaces of PSi NPs. MRI experiments with phantoms have revealed the remarkable contrasting properties of PSi NPs for medical diagnostics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clear Depiction of Inflammatory Abdominal Aortic Aneurysm with Diffusion-Weighted Magnetic Resonance Imaging

We report the case of an inflammatory abdominal aortic aneurysm incidentally detected clearly with diffusion-weighted magnetic resonance imaging (DW-MRI) during the examination of a patient with myelofibrosis with myeloid metaplasia that later converted to acute myeloid leukemia. DW-MRI revealed a hyperintense halo surrounding the abdominal aorta with aneurysmatic dilatation, establishing the diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiquantitative and Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging Measurements Predict Radiation Response in Cervix Cancer

Purpose: To evaluate semiquantitative and quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measurements in predicting the response to radiotherapy in cervix cancer. Methods and Materials: Patients with cervix cancer treated radically with chemoradiotherapy had DCE-MRI at three time points: before starting treatment, after 2 weeks of radiotherapy, and in the 5th week of radiotherapy. Semiquantitative measurements obtained from the signal intensity vs. time plots included arrival time of contrast, the slope and maximum slope of contrast uptake, time for peak enhancement, and the contrast enhancement ratio (CER). Pharmacokinetic modeling with a modeled vascular input function was used for the quantitative measurements volume transfer constant (K{sup trans}), rate constant (k{sub ep}), fraction plasma volume (fPV), and the initial area under gadolinium-time curve. The correlation of these measurements at each of the three time points with radiologic tumor response was investigated. Results: Thirteen patients had a total of 38 scans. There was no correlation between the DCE-MRI measurements and the corresponding tumor volumes. A statistically significant correlation with percentage tumor regression was shown with the pretreatment DCE-MRI semiquantitative parameters of peak time (p = 0.046), slope (p = 0.025), maximum slope (p = 0.046), and CER (p = 0.025) and the quantitative parameters K{sup trans} (p = 0.043) and k{sub ep} (p = 0.022). Second and third scan measurements did not show any correlation. Conclusions: This is the first study to show that pretreatment DCE-MRI quantitative parameters predict the radiation response in cervix cancer. These measurements may allow a more meaningful comparison of DCE-MRI studies from different centers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Differentiation of Pseudoprogression From True Tumor Progression With Dynamic Susceptibility-Weighted Contrast-Enhanced Magnetic Resonance Imaging Using Ferumoxytol vs. Gadoteridol: A Pilot Study

Purpose: We evaluated dynamic susceptibility-weighted contrast-enhanced magnetic resonance imaging (DSC-MRI) using gadoteridol in comparison to the iron oxide nanoparticle blood pool agent, ferumoxytol, in patients with glioblastoma multiforme (GBM) who received standard radiochemotherapy (RCT). Methods and Materials: Fourteen patients with GBM received standard RCT and underwent 19 MRI sessions that included DSC-MRI acquisitions with gadoteridol on Day 1 and ferumoxytol on Day 2. Relative cerebral blood volume (rCBV) values were calculated from DSC data obtained from each contrast agent. T1-weighted acquisition post-gadoteridol administration was used to identify enhancing regions. Results: In seven MRI sessions of clinically presumptive active tumor, gadoteridol-DSC showed low rCBV in three and high rCBV in four, whereas ferumoxytol-DSC showed high rCBV in all seven sessions (p = 0.002). After RCT, seven MRI sessions showed increased gadoteridol contrast enhancement on T1-weighted scans coupled with low rCBV without significant differences between contrast agents (p = 0.9). Based on post-gadoteridol T1-weighted scans, DSC-MRI, and clinical presentation, four patterns of response to RCT were observed: regression, pseudoprogression, true progression, and mixed response. Conclusion: We conclude that DSC-MRI with a blood pool agent such as ferumoxytol may provide a better monitor of tumor rCBV than DSC-MRI with gadoteridol. Lesions demonstrating increased enhancement on T1-weighted MRI coupled with low ferumoxytol rCBV are likely exhibiting pseudoprogression, whereas high rCBV with ferumoxytol is a better marker than gadoteridol for determining active tumor. These interesting pilot observations suggest that ferumoxytol may differentiate tumor progression from pseudoprogression and warrant further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cervical Gross Tumor Volume Dose Predicts Local Control Using Magnetic Resonance Imaging/Diffusion-Weighted Imaging—Guided High-Dose-Rate and Positron Emission Tomography/Computed Tomography—Guided Intensity Modulated Radiation Therapy

