Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Time-resolved vacuum-ultraviolet photoelectron spectroscopy of the à 1 A u state of acetylene

Ultrafast time-resolved photoelectron spectra are reported for the vacuum-ultraviolet (VUV) photoionization of acetylene following excitation to the à 1 A u state via UV absorption at 200 nm. The excitation energy lies above the lowest dissociation threshold to C 2 H X̃ 2 Σ + + H, as well as above the threshold for adiabatic dissociation of the à 1 A u state to form C 2 H (à 2 Π) + H. The time-dependent mass spectra and photoelectron spectra provide insight into the intramolecular decay processes of the à 1 A u state. In addition, photoelectron spectra of the à 1 A u state with VUV light access both the X̃ 2 Π u and à 2 Σ g + states of the ion, as well as the predicted, but previously unobserved, 1 2 Π g state, which corresponds to a two-hole, one-particle configuration that lies in close proximity to the à 2 Σ g + state. The 1 2 Π g state is split into 2 A 2 + 2 B 2 and 2 A g + 2 B g states in the cis and trans configurations, respectively. In conclusion, electronic structure calculations, along with trajectory calculations, reproduce the principal features of the experimental data and confirm the assignment of the 1 2 Π g state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search For Excited Cascade Hypersons (¿*-) Using the CLAS12 Spectrometer at Jefferson Laboratory

The number of experimentally observed doubly strange Cascade states to date is far fewer than has been predicted theoretically. The CLAS12 Very Strange physics program (E12- 11-005A) at the Thomas Jefferson National Accelerator Facility aims to study the electroproduction of these states using the newly upgraded CEBAF Large Acceptance Spectrometer for 12 GeV (CLAS12) in experimental Hall B. In this project, the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) is studied using CLAS12 Run Group A (RG-A) data sets taken by impinging electron beams of 10:2 and 10:6 GeV energies on an LH2 target. Scattered electrons are detected with either the Forward Detector (FD), covering a polar angle range of 5? to 35? to study electroproduction, or with the Forward Tagger (FT), covering a polar angle range of 2:5? to 4:5?, to study quasi-real photoproduction. The CLAS12 detector with nearly a 4? solid angle coverage is used to detect scattered electrons and charged kaons in the ?final state. ?=?0 hyperons are reconstructed using the missing mass technique to explore intermediate doubly-strange hyperons (???) that decay to K? and ?=?0. No statistically significant ??? states other than the ???(1530) were found in the missing mass spectra based on the currently available statistics in the CLAS12-FD acceptance only. A maximum log-likelihood method is implemented to determine the statistical significance and the upper limits on the ???(1820) electroproduction cross section by constructing 95% confidence level boundaries on the ???(1820) yields. Additional research was conducted to investigate the upper limit electroproduction cross section of the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) as a function of the electroproduced ??? mass and the differential cross section ( d?dMM(e0K+K+) ) as a function of missing mass MM(e0K+K+) for electroproduction and quasi-real photoproduction processes.

Khanal, Achyut↗

Atmospheric-pressure solution-cathode glow discharge: A versatile ion source for atomic and molecular mass spectrometry

We report an atmospheric-pressure solution-cathode glow discharge (SCGD) has been evaluated as an ion source for atomic, molecular, and ambient desorption/ionization mass spectrometry. The SCGD consists of a direct-current plasma, supported in the ambient air in the absence of gas flows, and sustained upon the surface of a flowing liquid cathode. Analytes introduced in the flowing liquid, as an ambient gas, or as a solid held near the plasma are vaporized and ionized by interactions within or near the discharge. Introduction of acidic solutions containing metal salts produced bare elemental ions as well as H 2 O, OH - and NO 3 - adducts. Detection limits for these elemental species ranged from 0.1 to 4 ppb, working curves spanned more than 4 orders of linear dynamic range, and precision varied between 5 and 16% relative standard deviation. Small organic molecules were also efficiently ionized from solution, and both the intact molecular ion and fragments were observed in the resulting SCGD mass spectra. Fragmentation of molecular species was found to be tunable; high discharge currents led to harder ionization, while low discharge currents produced stronger molecular-ion signals. Ambient gases and solids, desorbed by the plasma from a glass probe, were also readily ionized by the SCGD. Indeed, strong analyte signals were obtained from solid samples placed at least 2 cm from the plasma. These findings indicate that the SCGD might be useful also for ambient desorption/ionization mass spectrometry. In conclusion, combined with earlier results that showed the SCGD is useful for ionization of labile biomolecules, the results here indicate that the SCGD is a highly versatile ion source capable of providing both elemental and molecular mass-spectral information.

