Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Piping design considerations in a solar-Rankine power plant

Two of the main parameters in sizing the piping of a solar power plant are the working pressure of the vapor leaving the solar collectors, and the type of working fluid used. Numerical examples for each case are given using the graphical Moody friction charts and the analytical Darcy-Weisbach equation. Different working pressures of steam vapor in the solar collector-turbine pipe connection indicate their major role in the design. The size variation was found not to be in linear proportion to vapor density variations. On the other hand, high molecular weight organic fluids such as R-11 and R-113, when compared with water, show insignificant changes in piping sizes.

Lansing, F. L.↗

Heat pipes and their use in technology

Heat pipes may be employed as temperature regulators, heat diodes, transformers, storage batteries, or utilized for transforming thermal energy into mechanical, electric, or other forms of energy. General concepts were established for the analysis of the transfer process in heat pipes. A system of equations was developed to describe the thermodynamics of steam passage through a cross section of a heat pipe.

Vasilyev, L.↗

Evaluation of commercially-available spacecraft-type heat pipes

As part of an effort to develop reliable, cost effective spacecraft thermal control heat pipes, life tests on 30 commercially available heat pipes in 10 groups of different design and material combinations were conducted. Results for seven groups were reported herein. Materials are aluminum and stainless steel, and working fluids are methanol and ammonia. The formation of noncondensible gas was observed for times exceeding 11,000 hours. The heat transport capacities of the pipes were also determined.

Kaufman, W. B.↗

Development of a cryogenic rotating heat pipe joint

The performance of two critical technology components required for a continuously rotatable heat pipe: (1) a low-leakage rotatable coupling for the heat pipe pressure vessel, and (2) a rotatable internal wick, is reported. Performance and leakage requirements were established based on 12 months operation of a cryogenic rotatable heat pipe on a satellite in earth orbit.

Source record↗

Transverse flat plate heat pipe experiment

This paper describes a Shuttle-launched flight experiment to evaluate the performance of a transverse flat plate heat pipe that serves as an integral temperature control/mounting panel for electronic equipment. A transverse heat pipe is a gas-controlled variable conductance heat pipe that can handle relatively large thermal loads. An experiment designed to flight test the concept over a 6-9 month period is self-sufficient with respect to electrical power, timing sequences, and data storage.

Edelstein, F.↗

Titanium-alloy, metallic-fluid heat pipes for space service

Reactivities of titanium limit its long-term terrestrial use for unprotected heat-pipe envelopes to about 870 K (1100 F). But this external thermochemical limitation disappears when considerations shift to space applications. In such hard-vacuum utilization much higher operating temperatures are possible. Primary restrictions in space environment result from vaporization, thermal creep, and internal compatibilities. Unfortunately, a respected head-pipe reference indicates that titanium is compatible only with cesium from the alkali-metal working-fluid family. This problem and others are subjects of the present paper which advocates titanium-alloy, metallic-fluid heat pipes for long-lived, weight-effective space service between 500 and 1300 K (440 and 1880 F).

Morris, J. F.↗

CTS-type variable conductance heat pipes for SEP FM/PPU

The development effort for, and the fabrication and testing of, six CTS-type variable conductance heat pipes is described. The heat pipes are constructed of stainless steel, use methanol as a working fluid, and a nitrogen/helium mixture as the control gas. The wicking structure consists of interior wall grooves, a metal-felt diametral slab wick, and two wire-mesh arteries. The heat pipes are used to cool two Functional Model/Power Processing Units in a Solar Electric Propulsion prototype BIMOD thruster subsystem assembly. The Power Processing Units convert the electric power from a spacecraft solar array system to the voltages required to operate the electric thrusters which are part of the BIMOD assembly.

Antoniuk, D.↗

Design, fabrication and test of a hydrogen heat pipe

Re-entrant groove technology was extended to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3 mm diameter vapor core. Each axial groove is 0.775 mm diameter with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Modifications to the basic re-entrant groove profile resulted in improved overall performance. While the maximum heat transport capacity decreased slightly to 103 w-m the static wicking height increased markedly to 4.5 cm. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady state performance data taken over a 19 to 23 K temperature range indicated: (1) maximum heat transport capacity of 5.4 w-m; (2) static wicking height of 1.42 cm; and (3) overall heat pipe conductance of 1.7 watts/deg C.

Alario, J.↗

Modal content of noise generated by a coaxial jet in a pipe

Noise generated by air flow through a coaxial obstruction in a long, straight pipe was investigated with concentration on the modal characteristics of the noise field inside the pipe and downstream of the restriction. Two measurement techniques were developed for separation of the noise into the acoustic duct modes. The instantaneous mode separation technique uses four microphones, equally spaced in the circumferential direction, at the same axial location. The time-averaged mode separation technique uses three microphones mounted at the same axial location. A matrix operation on time-averaged data produces the modal pressure levels. This technique requires the restrictive assumption that the acoustic modes are uncorrelated with each other. The measured modal pressure spectra were converted to modal power spectra and integrated over the frequency range 200-6000 Hz. The acoustic efficiency levels (acoustic power normalized by jet kinetic energy flow), when plotted vs. jet Mach number, showed a strong dependence on the ratio of restriction diameter to pipe diameter. The acoustic energy flow analyses based on the thermodynamic energy equation and on the results of Mohring both resulted in orthogonality properties for the eigenfunctions of the radial mode shape equation. These orthogonality relationships involve the eigenvalues and derivatives of the radial mode shape functions.

