Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mix Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Enhanced Hydrothermal Stability and Catalytic Activity of LaxZryOz Mixed Oxides for the Ketonization of Acetic Acid in the Aqueous Condensed Phase

Common ketonization catalysts such as ZrO2, CeO2, and TiO2-based catalysts have been reported to lose surface area, undergo phase transformation, and lose catalytic activity when utilized in the condensed aqueous phase. In this work, we synthesized a series of LaxZryOz mixed-metal oxides with different La:Zr atomic ratios with the goal of enhancing the catalytic activity and stability for the ketonization of acetic acid in condensed aqueous media at 568 K. We synthesized a hydrothermally stable LaxZryOz mixed-metal oxide catalyst with ketonization activity360 and 40 times more active than La2O3 and ZrO2, respectively. Catalyst characterization techniques suggest that the enhanced stability of the LaxZryOz catalysts is observed with the formation of a phase isomorphic with tetragonal ZrO2. DRIFT spectroscopy measurements indicated the enhanced catalytic activity of LaxZryOz catalysts correlated with greater acetic acid surface population in the presence of H2O versus pure ZrO2.

ketonization, deoxygenation, carboxylic acid, acet↗

Treatment of fly ash for use in concrete

A process for treating fly ash to render it highly usable as a concrete additive. A quantity of fly ash is obtained that contains carbon and which is considered unusable fly ash for concrete based upon foam index testing. The fly ash is mixed with an activator solution sufficient to initiate a geopolymerization reaction and for a geopolymerized fly ash. The geopolymerized fly ash is granulated. The geopolymerized fly ash is considered usable fly ash for concrete according to foam index testing. The geopolymerized fly ash may have a foam index less than 35% of the foam index of the untreated fly ash, and in some cases less than 10% of the foam index of the untreated fly ash. The activator solution may contain an alkali metal hydroxide, carbonate, silicate, aluminate, or mixtures thereof.

36 MATERIALS SCIENCE↗

Treatment of fly ash for use in concrete

A process for treating fly ash to render it highly usable as a concrete additive. A quantity of fly ash is obtained that contains carbon and which is considered unusable fly ash for concrete based upon foam index testing. The fly ash is mixed with an activator solution sufficient to initiate a geopolymerization reaction and for a geopolymerized fly ash. The geopolymerized fly ash is granulated. The geopolymerized fly ash is considered usable fly ash for concrete according to foam index testing. The geopolymerized fly ash may have a foam index less than 35% of the foam index of the untreated fly ash, and in some cases less than 10% of the foam index of the untreated fly ash. The activator solution may contain an alkali metal hydroxide, carbonate, silicate, aluminate, or mixtures thereof.

