Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of the adequacy of using few-group lattice-homogenized properties for the diffusion analysis of the super critical water reactor

Two issues may affect the accuracy of computed core reactivities and flux/power distributions for the Super Critical Water Reactor (SCWR) core with traditional core-analysis code RFSP: one is the two-energy-group neutron-diffusion theory; the other is the generation of lattice-homogenized properties with the lattice code based on the single-lattice-cell model without considering the effects of the environment. These two issues are not SCWR specific; however their effect may be more significant for SCWR. It has been illustrated that the lattice-homogenized properties calculated with the single-lattice-cell model is not sufficiently accurate for heterogeneous core configurations such as ACR-1000 checkerboard-voiding and core-reflector interface when adjacent channels experience significant spectrum interaction. To evaluate the adequacy of using two-group neutron-diffusion theory with single-lattice-based lattice properties for the analysis of the SCWR core, a 2-D SCWR benchmark problem was setup with the reference solution provided by the continuous-energy Monte-Carlo code SERPENT. The assessment shows that the traditional two-group neutron-diffusion theory with the single-lattice-cell- based lattice properties is not sufficient to capture either the spectral change or the environment effect for the SCWR core. The solution of the eight-group neutron-diffusion equation with the multicell- based lattice properties is considered appropriate for the analysis of the d SCWR core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-T-31: A Fast Finite Size Pencil Beam (FSPB) Convolution Algorithm for a New Co-60 Arc Therapy Machine

Purpose: Present a fast Finite Size Pencil Beam (FSPB) convolution algorithm for a new Co-60 arc therapy machine. The FSPB algorithm accounts for (i) strong angular divergence (short SAD), (ii) heterogeneity effect for primary attenuation, and (iii) source energy spectrum. Methods: The FSPB algorithm is based on a 0.5×0.5-cm2 dose kernel calculated using the GEPTS (Gamma Electron and Positron Transport System) Monte Carlo code. The dose kernel is tabulated using a thin XYZ mesh (0.1 mm steps in lateral directions) for radius less than 1 cm and using an RZ mesh (with varying steps) for larger radial distance. To account for SSD effect, 11 dose kernels with SSDs varying between 30 cm to 80 cm are calculated. Maynord factor and “lateral stretching” are applied to account for differences between closest and actual SSD. Appropriate rotations and second order interpolation are used to calculate the dose from a given beamlet to a point. Results: Accuracy: Dose distributions in water with 80 cm SSD are calculated using the new FSPB convolution algorithm and full Monte Carlo simulation (gold standard). Figs 1–4 show excellent agreements between FSPB and Monte Carlo calculations for different field sizes and at different depths. The dose distribution for a prostate case is calculated using FSPB (Fig.5). Sixty conformal beams with rectum blocking are assumed. Figs 6–8 show the comparison with Monte Carlo simulation based on the same beam apertures. The excellent agreement demonstrates the accuracy of the new algorithm in handling SSD variation, oblique incidence, and scatter contribution.Speed: The FSPB convolution algorithm calculates 28 million dose points per second using a single 2.2-GHz CPU. The present algorithm is seven times faster than a similar algorithm from Gu et al. (Phys. Med. Biol. 54, 2009, 6287–6297). Conclusion: A fast and accurate FSPB convolution algorithm was developed and benchmarked.

60 APPLIED LIFE SCIENCES↗

General purpose dynamic Monte Carlo with continuous energy for transient analysis

For safety assessments transient analysis is an important tool. It can predict maximum temperatures during regular reactor operation or during an accident scenario. Despite the fact that this kind of analysis is very important, the state of the art still uses rather crude methods, like diffusion theory and point-kinetics. For reference calculations it is preferable to use the Monte Carlo method. In this paper the dynamic Monte Carlo method is implemented in the general purpose Monte Carlo code Tripoli4. Also, the method is extended for use with continuous energy. The first results of Dynamic Tripoli demonstrate that this kind of calculation is indeed accurate and the results are achieved in a reasonable amount of time. With the method implemented in Tripoli it is now possible to do an exact transient calculation in arbitrary geometry. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantification of the ion and momentum fluxes toward the substrate during reactive magnetron sputtering

The ion and momentum fluxes toward the growing film during reactive magnetron sputtering of a Ti target in a mixture of Ar and N{sub 2} are determined. For the ion flux and ion energy distribution a retarding field energy analyzer has been employed. The results were confronted with planar and cylindrical probe measurements, two more common used techniques. For the momentum flux, energy resolved mass spectrometry and simulations with the binary collision Monte Carlo code SIMTRA were performed to determine the contribution to this flux by the impact of ions and sputtered and reflected particles. Based on the quantification of both fluxes, it can be concluded that there is a relation between the hardness and elastic modulus of the TiN films and the momentum flux.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation of cesium injection and distribution in rf-driven ion sources for negative hydrogen ion generation

