Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Sensitivity of the simulation of passive neutron emission from UF 6 cylinders to the uncertainties in both 19 F(α,n) energy spectrum and thick target yield of 234 U in UF 6

Interest in safeguards verification measurements using passive thermal neutron counting to assay 235 U content in large 30B UF 6 canisters has grown in recent years. Here, the prohibitively high cost and impracticality of using reference 30B calibration cylinders extensively will likely make accurate simulations of increasing interest. Accuracy of the simulated response will define the confidence in the predicted response and the extent to which simulations can reasonably be relied upon. With 234 U driven 19 F(α, n) reactions being the main neutron source in low enriched UF 6 the uncertainties of the 19 F(α, n) energy spectrum and the thick target yield of 234 U in UF 6 propagate into the uncertainty in the predicted response and represent a major influence of basic nuclear data. Here sensitivity of the simulated total (Singles) and coincidence (Doubles) count rates are assessed for the Passive Neutron Enrichment Meter using six potential 19 F(α, n) neutron energy spectra over a range of enrichments and material distributions. The results indicate that variations in the Singles and Doubles due to simulated (α, n) neutron spectrum are less than 1.5% for this set of simulated neutron spectra, with dependence varying inversely with enrichment. Singles uncertainty is only slightly less than that of the thick target 19 F(α, n) yield corresponding to the primary neutron source, whereas the 19 F(α, n) yield dependence of the Doubles is reduced by the non-negligible 238 U(SF) coincident neutron emissions. Based on available thick target 19 F(α, n) yield estimates the uncertainty is on the order of 5%, establishing this as the main nuclear data limitation when simulating thermal neutron detectors response for 30B UF 6 storage cylinders. Based on these findings, it appears that the measurement and evaluation of the thick target 19 F(α, n) yield for uranium hexafluoride is due.

19F(α,n) neutron spectrum↗

Low-lying Continuum States in Oxygen Isotopes

Low-lying continuum states of exotic oxygen isotopes are studied, by introducing the Continuum-Coupled Shell Model (CCSM) and an interaction for continuum coupling constructed in a close relation to realistic shell-model interaction. Neutron emission spectra from exotic oxygen isotopes are calculated. The results agree with experiment remarkably well, as an evidence that the continuum effects are stronger than {approx}1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission neutron output measurements at LANSCE

Accurate data for both physical properties and fission properties of materials are necessary to properly model dynamic fissioning systems. To address the need for accurate data on fission neutron energy spectra, especially at outgoing neutron energies below about 200 keV and at energies above 8 MeV, ongoing work at LANSCE involving collaborators from LANL, LLNL and CEA Bruyeres-le-Chatel is extending the energy range, efficiency and accuracy beyond previous measurements. Initial work in the outgoing neutron energy range from 1 to 7 MeV is consistent with current evaluations and provides a foundation for extended measurements. As part of these efforts, a new fission fragment detector that reduces backgrounds and improves timing has been designed fabricated and tested, and new neutron detectors are being assessed for optimal characteristics. Simulations of experimental designs are in progress to ensure that accuracy goals are met. Results of these measurements will be incorporated into evaluations and data libraries as they become available.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron fluences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (En < or = 0.2 eV), resonance (0.2 eV < En < 1.0 MeV) and fast (En > or = 1.0 MeV) neutrons. The first two groups were measured with U.S. 6LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d-1 were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d-1. Inside the spacecraft, a value of 3.5 mrem d-1 was found.

NASA Discipline Number 00-00↗

Neutron influences and energy spectra in the Cosmos-2044 biosatellite orbit

Joint Soviet-American measurements of the neutron component of space radiation (SR) were carried out during the flight of the Soviet biosatellite Cosmos-2044. Neutron flux densities and differential energy spectra were measured inside and on the external surface of the spacecraft. Three energy intervals were employed: thermal (E(sub n) less than or equal to 0.2 eV), resonance (0.2 eV less than E(sub n) less than 1.0 MeV) and fast (E(sub n) greater than or equal to 1.0 MeV) neutrons. The first two groups were measured with U.S. (6)LiF detectors, while fast neutrons were recorded both by U.S. fission foils and Soviet nuclear emulsions. Estimations were made of the contributions to absorbed and equivalent doses from each neutron energy interval and a correlation was presented between fast neutron fluxes, measured outside the satellite, and the phase of solar activity (SA). Average dose equivalent rates of 0.018 and 0.14 mrem d(exp -1) were measured for thermal and resonance neutrons, respectively, outside the spacecraft. The corresponding values for fast neutrons were 3.3 (U.S.) and 1.8 (U.S.S.R.) mrem d(exp -1). Inside the spacecraft, a value of 3.5 mrem d(exp -1) was found.

