Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

60 APPLIED LIFE SCIENCES↗

Estimating ionization states and continuum lowering from ab initio path integral Monte Carlo simulations for warm dense hydrogen

Warm dense matter (WDM) is an active field of research, with applications ranging from astrophysics to inertial confinement fusion. Ionization degree and continuum lowering are important quantities to understand how materials behave under these conditions, but can be difficult to diagnose since experimental campaigns are limited and often require model-dependent analysis. This is especially true for hydrogen, which has a comparably low scattering cross section, making high-quality data particularly difficult to obtain. Consequently, building equation of state tables often relies on simulations in combination with untested approximations to extract properties from experiments. Here, we investigate an approach for extracting the ionization potential depression and ionization degree—quantities which are otherwise not directly accessible from the physical model—from first-principles path integral Monte Carlo (PIMC) simulations utilizing a chemical model. In contrast to experimental measurements, where noise and nonequilibrium effects add to the uncertainty of the inferred parameters, PIMC simulations provide a clean signal with well-defined thermodynamic conditions. Comparisons against commonly used models show a qualitative agreement, but we find deviations primarily for the high-density and high-temperature cases. We also demonstrate the decreasing sensitivity of the dynamic structure factor with respect to both ionization and continuum lowering for increasing scattering angles in x-ray Thomson scattering experiments. Our work has important implications for the design of future experiments, but also offers qualitative understanding of structure factors and the imaginary-time correlation function obtained from first-principles quantum Monte Carlo simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-290: Secondary Dose Monitoring Using Scintillating Fibers in Proton Therapy of Prostate Cancer: A Geant4 Monte Carlo Simulation

Purpose: To monitor the secondary dose distribution originating from a water phantom during proton therapy of prostate cancer using scintillating fibers. Methods: The Geant4 Monte Carlo toolkit version 9.6.p02 was used to simulate prostate cancer proton therapy based treatments. Two cases were studied. In the first case, 8 × 8 = 64 equally spaced fibers inside three 4 × 4 × 2.54 cmm{sup 3} DuPont™ Delrin blocks were used to monitor the emission of secondary particles in the transverse (left and right) and distal regions relative to the beam direction. In the second case, a scintillating block with a thickness of 2.54 cm and equal vertical and longitudinal dimensions as the water phantom was used. Geometrical cuts were used to extract the energy deposited in each fiber and the scintillating block. Results: The transverse dose distributions from secondary particles in both cases agree within <5% and with a very good symmetry. The energy deposited not only gradually increases as one moves from the peripheral row fibers towards the center of the block (aligned with the center of the prostate) but also decreases as one goes from the frontal to distal region of the block. The ratio of the doses from the prostate to the ones in the middle two rows of fibers showed a linear relationship with a slope (−3.55±2.26) × 10−5 MeV per treatment Gy. The distal detectors recorded a very small energy deposited due to water attenuation. Conclusion: With a good calibration and the ability to define a good correlation between the dose to the external fibers and the prostate, such fibers can be used for real time dose verification to the target.

60 APPLIED LIFE SCIENCES↗

Sensor Distortion Effects in Photon Monte Carlo Simulations

We present a detailed method to simulating sensor distortions using a photon and electron Monte Carlo method. We use three-dimensional electrostatic simulations to parameterize the perturbed electric field profile for nonideal sensor details. We follow the conversion of simulated photons, and the subsequent response of the converted electrons to the electric field pattern. These nonideal sensor details can be implemented efficiently in a Monte Carlo approach. We demonstrate that the nonideal sensor distortions have a variety of observable consequence including the modification of the astrometric pattern; the distortion of the electron diffusion size and shape; and the distortion of flats. We show analytic validation of the diffusion physics, reproduce two kinds of edge distortion, and show qualitative validation of field-free regions, lithography errors, and fringing. We also demonstrate that there are two related effects of doping variation having different observable consequences. We show that field distortions from accumulated electrons lead to intensity-dependent point-spread functions and the sublinear variance in flats. The method is implemented in the Photon Simulator and the code is publicly available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrostatics on the sphere with applications to Monte Carlo simulations of two dimensional polar fluids