74 ATOMIC AND MOLECULAR PHYSICS↗

The THS Experiment: Simulating Titans Atmospheric Chemistry at Low Temperature (200K)

In Titan's atmosphere, composed mainly of N2 (95-98%) and CH4 (2-5%), a complex chemistry occurs at low temperature, and leads to the production of heavy organic molecules and subsequently solid aerosols. Here, we used the Titan Haze Simulation (THS) experiment, an experimental setup developed at the NASA Ames COSmIC simulation facility to study Titan's atmospheric chemistry at low temperature. In the THS, the chemistry is simulated by plasma in the stream of a supersonic expansion. With this unique design, the gas is cooled to Titan-like temperature ( approximately 150K) before inducing the chemistry by plasma, and remains at low temperature in the plasma discharge (approximately 200K). Different N2-CH4-based gas mixtures can be injected in the plasma, with or without the addition of heavier precursors present as trace elements on Titan, in order to monitor the evolution of the chemical growth. Both the gas- and solid phase products resulting from the plasma-induced chemistry can be monitored and analyzed using a combination of complementary in situ and ex situ diagnostics. A recent mass spectrometry[1] study of the gas phase has demonstrated that the THS is a unique tool to probe the first and intermediate steps of Titan's atmospheric chemistry at Titan-like temperature. In particular, the mass spectra obtained in a N2-CH4-C2H2-C6H6 mixture are relevant for comparison to Cassini's CAPS-IBS instrument. The results of a complementary study of the solid phase are consistent with the chemical growth evolution observed in the gas phase. Grains and aggregates form in the gas phase and can be jet deposited on various substrates for ex situ analysis. Scanning Electron Microscopy images show that more complex mixtures produce larger aggregates. A mass spectrometry analysis of the solid phase has detected the presence of aminoacetonitrile, a precursor of glycine, in the THS aerosols. X-ray Absorption Near Edge Structure (XANES) measurements also show the presence of imine and nitrile functional groups, showing evidence of nitrogen chemistry. These complementary studies show the high potential of THS to better understand Titan's chemistry and the origin of aerosol formation.

Laboratory↗

Laser-driven ionization mechanisms of aluminum for single particle aerosol mass spectrometry

Single particle aerosol mass spectrometry (SPAMS), an analytical technique for measuring the size and composition of individual micron-scale particles, is capable of analyzing atmospheric pollutants and bioaerosols much more efficiently and with more detail than conventional methods which require the collection of particles onto filters for analysis in the laboratory. Despite SPAMS’ demonstrated capabilities, the primary mechanisms of ionization are not fully understood, which creates challenges in optimizing and interpreting SPAMS signals. In this paper, we present a well-stirred reactor model for the reactions involved with the laser-induced vaporization and ionization of an individual particle. The SPAMS conditions modeled in this paper include a 248 nm laser which is pulsed for 8 ns to vaporize and ionize each particle in vacuum. The ionization of 1 μm, spherical Al particles was studied by approximating them with a 0-dimensional plasma chemistry model. The primary mechanism of absorption of the 248 nm photons was pressure-broadened direct photoexcitation to Al(y 2 D). Atoms in this highly excited state then undergo superelastic collisions with electrons, heating the electrons and populating the lower energy excited states. We found that the primary ionization mechanism is electron impact ionization of various excited state Al atoms, especially Al(y 2 D). Because the gas expands rapidly into vacuum, its temperature decreases rapidly. The rate of three-body recombination (e - + e - + Al + → Al + e - ) increases at low temperature, and most of the electrons and ions produced recombine within several μs of the laser pulse. The importance of the direct photoexcitation indicates that the relative peak heights of different elements in SPAMS mass spectra may be sensitive to the available photoexcitation transitions. We also discuss the effects of laser intensity, particle diameter, and expansion dynamics.

