Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Remote optical techniques for liquid flow and temperature measurement for Spacelab experiments

Three nonintrusive measurement techniques for Spacelab experiments are investigated. In the photochromic dye technique, a small amount of dye is dissolved in a low viscosity silicone oil and dye streaks are produced upon exposure to a UV source; the movement of the streaks reveals the flow. A laser Doppler dual-scatter system is being developed for low flow speed measurement; an accuracy of a few percent has been demonstrated for flows of a few millimeters per second. A double-grid schlieren system is being developed for temperature measurement; the optical arrangement is such that an image of a Ronchi ruling is superposed on the original ruling, giving a uniform gray field of view.

Fowlis, W. W.↗

Raman scattering measurements in flames using a tunable KrF excimer laser

A narrow-band tunable KrF excimer laser is used as a spontaneous vibrational Raman scattering source to demonstrate that single-pulse concentration and temperature measurements, with only minimal fluorescence interference, are possible for all major species (O2, N2, H2O, and H2) at all stoichiometries (fuel-lean to fuel rich) of H2-air flames. Photon-statistics-limited precisions in these instantaneous and spatially resolved single-pulse measurements are typically 5 percent, which are based on the relative standard deviations of single-pulse probability distributions. In addition to the single-pulse N2 Stokes/anti-Stokes ratio temperature measurement technique, a time-averaged temperature measurement technique is presented that matches the N2 Stokes Raman spectrum to theoretical spectra by using a single intermediate state frequency to account for near-resonance enhancement. Raman flame spectra in CH4-air flames are presented that have good signal-to-noise characteristics and show promise for single-pulse UV Raman measurements in hydrocarbon flames.

Wehrmeyer, Joseph A.↗

Transient technique for measuring heat transfer coefficients on stator airfoils in a jet engine environment

A transient technique was used to measure heat transfer coefficients on stator airfoils in a high-temperature annular cascade at real engine conditions. The transient response of thin film thermocouples on the airfoil surface to step changes in the gas stream temperature was used to determine these coefficients. In addition, gardon gages and paired thermocouples were also utilized to measure heat flux on the airfoil pressure surface at steady state conditions. The tests were conducted at exit gas stream Reynolds numbers of one-half to 1.9 million based on true chord. The results from the transient technique show good comparison with the steady-state results in both trend and magnitude. In addition, comparison is made with the STAN5 boundary layer code and shows good comparison with the trends. However, the magnitude of the experimental data is consistently higher than the analysis.

Gladden, H. J.↗

Transient technique for measuring heat transfer coefficients on stator airfoils in a jet engine environment

A transient technique was used to measure heat transfer coefficients on stator airfoils in a high-temperature annular cascade at real engine conditions. The transient response of thin film thermocouples on the airfoil surface to step changes in the gas stream temperature was used to determine these coefficients. In addition, gardon gages and paired thermocouples were also utilized to measure heat flux on the airfoil pressure surface at steady state conditions. The tests were conducted at exit gas stream Reynolds numbers of one-half to 1.9 million based on true chord. The results from the transient technique show good comparison with the steady-state results in both trend and magnitude. In addition, comparison is made with the STAN5 boundary layer code and shows good comparison with the trends. However, the magnitude of the experimental data is consistently higher than the analysis.

Gladden, H. J.↗

A technique for measuring vertically and horizontally polarized microwave brightness temperatures using electronic polarization-basis rotation

This technique for electronically rotating the polarization basis of an orthogonal-linear polarization radiometer is based on the measurement of the first three feedhorn Stokes parameters, along with the subsequent transformation of this measured Stokes vector into a rotated coordinate frame. The technique requires an accurate measurement of the cross-correlation between the two orthogonal feedhorn modes, for which an innovative polarized calibration load was developed. The experimental portion of this investigation consisted of a proof of concept demonstration of the technique of electronic polarization basis rotation (EPBR) using a ground based 90-GHz dual orthogonal-linear polarization radiometer. Practical calibration algorithms for ground-, aircraft-, and space-based instruments were identified and tested. The theoretical effort consisted of radiative transfer modeling using the planar-stratified numerical model described in Gasiewski and Staelin (1990).

Gasiewski, Albin J.↗

New two-dimensional space-resolving flux detection technique for measurement of hohlraum inner radiation in Shenguang-III prototype

The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Investigation of a Photographic Technique of Measuring High Surface Temperatures

A photographic method of temperature determination has been developed to measure elevated temperatures of surfaces. The technique presented herein minimizes calibration procedures and permits wide variation in emulsion developing techniques. The present work indicates that the lower limit of applicability is approximately 1,400 F when conventional cameras, emulsions, and moderate exposures are used. The upper limit is determined by the calibration technique and the accuracy required.

