Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

A Probability-based Model for Cost-effective Integration of Renewables into the Electricity Grid (Final Technical Report)

Funded by the U.S. Department of Energy during 2017-2019, the resource adequacy evaluation and production costing tool, called MATPLAN (MATlab and probability-based PLANning), was developed. MATPLAN can take into account the variable nature of renewable energy sources (both solar PV and wind farms), rather than considering deterministic data as in the current practice. It combines both probabilistic and optimization techniques to allow the determination of optimal system expansion policy and perform effective load carrying capacity (ELCC) analysis of a system with high renewable penetration. This is in contrast to the current practice that treats these variable sources as negative loads. This tool expects to benefit system planners by enabling them to consider renewable energy sources as options for their expansion plans. System operators can use MATPLAN to calculate the capacity credit for each solar/wind farm using probabilistic forecasts, thus enabling quantification of the operating reserve requirements to cope with uncertainty and variability of solar/wind output committed in the market.

14 SOLAR ENERGY↗

Living Filter Designs for In-Line Recovery and Sorting of Critical materials

This project explored “bio-mining” of critical materials from electronic waste (E-waste) streams by developing living filters arrays capable of recovering these materials, focusing on the platinum group metals (PGMs) and rare earth elements (REEs). While highly toxic, E-waste is considered a valuable “urban mine” as it contains critical materials such as PGMs and REEs with orders of magnitude higher purity than the richest ores. The aim of the project was to: (1) develop mechanically robust, silk-based biomaterial filtration membranes that can capture REEs from dilute aqueous waste; (2) design and build 3D bioprinted living filters containing encapsulated electrochemically active bacteria (EAB) capable of bio-reducing PGMs and recovering them from waste streams; and (3) constructing combined living filter arrays using both components to efficiently capture REE and PGM from the same waste stream. The developed silk-based filtration membranes were self-assembled using silk-nanofibrils (SNFs) derived from silkworm (Bombyx mori) cocoons in conjunction with recombinant silk-elastin-like proteins (SELPs), which contained lanthanide-binding peptide tags (LBTs) with a high affinity and specificity towards REEs. These 100% biodegradable protein-based membranes were capable of recovering up to 85% of model REE ions (Tb 3+ ) filtered through the membrane, with ~50% recovery achieved in the presence of high concentrations (100X) of common interfering metals (Ca 2+ , Cu 2+ , Fe 3+ , Zn 2+ ). REE captured by the membranes were easily recovered by applying a low pH desorption buffer. The membranes also demonstrated substantial reusability, with only a 30% loss in binding capacity after 4 cycles of REE binding and recovery. To recover the PGMs, we created a bottom-up assembling strategy to construct a living hydrogel composed of a seamlessly integrated living catalyst, Shewanella loihica PV-4 (PV-4), for metal reduction, and their structural and functional linkers, bio-reduced graphene oxide (B-rGO). This hydrogel demonstrated a close to 90% recovery of model metal ions, Pd, from a simulated e-waste leaching stream with minimum-to-no biomass production. It’s also worth noting that the Pd recovery is initiated immediately after the introduction of living hydrogel, compared to conventional biocarriers that required start-up times within hours to days. Overall, these living hydrogels demonstrated superior bioactivity, structural integrity, and agility over existing biocarriers, which offers extensive opportunities to advance the biological metal recovery with unparallel efficiency, reduced energy/material consumption, and minimal environmental impact.