Cesium seeded sources for surface generated negative hydrogen ions are major components of neutral beam injection systems in future large-scale fusion experiments such as ITER. Stability and delivered current density depend highly on the cesium conditions during plasma-on and plasma-off phases of the ion source. The Monte Carlo code CSFLOW3D was used to study the transport of neutral and ionic cesium in both phases. Homogeneous and intense flows were obtained from two cesium sources in the expansion region of the ion source and from a dispenser array, which is located 10 cm in front of the converter surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increasing the energy dynamic range of solid-state nuclear track detectors using multiple surfaces

Solid-state nuclear track detectors, such as CR-39, are widely used in physics and in many inertial confinement fusion (ICF) experiments. In the ICF experiments, the particles of interest, such as D{sup 3}He-protons, have ranges of order of the detector thickness. In this case, the dynamic range of the detector can be extended by recording data on both the front and back sides of the detector. Higher energy particles which are undetectable on the front surface can then be measured on the back of the detector. Studies of track formation under the conditions on the front and back of the detector reveal significant differences. Distinct front and back energy calibrations of CR-39 are therefore necessary and are presented for protons. Utilizing multiple surfaces with additional calibrations can extend the range of detectable energies on a single piece of CR-39 by up to 7-8 MeV. The track formation process is explored with a Monte Carlo code, which shows that the track formation difference between front and back is due to the non-uniform ion energy deposition in matter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multigroup Constant Calculation with Static α-Eigenvalue Monte Carlo for Time-Dependent Neutron Transport Simulations

Herein, multigroup constants for deterministic methods that preserve the time-dependent physics of the neutron transport equations are derived. Alternative multigroup constant weighting spectra are discussed: (1) the fundamental k-eigenfunction, (2) the fundamental α-eigenfunction, and (3) a composite of several α-modes. To generate the fundamental α-eigenfunction for calculating the multigroup constants, a static fundamental α-eigenvalue method is implemented into the open source Monte Carlo code OpenMC. Several static and kinetic problems are devised to verify the implementations and to investigate the relative performance of the alternative multigroup constant weighting spectra. Results emphasize that as a multigroup constant weighting spectrum, the fundamental α-eigenfunction offers physical characteristics that make it advantageous (in producing accurate solutions) over the typically used fundamental k-eigenfunction.

42 ENGINEERING↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of the Advanced D1S for Shutdown Dose Rate Calculations in Fusion Reactors

The assessment of the shutdown dose rate due to neutron activation is fundamental for shielding design, materials selection, licensing and planning of maintenance operations in high performances fusion devices. The shutdown dose rate calculations require the combined use of radiation transports and inventory codes. The typical approach consists in a two steps procedure. A pure neutron transport simulation is performed in a first step to calculate the spatial distribution of neutron spectra. The results are used as input for an activation calculation that provides the decay gamma source used in a second step for a pure gamma transport simulation (rigorous-two step, R2S). The Direct 1-Step (D1S) approach has been developed more than ten years ago by ENEA and the ITER team: this technique relies on a coupled neutron-decay gamma transport in a single simulation. It is based on the use of a modified version of the MCNP5 Monte Carlo code with specially tailored nuclear cross-section data for transport and FISPACT inventory code for temporal behaviour. The 'Advanced-D1S' is an improved version of D1S in which additional computational features have been introduced, such as the mesh tally capability and continuous time evolution assessment of the dose rate in single run dose. It has been validated through measurements at JET tokamak and comparison with R2S codes and a future benchmark experiment during next high performance deuterium-tritium campaign is in preparation at JET. It has also been extensively used for ITER calculations and recently applied to DEMO assessment. Present limitations and in progress code improvement strategy are described and discussed in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Analysis for a Criticality Benchmark [Slides]