Siviter, James H., Jr.↗

Impact of impurities on the α-LiIO{sub 3} crystal growth: Technique for measuring the “dead zone”

Lithium iodate (α-LiIO{sub 3}) single crystal is a promising nonlinear optical material, which used for efficient laser radiation conversion in the visible and near-IR regions. A technique for measuring the “dead zone” (ΔТ{sub dz}) of LiIO{sub 3} solutions has been developed; data on the impact of Fe(IO{sub 3}){sub 2}, AgIO{sub 3}, CsOH, H{sub 3}PO{sub 4}, and methyl methacrylate on the growth of the (100) face of α-LiIO{sub 3} crystals have been presented; and the dependences of the nucleation and motion of single steps on the degree of supersaturation have been measured. It is shown that the ΔТ{sub dz} value makes it possible to estimate the validity of solutions for growing α-LiIO{sub 3} crystals. The results of measuring the face growth rates and step velocities for KDP and α-LiIO{sub 3} crystals are compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Error Vector Magnitude (EVM) to Characterize the Impairment of the Tracking and Data Relay Satellite (TDRS) Channel

A digital signal is transmitted via a carrier wave, it demodulates at a receiver, and locates at an ideal constellation point. However, noise distortion, carrier leakage, and phase noise can force a signal to divert from its ideal position to a new position. Consequently, the performance of the signal is decreased. Bit Error Rate (BER) and Error Vector Magnitude (EVM) measurement techniques are used to enable the analysis and assessment of the extent to which the performance of a signal has been decreased. In this paper, we present the EVM measurement technique as a figure of merit to analyze and evaluate the performance of a User Services Subsystem Component Replacement (USSCR) modem. Also, we demonstrate the use of the EVM measurement technique in a Tracking and Data Relay Satellite (TDRS) system to measure and evaluate channel impairment between a satellite (transmitter) and the ground terminal (receiver) at the White Sands Complex.

Spacecraft RF Communications↗

Laser-Induced Thermal Acoustic Measurements in a Highly Back-Pressured Scramjet Isolator Model: A Research Plan

Under the Propulsion Discipline of NASA s Fundamental Aeronautics Program s Hypersonics Project, a test apparatus, for testing a scramjet isolator model, is being constructed at NASA's Langley Research Center. The test apparatus will incorporate a 1-inch by 2-inch by 15-inch-long scramjet isolator model supplied with 2.1 lbm/sec of unheated dry air through a Mach 2.5 converging-diverging nozzle. The planned research will incorporate progressively more challenging measurement techniques to characterize the flow field within the isolator, concluding with the application of the Laser-Induced Thermal Acoustic (LITA) measurement technique. The primary goal of this research is to use the data acquired to validate Computational Fluid Dynamics (CFD) models employed to characterize the complex flow field of a scramjet isolator. This paper describes the test apparatus being constructed, pre-test CFD simulations, and the LITA measurement technique.

Middleton, Troy F.↗

The Development and Hover Test Application of a Projection Moire Interferometry Blade Displacement Measurement System

Projection moir interferometry (PMI) was employed to measure blade deflections during a hover test of a generic model-scale rotor in the NASA Langley 14x22 subsonic wind tunnel s hover facility. PMI was one of several optical measurement techniques tasked to acquire deflection and flow visualization data for a rotor at several distinct heights above a ground plane. Two of the main objectives of this test were to demonstrate that multiple optical measurement techniques can be used simultaneously to acquire data and to identify and address deficiencies in the techniques. Several PMI-specific technical challenges needed to be addressed during the test and in post-processing of the data. These challenges included developing an efficient and accurate calibration method for an extremely large (65 inch) height range; automating the analysis of the large amount of data acquired during the test; and developing a method to determinate the absolute displacement of rotor blades without a required anchor point measurement. The results indicate that the use of a single-camera/single-projector approach for the large height range reduced the accuracy of the PMI system compared to PMI systems designed for smaller height ranges. The lack of the anchor point measurement (due to a technical issue with one of the other measurement techniques) limited the ability of the PMI system to correctly measure blade displacements to only one of the three rotor heights tested. The new calibration technique reduced the data required by 80 percent while new post-processing algorithms successfully automated the process of locating rotor blades in images, determining the blade quarter chord location, and calculating the blade root and blade tip heights above the ground plane.