36 MATERIALS SCIENCE↗

2018 Annual Technology Baseline (ATB)

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts as well as information from the Energy Information Administration for fuel-based technologies. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, coal, natural gas, nuclear, and conventional biopower. This webinar presentation introduces the 2018 ATB.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Agent-Based Modeling for the Circular Economy: Lessons Learned From Three Case Studies

The circular economy (CE) aims at decoupling human activities from resource use, creating wealth in the process. Recently, many scholars have questioned the link between increased circularity and sustainability, resulting in many methodological approaches being developed for that purpose. This presentation summarizes the insights gained from the application of agent-based modeling (ABM) to study the techno-economic and social conditions promoting circularity and sustainability of three technologies: photovoltaic (PV) modules, hard disk drives (HDDs), and wind blades. Four main categories of agents are defined in the ABM: asset owners, service providers (e.g., refurbishers), recyclers, and manufacturers. Two main CE strategies are represented: lifetime extension (through repair or reuse) and recycling. The developed models start by projecting installed capacities and end-of-life (EOL) quantities. Then the theory of planned behavior - a social psychology model explaining behavior adoption based on attitude, peer influence, and costs - is used to model the asset owners' EOL decision (i.e., landfill, recycle or extend the lifetime of the asset). Then, the quantities of assets flowing to the recycler and service provider agents and quantities of materials flowing to manufacturers are computed. Recyclers' economies of scale are dynamically modeled, and the value generated by the CE strategies for the recyclers, service providers, and manufacturers is computed within the model. When data are available, avoided greenhouse gas emissions resulting from the CE strategies adoption are calculated exogenously from the ABM simulations. Results show that with improved used PV modules warranties, the reuse CE strategy adoption increases from 1% to 23% between 2020 and 2050. Similarly, improved standards could enhance HDDs end-users trust in data-wiping - a prerequisite to reuse - leading to a 3-fold increase in the reuse rate and avoid about 5 million tons of CO2 eq by 2050. Regarding wind blades, 5-15 years lifetime extension could reduce EOL blade quantities by 13%. High costs and logistic issues prevent blades from being recycled in greater quantities. One insight from the case studies is the necessity to have mature secondary markets for reuse to be a viable option. Interestingly, PV reuse is limited by the willingness of PV owners to purchase used modules (on the demand side), while HDDs reuse is constrained by the lack of trust toward data-wiping (limiting the supply of used HDDs). The six limits of the CE concepts presented by Korhonen et al. (2018) are finally used to interpret the results. The HDD case study is an exemplary lock-in, where the first accepted practice (shredding) retains most of the market. The PV results illustrate the technical limitation to reuse, as the growing demand cannot be supplied entirely with used PV modules. The wind case study shows the relevance of clearly defining physical flows - what type of waste should wind blades be considered, how should they be transported and landfilled? - a crucial consideration that also applies to PV modules. Finally, the three case studies highlight the relevance of studying a technology's technical, economic, and market material efficiency potentials altogether and the potential benefit of coupling ABM to life cycle assessment.

agent-based modeling↗

DISTINCT: Diversity in Solar Talent Through INnovative Curriculum and Training: An Integrated Research and Education Approach towards Creating Diversity and Advancing Utility-Scale Solar Technology

The DISTINCT project research objective is to develop an innovative N-port power converter for a utility-scale PV system that is modular, compact and cost-effective and that will enable the integration of a high-frequency, high-voltage solid-state transformer. The novelty of the proposed research is the electrical power conversion architecture using an N-port converter system that replaces the output 60Hz transformer with an integrated high-frequency low-weight solid-state transformer reducing power electronics and BOS costs to meet SunShot goals through modularity and direct high-voltage interconnection. A challenge in direct integration with a 13.8kV line is the high voltage handling capacity of the converters combined with high efficiency operation. The front-end converter for each port is a Neutral-Point Clamped (NPC) Multi-Level dc-dc Dual-Active Bridge (ML-DAB) which allows Maximum Power Point Tracking (MPPT). The integrated high frequency transformer provides the galvanic isolation between the PV and grid side and also steps up the low dc voltage from PV source. Following the ML-DAB stage, in each port, is an inverter with H-bridge configuration or NPC configuration. N number of NPC inverters’ outputs are cascaded to attain the per-phase line-to-neutral voltage to connect directly to the distribution grid (i.e. 13.8 kV). The cascaded inverters have the inherent advantage of using lower rated devices, smaller filters and low Total Harmonic Distortion (THD) required for PV grid interconnection. Our analysis and simulation results show improved performance on cost, efficiency, service life with zero downtime and THD. A comprehensive control scheme is presented to ensure the maximum power from each port and each phase are sent to the grid. A functional prototype of a 2-port converter with ML-DAB and cascaded H-bridges has been designed, built, and tested in a laboratory setup to verify the target technical metrics. The N-port converter system due to its modular structure with individual control per port can be easily adapted to integrate functionalities that go well beyond the conventional grid support functions and mitigates impacts of forecasted fast ramp downs or ramp ups and single-fault conditions by automatic reconfiguration of the output.