Dudkin, V. E.↗

Digitized two-parameter spectrometer for neutron-gamma mixed field

This paper shows the results of digital processing of output pulses from combined photon-neutron detector using a commercially available digitizer ACQUIRIS DP 210. The advantage of digital processing is reduction of the apparatus in weight and size, acceleration of measurement, and increased resistance to pile-up of pulses. The neutron and photon spectrum of radionuclide source {sup 252}Cf is presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear data verification based on Monte Carlo simulations of the LLNL pulsed-sphere benchmark experiments (1979 & 1986) using the Mercury code

Livermore's nuclear data group developed a new verification and validation test suite to ensure the quality of data used in application codes. This is based on models of LLNL's pulsed sphere fusion shielding benchmark experiments. Simulations were done with Mercury, a 3D particle transport Monte Carlo code using continuous-energy cross-section libraries. Results were compared to measurements of neutron leakage spectra generated by 14MeV neutrons in 17 target assemblies (for a blank target assembly, H{sub 2}O, Teflon, C, N{sub 2}, Al, Si, Ti, Fe, Cu, Ta, W, Au, Pb, {sup 232}Th, {sup 235}U, {sup 238}U, and {sup 239}Pu). We also tested the fidelity of simulations for photon production associated with neutron interactions in the different materials. Gamma-ray leakage energy per neutron was obtained from a simple 1D spherical geometry assembly and compared to three codes (TART, COG, MCNP5) and several versions of the Evaluated Nuclear Data File (ENDF) and Evaluated Nuclear Data Libraries (ENDL) cross-section libraries. These tests uncovered a number of errors in photon production cross-sections, and were instrumental to the V&V of different cross-section libraries. Development of the pulsed sphere tests also uncovered the need for new Mercury capabilities. To enable simulations of neutron time-of-flight experiments the nuclear data group implemented an improved treatment of biased angular scattering in MCAPM.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron production in lunar habitats - Paper 132

Lunar habitats constructed of either local materials or conventional materials used for spacecraft (such as aluminum) will provide protection for astronauts from solar energetic particles (SEP) and galactic cosmic rays (GCR). Although there are essentially no neutrons in the primary GCR and SEP fields, neutrons are produced by interactions of those fields with the lunar surface and with the lunar habitat. In a habitat, the neutrons can be divided into two categories: albedo neutrons moving generally upward through the habitat, and a generally downward flux created by interactions in the habitat walls. These two neutron fields differ in their energy spectrum, and as a result different mitigation strategies may be needed for different areas of the habitat in order to reduce the dose from neutrons. In this work, we calculate the 'upward' and 'downward' neutron fluences, using a variety of shielding materials and thicknesses. We also investigate the effect of other materials inside the habitat on the neutron fluences. The preliminary transport model calculations performed here verify the effectiveness of a hydrogenous shielding wall material, polyethylene, in reducing the neutron dose inside a simple lunar habitat geometry when compared to walls made of lunar regolith and aluminum. Separate transport model calculations were done for the albedo neutron spectrum rising up from the lunar soil and for GCR particles incident upon the habitat shielding. In the case of GCR ions incident on the habitat, shielding wall made of polyethylene reduced the neutron effective dose by a factor of three, compared to the other two shielding materials. (authors)

36 MATERIALS SCIENCE↗

Influence of defects formed by fast reactor neutrons on exciton luminescence spectra of cadmium sulfide single crystals

The influence of clusters of defects formed by irradiation with neutrons in CdS single crystals on parameters of the spectra of exciton photoluminescence at T {approx} 4.2 K has been studied. It is experimentally established that irradiation of the samples with fast reactor neutrons with energies E {approx} 1 MeV and dose {Phi} = 3 x 10{sup 18} cm{sup -2} brings about a decrease (by approximately 50 times) in the intensity of lines of exciton photoluminescence I{sub 1} ({lambda}{sub m} = 488.7 nm), I{sub 2} ({lambda}{sub m} = 486.9 nm), and I{sub 3} ({lambda}{sub m} = 486.3 nm) with redistribution of intensities in favor of the lines I{sub 1} and I{sub 3} and an increase in their half-width from 2 to 5-6 the positions of their peaks in the emission spectrum. Observed experimental facts are explained on the basis of a model of a two-phase system composed of slightly damaged region in the CdS single crystal in which clusters of defects (formed as a result of irradiation with neutrons) are embedded; these clusters are nanosized grains with a highly disordered structure.

