Stress-rupture strength and microstructural stability of W-HF-C wire-reinforced superalloy composites
W-Hf-C superalloy composites were found to be potentially useful for turbine-blade applications on the basis of stress-rupture strength. The 100- and 1000-hour rupture strengths obtained for 70 volume percent fiber composites tested at 1090 C were 420 and 280 MN/sq m. The investigation indicated that with better quality fibers, composites having 100- and 1000-hour rupture strengths of 570 and 370 MN/sq m may be obtained. Metallographic studies indicated sufficient fiber-matrix compatibility for long-term applications at 1090 C for 1000 hours or more.