47 OTHER INSTRUMENTATION↗

Observation of New Charmonium or Charmoniumlike States in B + → D * ± D ∓ K + Decays

A study of resonant structures in B + → D * + D − K + and B + → D * − D + K + decays is performed, using proton-proton collision data at center-of-mass energies of s = 7 , 8, and 13 TeV recorded by the LHCb experiment, corresponding to an integrated luminosity of 9 fb − 1 . A simultaneous amplitude fit is performed to the two channels with contributions from resonances decaying to D * − D + and D * + D − states linked by C parity. This procedure allows the C parities of resonances in the D * ± D ∓ mass spectra to be determined. Four charmonium or charmoniumlike states are observed decaying into D * ± D ∓ : η c ( 3945 ) , h c ( 4000 ) , χ c 1 ( 4010 ) , and h c ( 4300 ) , with quantum numbers J P C equal to 0 − + , 1 + − , 1 + + , and 1 + − , respectively. At least three of these states have not been observed previously. In addition, the existence of the T c ¯ s ¯ 0 * ( 2870 ) 0 and T c ¯ s ¯ 1 * ( 2900 ) 0 resonances in the D − K + mass spectrum, already observed in the B + → D + D − K + decay, is confirmed in a different production channel. © 2024 CERN, for the LHCb Collaboration 2024 CERN

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for heavy resonances and quantum black holes in eμ, eτ, and μτ final states in proton-proton collisions at $\sqrt{s}$ = 13 TeV

A search is reported for heavy resonances and quantum black holes decaying into eμ, eτ, and μτ final states in proton-proton collision data recorded by the CMS experiment at the CERN LHC during 2016–2018 at $\sqrt{s}$ = 13 TeV, corresponding to an integrated luminosity of 138 fb -1 . The eμ, eτ, and μτ invariant mass spectra are reconstructed, and no evidence is found for physics beyond the standard model. Upper limits are set at 95% confidence level on the product of the cross section and branching fraction for lepton flavor violating signals. Three benchmark signals are studied: resonant τ sneutrino production in R parity violating supersymmetric models, heavy Z' gauge bosons with lepton flavor violating decays, and nonresonant quantum black hole production in models with extra spatial dimensions. Resonant τ sneutrinos are excluded for masses up to 4.2TeV in the eμ channel, 3.7TeV in the eτ channel, and 3.6TeV in the μτ channel. A Z' boson with lepton flavor violating couplings is excluded up to a mass of 5.0TeV in the eμ channel, up to 4.3Te V in the eτ channel, and up to 4.1TeV in the μτ channel. Quantum black holes in the benchmark model are excluded up to the threshold mass of 5.6TeV in the eμ channel, 5.2TeV in the eτ channel, and 5.0TeV in the μτ channel. In addition, model-independent limits are extracted to allow comparisons with other models for the same final states and similar event selection requirements. The results of these searches provide the most stringent limits available from collider experiments for heavy particles that undergo lepton flavor violating decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of Aliphatically Bridged Multi-Core Polycyclic Aromatic Hydrocarbons in Sooting Flames with Atmospheric-Sampling High-Resolution Tandem Mass Spectrometry