36 MATERIALS SCIENCE↗

MEASUREMENT OF SPECIFIC HEAT CAPACITY OF SALTSTONE

One of the goals of the Saltstone variability study is to identify (and quantify the impact of) the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. The heat capacity of the Saltstone waste form is one of the important properties of Saltstone mixes that was last measured at SRNL in 1997. It is therefore important to develop a core competency for rapid and accurate analysis of the specific heat capacity of the Saltstone mixes in order to quantify the impact of compositional and operational variations on this property as part of the variability study. The heat capacity, coupled with the heat of hydration data obtained from isothermal calorimetry for a given Saltstone mix, can be used to predict the maximum temperature increase in the cells within the vaults of the Saltstone Disposal Facility (SDF). The temperature increase controls the processing rate and the pour schedule. The maximum temperature is also important to the performance properties of the Saltstone. For example, in mass pours of concrete or grout of which Saltstone is an example, the maximum temperature increase and the maximum temperature difference (between the surface and the hottest location) are controlled to ensure durability of the product and prevent or limit the cracking caused by the thermal gradients produced during curing. This report details the development and implementation of a method for the measurement of the heat capacities of Saltstone mixes as well as the heat capacities of the cementitious materials of the premix and the simulated salt solutions used to batch the mixes. The developed method utilizes the TAM Air isothermal calorimeter and takes advantage of the sophisticated heat flow measurement capabilities of the instrument. Standards and reference materials were identified and used to validate the procedure and ensure accuracy of testing. Heat capacities of Saltstone mixes were {approx} 55% higher than the previous measurement of specific heat capacity on a reference Saltstone mix in 1997. Values of mixes prepared using Deliquification, Dissolution and Adjustment (DDA), Modular Caustic Side Solvent Extraction Unit (MCU) and Salt Waste Processing Facility (SWPF) simulants and premix at 0.60 w/cm ratio were {approx} 1.95 J/g/{sup o}C and were equivalent within experimental error. The simple law of mixtures was used to predict the heat capacities of the Saltstone and the results were in excellent agreement with experimental data. This simple law of mixtures can therefore be used to predict the heat capacities of Saltstone mixes in those cases where measurements have not been made. The time dependence of the heat capacity is important as an input to the modeling of temperature increase in Saltstone vaults. The heat capacity of a mix of MCU and premix at 0.60 w/cm ratio was measured immediately after initial mixing and then periodically up to times greater than 100 days. Within experimental error, the heat capacity did not change with time. Therefore, the modeling is not complicated by requiring a time dependent function for specific heat capacity. The water to cementitious material (w/cm) ratio plays a key role in determining the value of the heat capacity. Both experimental and predictive values for SWPF mixes as function of the w/cm ratio were obtained and presented in this report. Predictions of the maximum temperatures of the Saltstone mixes were made using the heat of hydration data from previous isothermal measurements and the newly measured heat capacities for DDA, MCU and SWPF mixes. The maximum temperature increase ranged from 37 to 48 C for these mixes. The presence of aluminate at 0.33 M produced a temperature increase of 68 C which is close to the adiabatic temperature rise of 74 C observed by Steimke and Fowler in 1997 for a mix containing 0.35 M aluminate. Aluminum dissolution of the sludge will increase the aluminate in the DSS which in turn will result in a larger temperature increase in the Saltstone vaults during the curing period. The initial temperature of the Saltstone mixes in the Saltstone Production Facility (SPF) can be predicted using the specific heat capacities of Decontaminated Salt Solutions (DSS), the specific heat capacities of cementitious materials, and the initial temperatures of the DSS and the premix. This initial mix temperature is dominated by the DSS temperature due to its high heat capacity relative to the cementitious materials. Therefore, controlling the initial temperature of the DSS to lower temperatures will lead to lower maximum temperatures in the vault for a given batch of Saltstone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Technology Maturation Plan for Immobilization of High-Level Waste in Glass Ceramics

A technology maturation plan (TMP) was developed for immobilization of high-level waste (HLW) raffinate in a glass-ceramic waste form using a cold-crucible induction melter (CCIM). The TMP was prepared by the following process: 1) define the reference process and boundaries of the technology being matured, 2) evaluate the technology elements and identify the critical technology elements (CTE), 3) identify the technology readiness level (TRL) of each of the CTE’s using the DOE G 413.3-4, 4) describe the development and demonstration activities required to advance the TRLs to 4 and 6 in order, and 5) prepare a preliminary plan to conduct the development and demonstration. Results of the technology readiness assessment identified five CTE’s and found relatively low TRL’s for each of them: • Mixing, sampling, and analysis of waste slurry and melter feed: TRL-1; • Feeding, melting, and pouring: TRL-1; • Glass ceramic formulation: TRL-1; • Canister cooling and crystallization: TRL-1; and • Canister decontamination: TRL-4. Although the TRL’s are low for most of these CTE’s (TRL-1) primarily because the specific waste stream is not known or tested, the effort required to advance them to higher values is relatively low. A TRL of 2 would be obtained by completing an initial waste composition/property estimate, a preliminary engineering study, some additional laboratory scale tests of the glass-ceramic, and a mixing and sampling test. Relatively little additional effort is required to advance the technology to TRL-3.

