Search NASA⌕ Search

SEARCH · Search NASA

Results for “PETRO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Evaluation of 2-μm Pulsed Integrated Path Differential Absorption Lidar for Carbon Dioxide Measurement—Technology Developments, Measurements, and Path to Space

The societal benefits of understanding climate change through the identification of global carbon dioxide sources and sinks led to the recommendation for NASA's Active Sensing of Carbon Dioxide Emissions over Nights, Days, and Seasons space-based mission for global carbon dioxide measurements. For more than 15 years, the NASA Langley Research Center has developed several carbon dioxide active remote sensors using the differential absorption lidar technique operating at 2-μm wavelength. Recently, an airborne double-pulsed integrated path differential absorption lidar was developed, tested, and validated for atmospheric carbon dioxide measurement. Results indicated 1.02% column carbon dioxide measurement uncertainty and 0.28% bias over the ocean. Currently, this technology is progressing toward triple-pulse operation targeting both atmospheric carbon dioxide and water vapor-the dominant interfering molecule on carbon dioxide remote sensing. Measurements from the double-pulse lidar and the advancement of the triple-pulse lidar development are presented. In addition, measurement simulations with a space-based IPDA lidar, incorporating new technologies, are also presented to assess feasibility of carbon dioxide measurements from space.

Singh, Upendra N.↗

Small Spacecraft Technology Program

The Small Spacecraft Technology Program (SSTP) develops and demonstrates new capabilities employing the unique features of small spacecraft for science, exploration and space operations. Small spacecraft represent an emerging class of satellites, robots and systems that exploit their small size to take advantage of ridesharelaunch opportunities at reduced cost.Small spacecraft also utilize the growingamount of technical capabilities that weare witnessing in the high technology and electronics industries. As a result,small spacecraft and platforms arebecoming more and more capable as their overall size continues to decrease.

Fishman, Julianna L.↗

The Origins Space Telescope

The Origins Space Telescope will trace the history of our origins from the time dust and heavy elements permanently altered the cosmic landscape to present-day life. How did galaxies evolve from the earliest galactic systems to those found in the universe today? How do habitable planets form? How common are life-bearing worlds? To answer these alluring questions, Origins will operate at mid- and far-infrared wavelengths and offer powerful spectroscopic instruments and sensitivity three orders of magnitude better than that of Herschel, the largest telescope flown in space to date. After a 3 ½ year study, the Origins Science and Technology Definition Team will recommend to the Decadal Survey a concept for Origins with a 5.9-m diameter telescope cryo cooled to 4.5 K and equipped with three scientific instruments. A mid-infrared instrument (MISC-T) will measure the spectra of transiting exoplanets in the 2.8 – 20 μm wavelength range and offer unprecedented sensitivity, enabling definitive biosignature detections. The Far-IR Imager Polarimeter (FIP) will be able to survey thousands of square degrees with broadband imaging at 50 and 250 μm. The Origins Survey Spectrometer (OSS) will cover wavelengths from 25 – 588 μm, make wide-area and deep spectroscopic surveys with spectral resolving power R ~ 300, and pointed observations at R ~ 40,000 and 300,000 with selectable instrument modes. Origins was designed to minimize complexity. The telescope has a Spitzer-like architecture and requires very few deployments after launch. The cryo-thermal system design leverages JWST technology and experience. A combination of current-state-of-the-art cryocoolers and next-generation detector technology will enable Origins’ natural background limited sensitivity.

Leisawitz, D.↗

Plankton, Aerosol, Cloud, Ocean Ecosystem (PACE) Mission Integration and Testing

This paper describes the plans, flows, key facilities, components and equipment necessary to fully integrate, functionally test and qualify the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Observatory. PACE is currently in the design phase of mission implementation. It is scheduled to launch in 2022, extending and improving NASA's twenty-year record of satellite observations of global ocean biology, aerosols and clouds. PACE will advance the assessment of ocean health by measuring the distribution of phytoplankton, which are small plants and algae that sustain the marine food web. It will also continue systematic records of key atmospheric variables associated with air quality and the Earth's climate. The PACE observatory is comprised of the spacecraft and three instruments, an Ocean Color Instrument (OCI) and two polarimeters, the Hyper-Angular Rainbow Polarimeter 2 (HARP2) and the Spectro-Polarimeter for Exploration (SPEXone). The spacecraft and the OCI, which is the primary instrument, are developed and integrated at the NASA Goddard Space Flight Center (GSFC). The OCI is a hyper-spectral scanning (HSS) radiometer designed to measure spectral radiances from the ultraviolet to shortwave infrared (SWIR) to enable advanced ocean color and heritage cloud and aerosol particle science. The HARP2 and SPEXone are secondary instruments on the PACE observatory, acquired outside of GSFC. The Hyper-Angular Rainbow Polarimeter instrument (HARP2) is a wide swath imaging polarimeter that is capable of characterizing atmospheric aerosols for purposes of sensor atmospheric correction as well as atmospheric science. The SPEXone provides atmospheric aerosol and cloud data at high temporal and spatial resolution. This paper will focus on the Integration and Test (I&T) activities for the PACE mission at NASA GSFC. This I&T phase consists of mechanical, electrical and thermal integration and test of all the spacecraft subsystems and the integration of the instruments with the spacecraft. The PACE observatory environmental tests include electromagnetic interference (EMI)/electromagnetic compatibility (EMC), vibration, acoustics, shock, thermal balance, thermal vacuum, mass properties and center of gravity. This paper will also discuss the observatory shipment to the launch site as well as the launch site processing.

