Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Linear Algebraic Method for Non-Linear Map Analysis

We present a newly developed method to analyze some non-linear dynamics problems such as the Henon map using a matrix analysis method from linear algebra. Choosing the Henon map as an example, we analyze the spectral structure, the tune-amplitude dependence, the variation of tune and amplitude during the particle motion, etc., using the method of Jordan decomposition which is widely used in conventional linear algebra.

43 PARTICLE ACCELERATORS↗

The COMET method in 3-D hexagonal geometry

The hybrid stochastic-deterministic coarse mesh radiation transport (COMET) method developed at Georgia Tech now solves reactor core problems in 3-D hexagonal geometry. In this paper, the method is used to solve three preliminary test problems designed to challenge the method with steep flux gradients, high leakage, and strong asymmetry and heterogeneity in the core. The test problems are composed of blocks taken from a high temperature test reactor benchmark problem. As the method is still in development, these problems and their results are strictly preliminary. Results are compared to whole core Monte Carlo reference solutions in order to verify the method. Relative errors are on the order of 50 pcm in core eigenvalue, and mean relative error in pin fission density calculations is less than 1% in these difficult test cores. The method requires the one-time pre-computation of a response expansion coefficient library, which may be compiled in a comparable amount of time to a single whole core Monte Carlo calculation. After the library has been computed, COMET may solve any number of core configurations on the order of an hour, representing a significant gain in efficiency over other methods for whole core transport calculations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of Wellbore Leakage Risk Using Non-destructive Borehole Logging Techniques

Well integrity is important at all potential CCS locations and may play a crucial role establishing leakage risk in areas where there is a high density of existing wells that could be impacted by the storage operations including depleted petroleum fields where EOR or CCS will occur. To address a need for risk quantification methods that can be directly applied to individual wells using borehole logging tools a study was conducted using data from five wells in Wyoming. The objectives of the study were: Objective 1: Develop methods to establish the baseline flow parameters (porosity and permeability or mobility) from individual measurements of the material properties and defects in a well. Objective 2: Develop a correlation between field flow-property data and cement logs that can be used to establish the flow-properties of well materials and well features using cement mapping tools. Objective 3: Establish a method that uses the flow-property model (Objective 2) to analyze the statistical uncertainties associated with individual well leakage that can provide basis for uncertainty in risk calculations. The project objectives were met through the logging of five wells in Carbon and Natrona County Wyoming to collect data that was used to estimate individual and average well flow properties and model the results using ultrasonic data collected during the logging. Three of the five wells provided data on point and average flow properties for well annuli. Data from the other two wells were used to create models of cement permeability and test whether information collected in one well could be used to characterize another well. The results of the in-situ point measurements were confirmed by the lab measurements sidewall cores collected near the same depths Objective 1 was met using the data collected through logging, testing, and sampling. The methods were developed that can establish baseline flow parameters of wells by both point and average test methods. The methods to estimate the flow properties modeling of point pressure tests, modeling of vertical interference tests, and laboratory measurement of cased-hole sidewall cores The wells were in sufficiently good shape to allow the development of the characterization methods while still having enough defects to study differences in results as they relate to well integrity. Samples and tests analyzed from three of five wells studied in showed the cements were largely intact and had not degraded from exposure native brines. Log results taken in conjunction with the core measurements indicate that interfaces and/or problems with cement placement due to eccentering provide preferential flow paths for fluids, which can increase the effective permeability of the barrier several orders of magnitude above the permeability of intact cement. The results of the maps created using logging tools indicating that the cement condition and bond are generally good identify a need for more research to understand how logs can be used to predicteffective well permeabilities such as those measured by the VITs in this study.