Glass ceramics↗

Influence of fuel temperature on supersonic mixing and combustion of hydrogen

Results are presented from an experimental investigation of the influence of fuel stagnation temperature on the mixing and reaction of hydrogen injected transverse to a supersonic flow in a duct. The hydrogen fuel was injected stoichiometrically at stagnation temperatures of 300 K and 800 K from a row of five circular orifices in the duct wall. Detailed measurements in the flow at the duct exit are used to determine the overall amount of mixing accomplished at each of three test conditions. Static pressure distributions are used with duct wall temperatures and heat flux in a one-dimensional analysis to deduce the fraction of fuel reacted along the duct. Results from the one-dimensional analyses of the tests with hot fuel indicated slightly more fuel reacted at the exit; however, differences in the accomplished mixing obtained from integrations of exit surveys were small.

Rogers, R. C.↗

Study and development of an air conditioning system operating on a magnetic heat pump cycle (design and testing of flow directors)

This report describes the fabrication, design of flow director, fluid flow direction analysis and testing of flow director of a magnetic heat pump. The objectives of the project are: (1) to fabricate a demonstration magnetic heat pump prototype with flow directors installed; and (2) analysis and testing of flow director and to make sure working fluid loops flow through correct directions with minor mixing. The prototype was fabricated and tested at the Development Testing Laboratory of Kennedy Space Center. The magnetic heat pump uses rear earth metal plates rotate in and out of a magnetic field in a clear plastic housing with water flowing through the rotor plates to provide temperature lift. Obtaining the proper water flow direction has been a problem. Flow directors were installed as flow barriers between separating point of two parallel loops. Function of flow directors were proven to be excellent both analytically and experimentally.

Wang, Pao-Lien↗

Low-speed performance of an axisymmetric, mixed-compression, supersonic inlet with auxiliary inlets

A test program was conducted to determine the aerodynamic performance and acoustic characteristics associated with the low-speed operation of a supersonic, axisymmetric, mixed-compression inlet with auxiliary inlets. Blow-in-auxiliary doors were installed on the NASA Ames P inlet. One door per quadrant was located on the cowl in the subsonic diffuser selection of the inlet. Auxiliary inlets with areas of 20 and 40 percent of the inlet capture area were tested statically and at free-stream Mach numbers of 0.1 and 0.2. The effects of boundary layer bleed inflow were investigated. A JT8D fan simulator driven by compressed air was used to pump inlet flow and to provide a characteristic noise signature. Baseline data were obtained at static free-stream conditions with the sharp P-inlet cowl lip replaced by a blunt lip. Auxiliary inlets increased overall total pressure recovery of the order of 10 percent.

Trefny, C. J.↗

CONVECTIVE OVERSHOOT MIXING IN MODELS OF THE STELLAR INTERIOR

Convective overshoot mixing plays an important role in stellar structure and evolution. However, overshoot mixing is also a long-standing problem; it is one of the most uncertain factors in stellar physics. As is well known, convective overshoot mixing is determined by the radial turbulent flux of the chemical component. In this paper, a local model of the radial turbulent flux of the chemical component is established based on hydrodynamic equations and some model assumptions and is tested in stellar models. The main conclusions are as follows. (1) The local model shows that convective overshoot mixing could be regarded as a diffusion process and the diffusion coefficient for different chemical elements is the same. However, if the non-local terms i.e., the gradient of the third-order moments, are taken into account, the diffusion coefficient for each chemical element should in general be different. (2) The diffusion coefficient of convective/overshoot mixing shows different behaviors in the convection zone and in the overshoot region because the characteristic length scale of the mixing is large in the convection zone and small in the overshoot region. Overshoot mixing should be regarded as a weak mixing process. (3) The diffusion coefficient of mixing is tested in stellar models, and it is found that a single choice of our central mixing parameter leads to consistent results for a solar convective envelope model as well as for core convection models of stars with masses from 2 M to 10 M.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of B$0\atop{s}$ Mixing at the D-Zero Detector at Fermilab Using the Semi-leptonic Decay B$0\atop{s}$ → D$-\atop{s}$ μ + v X