This presentation discusses how KRUSTY was analyzed with LANL’s MCNP neutron transport code, Monte Carlo N-Particle. In the Monte Carlo method, neutrons are born in fission events and fly around the geometry having events (e.g., scatter, capture, fission, escape) according to the natural probabilities. “Natural probabilities” are given as neutron cross sections , which are measured and evaluated nuclear data. One of the goals of the benchmark project is to improve the nuclear cross sections (and the codes that use them). In this work, the response of interest is called k eff , which describes the neutron multiplication in a near critical system. Like most quantities, k eff is not measured directly; it is only inferred. In summation, MCNP results for k eff matched the measurements extremely well. The evaluated uncertainties are asymmetric and smaller than 0.00100 (e.g., + 0.00080 / – 0.00062). The largest uncertainties are due to alignment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Implementation of Windowed Multipole into MCNP6.3

This work details the implementation of the Windowed MultiPole(WMP) method of generating cross sections into the monte carlo code MCNP6.3, the verification and validation performed, and potential future improvements to be implemented. Further, this work contextualizes WMP within the broader changes to how nuclear data is stored, iterated upon, and used that have been developing over the past decade.

97 MATHEMATICS AND COMPUTING↗

FULL SIMULATION OF THE OPEN FIELD LINES ABOVE A PULSAR'S POLAR CAP. I. ACCELERATION

We have programmed a full simulation of the open field lines above the polar cap of a magnetized pulsar using a time-dependent, particle-in-cell (PIC) numerical code. We consider the case of free ejection of electrons from the star surface, a space charge limited flow (SCLF) model. We report here the first results of the simulation. Electrons are accelerating along the open field lines according to the flat spacetime SCLF Lorentz-factor prediction, with an oscillation pattern. Then, we add the General Relativistic (GR) frame-dragging correction that provides the particles the high Lorentz factor (10{sup 6}-10{sup 7}) needed to initiate pair production. The electrons accelerate according to the GR Lorentz-factor prediction, with an oscillation pattern. Electron-positron pair production is now being programmed using cross-sections from the literature and the Monte Carlo code. After completing this stage, we will automatically get (1) the positron return current (thus, we can calculate polar cap heating and X-ray emission), (2) the photons' and electrons' observed spectra (photons and electrons that escape the magnetosphere after the cascade), (3) the pulsar death line (pulsars without enough pair production), (4) the PFF height (pair formation front location), and (5) the multiplicity (number of pairs produced per primary particle). Those results will be reported in a different paper.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNPX, MONK, and ERANOS analyses of the YALINA booster subcritical assembly.

This paper compares the numerical results obtained from various nuclear codes and nuclear data libraries with the YALINA Booster subcritical assembly (Minsk, Belarus) experimental results. This subcritical assembly was constructed to study the physics and the operation of accelerator-driven subcritical systems (ADS) for transmuting the light water reactors (LWR) spent nuclear fuel. The YALINA Booster facility has been accurately modeled, with no material homogenization, by the Monte Carlo codes MCNPX (MCNP/MCB) and MONK. The MONK geometrical model matches that of MCNPX. The assembly has also been analyzed by the deterministic code ERANOS. In addition, the differences between the effective neutron multiplication factor and the source multiplication factors have been examined by alternative calculational methodologies. The analyses include the delayed neutron fraction, prompt neutron lifetime, generation time, neutron flux profiles, and spectra in various experimental channels. The accuracy of the numerical models has been enhanced by accounting for all material impurities and the actual density of the polyethylene material used in the assembly (the latter value was obtained by dividing the total weight of the polyethylene by its volume in the numerical model). There is good agreement between the results from MONK, MCNPX, and ERANOS. The ERANOS results show small differences relative to the other results because of material homogenization and the energy and angle discretizations.The MCNPX results match the experimental measurements of the {sup 3}He(n,p) reaction rates obtained with the californium neutron source.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The EURISOL Multi-MW Target Unit: Neutronics, Dose Rate, Shielding and Activation Calculations

The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims at designing a facility for producing high intensity radioactive ion beams, with unprecedented (two to three orders of magnitude higher) intensities, compared to the majority of the worldwide existing RIB facilities. For this purpose, a proton beam of energy 1 GeV and intensity up to 4 mA impinges on a liquid mercury target (the converter). The high neutron fluxes (in excess of 10{sup 15} n cm{sup -2} s{sup -1}) produced by spallation nuclear reactions in the converter induce fission on {sup 235}U targets surrounding the liquid mercury converter. In order to attain the intended high intensity radioactive ion beams, the appropriate configuration (geometry and materials) of the target unit components (converter, fission targets, moderators, reflectors) must be determined, to attain the highest possible fission rates in the uranium targets (in excess of 10{sup 15} fissions per second). The extremely high neutron and photon fluxes resulting from the operation of the target unit impose, for radiological protection and safety purposes, a careful assessment of the dose rates in the surrounding areas. Activation of the structural components must be studied. Thick shielding barriers must be designed. In this work, the so-called MAFF inspired target configuration, allowing a versatile operation, maintenance, remote control and storage of the fission targets is considered. The results obtained using the state-of-the-art Monte Carlo codes MCNPX and FLUKA are presented. The neutronics, dose rate, shielding and activation calculations, needed for radiological protection and safety assessment purposes are discussed.