Purpose: Magnetic resonance imaging/diffusion weighted-imaging (MRI/DWI)-guided high-dose-rate (HDR) brachytherapy and {sup 18}F-fluorodeoxyglucose (FDG) — positron emission tomography/computed tomography (PET/CT)-guided intensity modulated radiation therapy (IMRT) for the definitive treatment of cervical cancer is a novel treatment technique. The purpose of this study was to report our analysis of dose-volume parameters predicting gross tumor volume (GTV) control. Methods and Materials: We analyzed the records of 134 patients with International Federation of Gynecology and Obstetrics stages IB1-IVB cervical cancer treated with combined MRI-guided HDR and IMRT from July 2009 to July 2011. IMRT was targeted to the metabolic tumor volume and lymph nodes by use of FDG-PET/CT simulation. The GTV for each HDR fraction was delineated by use of T2-weighted or apparent diffusion coefficient maps from diffusion-weighted sequences. The D100, D90, and Dmean delivered to the GTV from HDR and IMRT were summed to EQD2. Results: One hundred twenty-five patients received all irradiation treatment as planned, and 9 did not complete treatment. All 134 patients are included in this analysis. Treatment failure in the cervix occurred in 24 patients (18.0%). Patients with cervix failures had a lower D100, D90, and Dmean than those who did not experience failure in the cervix. The respective doses to the GTV were 41, 58, and 136 Gy for failures compared with 67, 99, and 236 Gy for those who did not experience failure (P<.001). Probit analysis estimated the minimum D100, D90, and Dmean doses required for ≥90% local control to be 69, 98, and 260 Gy (P<.001). Conclusions: Total dose delivered to the GTV from combined MRI-guided HDR and PET/CT-guided IMRT is highly correlated with local tumor control. The findings can be directly applied in the clinic for dose adaptation to maximize local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging and Spectroscopy to Assess Leg Muscle Macrostructure and Microstructure in Healthy Older Women: A Feasibility Assessment

Advanced magnetic resonance (MR) scanning techniques, such as diffusion tensor imaging (DTI) and proton MR spectroscopy ({sup 1}H-MRS) permit microstructural evaluation of water diffusivity and intramyocellular lipid content, respectively. We aimed to determine the feasibility of performing advanced MR scanning (proton density [PD] weighted imaging, DTI, and {sup 1}H-MRS) to evaluate properties of leg muscles in older women with respect to: (1) participant recruitment using three community-based strategies; (2) participant tolerance to the MRI scan acquisition protocol; and (3) scan acquisition and analyses protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detachment stabilization with n/m=1/1 resonant magnetic perturbation field applied to the stochastic magnetic boundary of the Large Helical Device

It is found that the remnant island structure created by n/m=1/1 resonant magnetic perturbation field in the stochastic magnetic boundary of the Large Helical Device (LHD) [A. Komori et al., Nucl. Fusion 49, 104015 (2009)] has a stabilizing effect on formation of radiating plasma, realizing stably sustained divertor detachment operation with the core plasma being unaffected. The data from the several diagnostics, (profiles of electron temperature and density, radiation and temporal evolution of divertor particle flux) indicate selective cooling around X-point of the island and thus peaked radiation there, which is stabilized outside of the last closed flux surface throughout the detachment phase. The vacuum ultraviolet spectroscopy measurements of high Z impurity (iron) emission shows significant decrease during the detachment, indicating core plasma decontamination. The results from the three-dimensional (3D) edge transport code, edge Monte Carlo 3D (EMC3) [Y. Feng et al., Contrib. Plasma Phys. 44, 57 (2004)]-EIRENE [D. Reiter et al., Fusion Sci. Technol. 47, 172 (2005)] show similar tendency in the radiation pattern. The island size and its radial location are varied to investigate the magnetic topology effects on the detachment control. The divertor particle flux and neutral pressure exhibit intermittent oscillation as well as modification of recycling pattern during the detachment, which are found to reflect the island structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of resonant magnetic perturbations on nonlinearly driven modes in drift-wave turbulence