We present two methods for solving the electrostatics of point charges and multipoles on the surface of a sphere, i.e., in the space S{sub 2}, with applications to numerical simulations of two-dimensional (2D) polar fluids. In the first approach, point charges are associated with uniform neutralizing backgrounds to form neutral pseudo-charges, while in the second, one instead considers bi-charges, i.e., dumbells of antipodal point charges of opposite signs. We establish the expressions of the electric potentials of pseudo- and bi-charges as isotropic solutions of the Laplace-Beltrami equation in S{sub 2}. A multipolar expansion of pseudo- and bi-charge potentials leads to the electric potentials of mono- and bi-multipoles, respectively. These potentials constitute non-isotropic solutions of the Laplace-Beltrami equation, the general solution of which in spherical coordinates is recast under a new appealing form. We then focus on the case of mono- and bi-dipoles and build the theory of dielectric media in S{sub 2}. We notably obtain the expression of the static dielectric constant of a uniform isotropic polar fluid living in S{sub 2} in terms of the polarization fluctuations of subdomains of S{sub 2}. We also derive the long range behavior of the equilibrium pair correlation function under the assumption that it is governed by macroscopic electrostatics. These theoretical developments find their application in Monte Carlo simulations of the 2D fluid of dipolar hard spheres. Some preliminary numerical experiments are discussed with a special emphasis on finite size effects, a careful study of the thermodynamic limit, and a check of the theoretical predictions for the asymptotic behavior of the pair correlation function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Semi-grand canonical Monte Carlo simulation of the acrolein induced surface segregation and aggregation of AgPd with machine learning surrogate models

The single atom alloy of AgPd has been found to be a promising catalyst for the selective hydrogenation of acrolein. It is also known that the formation of Pd islands on the surface will greatly reduce the selectivity of the reaction. As a result, the surface segregation and aggregation of Pd on the AgPd surface under reaction conditions of selective hydrogenation of acrolein are of great interest. In this work, we lay out a workflow that can predict the surface segregation and aggregation of Pd on a FCC(111) AgPd surface with and without the presence of acrolein. We use machine learning surrogate models to predict the AgPd bulk energy, AgPd slab energy, and acrolein adsorption energy on AgPd slabs. Then, we use the semi-grand canonical Monte Carlo simulation to predict the surface segregation and aggregation under different bulk Pd concentrations. Under vacuum conditions, our method predicts that only trace amount of Pd will exist on the surface at Pd bulk concentrations less than 20%. However, with the presence of acrolein, Pd will start to aggregate as dimers on the surface at Pd bulk concentrations as low as 6.5%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MONTE CARLO SIMULATIONS OF GLOBULAR CLUSTER EVOLUTION. VI. THE INFLUENCE OF AN INTERMEDIATE-MASS BLACK HOLE

We present results from a series of Monte Carlo (MC) simulations investigating the imprint of a central intermediate-mass black hole (IMBH) on the structure of a globular cluster. We investigate the three-dimensional and projected density profiles, and stellar disruption rates for idealized as well as realistic cluster models, taking into account a stellar mass spectrum and stellar evolution, and allowing for a larger, more realistic number of stars than was previously possible with direct N-body methods. We compare our results to other N-body and Fokker-Planck simulations published previously. We find, in general, very good agreement for the overall cluster structure and dynamical evolution between direct N-body simulations and our MC simulations. Significant differences exist in the number of stars that are tidally disrupted by the IMBH, and this is most likely caused by the wandering motion of the IMBH, not included in the MC scheme. These differences, however, are negligible for the final IMBH masses in realistic cluster models, as the disruption rates are generally much lower than for single-mass clusters. As a direct comparison to observations we construct a detailed model for the cluster NGC 5694, which is known to possess a central surface brightness cusp consistent with the presence of an IMBH. We find that not only the inner slope but also the outer part of the surface brightness profile agree well with observations. However, there is only a slight preference for models harboring an IMBH compared to models without.

