Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Thermohydraulic experiments on a supercritical carbon dioxide–air microtube heat exchanger

Heat exchangers are critical components in supercritical CO 2 Brayton cycles and provide necessary heat input, recovery, and dissipation. Tubular heat exchangers with unconventionally small tube sizes (tube diameters less than 5 mm) are promising components for supercritical CO 2 cycles and potentially provide excellent structural stability with wide scope of application. This paper provides essential design and fabrication guidelines for a compact shell-and-tube heat exchanger with microtubes (with an inner diameter equal to 1.75 mm). A heat exchanger test rig is used to evaluate the thermohydraulic performance of this heat exchanger with supercritical CO 2 and air as working fluids. Thermohydraulic data are reported for more than forty sets of experiments with varying Reynolds numbers for shell and tube flows. Critical performance metrics are calculated from the data and compared with predictions from a previously described numerical model. The average deviations between the experimental and model results fall within 10% for all critical metrics. This excellent agreement validates the numerical model for supercritical CO 2 heat exchanger optimization and scale-up.

42 ENGINEERING↗

Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Combined dry plasma etching and online metrology for manufacturing highly focusing x-ray mirrors

A new figuring station was designed and installed at the ESRF beamline BM05. It allows the figuring of mirrors within an iterative process combining the advantage of online metrology with dry etching. The complete process takes place under a vacuum environment to minimize surface contamination while non-contact surfacing tools open up the possibility of performing at-wavelength metrology and eliminating placement errors. The aim is to produce mirrors whose slopes do not deviate from the stigmatic profile by more than 0.1 µrad rms while keeping surface roughness in the acceptable limit of 0.1-0.2 nm rms. The desired elliptical mirror surface shape can be achieved in a few iterations in about a one day time span. This paper describes some of the important aspects of the process regarding both the online metrology and the etching process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimising Boltzmann codes for the PLANCK era

High precision measurements of the Cosmic Microwave Background (CMB) anisotropies, as can be expected from the PLANCK satellite, will require high-accuracy theoretical predictions as well. One possible source of theoretical uncertainty is the numerical error in the output of the Boltzmann codes used to calculate angular power spectra. In this work, we carry out an extensive study of the numerical accuracy of the public Boltzmann code CAMB, and identify a set of parameters which determine the error of its output. We show that at the current default settings, the cosmological parameters extracted from data of future experiments like Planck can be biased by several tenths of a standard deviation for the six parameters of the standard {Lambda}CDM model, and potentially more seriously for extended models. We perform an optimisation procedure that leads the code to achieve sufficient precision while at the same time keeping the computation time within reasonable limits. Our conclusion is that the contribution of numerical errors to the theoretical uncertainty of model predictions is well under control-the main challenges for more accurate calculations of CMB spectra will be of an astrophysical nature instead.

79 ASTRONOMY AND ASTROPHYSICS↗

On the significance of power asymmetries in Planck CMB data at all scales

We perform an analysis of the CMB temperature data taken by the Planck satellite investigating if there is any significant deviation from cosmological isotropy. We look for differences in the spectrum between two opposite hemispheres and also for dipolar modulations. We propose a new way to avoid biases due to partial-sky coverage by producing a mask symmetrized in antipodal directions, in addition to the standard smoothing procedure. We also properly take into account both Doppler and aberration effects due to our peculiar velocity and the anisotropy of the noise, since these effects induce a significant hemispherical asymmetry. We are thus able to probe scales all the way to ℓ = 2000. After such treatment we find no evidence for significant hemispherical anomalies along any of the analyzed directions (i.e. deviations are less than 1.5σ when summing over all scales). Although among the larger scales there are sometimes higher discrepancies, these are always less than 3σ. We also find results on a dipolar modulation of the power spectrum. Along the hemispheres aligned with the most asymmetric direction for 2 ≤ ℓ ≤ 2000 we find a 3.3σ discrepancy when comparing to simulations. However, if we do not restrict ourselves to Planck's maximal asymmetry axis, which can only be known a posteriori, and compare Planck data with the modulation of simulations along their respective maximal asymmetry directions, the discrepancy goes down to less than 1σ (with, again, almost 3σ discrepancies in some low-ℓ modes). We thus conclude that no significant power asymmetries seem to be present in the full data set. Interestingly, without proper removal of Doppler and aberration effects one would find spurious anomalies at high ℓ, between 3σ and 5σ. Even when considering only ℓ < 600 we find that the boost is non-negligible and alleviates the discrepancy by roughly half-σ.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration and Statistical Performance of Al2O3: C Optically Stimulated Luminescent Dosimeters With and Without Annealing Using a 137Cs Source