This paper provides experimental evidence for the chemical structures of aliphatically substituted and bridged polycyclic aromatic hydrocarbon (PAH) species in gas-physe combustion environments. The identification of these single- and multicore aromatic species, which have been hypothesized to be important in PAH growth and soot nucleation, was made possible through a combination of sampling gaseous constituents from an atmospheric pressure inverse coflow diffusion flame of ethylene and high-resolution tandem mass spectrometry (MS-MS). In these experiments, the flame-sampled components were ionized using a continuous VUV lamp at 10.0 eV and the ions were subsequently fragmented through collisions with Ar atoms in a collision-induced dissociation (CID) process. The resulting fragment ions, which were separated using a reflectron time-of-flight mass spectrometer, were used to extract structural information about the sampled aromatic compounds. The high-resolution mass spectra revealed the presence of alkylated single-core aromatic compounds and the fragment ions that were observed correspond to the loss of saturated and unsaturated units containing up to a total of 6 carbon atoms. Furthermore, the aromatic structures that form the foundational building blocks of the larger PAHs were identified to be smaller single-ring and pericondensed aromatic species with repetitive structural features. For demonstrative purposes, details are provided for the CID of molecular ions at masses 202 and 434. Insights into the role of the aliphatically substituted and bridged aromatics in the reaction network of PAH growth chemistry were obtained from spatially resolved measurements of the flame. The experimental results are consistent with a growth mechanism in which alkylated aromatics are oxidized to form pericondensed ring structures or react and recombine with other aromatics to form larger, potentially three-dimensional, aliphatically bridged multicore aromatic hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ga-implantation in Ge: Electrical activation and clustering

The electrical activation and clustering of Ga implanted in crystalline Ge was investigated in the (0.3-1.2)x10{sup 21} Ga/cm{sup 3} concentration range. To this aim, Ge samples implanted with 50 keV gallium, and annealed at several temperatures up to 650 deg. C, have been subjected to a detailed structural and electrical characterization. The substrate was maintained at 77 K during implantation to avoid the formation of the honeycomb structure that occurs during implantation at room temperature of heavy ions at high fluence. Secondary ion mass spectrometry analyses indicated a negligible Ga diffusion and dopant loss during the thermal annealing. The carrier concentration in the recrystallized samples measured by Hall effect showed a maximum concentration of active Ga of approx6.6x10{sup 20} Ga/cm{sup 3}. A remarkable Ga deactivation occurred with increasing the annealing temperature from 450 to 650 deg. C although the sheet resistance did not change considerably in this temperature range. It turned out that the carrier concentration reduction is balanced by the enhancement of the hole mobility that exhibits a steep variation with the concentration of the ionized scattering centers in this range. A simple model is proposed to explain the experimental results taking into account the thermally activated Ga clustering. These studies, besides clarifying the mechanism of Ga deactivation in Ge, can be helpful for the realization of future generation devices based on Ge.

36 MATERIALS SCIENCE↗

Strongly enhanced incorporation of oxygen into barium titanate based multilayer ceramic capacitors using water vapor

The reoxidation of sintered BaTiO{sub 3}-based multilayer ceramic capacitors (MLCCs) is currently an empirically determined, but poorly understood, procedure. In this work, the incorporation of oxygen into BaTiO{sub 3}-based MLCCs has been studied by means of isotope exchange annealing ({sup 18}O{sub 2}/{sup 16}O{sub 2}, {sup 1}H{sub 2}{sup 18}O/{sup 1}H{sub 2}{sup 16}O or {sup 2}H{sub 2}{sup 16}O/{sup 1}H{sub 2}{sup 16}O) and subsequent determination of the isotope profiles in the solid by secondary ion mass spectrometry. Oxygen isotope profiles in the barium titanate dielectric can be described by a bulk diffusion coefficient D* and a surface exchange coefficient k*. The values obtained for k* indicate that oxygen incorporation from H{sub 2}O is much faster than from dry O{sub 2}; it thus plays the key role in the reoxidation process.

36 MATERIALS SCIENCE↗

Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.