14 SOLAR ENERGY↗

Energy Efficient Buildings

Salt Lake County's Solar Photovoltaic Project - an unprecedented public/private partnership Salt Lake County is pleased to announce the completion of its unprecedented solar photovoltaic (PV) installation on the Calvin R. Rampton Salt Palace Convention Center. This 1.65 MW installation will be one the largest solar roof top installations in the country and will more than double the current installed solar capacity in the state of Utah. Construction is complete and the system will be operational in May 2012.

14 SOLAR ENERGY↗

2019 Annual Technology Baseline [Slides]

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts as well as information from the Energy Information Administration for fuel-based technologies. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage, coal, natural gas, nuclear, and conventional biopower. This webinar presentation introduces the 2019 ATB.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of high concentration photovoltaics (HCPV) power plants in the US Southwest: Economic assessment and sensitivity analysis

High concentration photovoltaic (HCPV) technologies offer several advantages over typical PV systems. In this study, a detailed economic assessment and sensitivity analysis of deploying HCPV plants in the US southwest is performed. To do this, a 20 MWdc HCPV power plant is designed using the System Advisor Model (SAM) and is evaluated from both technical and financial aspects. The sensitivity analysis shows that reducing the installed cost per capacity of the HCPV system can significantly improve the economics and reduce the levelized cost of electricity (LCOE) and levelized power purchase agreement (LPPA). Also, providing proper incentives including both investment tax credits (ITC) and production tax credit (PTC), loan debt ratio, and interest rate are among the most influential parameters. The analysis shows that with the 30% ITC, the LCOE, and LPPA of the designed HCPV projects are between $65.4/MWh and $69.3/MWh and between $71.0/MWh and $75.2/MWh, respectively. The estimated LCOE and LPPA values are almost 50% higher than the utility-scale PV projects. If proper funding is provided to continue the support of the HCPV system, they would become more economical and competitive with PV plants. Federal and state government policies must also be established to advocate HCPV systems.

14 SOLAR ENERGY↗

The Influence of a CO2 Pricing Scheme on Distributed Energy Resources in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial-sector distributed energy resources (DER) with combined heat and power (CHP) in greenhouse gas emissions (GHG) reductions. Historically, relatively little attention has been paid to the potential of medium-sized commercial buildings with peak electric loads ranging from 100 kW to 5 MW. In our research, we examine how these medium-sized commercial buildings might implement DER and CHP. The buildings are able to adopt and operate various technologies, e.g., photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, batteries and thermal storage systems. We apply the Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs and/or CO2 emissions. Using 138 representative mid-sized commercial sites in California, existing tariffs of major utilities, and expected performance data of available technologies in 2020, we find the GHG reduction potential for these buildings. We compare different policy instruments, e.g., a CO2 pricing scheme or a feed-in tariff (FiT), and show their contributions to the California Air Resources Board (CARB) goals of additional 4 GW CHP capacities and 6.7 Mt/a GHG reduction in California by 2020. By applying different price levels for CO2, we find that there is competition between fuel cells and PV/solar thermal. It is found that the PV/solar thermal adoption increases rapidly, but shows a saturation at high CO2 prices, partly due to limited space for PV and solar thermal. Additionally, we find that large office buildings are good hosts for CHP in general. However, most interesting is the fact that fossil-based CHP adoption also increases with increasing CO2 prices. We will show service territory specific results since the attractiveness of DER varies widely by climate zone and service territory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operations, maintenance, and cost considerations for PV+Storage in the United States

