Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Coastal-Fog Microphysics Using In-Situ Observations and GOES-R Retrievals

Here, the objective of this work is to evaluate GOES-R based fog conditions occurred during the C-FOG (Toward Improving Coastal Fog Prediction) field campaign. C-FOG is designed to advance understanding of fog formation, development, and dissipation over coastal environments to improve its predictability. The project took place along coastlines and open water environments of Eastern Canada (Nova Scotia, NS and the Island of Newfoundland, NL) during August-October of 2018 where environmental conditions play an important role for late season’s fog formation. During the C-FOG field campaign, instruments were located at the Ferryland Supersite, NL, with 2 main sites, and five satellite sites, as well as on the Research Vessel (R/V) Hugh R. Sharp. Key measurement instruments included a Gondola carrying a CDP (cloud droplet probe) and a BCP (backscatter cloud probe) was used for measuring droplet spectra from 1-75 µm on the R/V. A LPM (laser precipitation monitor) with 100 µm-1 cm size range and an OPC (optical particle counter) with 0.3-17 µm at 16 spectral channels provided information for fog and drizzle discrimination. Remote sensing platforms (e.g. profiling microwave radiometer, PMWR), Ceilometer, Lidar), meteorological towers, tethered balloons, and GOES-R products (e.g. fog coverage and droplet size and liquid water path) were used to evaluate fog over horizontal and vertical dimensions. Results suggest that effective radius, phase, liquid water path, and liquid water content values obtained from GOES-R and PMWR were comparable to ground based in-situ observations. It is concluded that integration of observations and nowcasting products may help improve short term local fog predictions.

54 ENVIRONMENTAL SCIENCES↗

Portable Airflow Meter

Compact hand-held instrument measures airflow. Consists of hot-wire anemometer probe in flow-straightening tube that reduces swirling. Configuration developed empirically to reduce length of instrument to practical dimension for use and storage in confined space. Two versions of new straightener only 17 and 18 in. long. Weighs less than 8 lb. and readily stored on Space Shuttle, developed to measure airflow in waster-collection system during flight. Used on Earth to measure airflow in ventilation systems, vacuum cleaners, and the like.

Burgett, Frank A.↗

EPCAPE-Dalhousie Field Campaign Report

This project supported the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), which aimed to characterize the extent, radiative properties, aerosol interactions, and precipitation of stratocumulus clouds in the Eastern Pacific coastal region of La Jolla, California. Given the frequent anthropogenic aerosols emitted into this region, characterization of this important coastal cloud region and the aerosol impact on the cloud characteristics will improve the understanding of aerosol indirect effects and its representation in global climate models. This specific project deployed the fog droplet monitor (FM-120, Droplet Measurement Technologies) at the Scripps Institution of Oceanography’s Mt. Soledad site from 16 February 2023 to 15 February 2024. This instrument measured droplet number size spectra between 2 and 50 microns, from which droplet number concentration, liquid water content, and effective diameter were calculated. These measurements will be used to characterize the seasonal variability of clouds at Mt. Soledad and investigate differences in cloud properties under regional polluted and clean marine conditions. The collected data will soon be posted as part of the digital collection for EPCAPE data hosted by the University of California, San Diego (Russell et al. 2023).

54 ENVIRONMENTAL SCIENCES↗

Development of Real-Time Coal Monitoring Instrument

Relying on coal for energy requires optimizing the extraction of heat content from various blends of coal fuel and reducing harmful constituents and byproducts. Having a real-time measurement instrument provides relevant information about toxic constituents released in the atmosphere from burning coal and optimizes the performance of a power plant. A few commercial instruments exist and have been in operation for more than a decade. However, most of these instruments are based on radioactive sources and are bulky, expensive and time-consuming. The proposed instrument is based on the Laser Induced Breakdown Spectroscopy (LIBS). The advantage of LIBS is that it is a standoff instrument, does not require sample preparation and provides precise information about sample constituents.

01 COAL, LIGNITE, AND PEAT↗

An extension of the dual magnetometer method for use on a dual spinning spacecraft

A method of estimating and correcting for the magnetic field of a dual spinning spacecraft has been developed by employing an extension of the dual magnetometer technique of Ness et al. (1971). This new method is useful for those situations in which a magnetometer boom of modest length (7-10 m) is attached to the spinning part of a large spacecraft (800-1000 kg). The purpose of using a dual spinning spacecraft is to accommodate two types of instruments: (1) imaging and similar 'pointed' remote sensing systems on the stationary platform and (2) fields, particles, and other in situ measuring instruments on the spinning portion. Present-day imaging systems are well known to exhibit large magnetic moments, sometimes displaced from the spacecraft center by a significant amount. The new method assumes that the stationary part of the spacecraft possesses a magnetic field which is represented by a combination of a dipole and a quadrupole field.