36 MATERIALS SCIENCE↗

SU-E-T-329: Tissue-Equivalent Phantom Materials for Neutron Dosimetry in Proton Therapy

Purpose: To characterize tissue equivalence of phantom materials in terms of secondary neutron production and dose deposition from neutrons produced in radiation therapy phantom materials in the context of proton therapy using Monte Carlo simulations and measurements. Methods: In order to study the influence of material choice on neutron production in therapeutic proton beams, Monte Carlo simulations using the Geant4 and MCNPX-PoliMi transport codes were performed to generate the neutron fields produced by protons of 155 and 200 MeV. A simple irradiation geometry was used to investigate the effect of different materials. The proton beams were stopped in slab phantoms to study the production of secondary neutrons. The investigated materials were water, Lucite, and tissue-equivalent phantom materials (CIRS Inc., Norfolk, VA). Neutron energy spectra and absorbed dose by neutrons and their secondary particles were scored. In addition, simulations were performed for reference tissues (ICRP/ICRU) to assess tissue equivalence with respect to neutron generation and transport. In order to benchmark the simulation results, measurements were performed with a system developed at the University of Michigan; organic liquid scintillators were used to detect the neutron emissions from the irradiation of tissue-equivalent materials. Additionally, the MPPost code was used to calculate the scintillator response from the MCNPX-PoliMi output. Results: The simulated energy spectra and depth dose curves of the neutrons produced in different phantom materials showed similar shape. The differences of spectra and fluences between all studied materials and reference tissues were well within the achievable precision of neutron dosimetry. The shape of the simulated detector response of the liquid scintillators agreed well with measurements on the proton beamline. Conclusion: Based on Geant4 and MCNPX-PoliMi simulations, the investigated materials appear to be suitable to study the production of neutrons in proton therapy. MC simulations were verified with neutron measurements in therapeutic proton beams. This work was funded in part by the ANDANTE grant of the European Commission in the 7th Framework Program.

07 ISOTOPE AND RADIATION SOURCES↗

SNS Sample Activation Calculator Flux Recommendations and Validation

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

43 PARTICLE ACCELERATORS↗

Stellar (n, gamma) cross sections of neutron-rich nuclei

The present measurements were performed by means of the activation technique. Neutrons were produced at the Karlsruhe Van de Graaff accelerator via the {sup 7}Li(p,n){sup 7}Be reaction. For proton energies just above threshold, one obtains a neutron spectrum similar to a Maxwellian distribution for kT = 25 keV. This quasi-stellar neutron spectrum allowed us to measure the Maxwellian averaged cross sections directly. The experimental results of {sup 174,176}Yb, {sup 184,186}W, {sup 190,192}Os, {sup 196,198}Pt, and {sup 202}Hg were extrapolated from kT = 25 keV to lower and higher temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of neutron emission and neutron energy spectrum calculations on a Mega Ampere Spherical Tokamak with directional relativistic spectrum simulator

The recently developed directional relativistic spectrum simulator (DRESS) code has been validated for the first time against numerical calculations and experimental measurements performed on the Mega Ampere Spherical Tokamak . In this validation, the neutron emissivities and rates computed by DRESS are benchmarked against TRANSP/NUBEAM predictions while the neutron energy spectra provided by DRESS taking as input TRANSP/NUBEAM and ASCOT/BBNBI in Gyro-Orbit mode fast ion distributions are validated against proton pulse height spectra measured by the neutron flux monitor. Finally, excellent agreement was found between DRESS and TRANSP/NUBEAM predictions of local and total neutron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-frequency detection of the formation and stabilization of a radiation-induced defect cluster in semiconductor structures

The processes of the formation and stabilization of a radiation-induced defect cluster upon the arrival of a fast neutron to the space-charge region of a semiconductor diode are analyzed. The current pulse formed by secondary electrons is calculated and the spectrum of the signal generated by the diode (detector) under the action of an instantaneous neutron flux of the fission spectrum is determined. The possibility of experimental detection of the picosecond radiation-induced transition processes is discussed.

36 MATERIALS SCIENCE↗

Design of the Next Generation Spallation Target

The purpose of this summary is to detail the studies that enable new nuclear physics experiments currently limited by neutron intensity or energy resolution available at LANSCE. The target is being redesigned so that the Flight Paths (FP) in the upper tier provide a higher intensity in the epithermal and medium energy ranges.

43 PARTICLE ACCELERATORS↗

Redistribution of subsurface neutrons caused by ground ice on Mars

The purpose of this study is to build on that of Squyres and Evans to approach the specific problem of the buried ice deposits explored by Mellon and Jakosky. Therefore, we calculated the depth dependence of equilibrium neutron energy spectra and related neutron-capture gamma ray production rates for a semi-infinite layer of regolith having a Chryse-fines composition containing 5, 10, and 18 wt percent of water. This high water-content layer was buried beneath the same regolith containing 1 percent water at depths of 20, 40, and 80 g/ sq. cm. A 16-g/sq. cm atmosphere having the abundances measured by Owen et al. was included throughout. We also calculated the effects of a 30-g/sq. cm-thick layer containing 18 percent water embedded within a semi-finite regolith containing 1 percent water, at depths of 20, 40, and 80 g/sq. cm below the atmosphere-surface interface.

Feldman, W. C.↗