Petro, Susanna↗

Laser Energy Monitor for Triple-Pulse 2-μm IPDA Lidar Application

Integrated path differential absorption (IPDA) lidar is an active remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. An advanced 2-μm triple-pulse IPDA lidar was developed at NASA Langley Research Center for active sensing of carbon dioxide and water vapor simultaneously. The IPDA transmitter produces three successive laser pulses separated by a short interval (200 μs) with a repetition rate of 50Hz. Measurement of laser pulse energy accurately is a prerequisite for the retrieval of gas mixing ratios from IPDA. The design and calibration of a 2-μm triple-pulse laser energy monitor are presented. Due to the short interval between the three transmitted pulses, conventional thermal energy monitors underestimate the total transmitted energy. The design is based on a high speed, extended range InGaAs pin quantum detector suitable for separating the three pulse events. Pulse integration is applied for converting the detected pulse power into energy. The results obtained from the laser energy monitor were compared to an ultra-fast energy-meter reference for energy scaling and verification. High correlations between the pin energy monitor and the total transmitted energy were obtained. The objective of this development is to reduce measurement biases and errors using the triple-pulse IPDA technique.

Refaat, Tamer F.↗

Airborne, Direct-Detection, 2-μm Triple-Pulse IPDA Lidar for Simultaneous and Independent Atmospheric Water Vapor and Carbon Dioxide Active Remote Sensing

Atmospheric water vapor and carbon dioxide are important greenhouse gases that significantly contribute to the global radiation budget on Earth. A 2-micron triple-pulse, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric carbon dioxide and water vapor concentration measurements using direct detection was developed at NASA Langley Research Center. This active remote sensing instrument provides an alternate approach with significant advantages for measuring atmospheric concentrations of the gases. A high energy pulsed laser transmitter approach coupled with sensitive receiver detection provides a high-precision measurement capability by having a high signal-to-noise ratio. This paper presents the concept, development, integration and testing of the 2-micron triple-pulse IPDA. The integration includes the various IPDA transmitter, receiver and data acquisition subsystems and components. Ground and airborne testing indicated successful operation of the IPDA lidar.

Refaat, Tamer F.↗

Frequency Control of Multi-Pulse 2-micron Laser Transmitter for Atmospheric Carbon Dioxide Measurement

Laser sources with highly stabilized emission wavelength is of paramount importance for a long term atmospheric carbon dioxide (CO2) measurement from a space platform. Integrated Path Differential Absorption (IPDA) lidar is a promising instrument for such a task. The design of a laser transmitter, with emphasis on the method used to control and select several wavelengths, is presented. This multi-pulsed, injection seeded, 2-μm transmitter uses a Ho:Tm:YLF laser crystal which has matching emission to the absorption of CO2 in the R30 spectroscopic area. The injection seeded laser produces triple single longitudinal mode transform limited line width pulses with a total of 80 mJ at a repetition rate of 50 Hz.

Petros, Mulugeta↗

Ground Testing of 2-µm Triple-Pulse IPDA Lidar for Carbon Dioxide and Water Vapor Measuremets

A triple-pulse, 2-µm, Integrated Path Differential Absorption (IPDA) lidar was developed at NASA Langley Research Center. This active remote sensing instrument provides a technique for measuring atmospheric carbon dioxide and water vapor simultaneously and independently. A 2-µm high-energy pulsed laser is incorporated for the IPDA transmitter, which provides high signal-to-noise ratio measurements using a commercial direct detection system. This results in a high-precision measurement capability for the low troposphere weighted-average column dry-air volume mixing ratio of the gases. Recent IPDA ground testing indicated carbon dioxide and water vapor measurements sensitivities of 8% and 14%, respectively and biases of 0.1%. However, using the R30 centerline position for the on-line enhances the CO2 measurement sensitivity to 0.6%.

Refaat, Tamer F.↗

TPSAS-NF1676L-12987-DND

Preliminary results of the LaRC DAWN coherent wind lidar performance in NASA's GRIP airborne campaign of 2010.

M. J. Kavaya↗

TPSAS-NF1676L-14096-DND

This technology development was initiated during NASA Earth Science Technology Office (ESTO) funded Laser Risk Reduction Program (LRRP) with the objective to develop a Thulium (Tm) fiber laser pumped Holmium (Ho) solid-state laser that generates laser pulses in the 2?m wavelength for pulsed CO2 DIAL/IPDA instrument. The key performance characteristics of this laser, such as energy, pulse repetition rate, pulse width, efficiency, frequency accuracy and stability, will meet or exceed the needs of the NASA Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) transmitter as currently envisioned. This space qualifiable laser architecture utilizes fiber laser and solid-state crystal laser technologies. One of the outstanding properties of the fiber laser is its efficiency. However, it inherently has low damage threshold at high energy pulses. On the other hand, the solid state laser has the capability to produce Joule-level energy at 2?m wavelength. The proposed laser combines the advantages of both lasers to provide the desired energy with high efficiency.

Upendra N Singh↗

TPSAS-NF1676L-14130-DND

We report on remote sensing measurements of atmospheric carbon dioxide by a double pulsed 2-micron coherent differential absorption lidar technique.

Jirong Yu↗