47 OTHER INSTRUMENTATION↗

Laser Desorption Postionization Mass Spectrometry of Antibiotic-Treated Bacterial Biofilms using Tunable Vacuum Ultraviolet Radiation

Laser desorption postionization mass spectrometry (LDPI-MS) with 8.0 ? 12.5 eV vacuum ultraviolet synchrotron radiation is used to single photon ionize antibiotics andextracellular neutrals that are laser desorbed both neat and from intact bacterial biofilms. Neat antibiotics are optimally detected using 10.5 eV LDPI-MS, but can be ionized using 8.0 eV radiation, in agreement with prior work using 7.87 eV LDPI-MS. Tunable vacuum ultraviolet radiation also postionizes laser desorbed neutrals of antibiotics and extracellular material from within intact bacterial biofilms. Different extracellular material is observed by LDPI-MS in response to rifampicin or trimethoprim antibiotic treatment. Once again, 10.5 eV LDPI-MS displays the optimum trade-off between improved sensitivity and minimum fragmentation. Higher energy photons at 12.5 eV produce significant parent ion signal, but fragment intensity and other low mass ions are also enhanced. No matrix is added to enhance desorption, which is performed at peak power densities insufficient to directly produce ions, thus allowing observation of true VUV postionization mass spectra of antibiotic treated biofilms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cirrus microphysics observations made during FIRE 2: Small particles, high concentrations, and probe comparisons

Aircraft observations of cirrus cloud microphysics were made near Coffeyville, Kansas during Nov. and Dec. 1991. Cloud microphysics measurements were made using both a PMS 2DC probe and an ice particle replicator, both were mounted on the UND Citation aircraft. Intercomparison is made of the size, area, and ice mass spectra determined from these probes. The PMS 2DC undercounts particles for D less than 70 microns and the replicator oversizes particles for D greater than 150 microns, at least when column rosettes are encountered. High concentrations of particles with D less than 50 microns are noted in selected portions of the 22 Nov. 91 replicator data set. Relations between the maximum dimension of a crystal and its shadow area (known as area dimensional relationships) are computed from the PMS data. Area and mass dimensional relationships are used to give a simple analytical expression for computing the wavelength dependent absorption coefficient averaged over a size bin. Calculations based upon the replicator data show that crystals with D less than 50 microns contribute significantly to the solar extinction and infrared absorption coefficients during some time intervals.

Arnott, W. P.↗

ASSESMENT OF IMPURITIES IN NP METAL USING DOUBLE-FOCUSING SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards [1]. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing [2], with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture [2]. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of na

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Covalent Bonding in f-elements using Gas-phase Ion Chemistry