Battery storage systems are increasingly being installed at photovoltaic (PV) sites to address supply-demand balancing needs. Although there is some understanding of costs associated with PV operations and maintenance (O&M), costs associated with emerging technologies such as PV plus storage lack details about the specific systems and/or activities that contribute to the cost values. This study aims to address this gap by exploring the specific factors and drivers contributing to utility-scale PV plus storage systems (UPVS) O&M activities costs, including how technology selection, data collection, and related and ongoing challenges. Specifically, we used semi-structured interviews and questionnaires to collect information and insights from utility-scale owners and operators. Data was collected from 14 semi-structured interviews and questionnaires representing 51.1 MW with 64.1 MWh of installed battery storage capacity within the United States (U.S.). Differences in degradation rate, expected life cycle, and capital costs are observed across different storage technologies. Most O&M activities at UPVS related to correcting under-performance. Fires and venting issues are leading safety concerns, and owner operators have installed additional systems to mitigate these issues. There are ongoing O&M challenges due the lack of storage-specific performance metrics as well as poor vendor reliability and parts availability. Insights from this work will improve our understanding of O&M consideration at PV plus storage sites.

14 SOLAR ENERGY↗

Rooftop Solar PV Quality and Safety in Developing Countries - Key Issues and Potential Solutions

To scale solar photovoltaic (PV) deployment in developing countries, the technology must be safe and reliable, meeting both customer and utility expectations. However, challenges exist in achieving these goals. Because PV systems are novel and complex, the majority of consumers are unable to distinguish between low- and high-quality systems; many may invest based on price alone. Suboptimal PV system performance and safety incidents can have downstream impacts on the solar industry and customer adoption because of unmet expectations and negative publicity. Rooftop solar system components vary in quality, and inadequate training could lead to poor installation practices. And even if inspection checklists, certification procedures, and standards are available, they may not be widely used in countries if they are not mandatory, the workforce is not aware of them, or installers lack the technical capacity to comply. Despite the numerous solar quality and safety challenges developing countries may face, lessons learned and best practices from around the world can address them.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Fluid-electrolyte shifts and maximal oxygen uptake in man at simulated altitude /2,287 m/

Experiments were conducted on six trained distance runners (21-23 yr) subjected to an eight-day dietary control at sea level, followed by an eight-day stay in an altitude chamber (2287-m altitude) and a four-day recovery at sea level. Fluid and electrolyte shifts during exercise at altitude were evaluated to gain insight into the mechanism of reduction in working capacity. The results are discussed in terms of resting fluid volumes and blood constituents, maximal exercise variables, and maximal exercise fluid-electrolyte shifts. Since there are no significant changes in fluid balance or resting plasma volume (PV) at altitude, it is concluded that neither these nor the excessive PV shifts with exercise contribute to the reduction in maximal oxygen uptake at altitude. During altitude exposure the percent loss in PV is found to follow the percent reduction in maximal oxygen uptake; however, on the first day of recovery the percent change in PV remains depressed while maximal oxygen uptake returns to control levels.

Greenleaf, J. E.↗

Increasing Energy Access in Sub-Saharan Africa: Exploring Public-Private Models for Intervention

This report, by Morgan Bazilian and Jacquelyn Pless, examines ways that Energy+ could make a large impact in providing energy access to the poor, focusing on four promising models. While there remains a focus on a technology (PV), and a region (SSA) in this report, the models the authors explore are amenable to other specifications as well. Thus, the models presented provide an opportunity for stakeholders and the international community to collaborate and leverage capacities, resources, and networks. Of course, these models are only a few of the very wide range of possible mechanisms. They also are somewhat focused on engaging the private sector. The report does not provide a full context for the complex landscape of energy access and energy poverty. Rather, the paper is focused around the specifics of the interventions. It remains the case that the fundamental building blocks of capacity building, good governance and planning, and the ability to find funding for 'upfront' due diligence and analysis remain critical. Those items are, however, largely outside the scope of this short report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

