Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Robotic Assisted Microsurgery - RAMS FY'97

JPL and Microdexterity Systems collaborated to develop new surgical capabilities. They developed a Robot Assisted Microsurgery (RAM) tool for surgeons to use for operating on the eye, ear, brain, and blood vessels with unprecedented dexterity. A surgeon can hold the surgical instrument with motions of 6 degrees of freedom with an accuracy of 25 microns in a 70 cu cm workspace. In 1996 a demonstration was performed to remove a microscopic particle from a simulated eyeball. In 1997, tests were performed at UCLA to compare telerobotics with mechanical operations. In 5 out of 7 tests, the RAM tool performed with a significant improvement of preciseness over mechanical operation. New design features include: (1) amplified forced feedback; (2) simultaneous slave robot instrumentation; (3) index control switch on master handle; and (4) tool control switches. Upgrades include: (1) increase in computational power; and (2) installation of hard disk memory storage device for independent operation and independent operation of forceps. In 1997 a final demonstration was performed using 2 telerobotics simultaneously in a microsurgery suture procedure to close a slit in a thin sheet of latex rubber which extended the capabilities of microsurgery procedures. After completing trials and demonstrations for the FDA the potential benefits for thousands of operations will be exposed.

Source record↗

Low-Noise Amplifier for 100 to 180 GHz

A three-stage monolithic millimeter-wave integrated-circuit (MMIC) amplifier designed to exhibit low noise in operation at frequencies from about 100 to somewhat above 180 GHz has been built and tested. This is a prototype of broadband amplifiers that have potential utility in diverse applications, including measurement of atmospheric temperature and humidity and millimeter-wave imaging for inspecting contents of opaque containers. Figure 1 depicts the amplifier as it appears before packaging. Figure 2 presents data from measurements of the performance of the amplifier as packaged in a WR-05 waveguide and tested in the frequency range from about 150 to about 190 GHz. The amplifier exhibited substantial gain throughout this frequency range. Especially notable is the fact that at 165 GHz, the noise figure was found to be 3.7 dB, and the noise temperature was found to be 370 K: This is less than half the noise temperature of the prior state of the art.

Kangaslahti, Pekka↗

K-band FET amplifier for satellite downlink

State-of-the-art performance is demonstrated with solid-state amplifiers in K-band. The amplifier provides 8.2 watts of power with 39 dB gain over a frequency band of 1.4 GHz. Nonlinearity analyses of solid-state amplifiers suggest that system performance can be improved significantly by using an FET amplifier. Preliminary investigations reveal that the solid-state amplifiers can be space-qualified and can be expected to replace the TWTA in many communication links in the near future. It is pointed out that with improvements in device technology, the power, bandwidth and efficiency of solid-state amplifiers using FETs can be further improved. With FETs operating at a junction temperature of less than 125 C, solid-state amplifiers are inherently reliable, indicating a ten-year mean time to failure.

Goel, J.↗

SENSEI: Characterization of Single-Electron Events Using a Skipper Charge-Coupled Device

We use a science-grade skipper charge-coupled device (skipper CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89±0.77)×10 -4 e - /pix/day, and an unprecedentedly low spurious charge contribution of (1.52±0.07)×10 -4 e - /pix, which is exposure independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing research and development efforts of skipper and conventional CCDs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as ``dark counts'': dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensating for Amplifier Non-Linearity in a SEL Controller

The Self-Excited Loop (SEL) architecture, used in some continuous-wave (CW) superconducting linacs, relies on a positive feedback mechanism that requires carefully defined operating limits to ensure stable operation. These limits are typically derived from amplifier calibration, which characterizes the relationship between forward power and DAC drive. However, amplifier non-linearity often prevents a simple linear fit of this characteristic, introducing errors that can compromise stability. To address this, we present a modified calibration procedure that incorporates amplifier non-linearity into the SEL framework. The approach is validated with test data from a 32 kW solid-state amplifier (SSA) and a cavity emulator developed for the Fermilab PIP-II linac.

Raman, S. [Fermilab] (ORCID:0009000735937206)↗

New Results from the Search for Low-Mass Weakly Interacting Massive Particles with the CDMS low ionization Threshold Experiment

The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite.

New Results, Low-Mass, Mazzive Particles, CDMS Low↗

Vibrator elapsed time is automatically controlled

Circuit determines elapsed operating time for vibrators when three vibrators are located in one room and are powered by two amplifiers through either of two control systems. It operates the control system elapsed time clocks only when voltage is applied to the vibrator armatures.