42 ENGINEERING↗

LONG TERM OPERATION ISSUES FOR ELECTRICAL CABLE SYSTEMS IN NUCLEAR POWER PLANTS

Nuclear power plants contain hundreds of kilometers of electrical cables including cables used for power, for instrumentation, and for control. It is essential that safety-related cable systems continue to perform following a design-basis event. Wholesale replacement of electrical cables in existing plants facing licensing period renewal is both impractical and cost-prohibitive. It is therefore important to understand the long term aging of cable materials to have confidence that aged cables will perform when needed. It is equally important in support of cable aging management to develop methods to evaluate the health of installed cables and inform selective cable replacement decisions. The most common insulation materials for electrical cables in nuclear power plants are cross-linked polyethylene and ethylene-propylene rubber. The mechanical properties of these materials degrade over time in the presence of environmental stresses including heat, gamma irradiation, and moisture. Mechanical degradation of cable insulation beyond a certain threshold is unacceptable because it can lead to insulation cracking, exposure of energized conductors, arcing and burning or loss of the ability of the cable system to function during a design-basis accident. While thermal-, radiation-, and moisture-related degradation of polymer insulation materials has been extensively studied over the last few decades, questions remain regarding the long-term performance of cable materials in nuclear plant-specific environments. Identified knowledge gaps include an understanding of the temperature-dependence of activation energies for thermal damage and an understanding of the synergistic effects of radiation and thermal stress on polymer degradation. Many of the outstanding questions in the aging behavior of cable materials relate to the necessity of predicting long-term field degradation using accelerated aging results from the laboratory. Materials degrade faster under more extreme conditions, but extension of behavior to long term degradation under more mild conditions, such as those experienced by most installed cables in nuclear power plants, is complicated by the fact that different degradation mechanisms may be involved in extreme and mild scenarios. The discrepancy in predicted results from short term, more extreme exposure and actual results from longer term, more mild exposures can be counter intuitive. For instance, due to the attenuation of oxidation penetration in material samples rapidly aged through exposure to high temperatures, the bulk of the samples may be artificially protected from thermal aging. In another example, simultaneous exposure of cable insulation material to heat and radiation may actually lead to less damage at higher temperatures than may be observed at lower temperatures. The Light Water Reactor Sustainability program of the United States (US) Department of Energy Office (DOE) of Nuclear Energy is funding research to increase the predictive understanding of electrical cable material aging and degradation in existing nuclear power plants in support of continued safe operation of plants beyond their initial license periods. This research includes the evaluation and development of methods to assess installed cable condition.

Fifield, Dr Leonard S↗

Direct Numerical Simulation of Pore-Scale Flow in a Bead Pack: Comparison with Magnetic Resonance Imaging Observations

A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental error in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods.

computational fluid dynamics↗

DIONEX ICS3000 ION CHROMATOGRAPHY SYSTEM INSTALLATION AND INSTRUMENT ASSESSMENT FOR SRNL APPLICATIONS

Ion Chromatography (IC) is routinely used at the Savannah River National Laboratory (SRNL) for sample analysis and characterization. Results from IC analysis are valued in corrosion control maintenance and measurement programs, remediation waste process control, soil and ground water measurement, nuclear materials processing, and various other research and development programs. Presented in this report are analytical methods developed on a DIONEX ICS3000 Reagent Free Ion Chromatography (RFIC) system located in AD at SRNL. This IC system contains two independent analysis channels comprising of a mobile phase generator, a pump, stationary phase columns, a suppressor and a conductivity detector. One channel is dedicated to anion analysis using Potassium Hydroxide (KOH) as the mobile phase while a second channel is configured for cation analysis using Methanesulfonic Acid (MSA) as the mobile phase. Both channels share an autosampler and the peak analysis software, Chromeleon{reg_sign} v.6.8. Instrument configuration is modified from the manufacturer for radiological service. Listed within this report are Dionex ICS3000 parameters and results for the analysis of routine anions and cations. Additional method parameters and discussion are presented on the analysis of Acetate (CH{sub 3}COO{sup -}) and Iodate (IO{sub 3}{sup -}). Previous IC analysis instruments at AD have been based upon carbonate/bicarbonate buffer mobile phase chemistry. This report represents a transition to hydroxide as a mobile phase eluent. The hydroxide eluent offers a lower baseline conductivity, which allows for greater sample dilution and/or lower detection limits. Also the hydroxide mobile phase and column set has a significant separation of the phosphate peak from the nitrate and sulfate peaks vs. the carbonate/bicarbonate mobile phase and column set, an advantage for the industrial waste analyzed at SRNL.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Current State of Radiation Dosimetry in Radionuclide Therapy