B$0\atop{s}$ mixing studies provide a precision test of Charge-Parity violation in the Standard Model. A measurement of Δm s constrains elements of the CKM quark rotation matrix [1], providing a probe of Standard Model Charge-Parity violation. This thesis describes a study of B$0\atop{s}$ mixing in the semileptonic decay B$0\atop{s}$ → D s - μ + vX, where D s - → Φπ - , using data collected at the D-Zero detector at Fermi National Accelerator in Batavia, Illinois. Approximately 2.8 fb -1 of data collected between April 2002 and August 2007 was used, covering the entirety of the Tevatron's RunIIa (April 2002 to March 2006) and part of RunIIb (March 2006-August 2007). Taggers using both opposite-side and same-side information were used to obtain the flavor information of the B s 0 meson at production. The charge of the muon in the decay B$0\atop{s}$ → D s - μ + vX was used to determine the flavor of the B$0\atop{s}$ at decay. The B$d\atop{0}$ mixing frequency, Δm d , was measured to verify the analysis procedure. A log-likelihood calculation was performed, and a measurement of Δm s was obtained. The final result was Δm s = 18.86 ± 0.80(stat.) ± 0.37(sys.) with a significance of 2.6σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A field study of solid rocket exhaust impacts on the near-field environment

Large solid rocket motors release large quantities of hydrogen chloride and aluminum oxide exhaust during launch and testing. Measurements and analysis of the interaction of this material with the deluge water spray and other environmental factors in the near field (within 1 km of the launch or test site) are summarized. Measurements of mixed solid and liquid deposition (typically 2 normal HCl) following space shuttle launches and 6.4 percent scale model tests are described. Hydrogen chloride gas concentrations measured in the hours after the launch of STS 41D and STS 51A are reported. Concentrations of 9 ppm, which are above the 5 ppm exposure limits for workers, were detected an hour after STS 51A. A simplified model which explains the primary features of the gas concentration profiles is included.

Anderson, B. J.↗

Plasma tests of sprayed coatings for rocket thrust chambers

Several plasma-sprayed coating systems were evaluated for structural stability in hydrogen plasma and in oxygen plasma mixed with hydrogen plasma. The principal test heat flux was 15 Btu per inch squared seconds. The system consisted of a number of thin 0.002 to 0.020 in. layers of metal oxides and/or metals. The principal materials included are molybdenum nichrome, alumina, and zirconia. The study identifies important factors in coating system fabrication and describes the durability of the coating systems in the test environments. Values of effective thermal conductivity for some of the systems are indicated.

Curren, A. N.↗

Multi-component Reynolds-averaged Navier–Stokes simulations of Richtmyer–Meshkov instability and mixing induced by reshock at different times

Turbulent mixing generated by shock-driven acceleration of a perturbed interface is simulated using a new multi-component Reynolds-averaged Navier–Stokes (RANS) model closed with a two-equation K–ϵ model. Here, the model is implemented in a hydrodynamics code using a third-order weighted essentially non-oscillatory finite-difference method for the advection terms and a second-order central difference method for the gradients in the source and diffusion terms. In the present reshocked Richtmyer–Meshkov instability and mixing study, an incident shock with Mach number Ma s = 1.20 is generated in air and progresses into a sulfur hexafluoride test section. The time evolution of the predicted mixing layer widths corresponding to six shock tube test section lengths are compared with experimental measurements and three-dimensional multi-mode numerical simulations. The mixing layer widths are also compared with the analytical self-similar power-law solution of the simplified model equations prior to reshock. A set of model coefficients and initial conditions specific to these six experiments is established, for which the widths before and after reshock agree very well with experimental and numerical simulation data. A second set of general coefficients that accommodates a broader range of incident shock Mach numbers, Atwood numbers, and test section lengths is also established by incorporating additional experimental data for Ma s = 1.24, 1.50, and 1.98 with At = 0.67 and Ma s = 1.45 with At = –0.67 and previous RANS modeling. Terms in the budgets of the turbulent kinetic energy and dissipation rate equations are examined to evaluate the relative importance of turbulence production, dissipation and diffusion mechanisms during mixing. Convergence results for the mixing layer widths, mean fields, and turbulent fields under grid refinement are presented for each of the Ma s = 1.20 cases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Swirling base injection for supersonic combustion ramjets.