Burowick, E. A.↗

Compensating for Amplifier Non-Linearity in a SEL Controller

The SEL architecture used commonly in CW superconducting linacs is a positive feedback system that requires determining the correct limits for the operating conditions to ensure stable operation. These limits are determined from the results of the amplifier calibration which characterizes the dac drive(forward power) against the cavity field. When the amplifier non-linearity precludes a simple linear fit for this characteristic, its modification to account for the amplifiers non-linearity is essential to operate the system in the SEL architecture. This process is described with test data from a 32kW SSA for the PIP-II linac.

Sankar Raman, Shrividhyaa [Fermilab]↗

Optical Modem Enabling Broadband Datacom Links for Crewed Cis-Lunar Missions

We report on the design, development, and testing of our high-power broadband optical modem supporting NASA’s crewed Artemis-2 mission. The O2O modem will be mounted in the crewed Orion module and provide a broadband 505,000 km bi-directional optical link back to earth while en route to the moon. The full-duplex modem consists of a high-power optical transmitter and receiver optimized for serially-concatenated pulse-position modulation (SCPPM). The transmitter is a master-oscillator power-amplifier optical architecture using efficient cladding-pumped amplification in erbium-ytterbium co-doped fiber. The transmitter outputs up to 1 W at ≈1550 nm (limited for eye safety) and supports 6 different user-rates ranging from 20.39 Mb/s to 260.95 Mb/s using PPM16 and PPM32 modulation formats. The optical receiver supports two user-rates: 10.19 Mb/s and 20.39 Mb/s with both rates employing PPM32. The narrowband receiver filtering is optimized to simultaneously accept four separate wavelength channels to mitigate atmospherics through spatial diversity. A configurable interleaver provides additional protection against atmospherics-based signal fading and a powerful soft-decision error correction scheme enables highly sensitive detection. The measured sensitivities at the two bit-rates are -73.8 and -71.8dBm, respectively. The architecture was designed for reliable operation in space, featuring automatic hardware interlocks, pump sparing for the amplifiers, and autonomous operation of all internal hardware and software control loops. The protoflight unit (PFU) was put through rigorous environmental testing which included pyroshock, vibration, electromagnetic interference/compatibility, and thermal-vacuum testing. The modem successfully passed all the environmental screening and has been declared at Technology Readiness Level (TRL) 6.

space communications↗

Satellite Communications Applications Research

This report describes work performed by SDL in the development of monolithically-integrated master oscillator power amplifiers under the NASA-SCAR research contract. The goals of the program were to demonstrate high power diffraction-limited operation from a semiconductor laser with the following characteristics: (1) Output power of 0.5 to 1.0 W continuous-wave (cw); (2) Single spectral mode with greater than 20 dB of side mode suppression; (3) Single spatial mode operation; (4) Modulation capability of 0.5 GHz; and (5) Operating wavelength between 830-860 nm. Cw diffraction-limited output powers as high as 2.2 W were achieved while maintaining a single longitudinal mode. Side mode suppression ratios greater than 20 dB are typically obtained. The single spatial mode output has a Strehl ratio estimated at 0.85, and a high-speed modulation capability was demonstrated with a small-signal 3-dB roll-off at 1.0 GHz. Finally, all of this performance was obtained in the 860 nm wavelength band, which corresponds to the peak sensitivity of Si detectors. During the first option period, three deliverables were fabricated and delivered that included 1 distributed Bragg reflector (DBR) laser operating at 970 nm, 1 DBR laser operating at 860 nm, and one monolithic flared amplifier master oscillator power amplifier (MFA-MOPA) providing 0.5 W cw diffraction-limited output. During the second option period, a total of 5 MFA-MOPA devices were delivered, each operating to better than 1 W cw diffraction-limited at 860 nm.

Lang, Robert J.↗

Automatic gain control

An automatic gain control (AGC), designed to operate with the prototype Loran-C receiver, is described. The device is used to eliminate error which occurs when signals are received at different magnitudes. The automatic gain control is a three transistor circuit which requires a constant dc voltage of 8 volts. Tests conclude that this value may be in the range of 4 to 12 v without change in circuit performance. Two transistors are cascaded to pass and amplify the input signal. Their gain is controlled by a third transistor which itself is controlled by an external AGC voltage between 0 and 8 volts dc. The integrated circuit used is an 8 pin chip, which is a differential cascade amplifier designed for use in communications operating at frequencies from dc to 120 MHz. The integrated circuit was balanced for AGC capabilities, and has a wide operating current range. The maximum input current at pins 1 and 5 is 0.1 mAmps. AGC testing is described.