Kerschen, E. J.↗

Modular heat pipe radiators for enhanced Shuttle mission capabilities

Current heat pipe radiator technology is reviewed and the results from three state-of-the-art hardware programs are summarized. Heat pipe radiators are shown to be an improvement over all-fluid loop panels for long duration space missions, when micrometeoroid survivability is important. Finally, several heat pipe radiator design concepts are presented which would enhance Shuttle mission capabilities by either extending mission life and/or augmenting heat rejection capability.

Alario, J.↗

A high performance cocurrent-flow heat pipe for heat recovery applications

By the introduction of a plate-and-tube separator assembly into a heat pipe vapor core, it has been demonstrated that axial transport capacity in reflux mode can be improved by up to a factor of 10. This improvement is largely the result of eliminating the countercurrent shear that commonly limits reflux heat pipe axial capacity. With benzene, axial heat fluxes up to 1800 W/sq cm were obtained in the temperature range 40 to 80 C, while heat flux densities up to 3000 W/sq cm were obtained with R-11 over the temperature range 40 to 80 C. These very high axial capacities compare favorably with liquid metal limits; the sonic limit for liquid sodium, for example, is 3000 W/sq cm at 657 C. Computational models developed for these cocurrent flow heat pipes agreed with experimental data within + or - 25%.

Saaski, E. W.↗

Orifice Blocks Heat Pipe in Reverse Mode

High forward-mode conductance is combined with rapid reverse-mode shutoff in a heat pipe originally developed to cool spacecraft payloads. A narrow orifice within the pipe "chokes off" the evaporator if heat sink becomes warmer than source. During normal operation, with source warmer than sink, orifice has little effect. Design is simpler and more compact than other thermal-diode heat pipes and requires no special materials, forgings, or unusual construction techniques.

Alario, J. P.↗

SEP BIMOD variable conductance heat pipes acceptance and characterization tests

A series of six heat pipes, similar in design to those flown on the Comunications Technology Satellite Hermes, for use in a prototype Solar Electric Propulsion BIMOD thrust module are evaluated. The results of acceptance and characterization tests performed on the heat pipe subassemble are reported. The performance of all the heat pipes met, or exceeded, design specifications.

Hemminger, J. A.↗

Design, fabrication and test of liquid metal heat-pipe sandwich panels

Integral heat-pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich panel construction, were fabricated and tested. The designs utilize two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and potassium or sodium as the working fluid. Panels were tested by radiant heating, and the results indicate successful heat pipe operation at temperatures of approximately 922 K (1200 F). These panels, in addition to solving potential thermal stress problems in an Airframe-Integrated Scramjet Engine, have potential applications as cold plates for electronic component cooling, as radiators for space platforms, and as low distortion, large area structures.

Basiulis, A.↗

Design, fabrication and test of liquid metal heat-pipe sandwich panels

Integral heat-pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich panel construction, were fabricated and tested. The designs utilize two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and potassium or sodium as the working fluid. Panels were tested by radiant heating, and the results indicate successful heat pipe operation at temperatures of approximately 922K (1200F). These panels, in addition to solving potential thermal stress problems in an Airframe-Integrated Scramjet Engine, have potential applications as cold plates for electronic component cooling, as radiators for space platforms, and as low distortion, large area structures.

Basiulis, A.↗

High capacity heat pipe performance demonstration

A high capacity heat pipe which will operate in one-g and in zero-g is investigated. An artery configuration which is self-priming in one-g was emphasized. Two artery modifications were evolved as candidates to achieve one-g priming and will provide the very high performance: the four artery and the eight artery configurations. These were each evaluated analytically for performance and priming capability. The eight artery configuration was found to be inadequate from a performance standpoint. The four artery showed promise of working. A five-inch long priming element test article was fabricated using the four artery design. Plexiglas viewing windows were made on each end of the heat pipe to permit viewing of the priming activity. The five-inch primary element would not successfully prime in one-g. Difficulties on priming in one-g raised questions about zero-g priming. Therefore a small test element heat pipe for verifying that the proposed configuration will self-prime in zero-g was fabricated and delivered.

Source record↗

A regression model for the temporal development of soil pipes and associated gullies in the alluvial-fill valley of the Rio Puerco, central New Mexico

On Mars, the association of gullied escarpments and chaotic terrain is evidence for failure and scarp retreat of poorly consolidated materials. Some martian gullies have no surface outlets and may have drained through subterranean channels. Similar features, though on a much smaller scale, can be seen in alluvium along terrestrial river banks in semiarid regions, such as the Rio Puerco Valley of central New Mexico. Many of the escarpments along the Rio Puerco are developing through formation of collapse gullies, which drain through soil pipes. Gully development can be monitored on aerial photographs taken in 1935, 1962, and 1980. A regression model was developed to quantify gully evolution over a known time span. Soil pipes and their associated collapse gullies make recognizable signatures on the air photos. The areal extent of this signature can be normalized to the scarp length of each pipe-gully system, which makes comparisons between systems possible.

Condit, C. D.↗

Transverse flat-plate heat pipe experiment (S1005)

The objective of this experiment is to evaluate the zero-g performance of a number of transverse flat plate heat pipe modules. Performance will include the transport capability of the pipes, the temperature drop, and the ability to maintain temperature over varying duty cycles and environments. Additionally, performance degradation, if any, will be monitored over the length of the Long Duration Exposure Facility (LDEF) mission. This information is necessary if heat pipes are to be considered for system designs where they offer benefits not available with other thermal control techniques.

Owen, J. W.↗