79 ASTRONOMY AND ASTROPHYSICS↗

Shock interference prediction using direct simulation Monte Carlo

The shock interaction produced when an incident shock impinges on an inlet cowl lip is investigated for a cowl lip radius of 0.1 in. and flight conditions of Mach 15 and 35-km altitude. This problem is of interest in the design of hypersonic flight vehicles because the interference heating at the cowl lip surface from such a shock interaction is expected to be very high and the design of adequate thermal protection in this region will be challenging. Noncontinuum effects may be significant at this combination of altitude and small dimensions. If this is so, a computational solution based on the Navier-Stokes equations could significantly overpredict the surface heating on the cowl lip. Therefore, a kinetic theory solution technique, direct simulation Monte Carlo (DSMC), is used to predict the flowfield and surface heating. The details of modeling this problem and some preliminary results are presented. The same qualitative flow patterns are seen with DSMC and a continuum solution of the shock interference case, but the peak heating predicted with DSMC is somewhat lower.

Carlson, Ann B.↗

Monte-Carlo Simulation of Radiation Track Structure and Calculation of Dose Deposition in Nanovolumes

INTRODUCTION: The radiation track structure is of crucial importance to understand radiation damage to molecules and subsequent biological effects. Of a particular importance in radiobiology is the induction of double-strand breaks (DSBs) by ionizing radiation, which are caused by clusters of lesions in DNA, and oxidative damage to cellular constituents leading to aberrant signaling cascades. DSB can be visualized within cell nuclei with gamma-H2AX experiments. MATERIAL AND METHODS: In DSB induction models, the DSB probability is usually calculated by the local dose obtained from a radial dose profile of HZE tracks. In this work, the local dose imparted by HZE ions is calculated directly from the 3D Monte-Carlo simulation code RITRACKS. A cubic volume of 5 micron edge (Figure 1) is irradiated by a (Fe26+)-56 ion of 1 GeV/amu (LET approx.150 keV/micron) and by a fluence of 450 H+ ions, 300 MeV/amu (LET approx. 0.3 keV/micron). In both cases, the dose deposited in the volume is approx.1 Gy. The dose is then calculated into each 3D pixels (voxels) of 20 nm edge and visualized in 3D. RESULTS AND DISCUSSION: The dose is deposited uniformly in the volume by the H+ ions. The voxels which receive a high dose (orange) corresponds to electron track ends. The dose is deposited differently by the 56Fe26+ ion. Very high dose (red) is deposited in voxels with direct ion traversal. Voxels with electron track ends (orange) are also found distributed around the path of the track. In both cases, the appearance of the dose distribution looks very similar to DSBs seen in gammaH2AX experiments, particularly when the visualization threshold is applied. CONCLUSION: The refinement of the dose calculation to the nanometer scale has revealed important differences in the energy deposition between high- and low-LET ions. Voxels of very high dose are only found in the path of high-LET ions. Interestingly, experiments have shown that DSB induced by high-LET radiation are more difficult to repair. Therefore, this new approach may be useful to understand the nature of DSB and oxidative damage induced by ionizing radiation.

Plante, I.↗

Computational Study of a Cryopump Design for Fusion Exhaust Gas Purification Using Direct Simulation Monte Carlo

Cryopump-based direct internal recycling (DIR) of fusion fuel is an attractive prospect because it provides pumping of helium ash from a reactor along with separation of helium and other impurities from the fuel. Previous studies have demonstrated a continuously regenerating cryopump, referred to as the Snail pump, that separates helium ash from fusion fuel for reactor-relevant flow rates. Here, in this study, a conceptual cryopump was designed as a proof-of-principle study to target other impurities, besides helium ash, from the fusion exhaust that would complement the Snail pump. The impurity-removal cryopump consists of four sets of chevron fins, two sets operating at 80 K and the other two at 30 K. A computational study using direct simulation Monte Carlo (DSMC) was performed with a gas mixture of 96.5% D2, 2.0% He, and 0.5% each of CO2, N2, and CH4. In this configuration, 80 K chevron fin sets are capable of capturing CO2 and 30 K sets capable of capturing CO2, N2, and CH4. The computational study showed that the cryopump is capable of reducing the impurity content by more than two orders of magnitude from the flow.