Roman, J. P.↗

Single-pulse picking at kHz repetition rates using a Ge plasma switch at the free-electron laser FELBE

We demonstrate a system for picking of mid-infrared and terahertz (THz) radiation pulses from the free-electron laser (FEL) FELBE operating at a repetition rate of 13 MHz. Single pulses are reflected by a dense electron-hole plasma in a Ge slab that is photoexcited by amplified near-infrared (NIR) laser systems operating at repetition rates of 1 kHz and 100 kHz, respectively. The peak intensity of picked pulses is up to 400 times larger than the peak intensity of residual pulses. The required NIR fluence for picking pulses at wavelengths in the range from 5 μm to 30 μm is discussed. In addition, we show that the reflectivity of the plasma decays on a time scale from 100 ps to 1 ns dependent on the wavelengths of the FEL and the NIR laser. The plasma switch enables experiments with the FEL that require high peak power but lower average power. Furthermore, the system is well suited to investigate processes with decay times in the μs to ms regime, i.e., much longer than the 77 ns long pulse repetition period of FELBE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The multi-mode gyrotron

It is possible to provide a situation in the gyrotron when it possesses a dense spectrum of axial eigenmodes having different frequencies but almost similar Q-factors. In this case, the single-frequency operation of the gyrotron is provided due to non-linear competition of the eigenmodes. It is shown that such an approach opens a way to provide in gyrotrons a close-to-continuous frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-order-mode harmonic multiplying gyrotron traveling-wave amplifier in W band

Harmonic multiplying gyrotron traveling-wave amplifiers (gyro-TWAs) allow for magnetic field reduction and frequency multiplication. To avoid absolute instabilities, this work proposes a W-band harmonic multiplying gyro-TWA operating at low-order modes. By amplifying a fundamental harmonic TE{sub 11} drive wave, the second harmonic component of the beam current initiates a TE{sub 21} wave to be amplified. Absolute instabilities in the gyro-TWA are suppressed by shortening the interaction circuit and increasing wall losses. Simulation results reveal that compared with Ka-band gyro-TWTs, the lower wall losses effectively suppress absolute instabilities in the W-band gyro-TWA. However, a global reflective oscillation occurs as the wall losses decrease. Increasing the length or resistivity of the lossy section can reduce the feedback of the oscillation to stabilize the amplifier. The W-band harmonic multiplying gyro-TWA is predicted to yield a peak output power of 111 kW at 98 GHz with an efficiency of 25%, a saturated gain of 26 dB, and a bandwidth of 1.6 GHz for a 60 kV, 7.5 A electron beam with an axial velocity spread of 8%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development FD-SOI MOSFET Amplifiers for Integrated Read-Out Circuit of Superconducting-Tunnel-Junction Single-Photon-Detectors

We proposed a new high-resolution single-photon infrared spectrometer for search for radiative decay of cosmic neutrino background (CνB). The superconducting-tunnel-junctions(STJs) are used as a single-photon counting device. Each STJ consists of Nb/Al/Al x O y /Al/Nb layers, and their thicknesses are optimized for the operation temperature at 370 mK cooled by a 3 He sorption refrigerator. Our STJs achieved the leak current 250 pA, and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio (S/N). FD-SOI MOSFETs can be operated at cryogenic temperature of 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a nonlinear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors is 0.4 mV, and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET-based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp is required to have a fast response (GBW ≥ 100 MHz), and it must have low power dissipation as compared to the cooling power of refrigerator.

47 OTHER INSTRUMENTATION↗

Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter

Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Invasive Beam Detection in a High-Average Power Electron Accelerator

For a free-electron laser (FEL) to work effectively the electron beam quality must meet exceptional standards. In the case of an FEL operating at infrared wavelengths in an amplifier configuration the critical phase space tends to be in the longitudinal direction. Achieving high enough longitudinal phase space density directly from the electron injector system of such an FEL is difficult due to space charge effects, thus one needs to manipulate the longitudinal phase space once the beam energy reaches a sufficiently high value. However, this is fraught with problems. Longitudinal space charge and coherent synchrotron radiation can both disrupt the overall phase space, furthermore, the phase space disruption is exacerbated by the longitudinal phase space manipulation process required to achieve high peak current. To achieve and maintain good FEL performance one needs to investigate the longitudinal emittance and be able to measure it during operation preferably in a non-invasive manner. Using the electro-optical sampling (EOS) method, we plan to measure the bunch longitudinal profile of a high-energy (~120-MeV), high-power (~10kW or more FEL output power) beam.

43 PARTICLE ACCELERATORS↗