Lepping, R. P.↗

Goldstone field test activities: Sky survey

The goals are to conduct a research and development program aimed at determining the most effective way to do SETI within the constraints of current technology and estimated budgets. The general search strategy adopted is that which is recommended by the SETI Science Working Group. The strategy for an all sky survey for SETI was further developed over the last year. Scan patterns, scan rates, and signal detection algorithms were developed. Spectral power measurement instrumentation was tested at the Venus Station of the Goldstone Deep Space Communication Complex. A specially designed radio frequency interference (RFI) measurement system was built and installed at the Venus Station. A data base management system for storage and retrieval of the RFI data was partially implemented on a VAX 750 computer at the Jet Propulsion Laboratory.

Gulkis, S.↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Safeguards Verification Measurements using Laser Ablation, Absorbance Ratio Spectrometry in Gaseous Centrifuge Enrichment Plants

Laser Ablation Absorbance Ratio Spectrometry (LAARS) is a new verification measurement technology under development at the US Department of Energy’s (DOE) Pacific Northwest National Laboratory (PNNL). LAARS uses three lasers to ablate and then measure the relative isotopic abundance of uranium compounds. An ablation laser is tightly focused on uranium-bearing solids producing a small plume containing uranium atoms. Two collinear wavelength-tuned spectrometry lasers transit through the plume and the absorbance of U-235 and U-238 isotopes are measured to determine U-235 enrichment. The measurement has high relative precision and detection limits approaching the femtogram range for uranium. It is independent of chemical form and degree of dilution with nuisance dust and other materials. High speed sample scanning and pinpoint characterization allow measurements on millions of particles/hour to detect and analyze the enrichment of trace uranium in samples. The spectrometer is assembled using commercially available components at comparatively low cost, and features a compact and low power design. Future designs can be engineered for reliable, autonomous deployment within an industrial plant environment. Two specific applications of the spectrometer are under development: 1) automated unattended aerosol sampling and analysis and 2) on-site small sample destructive assay measurement. The two applications propose game-changing technological advances in gaseous centrifuge enrichment plant (GCEP) safeguards verification. The aerosol measurement instrument, LAARS-environmental sampling (ES), collects aerosol particles from the plant environment in a purpose-built rotating drum impactor and then uses LAARS-ES to quickly scan the surface of the impactor to measure the enrichments of the captured particles. The current approach to plant misuse detection involves swipe sampling and offsite analysis. Though this approach is very robust it generally requires several months to obtain results from a given sample collection. The destructive assay instrument, LAARS-destructive assay (DA), uses a simple purpose-built fixture with a sampling planchet to collect adsorbed UF6 gas from a cylinder valve or from a process line tap or pigtail. A portable LAARS-DA instrument scans the microgram quantity of uranium collected on the planchet and the assay of the uranium is measured to ~0.15% relative precision. Currently, destructive assay samples for bias defect measurements are collected in small sample cylinders for offsite mass spectrometry measurement.

Enrichment Monitoring↗

Cloud Uniformity Measurement from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

Cloud Uniformity Measurements from NASA's 2nd Fundamental Ice Crystal Icing Test Part 1 (Water Content & PSD)

This paper presents water content and particle measurements from the second Fundamental Ice Crystal Icing Physics test conducted in the NASA Propulsion Systems Laboratory. The water content measurements came from the Science Engineering Associates Multi-Element Probe and the Isokinetic Probe whereas the Artium Technologies, Inc. Phase Doppler Interferometer and High Speed Imaging instruments measured the particle size distribution. Ice particle accretion due to the ingestion of ice-crystals is attributed to numerous jet engine powerloss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. This work focuses on characterizing the icing cloud by traversing the instruments across the test section at four different conditions where velocity and water content were varied. For this test, the nozzle patterns were selected to make a uniform cloud in the center 6-inch diameter of the test section. Radial trends for the ice and water content measurements are presented and the melt ratio is calculated at the measurement locations. Particle size distributions are also presented. The measured water content, melt ratio, and particle size decreased moving out radially. Measured water content trends show uniformity to within 19.2% for the center 6 inches of the cloud, as intended. In addition, the total water content increased at centerline with velocity, whereas the melt ratio decreased.