Adhikari, Nirajan [Oak Ridge National Laboratory (↗

Thermodynamic Modeling of Complex Solid Solutions in the Lu-H-N System via Graph Neural Network Accelerated Monte Carlo Simulations

Metal hydrides are important across diverse applications, such as hydrogen storage, batteries, gas sensors, nuclear reactions, and high-temperature superconductivity. Previous computational studies of metal hydrides under extreme pressures, e.g., 𝑂⁡(10 2 ) ⁢GPa, usually treat them as stoichiometric compounds without considering interstitial lattice disorder. As pressures become more moderate in the 𝑂⁡(10 0 ) ⁢GPa and below range, hydrogen disorder at interstitial lattice sites becomes prominent, e.g., in the N-doped Lu hydride that was recently claimed superconducting near 1 GPa. Further adding compositional complexity from alloying and/or multielement interstitial occupation makes elucidating pressure- and temperature-dependent observables intractable by first-principles calculations alone. We therefore propose a lattice graph neural-network surrogate modeling approach to predict configuration- and pressure-dependent equation-of-state properties. Their efficiency permits Monte Carlo simulations to calculate Gibbs energies and pressure-dependent phase diagrams, thereby revealing insights into the synthesis conditions required for achieving desired phase equilibria. We demonstrate this concept for the compositionally complex cubic Lu(H,N,Va) 3 system where three constituents (hydrogen, nitrogen and vacancy) have disordered multielement interstitial occupancies and insights into pressure-dependent phase equilibria are critically needed, e.g., N-doping levels can significantly lower dehydrogenation temperatures and provide a new strategy to optimize hydrogen-storage alloys. This work can improve the thermodynamic understanding of the Lu-H-N system and help rational synthesis of N-doped Lu hydrides, but more generally demonstrates an efficient approach to model pressure-dependent thermodynamics of multicomponent solid solutions.

Monte Carlo methods↗

Monte Carlo simulations for understanding the transport properties of metallic nanowires

We report the conductance calculation of metallic nanowires of different metals under the application of a tensile force. The elongation induced by the tensile force was simulated by means of the canonical Monte Carlo method combined with the embedded atom method to compute the energy of the system. We studied nanowires composed of Ag, Au, Pt and Cu. The conductance was calculated by means of the Landauer formula and the non-equilibrium Green function formalism. As previously verified experimentally and using other simulation techniques, the conductance is quantized. In addition to this, we have found that there is a strong correlation between the magnitude of the conductance and the width of the nanowire at its thinnest point. Conductance histograms were analyzed for all the different metals.

36 MATERIALS SCIENCE↗

Classical trajectory Monte Carlo simulation of plasma fueling using magnetic plasma expulsion

The possibility of fueling a magnetically confined plasma using particle sources located inside of the plasma is studied by computer simulation. Magnetic plasma expulsion [R. E. Phillips and C. A. Ordonez, Phys. Plasmas 25, 012508 (2018)] would serve to keep the magnetically confined plasma away from the particle sources without adversely affecting plasma confinement. The simulations show how charged particles can be injected into a plasma by using particle sources located directly between two current-carrying wires that create a magnetic expulsion field. Plasma fueling with the average energy of injected particles greater than the average energy of plasma particles may serve for heating the plasma. Also, plasma fueling with positive and negative particles injected at different rates may serve for changing the neutrality of the plasma. Conditions for plasma fueling are investigated using a classical trajectory Monte Carlo simulation. Two types of particle sources are considered, and the fraction of emitted particles that reach (and fuel) the magnetically confined plasma is evaluated for each.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Grand Canonical Monte Carlo simulation program for computing ion distributions around biomolecules in hard sphere solvents

The GIBS software program is a Grand Canonical Monte Carlo (GCMC) simulation program (written in C++) that can be used for 1) computing the excess chemical potential of ions and the mean activity coefficients of salts in homogeneous electrolyte solutions; and, 2) for computing the distribution of ions around fixed macromolecules such as, nucleic acids and proteins. The solvent can be represented as neutral hard spheres or as a dielectric continuum. The ions are represented as charged hard spheres that can interact via Coulomb, hard-sphere, or Lennard-Jones potentials. In addition to hard-sphere repulsions, the ions can also be made to interact with the solvent hard spheres via short-ranged attractive square-well potentials.

Source record↗

A Grand Canonical Monte Carlo simulation program for computing ion distributions around biomolecules in hard sphere solvents

The GIBS software program is a Grand Canonical Monte Carlo (GCMC) simulation program (written in C++) that can be used for 1) computing the excess chemical potential of ions and the mean activity coefficients of salts in homogeneous electrolyte solutions; and, 2) for computing the distribution of ions around fixed macromolecules such as, nucleic acids and proteins. The solvent can be represented as neutral hard spheres or as a dielectric continuum. The ions are represented as charged hard spheres that can interact via Coulomb, hard-sphere, or Lennard-Jones potentials. In addition to hard-sphere repulsions, the ions can also be made to interact with the solvent hard spheres via short-ranged attractive square-well potentials.