Introduction In the reprocessing of f-elements present in used nuclear fuels, a variety of diglycolamides (DGA’s) are used as extractants for actinide partitioning. In particular, the Actinide-Lanthanide Separation (ALSEP) process typically utilizes either the N,N,N’,N’-tetraoctyl diglycolamide (TODGA) or N,N,N',N'-tetra-2-ethylhexyl diglycolamide (T2EHDGA) extractant ligands following the partitioning of uranium and plutonium from used nuclear fuel. To better understand fundamental interactions in these processes, covalent bonding of several f-elements with diglycolamides, primarily TODGA, is investigated in the gas phase using nanospray ionization and a quadrupole time-of-flight mass spectrometer. Further, analysis of the identity and relative strength of the cluster is enabled by MS2 isolation and collision induced dissociation. Methods Metal ion cluster analysis was completed using a Bruker mircOTOF-Q II quadrupole time-of-flight mass spectrometer equipped with a CaptiveSpray nanospray ion source. Metal:ligand solutions were prepared as 30 µM europium nitrate, samarium nitrate, cerium nitrate, or holmium nitrate and 3 µM DGA in acetonitrile or a 50:50 mixture of acetonitrile: isopropanol. Cluster mass spectra and collision-induced dissociation experiments were conducted in positive mode. Preliminary data To examine the patterns and relative strength of lanthanide: DGA interactions, MS2 experiments were completed with each lanthanide species listed above. Preliminary analyses of samarium and europium TODGA clusters suggest several combinations of TODGA and nitrate forming. The samarium cluster experiments yielded Sm(TODGA)x clusters with a samarium:TODGA ratio of up to 1:7 able to be isolated and evidence of greater ratios present in the mass spectrum. This is surprising, as metal clusters are not expected to have a coordination space able to accommodate this many ligands as large as TODGA. MS2 experiments show that, at higher ratios and with sufficient collision energy, entire TODGA ligands are removed instead of being fragmented. These experiments show that a lower collision energy is required to remove ligands as the number of bound TODGA’s increases, suggesting that in larger clusters, ligands are more delicately complexed to the metal. In addition to Sm(TODGA)x, several clusters were observed with nitrate ions bound to the metal in addition to TODGA. With a single nitrate ion, clusters with up to six TODGA’s were able to be isolated. In a similar pattern to the samarium clusters with only TODGA, less collision energy is required to eliminate one or more TODGA’s with increasing size. MS2 experiments suggest clusters with one nitrate appear to be of an equivalent or greater stability to clusters which replace the nitrate with a TODGA, as more collision energy is required to remove a TODGA ligand. These species with one nitrate are also in a higher abundance than the equivalent TODGA only cluster. With two nitrate ions, only clusters with a single TODGA were able to be isolated. Analogous europium experiments resulted in very similar clusters. Ratios of up to 1:7 Eu:TODGA were able to be isolated, and clusters with one nitrate and up to five TODGAs were isolated. In clusters with two nitrate ions, one or two TODGA’s could also be bound to the metal. MS2 experiments suggested, similarly to samarium, that larger clusters required less collision energy to eliminate TODGA. Europium clusters with one nitrate are in greater abundance and are stronger than the equivalent cluster which replaces the nitrate with TODGA. Similar analysis with cerium and holmium is ongoing, as well as analysis with other DGA ligands to compare relative strengths of the lanthanide metals with various extractant ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-Resolved Molecular Characterization of Limonene/Ozone Aerosol using High-Resolution Electrospray Ionization Mass Spectrometry

Molecular composition of limonene/O3 secondary organic aerosol (SOA) was investigated using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) as a function of reaction time. SOA was generated by ozonation of D-limonene in a reaction chamber and sampled at different time intervals using a cascade impactor. The SOA samples were extracted into acetonitrile and analyzed using a HR-ESI-MS instrument with a resolving power of 100,000 (m/Δm). The resulting mass spectra provided detailed information about the extent of oxidation inferred from the O:C ratios, double bond equivalency (DBE) factors, and aromaticity indexes (AI) in hundreds of identified individual SOA species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations of VOC Emissions and Photochemical Products over US Oil- and Gas-Producing Regions Using High-Resolution H3O+ CIMS (PTR-ToF-MS)

VOCs (Volatile Organic Compounds) related to oil and gas extraction operations in the United States were measured by H3O (sup plus) chemical ionization time-of-flight mass spectrometry (H3O (sup plus) ToFCIMS/PTR-ToF-MS (Time of Flight Chemical Ionization Mass Spectrometry/Proton Transfer Reaction-Time of Flight-Mass Spectroscopy) from aircraft during the Shale Oil and Natural Gas Nexus (SONGNEX) campaign in March-April 2015. This work presents an overview of major VOC species measured in nine oil- and gas-producing regions, and a more detailed analysis of H3O (sup plus) ToF-CIMS measurements in the Permian Basin within Texas and New Mexico. Mass spectra are dominated by small photochemically produced oxygenates and compounds typically found in crude oil: aromatics, cyclic alkanes, and alkanes. Mixing ratios of aromatics were frequently as high as those measured downwind of large urban areas. In the Permian, the H3O (sup plus) ToF-CIMS measured a number of underexplored or previously unreported species, including aromatic and cycloalkane oxidation products, nitrogen heterocycles including pyrrole (C4H5N) and pyrroline (C4H7N), H2S, and a diamondoid (adamantane) or unusual monoterpene. We additionally assess the specificity of a number of ion masses resulting from H3O (sup plus) ion chemistry previously reported in the literature, including several new or alternate interpretations.

mass spectrometr↗