Ice-Crystal Icing↗

The OASIS Mission

The Orbiting Astrophysical Observatory in Space (OASIS) is a mission to investigate Galactic Cosmic Rays (GCRs), a major feature of our galaxy. OASIS will use measurements of GCRs to determine the cosmic ray source, where they are accelerated, to investigate local accelerators and to learn what they can tell us about the interstellar medium and the processes that occur in it. OASIS will determine the astrophysical sources of both the material and acceleration of GCRs by measuring the abundances of the rare actinide nuclei and make direct measurements of the spectrum and anisotropy of electrons at energies up to approx.10 TeV, well beyond the range of the Fermi and AMS missions. OASIS has two instruments. The Energetic Trans-Iron Composition Experiment (ENTICE) instrument measures elemental composition. It resolves individual elements with atomic number (Z) from 10 to 130 and has a collecting power of 60m2.str.yrs, >20 times larger than previous instruments, and with improved resolution. The sample of 10(exp 10) GCRs collected by ENTICE will include .100 well-resolved actinides. The High Energy Particle Calorimeter Telescope (HEPCaT) is an ionization calorimeter that will extend the electron spectrum into the TeV region for the first time. It has 7.5 sq m.str.yrs of collecting power. This talk will describe the scientific objectives of the OASIS mission and its discovery potential. The mission and its two instruments which have been designed to accomplish this investigation will also be described.

Adams, James H., Jr.↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

aosacsm.b1

ACSM instrument measure mass loading (ug/m3) of non-refractory aerosol particles particularly organics, sulfate, chlorides, ammonium, and nitrates in real-time. The instrument is run autonomously at various ARM sites at time resolution equal to 30 minutes. Different data products are developed. The raw data (.itx and .asc) files are ingested to produce the.a0 product - the first netCDF file. These raw files are used by the mentor to calculate the mentor processed mass loadings. The .a0 files are used to develop the .b1 level product. The .b1 level data is further integrated with mentor processed data to produce .c0 level data product.

54 ENVIRONMENTAL SCIENCES↗

aosacsm.a0

ACSM instrument measure mass loading (ug/m3) of non-refractory aerosol particles particularly organics, sulfate, chlorides, ammonium, and nitrates in real-time. The instrument is run autonomously at various ARM sites at time resolution equal to 30 minutes. Different data products are developed. The raw data (.itx and .asc) files are ingested to produce the.a0 product - the first netCDF file. These raw files are used by the mentor to calculate the mentor processed mass loadings. The .a0 files are further used to develop the .b1 level product.

54 ENVIRONMENTAL SCIENCES↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

ROCOZ-A (improved rocket launched ozone sensor) for middle atmosphere ozone measurements

An improved interference filter based ultraviolet photometer (ROCOZ-A) for measuring stratospheric ozone is discussed. The payload is launched aboard a Super-Loki to a typical apogee of 70 km. The instrument measures the solar ultraviolet irradiance as it descends on a parachute. The total cumulative ozone is then calculated based on the Beer-Lambert law. The cumulative ozone precision measured in this way is 2.0% to 2.5% over an altitude range of 20 and 55 km. Results of the intercomparison with the SBUV overpass data and ROCOZ-A data are also discussed.

Lee, H. S.↗

TRITIUM UNCERTAINTY ANALYSIS FOR SURFACE WATER SAMPLES AT THE SAVANNAH RIVER SITE

Radiochemical analyses of surface water samples, in the framework of Environmental Monitoring, have associated uncertainties for the radioisotopic results reported. These uncertainty analyses pertain to the tritium results from surface water samples collected at five locations on the Savannah River near the U.S. Department of Energy's Savannah River Site (SRS). Uncertainties can result from the field-sampling routine, can be incurred during transport due to the physical properties of the sample, from equipment limitations, and from the measurement instrumentation used. The uncertainty reported by the SRS in their Annual Site Environmental Report currently considers only the counting uncertainty in the measurements, which is the standard reporting protocol for radioanalytical chemistry results. The focus of this work is to provide an overview of all uncertainty components associated with SRS tritium measurements, estimate the total uncertainty according to ISO 17025, and to propose additional experiments to verify some of the estimated uncertainties. The main uncertainty components discovered and investigated in this paper are tritium absorption or desorption in the sample container, HTO/H{sub 2}O isotopic effect during distillation, pipette volume, and tritium standard uncertainty. The goal is to quantify these uncertainties and to establish a combined uncertainty in order to increase the scientific depth of the SRS Annual Site Environmental Report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