In this work, we study the effects of resonant magnetic perturbations (RMPs) on turbulence, flows, and confinement in the framework of resistive drift wave turbulence. We extend the Hasegawa-Wakatani model to include RMP fields. The effect of the RMPs is to induce a linear coupling between the zonal electric field and the zonal density gradient, which drives the system to a state of electron radial force balance for large ({delta}B{sub r}/B{sub 0}). Both the vorticity flux (Reynolds stress) and particle flux are modulated. We derive an extended predator prey model which couples zonal potential and density dynamics to the evolution of turbulence intensity. This model has both turbulence drive and RMP amplitude as control parameters and predicts a novel type of transport bifurcation in the presence of RMPs. We find states that are similar to the ZF-dominated state of the standard predator-prey model, but for which the power threshold is now a function of the RMP strength. For small RMP amplitude, the energy of zonal flows decreases and the turbulence energy increases with ({delta}B{sub r}/B{sub 0}), corresponding to a damping of zonal flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of particle exhaust control during ELM suppression by resonant magnetic perturbations in DIII-D

A reduction in plasma electron density ('pump-out') during the application of resonant magnetic perturbations (RMPs) on DIII-D precedes the suppression of edge localized modes (ELMs) in discharges with low (<= 0.2) electron pedestal collisionalities. The magnitude of the density drop near the plasma pedestal can be up to 30% and as low as similar to 2% for discharges with similar applied RMP, and thus motivates further study to determine the cause of the variation. Based on an analysis of the global particle balance and measurements of the D-alpha poloidal distribution, it is shown that the wall inventory can be strongly affected by changing the average triangularity ( ) of the discharge. Specifically, particle balance in = 0.3 discharges shows that the density pump-out was substantially higher than the increase in particle exhaust to the cryo-pumps, i.e. wall pumping was apparently required. On the other hand, particle balance in = 0.5 discharges shows that the density pump-out was offset by an increase in exhaust to the cryo-pumps, i.e. wall pumping was not required. Correspondingly, the D-alpha intensity increased by similar to 50%-100% at = 0.5 during the RMP phase of the discharge when compared with theRMPphase of a = 0.3 discharge. Both of these observations imply a possible increase in the neutral particles in the scrape-off-layer. More significantly, this new result demonstrates density pump-out and ELM suppression without significant wall pumping, which is a desirable feature for long-pulse reactors with saturated walls.

Unterberg, E. A.↗

Impact of resonant magnetic perturbations on zonal flows and microturbulence

Results from a joint experimental and computational effort studying the effect of resonant magnetic perturbations (RMPs) on microturbulence levels and their connection to zonal flows in the DIII-D tokamak L-mode are presented. Beam emission spectroscopy measurements show a direct increase in density fluctuations at microturbulent scales with increasing RMP amplitude, suggesting that magnetic activity introduced by the RMP affects the regulation of microturbulence on DIII-D. This is analogous to how MHD-scale magnetic fluctuations arising from tearing modes have been observed in simulations to increase microturbulence levels in the reversed-field pinch (RFP). In the RFP, this is attributed to magnetic fluctuations eroding turbulence-limiting zonal flows; this work examines if a similar mechanism is present for DIII-D microturbulence. Gyrokinetic simulations find that the application of an RMP corresponds directly to a decrease in zonal flow levels, producing a similar increase of turbulent fluctuation levels over a range of RMP amplitudes as observed in the experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