Radionuclide therapy combines the specificity of cancer cell targeting with the well-known cytotoxic effects of ionizing radiation. It has the potential to simultaneously eradicate both the primary tumor site as well as the metastatic extent of the disease throughout the body. Despite these advantages, a major limitation of radionuclide therapy is that conventional internal dosimetry methods have failed to accurately predict treatment outcomes in patients. It has been proposed that this shortcoming is due to the fact that therapeutic dosimetry is typically performed using methods developed for diagnostic imaging that do not consider patient specific anatomy, pharmacokinetics and dose heterogeneity. Even worse, dosimetry methods are often completely neglected during treatment planning and dose prescription is based on Body Surface Area/Weight (BSA/BW) and platelet counts. The most widely used internal dosimetry software is OLINDA/EXM (Organ Level Internal Dose Assessment for Exponential Modeling). OLINDA/EXM calculates absorbed doses using the formulism developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine. In its current implementation, OLINDA/EXM requires the use of S factors, which are derived in phantoms that do not accurately represent the actual patient. In addition, OLINDA/EXM assumes that the activity distribution in each organ and tumor is uniform, when it has been well established that activity distributions are often highly heterogeneous. Furthermore, the tumor is not modeled in the phantom, which introduces additional uncertainties in the calculation. Due to these limitations, there is a clear need for improved dosimetry methods for therapeutic nuclear medicine that utilize patient-specific imaging information. A variety of efforts are currently underway to develop such methods. There are two commercial software packages on the market for voxel level internal dosimetry: STRATOS (Philips Technologies, Aachen, Germany) and VoxelDose (DosiSoft, Cachan, France), but both packages are not widely used in clinical practice. In addition, several academic platforms have been developed. Similar to these offerings, RAPID is a robust, fast and multimodal platform. However, RAPID has been designed with tremendous flexibility to perform accurate dosimetry for any radiopharmaceutical in the pre-clinical and clinical setting in order to aid in drug development and to assist in radionuclide therapy treatment planning. This presentation will overview existing dosimetry platforms while focusing on the Monte Carlo-based platform developed at the University of Wisconsin known as RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID is a robust and universal platform that can provide accurate 3D internal dosimetry for any radiopharmaceutical during both the pre-clinical and clinical stages of drug development as well as clinical treatment planning in TRT. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Error analysis for semi-analytic displacement derivatives with respect to shape and sizing variables

Sensitivity analysis is fundamental to the solution of structural optimization problems. Consequently, much research has focused on the efficient computation of static displacement derivatives. As originally developed, these methods relied on analytical representations for the derivatives of the structural stiffness matrix (K) with respect to the design variables (b sub i). To extend these methods for use with complex finite element formulations and facilitate their implementation into structural optimization programs using the general finite element method analysis codes, the semi-analytic method was developed. In this method the matrix the derivative of K/the derivative b sub i is approximated by finite difference. Although it is well known that the accuracy of the semi-analytic method is dependent on the finite difference parameter, recent work has suggested that more fundamental inaccuracies exist in the method when used for shape optimization. Another study has argued qualitatively that these errors are related to nonuniform errors in the stiffness matrix derivatives. The accuracy of the semi-analytic method is investigated. A general framework was developed for the error analysis and then it is shown analytically that the errors in the method are entirely accounted for by errors in delta K/delta b sub i. Furthermore, it is demonstrated that acceptable accuracy in the derivatives can be obtained through careful selection of the finite difference parameter.

Fenyes, Peter A.↗

Bayesian Inference for Time Trends in Parameter Values: Case Study for the Ageing PSA Network of the European Commission

There is a nearly ubiquitous assumption in PSA that parameter values are at least piecewise-constant in time. As a result, Bayesian inference tends to incorporate many years of plant operation, over which there have been significant changes in plant operational and maintenance practices, plant management, etc. These changes can cause significant changes in parameter values over time; however, failure to perform Bayesian inference in the proper time-dependent framework can mask these changes. Failure to question the assumption of constant parameter values, and failure to perform Bayesian inference in the proper time-dependent framework were noted as important issues in NUREG/CR-6813, performed for the U. S. Nuclear Regulatory Commission’s Advisory Committee on Reactor Safeguards in 2003. That report noted that “industry lacks tools to perform time-trend analysis with Bayesian updating.” This paper describes an application of time-dependent Bayesian inference methods developed for the European Commission Ageing PSA Network. These methods utilize open-source software, implementing Markov chain Monte Carlo sampling. The paper also illustrates the development of a generic prior distribution, which incorporates multiple sources of generic data via weighting factors that address differences in key influences, such as vendor, component boundaries, conditions of the operating environment, etc.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of the Need for and Design of a City Energy Operations System