43 PARTICLE ACCELERATORS↗

Validation of a Monte Carlo model for the MLC-Elekta Precise with MCNP6 - Paper 76

Cancer treatment using radiotherapy techniques needs an accurate prediction of the dose delivered to the patient at each position. Treatment planning systems (TPS) allow the optimization of the dose delivered to the tumor volume while minimizing the dose absorbed by the surrounding healthy tissue. Commercial treatment planning systems use empirical deterministic algorithms that do not correctly estimate the dose in the surroundings of heterogeneities. This lack of accuracy is taken into account as bigger security margins in the treatment, reducing the potential effect of the treatment. However, Monte Carlo (MC) simulation techniques have proved to predict the dose distribution more accurately and also representing experimental data better. Nevertheless, the clinical application of these techniques has been limited by the long calculation times they require. As high performance computers decrease in cost MC simulations become more feasible to be used in TPS. The present work improves a simplified model of the MLC-Elekta Precise linear accelerator (linac or unit from now on) previously developed and correctly validated by the group. A multileaf collimator (MLC) has been modelled according to the manufacturer specifications and added to the previous model to allow higher conformity in the studies. The full geometry has been entered to the MCNP6 Monte Carlo code to simulate the transport of particles through the linac. The geometry also includes a cubic water phantom for dosimetry studies and validation with experimental data. The experimental data employed for the dose distribution comparison has been measured at the linac from the linac Hospital Universitari Clinic de Valencia (Spain). Additionally, particles are stored in a phase space surface before their entrance in the water to be analyzed and for performance optimization. Given the results presented, we conclude that this first approach to validate a model of the Elekta Precise linac from the Hospital Cl nic Universitari de Valancia represents well the depth-dose distribution, but fails at representing the dose profiles. It has been shown that they predict too much penumbra, probably caused by the filtration between the leaves. In order to solve this problems, further work is needed to improve the simulated model. This work will mainly focus on the multileaf collimator. Also, the codes developed by the group to analyze phase space files produced by MCNP6 have proven highly useful. As work progress and the codes are debugged, they will be published so that the community can take advantage of them.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary design of control rods in the single-fluid double-zone thorium molten salt reactor (SD-TMSR)

Recent studies on Molten Salt Reactors (MSRs) showed that the excess reactivity at the beginning of the operation is large for many fueling strategies and must be compensated by a reactivity control system. The current work introduces a reliable safety system based on control rods in addition to the online feed system reactivity control in the Single-fluid Double-zone Thorium-based Molten Salt Reactor (SD-TMSR). Three different initial fissile loadings are considered: 233 U, reactor-grade Pu, and transuranic (TRU) elements as a startup fuel. We applied six different absorbing materials to investigate the main operational and safety parameters in the SD-TMSR: natural B 4 C, enriched B 4 C with 90% 10 B, HfB 2 , HfH 1.62 , Eu 2 O 3 , and Gd 2 O 3 . The present work focuses on control rod design, integral and differential control rod worth, shutdown margin, and shadowing effects at steady-state. We employed the SERPENT-2 Monte-Carlo code to calculate the reactivity worth and analyze the performance of the reactivity control system. We showed that 233 U and reactor-grade Pu startup cores maintain adequate shutdown margin with all considered absorbers. Finally, this report proposes a design of control rod clusters that compensate the excess reactivity of the SD-TMSR loaded with different initial fissile material.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Exploratory Study of Different Phase II Collimators

The Large Hadron Collider (LHC) collimation system is installed and commissioned in different phases, following the natural evolution of the LHC performance. To improve cleaning efficiency towards the end of the low beta squeeze at 7TeV, and in stable physics conditions, it is foreseen to complement the 30 highly robust Phase I secondary collimators with low impedance Phase II collimators. At this stage, their design is not yet finalized. Possible options include metallic collimators, graphite jaws with a movable metallic foil, or collimators with metallic rotating jaws. As part of the evaluation of the different designs, the FLUKA Monte Carlo code is extensively used for calculating energy deposition and studying material damage and activation. This report outlines the simulation approach and defines the critical quantities involved.

43 PARTICLE ACCELERATORS↗