Source record↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Billion-atom synchronous parallel kinetic Monte Carlo simulations of critical 3D Ising systems

An extension of the synchronous parallel kinetic Monte Carlo (spkMC) algorithm developed by Martinez et al. [J. Comp. Phys. 227 (2008) 3804] to discrete lattices is presented. The method solves the master equation synchronously by recourse to null events that keep all processors' time clocks current in a global sense. Boundary conflicts are resolved by adopting a chessboard decomposition into non-interacting sublattices. We find that the bias introduced by the spatial correlations attendant to the sublattice decomposition is within the standard deviation of serial calculations, which confirms the statistical validity of our algorithm. We have analyzed the parallel efficiency of spkMC and find that it scales consistently with problem size and sublattice partition. We apply the method to the calculation of scale-dependent critical exponents in billion-atom 3D Ising systems, with very good agreement with state-of-the-art multispin simulations.

97 MATHEMATICS AND COMPUTING↗

Dosimetric characterization and organ dose assessment in digital breast tomosynthesis: Measurements and Monte Carlo simulations using voxel phantoms

Purpose: Due to its capability to more accurately detect deep lesions inside the breast by removing the effect of overlying anatomy, digital breast tomosynthesis (DBT) has the potential to replace the standard mammography technique in clinical screening exams. However, the European Guidelines for DBT dosimetry are still a work in progress and there are little data available on organ doses other than to the breast. It is, therefore, of great importance to assess the dosimetric performance of DBT with respect to the one obtained with standard digital mammography (DM) systems. The aim of this work is twofold: (i) to study the dosimetric properties of a combined DBT/DM system (MAMMOMAT Inspiration Siemens{sup ®}) for a tungsten/rhodium (W/Rh) anode/filter combination and (ii) to evaluate organs doses during a DBT examination. Methods: For the first task, measurements were performed in manual and automatic exposure control (AEC) modes, using two homogeneous breast phantoms: a PMMA slab phantom and a 4 cm thick breast-shaped rigid phantom, with 50% of glandular tissue in its composition. Monte Carlo (MC) simulations were performed using Monte Carlo N-Particle eXtended v.2.7.0. A MC model was implemented to mimic DM and DBT acquisitions for a wide range of x-ray spectra (24 –34 kV). This was used to calculate mean glandular dose (MGD) and to compute series of backscatter factors (BSFs) that could be inserted into the DBT dosimetric formalism proposed by Dance et al. Regarding the second aim of the study, the implemented MC model of the clinical equipment, together with a female voxel phantom (“Laura”), was used to calculate organ doses considering a typical DBT acquisition. Results were compared with a standard two-view mammography craniocaudal (CC) acquisition. Results: Considering the AEC mode, the acquisition of a single CC view results in a MGD ranging from 0.53 ± 0.07 mGy to 2.41 ± 0.31 mGy in DM mode and from 0.77 ± 0.11 mGy to 2.28 ± 0.32 mGy in DBT mode. Regarding the BSF, the results achieved may lead to a MGD correction of about 6%, contributing to the improvement of the current guidelines used in these applications. Finally, considering the MC results obtained for the organ dose study, the radiation doses found for the tissues of the body other than the breast were in the range of tens of μSv, and are in part comparable to the ones obtained in standard DM. Nevertheless, in a single DBT examination, some organs (such as lung and thyroid) receive higher doses (of about 9% and 21%, respectively) with respect to the CC DM acquisition. Conclusions: Taking into account an average breast with a thickness of 4.5 cm, the MGDs for DM and DBT acquisitions were below the achievable value (2.0 mGy) defined by the European protocol. Additionally, in the case of a fusion imaging study (DM + DBT), the MGD for a 4.5 cm thick breast is of the order of 1.88 ± 0.36 mGy. Finally, organ dose evaluations underline the need to improve awareness concerning dose estimation of DBT exams for some organs, especially when radiation risk is assessed by using the effective dose.

60 APPLIED LIFE SCIENCES↗