There is growing interest in city and community scale energy efficiency goals across the US and around the world [1]. Forward thinking developers are expressing interest in developing methods to track the actual operations of new urban developments and campuses. Local governments and developers are exploring how to ensure that the built infrastructure, including buildings, transportation, energy generation and storage assets, is not only designed for energy efficiency, but operates efficiently as well. There is a need for city and district scale tools to support energy analysis from design through operations. Smart city data analytics is a growing area of interest in the smart city technology space. However, while there is enthusiasm for the concept of smart city energy analytics, there is a lack of common semantic data models, interoperable systems, and methods to collect data and support decision-making for operating multi-building city- and district-scale energy systems. Urban developers are asking broad questions about how such a system might be designed, built, valued, maintained, and optimized. This paper describes ongoing research to explore and define a City or District Energy Operations System (CityEOS).

Piette, Mary Ann↗

Development of a rapid culture method to induce adipocyte differentiation of human bone marrow-derived mesenchymal stem cells

Human mesenchymal stem cells (hMSCs) derived from bone marrow are multipotent stem cells that can regenerate mesenchymal tissues such as adipose, bone or muscle. It is thought that hMSCs can be utilized as a cell resource for tissue engineering and as human models to study cell differentiation mechanisms, such as adipogenesis, osteoblastogenesis and so on. Since it takes 2-3 weeks for hMSCs to differentiate into adipocytes using conventional culture methods, the development of methods to induce faster differentiation into adipocytes is required. In this study we optimized the culture conditions for adipocyte induction to achieve a shorter cultivation time for the induction of adipocyte differentiation in bone marrow-derived hMSCs. Briefly, we used a cocktail of dexamethasone, insulin, methylisobutylxanthine (DIM) plus a peroxisome proliferator-activated receptor {gamma} agonist, rosiglitazone (DIMRo) as a new adipogenic differentiation medium. We successfully shortened the period of cultivation to 7-8 days from 2-3 weeks. We also found that rosiglitazone alone was unable to induce adipocyte differentiation from hMSCs in vitro. However, rosiglitazone appears to enhance hMSC adipogenesis in the presence of other hormones and/or compounds, such as DIM. Furthermore, the inhibitory activity of TGF-{beta}1 on adipogenesis could be investigated using DIMRo-treated hMSCs. We conclude that our rapid new culture method is very useful in measuring the effect of molecules that affect adipogenesis in hMSCs.

60 APPLIED LIFE SCIENCES↗

Mechanistic insights into metal, nitrogen doped carbon catalysts for oxygen reduction: progress in computational modeling

We report metal and nitrogen doped carbon materials (denoted as M–N–C) synthesized through high-temperature pyrolysis have been found to exhibit activity for oxygen reduction reaction (ORR) approaching that of Pt and electrochemical stability higher than previous MN 4 -containing macrocyclic molecular catalysts. Tremendous efforts have thus been devoted to the advancement of M–N–C catalysts as an economical alternative to Pt-based catalysts for proton exchange membrane fuel cell cathodes with a focus on simultaneously improving activity and stability. To this end, novel computational modeling techniques have been developed and applied to acquire knowledge crucial for accelerating the pace of M–N–C catalyst development. In this review, recent progress in computational method development, as well as the predictions of chemical structure of active sites, reaction pathways, ORR kinetics, and catalyst stability in electrochemical environments, are critically surveyed. Moreover, the crucial role of computational modeling to elucidate the functional mechanism of M–N–C catalysts for ORR in acid media and enable rational design of M–N–C catalysts is discussed with a visionary outlook for the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser-plasma interactions with a Fourier-Bessel particle-in-cell method