Sekula, Martin K.↗

Comparisons of techniques for measurement of D-region electron densities

This paper reviews the ground-based and rocket techniques that are presently being used to determine electron density profiles in the ionospheric D region. Ground-based techniques include VLF, LF, and MF sounding; differential absorption and differential phase measurements using partial reflections; wave interaction; and incoherent scatter. Rocket techniques include differential absorption and Faraday rotation in association with high-resolution dc probes calibrated by means of the radio measurements. The characteristics of the aforementioned techniques are presented, including time and height resolution, accuracy estimates, preferred height ranges, and problems encountered. Electron density profiles obtained with these techniques are presented for comparable solar zenith angles and undisturbed solar and geophysical conditions.

Sechrist, C. F., Jr.↗

Approach to Precision and Bias Analysis of Interlaboratory Salt Study Results

An interlaboratory study of salt properties measurements was initiated in 2020 by Raluca Scarlatt of UC Berkley and Jake McMurray of Oak Ridge National Laboratory as a DOE-funded NEUP project. The objective of what is referred to as the interlaboratory salt study (ISS) was to assess the quality of molten salt property data and develop consensus standard methods for measuring key property values. Unlike many interlaboratory studies in which the precision of applying a well-defined and well-constrained method is measured, the methods used to measure property values were not specified nor were the measurement conditions controlled. Instead, the approach was to engage participants in measuring the property values of two commonly-used salt mixtures by using any desired measurement techniques. By including measurements made using the same and different methods across institutions, the precisions achieved using specific techniques can be assessed as well as the confidence in the values measured using different techniques. Details of the calibrations and uncertainty provided by the participants will be useful in establishing a best practice for the application of each technique to molten salts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressure and force measurements on models set in hypersonic flows: A review

A review of measurement techniques used to obtain aerodynamic forces and moments and surface/flow field pressures for models tested in impulse hypersonic-hypervelocity facilities and in conventional-type hypersonic wind tunnels is presented. Although force and moment measurement techniques presently used in hypersonic wind tunnels are relatively unchanged from the 1960's and 1970's, significant advances have recently been made for impulse facilities. For both hypersonic wind tunnels and impulse facilities, the state-of-the-art has advanced via refinements, improved test techniques, and advances in semiconductor technology, data acquisition systems, and computers. The introduction of electronically scanned pressure systems over a decade ago 'revolutionized' pressure measurements in hypersonic wind tunnels and a second 'revolution' is impending with the development and application of optical, two-dimensional, global pressure measurement techniques. The development and continued refinement of miniature piezoresistive transducers has provided the capability to perform detailed surface pressure measurements on relatively small, complex models in impulse facilities; these transducers also provided the capability for intrusive flow field pressure measurements with miniature survey rakes.

Miller, Charles G.↗

A Technique for Measuring Rotocraft Dynamic Stability in the 40 by 80 Foot Wind Tunnel

An on-line technique is described for the measurement of tilt rotor aircraft dynamic stability in the Ames 40- by 80-Foot Wind Tunnel. The technique is based on advanced system identification methodology and uses the instrumental variables approach. It is particulary applicable to real time estimation problems with limited amounts of noise-contaminated data. Several simulations are used to evaluate the algorithm. Estimated natural frequencies and damping ratios are compared with simulation values. The algorithm is also applied to wind tunnel data in an off-line mode. The results are used to develop preliminary guidelines for effective use of the algorithm.

Gupta, N. K.↗

Criteria for electrically heated temperature probes in flames.

Measurement techniques proposed by Gilbert and Lobdell (1953) and Rein and O'Laughlin (1967) are considered, giving attention to an apparent paradox. The criteria under which the assumptions made for the measurement techniques apply are specified. If sensors of different diameters are tested and the resultant plots of the parameter ?S' vs the wire temperature intersect below the abscissa, the considered measurement techniques are not applicable.

Miller, I. M.↗

Techniques for Measuring Surface Potentials in Space

Materials exposed to the space plasma environment charge to a net potential relative to the ambient plasma. The charging process is due to differential currents to the material surface that results in a net surface charge density. While this process is termed "spacecraft surface charging" when applied to aerospace hardware, it also applies to the surfaces of astronomical objects in direct contact with the space plasma environment including a number of planetary bodies, asteroids, and dust particles. The ability to measure surface potentials is important to many techniques used in conducting fundamental heliospheric science, spacecraft engineering operations, and space technology development activities. This presentation provides a survey of current technologies used to measure surface potentials of spacecraft and planetary bodies with examples of their application to space science and technology programs.

Minow, Joseph I.↗