Utility-Scale Solar Data Update (2020 Edition) [Slides]

Berkeley Lab’s 2020 update of utility-scale solar data and trends provides an overview of key trends in the U.S. market, with a focus on 2019. Highlights of this year’s update include: More than 4.5 GWAC of utility-scale solar (i.e., ground-mounted solar projects larger than 5 MWAC) achieved commercial operations in 2019, bringing cumulative capacity to 29 GWAC. Projects are spread across all 10 regions that we track, though more heavily concentrated in the sunniest regions. The median installed cost of projects that came online in 2019 fell to $\$$1.4/WAC ($\$$1.2/WDC), down 20% from 2018 and down by more than 70% from 2010. 77% of projects and 88% of capacity added in 2019 used single-axis tracking. Average capacity factors range from 17% in the least-sunny regions to 30% where it is sunniest. Single-axis tracking adds roughly five percentage points to capacity factor in the regions with the strongest solar resource. Nationwide average levelized power purchase agreement (PPA) prices fell to $\$$24/MWh in 2019, down 17% from 2018 and more than 80% since 2010. Thirty-nine projects (totaling 4.2 GWAC) in our PPA price sample include battery storage (totaling 2.3 GWAC and 9.5 GWh). In the “lower 48” states, a number of these recent PV+battery PPAs have been inked in the mid-$\$$20/MWh range (levelized in 2019 dollars).Not including the 30% investment tax credit (ITC), the median levelized cost of energy (LCOE) from utility-scale PV has declined by 85% since 2010, to $\$$40/MWh in 2019. When the 30% ITC is included within the LCOE calculation, the median LCOE closely tracks the median PPA price over time. In higher-penetration markets like CAISO, the value of solar has been declining, but falling PPA prices have largely kept pace, preserving solar's net value. At the end of 2019, there were nearly 370 GW of solar in interconnection queues from all 7 ISOs and 30 additional utilities across the country. Nearly a third of this proposed solar capacity is paired with battery storage.

14 SOLAR ENERGY↗

Electricity Produced from Photovoltaic Systems in Apartment Buildings and Self-Consumption: Comparison of the Situation in Various IEA PVPS Countries

Over the last two decades, grid-connected solar photovoltaic systems have increased from a niche market to one of the leading power generation capacity additions annually. In 2018 the total installed photovoltaic electricity generation capacity exceeded 500 GW. Another doubling is forecasted until the early 2020s. Therefore, the further development is coupled with the question at what prices solar photovoltaic electricity can be provided and delivered to the customers. The installation of PV systems for self-consumption is already now an interesting option for many people but in general limited to those who have access to a rooftop they own or can use. A new envelopment to enable residents of multi apartment buildings to commonly use electricity generated by a PV system (collective self-consumption) is a relatively new development and is still facing a lot of administrative and regulatory challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Clustering Method and Representative Feeder Selection for the California Solar Initiative

The screening process for DG interconnection procedures needs to be improved in order to increase the PV deployment level on the distribution grid. A significant improvement in the current screening process could be achieved by finding a method to classify the feeders in a utility service territory and determine the sensitivity of particular groups of distribution feeders to the impacts of high PV deployment levels. This report describes the utility distribution feeder characteristics in California for a large dataset of 8,163 feeders and summarizes the California feeder population including the range of characteristics identified and most important to hosting capacity. The report describes the set of feeders that are identified for modeling and analysis as well as feeders identified for the control group. The report presents a method for separating a utility's distribution feeders into unique clusters using the k-means clustering algorithm. An approach for determining the feeder variables of interest for use in a clustering algorithm is also described. The report presents an approach for choosing the feeder variables to be utilized in the clustering process and a method is identified for determining the optimal number of representative clusters.

14 SOLAR ENERGY↗