A new spectral particle-in-cell (PIC) method for plasma modeling is presented and discussed. In the proposed scheme, the Fourier-Bessel transform is used to translate the Maxwell equations to the quasi-cylindrical spectral domain. In this domain, the equations are solved analytically in time, and the spatial derivatives are approximated with high accuracy. In contrast to the finite-difference time domain (FDTD) methods, that are used commonly in PIC, the developed method does not produce numerical dispersion and does not involve grid staggering for the electric and magnetic fields. These features are especially valuable in modeling the wakefield acceleration of particles in plasmas. The proposed algorithm is implemented in the code PLARES-PIC, and the test simulations of laser plasma interactions are compared to the ones done with the quasi-cylindrical FDTD PIC code CALDER-CIRC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SIMULATED PERFORMANCE OF TIMESCALE METRICS FOR APERIODIC LIGHT CURVES

Aperiodic variability is a characteristic feature of young stars, massive stars, and active galactic nuclei. With the recent proliferation of time-domain surveys, it is increasingly essential to develop methods to quantify and analyze aperiodic variability. We develop three timescale metrics that have been little used in astronomy—Δm-Δt plots, peak-finding, and Gaussian process regression—and present simulations comparing their effectiveness across a range of aperiodic light curve shapes, characteristic timescales, observing cadences, and signal to noise ratios. We find that Gaussian process regression is easily confused by noise and by irregular sampling, even when the model being fit reflects the process underlying the light curve, but that Δm-Δt plots and peak-finding can coarsely characterize timescales across a broad region of parameter space. We make public the software we used for our simulations, both in the spirit of open research and to allow others to carry out analogous simulations for their own observing programs.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ effective pumping speed measurements as a tool for non-evaporable getter activation and saturation monitoring

We have developed method of in situ effective pumping speed measurements based on injecting finite gas pulse into a vacuum volume and subsequent recording of pressure response using a Residual Gas Analyzer (RGA). The pressure burst caused by injected gas pulse falls exponentially in time and the exponential coefficient of such pressure decay is proportional to total effective pumping speed of all vacuum pumps acting on vacuum chamber volume. The effective pumping speed can be extracted from the dependence of injected gas species pressure vs time recorded by an RGA. Non-Evaporable Getters (NEGs) are widely used in multiple ultra and extremely high vacuum devices and applications during the last several decades. Areas of NEG applications were recently expanded into vacuum devices with relatively high-pressure levels (up to 10 -7 Torr) by the invention of high capacity ZAO NEG which can be operated at elevated temperatures. The intrinsic property of all NEG-based vacuum pumps is the reduction of their pumping speed, called “NEG saturation”, after an extended period of operation. Typical time interval for such process can span from about a month and up to a few years depending on NEG type, vacuum level of NEG pump operation, and residual gas content. After that, the NEG pump will require a re-activation cycle to restore its pumping speed close to the initial value. For many applications it is difficult to realize what is the current pumping speed of NEG pump is and when the pump should be re-activated. A method for in situ effective pumping speed measurements developed in this study can be used as a tool for NEG-based pump activation and saturation monitoring. Application of such an approach to monitor pumping status of NEG pumps was utilized and will be continually used at Extended EBIS which was recently developed and commissioned for Relativistic Heavy Ion Collider (RHIC) and future Electron Ion Collider (EIC). The results obtained during commissioning are presented and discussed.

43 PARTICLE ACCELERATORS↗

Electron Density Determination, Bonding and Properties of Tetragonal Ferromagnetic Intermetallics