Experimental evaluation of the swirling base injection proposed by Swithenbank and Chigier (1969) for application in supersonic combustion ramjets or scramjets. This concept of accelerated mixing in supersonic streams through swirl was tested, but the results indicate that swirl does not produce any enhancement of mixing.

Povinelli, L. A.↗

Effects of Initial Conditions on a Single Jet in Crossflow

An experimental investigation of the effects of jet inlet flow conditions has been conducted for the isothermal mixing of a single jet injected into a crossflow. Jet penetration and mixing was studied using planar Mie scattering to measure time-averaged jet mixture fraction distributions. The effects of 'passive' control methods such as jet 'tabs' and jet swirl are reported. Mixing effectiveness, determined using a spatial unmixedness parameter based on the variance of the mean jet concentration distributions, was compared to a baseline case of a round jet injected into a uniform crossflow. All results are compared at a jet-to-mainstream momentum-flux ratio of 8.5. In the near-field, the mixing rates are similar to, or less than, the baseline configuration using this measure of mixedness. None of the tested configurations appear to significantly augment mixing within a downstream distance of 3 diameters of an equivalent-area round orifice.

Liscinsky, D. S.↗

ESTIMATING HIGH LEVEL WASTE MIXING PERFORMANCE IN HANFORD DOUBLE SHELL TANKS

The ability to effectively mix, sample, certify, and deliver consistent batches of high level waste (HLW) feed from the Hanford double shell tanks (DSTs) to the Waste Treatment and Immobilization Plant (WTP) presents a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. The Department of Energy's (DOE's) Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS) is currently demonstrating mixing, sampling, and batch transfer performance in two different sizes of small-scale DSTs. The results of these demonstrations will be used to estimate full-scale DST mixing performance and provide the key input to a programmatic decision on the need to build a dedicated feed certification facility. This paper discusses the results from initial mixing demonstration activities and presents data evaluation techniques that allow insight into the performance relationships of the two small tanks. The next steps, sampling and batch transfers, of the small scale demonstration activities are introduced. A discussion of the integration of results from the mixing, sampling, and batch transfer tests to allow estimating full-scale DST performance is presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulations of Multi-Mode Combustion Regimes Realizable In a Gasoline Direct Injection Engine

Lean and dilute gasoline compression ignition (GCI) operation in spark ignition (SI) engines are an attractive strategy to attain high fuel efficiency and low NOx levels. However, this combustion mode is often limited to low-load engine conditions due to the challenges associated with autoignition controllability. In order to overcome this constrain, multi-mode (MM) operating strategies, consisting of advanced compression ignition (ACI) at low load and conventional SI at high load, have been proposed. In this three-dimensional computational fluid dynamics study, the concept of multi-mode combustion using two RON98 gasoline fuel blends (Co-Optima Alkylate and E30) in a gasoline direct injection (GDI) engine were explored. To this end, a new reduced mechanism for simulating the kinetics of E30 fuel blend is introduced in this study. To cover the varying engine load demands for multi-mode engines, primary combustion dynamics observed in ACI and SI combustion modes was characterized and validated against experimental measurements. In order to implement part-load conditions, a strategy of mode transition between SI and ACI combustion (i.e., mixed-mode combustion) was then explored numerically by creating a virtual test condition. The results obtained from the mixed-mode simulations highlight an important feature that deflagrative flame propagation regime coexists with ignition-assisted end-gas autoignition. This study also identifies a role of turbulent flow property adjacent to premixed flame front in characterizing the mixed-mode combustion. The employed hybrid combustion model was verified to perform simulations aiming at suitable range of multi-mode engine operations.

Kim, Sayop↗