The project developed quantitative convergent-beam electron diffraction (QCBED) methods by energy-filtered transmission electron microscopy (EFTEM) and used them in combination with density functional theory (DFT) calculations to study the electron density distribution in metallic and intermetallic phases with different cubic and non-cubic crystal structures that comprise elements with d-electron shells. The experimental methods developed here focus on the bonding charge distribution as one of the quantum mechanical characteristics central for understanding of intrinsic properties and validation of DFT calculations. Multiple structure and temperature factors have been measured simultaneously from nano-scale volumes of high-quality crystal with sufficient accuracy and precision for comparison with electron density distribution calculations by DFT. The often anisotropic temperature factors for the different atoms and atom sites in chemically ordered phases can differ significantly from those known for relevant pure element crystals due to bonding effects. Thus they have been measured from the same crystal volumes from which the structure factors have been determined. The ferromagnetic ordered intermetallic phases FePd and FePt are selected as model systems for 3d-4d and 3d-5d electron interactions, while the intermetallic phases NiAl and TiAl are used to probe 3d-3p electron interactions. Additionally, pure transition metal elements with d-electrons have been studied. FCC metals exhibit well defined delocalized bonding charge in tetrahedral sites, while less directional, more distributed bonding charge attains in BCC metals. Agreement between DFT calculated and QCBED results degrades as d-electron levels fill in the elements, and for intermetallics as d-d interactions become prominent over p-d interactions. Utilizing the LDA+U approach enabled inclusion of onsite Coulomb-repulsion effects in DFT calculations, which can afford improved agreements with QCBED results. This implies that onsite Coulomb repulsion effects become non-negligible as the d-orbitals fill. The use of now easily measured low-order structure factors as an additional experimental metric in validation of DFT calculation of electronic structures of crystals offers potential to capture better both total energy related properties and details of the interatomic bonding in system with d-electron orbital contributions. This effort advanced the state of the art in quantitative TEM experimentation, provides original experimental data uniquely suited for new validation approaches of DFT calculations of d-electron affected transition metals and intermetallics.

36 MATERIALS SCIENCE↗

Representing DC-Coupled PV+Battery Hybrids in a Capacity Expansion Model

Recent technology cost and performance improvements and the federal investment tax credit (ITC) have driven growing interest in coupling solar photovoltaic (PV) and battery systems. Combining these technologies into co-located or hybridized PV+battery systems has the potential to lower costs and increase energy output relative to multiple independent systems. In this work, we provide an overview of PV+battery systems and demonstrate methods for incorporating them into NREL’s Regional Energy Deployment System (ReEDS) capacity expansion model. Although the methods are applied to a specific model, we anticipate that the approaches used here can be useful for informing PV+battery method development for other capacity expansion models. The implemented method relies heavily on the native representations of PV and battery technologies; therefore, the focus of this work is on capturing and parameterizing the interactions between them for a configuration in which the PV and battery technologies share a single bi-directional inverter. This work also demonstrates the impacts of including PV+battery systems in the ReEDS optimization for the conterminous United States through 2050. In particular, we perform parametric sensitivities for input assumptions that are uncertain and expected to influence PV+battery deployment levels, including (a) the cost of PV+battery systems relative to independent PV and battery systems, (b) the battery component’s qualification for the ITC, and (c) future cost trajectories for PV and battery systems. We find that PV+battery deployment could occur throughout the conterminous United States if there are cost savings associated with DC coupling PV and battery technologies. If even modest (5%) cost savings can be achieved (through a shared inverter and balance-of-system costs), then approximately one-third of utility-scale PV deployment through 2050 adopts the DC-coupled hybrid configuration, resulting in total PV+battery deployment that exceeds the magnitude of PV+battery projects in U.S. interconnection queues in 2020. If greater cost savings can be achieved through DC coupling (e.g., due to a growing amount of shared balance-of-system costs, reduced financial risk, or modularity) or more rapid cost and performance improvements are realized for PV and battery technologies, then total PV+battery deployment and the share of PV and battery deployment that adopts the hybrid configuration grows (to >50%). In all cases, growing PV+battery deployment primarily displaces independent PV and battery technologies, indicating the strong competition between the hybrid and independent configurations comprising technologies with similar performance characteristics.

14 SOLAR ENERGY↗

PACT Data Management Plan (V.1.0)

The Perovskite PV Accelerator for Commercial Technology (PACT) is an independent validation center for the evaluation of perovskite PV technologies and their bankability. The center is led by Sandia National Laboratories and the National Renewable Energy Laboratory (NREL) and includes as part of its team Los Alamos National Laboratory (LANL), CFV Labs, Black and Veatch (B&V), and the Electric Power Research Institute (EPRI). The goals of the center are to: Develop and improve indoor and outdoor performance characterization methods, Develop and validate accelerated qualification testing for early failures (5-10 years), Research degradation and failure modes, Validate outdoor performance, and Provide bankability services to US perovskite PV (PSC) industry. The importance of data and data management to the success and outcomes of the PACT center is paramount. This report describes how data will be managed and protected by PACT and identifies important data management principles that will guide our approach.

14 SOLAR ENERGY↗