A series of experiments were conducted using commercially available Al 2 O 3 :C optically stimulated luminescent dosimeters to provide a technical basis for their precise calibration and statistical performance at irradiated air kerma doses between 0.02 mGy and 5 mGy using 137 Cs. This study examines the dose response linearity, studies the background signal for annealed dosimeters, and compares the statistical performance of dosimeters that were annealed and not annealed prior to their irradiation and readout. The average and standard deviation for the response of groups of dosimeters annealed and nonannealed prior to their irradiation were determined at each delivered dose. The batch of dosimeters that were annealed prior to their irradiation exhibited a coefficient of variation in its mean dose response below 10% when using three or more irradiation trials at each delivered air kerma dose between 0.02 mGy and 5m Gy. The reader calibration factor was calculated using the response of the annealed batch of dosimeters and was determined to be 756 ± 7 photomultiplier tube counts perm Gy. Best estimates of the individual sensitivity factors were determined to be between 0.79 and 1.12 for the annealed batch of dosimeters. The minimum number of irradiations required to accurately determine the sensitivity factor of each individual dosimeter is reported with the recommended reader and dosimeter calibration procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precision grid and hand motion for accurate needle insertion in brachytherapy

Purpose: In prostate brachytherapy, a grid is used to guide a needle tip toward a preplanned location within the tissue. During insertion, the needle deflects en route resulting in target misplacement. In this paper, 18-gauge needle insertion experiments into phantom were performed to test effects of three parameters, which include the clearance between the grid hole and needle, the thickness of the grid, and the needle insertion speed. Measurement apparatus that consisted of two datum surfaces and digital depth gauge was developed to quantify needle deflections. Methods: The gauge repeatability and reproducibility (GR and R) test was performed on the measurement apparatus, and it proved to be capable of measuring a 2 mm tolerance from the target. Replicated experiments were performed on a 2{sup 3} factorial design (three parameters at two levels) and analysis included averages and standard deviation along with an analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: Results showed that grid with tight clearance hole and slow needle speed increased precision and accuracy of needle insertion. The tight grid was vital to enhance precision and accuracy of needle insertion for both slow and fast insertion speed; additionally, at slow speed the tight, thick grid improved needle precision and accuracy. Conclusions: In summary, the tight grid is important, regardless of speed. The grid design, which shows the capability to reduce the needle deflection in brachytherapy procedures, can potentially be implemented in the brachytherapy procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-BRA-08: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Hybrid PET-MRI Imaging of Acute Radiation Induced Cardiac Toxicity

Purpose: To identify the presence of low-dose radiation induced cardiac toxicity in a canine model using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI). Methods: Research ethics board approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 1 week post cardiac irradiation, and 1 month post cardiac irradiation using a hybrid PET- MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess acute changes in myocardial perfusion and inflammation. Myocardial perfusion imaging was performed using N13-ammonia tracer followed by a dynamic PET acquisition scan. A compartmental tracer kinetic model was used for absolute perfusion quantification. Myocardial inflammation imaging was performed using F18-fluorodeoxyglucose (FDG) tracer. The standard uptake value (SUV) over a region encompassing the whole heart was used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard deviation) to heart was 1.8±0.2 Gy. Reductions in myocardial stress perfusion relative to baseline were observed in 2 of the 5 animals 1 month post radiation. A global inflammatory response 1 month post radiation was observed in 4 of the 5 animals. The calculated SUV at 1 month post radiation was significantly higher (p=0.05) than the baseline SUV. Conclusion: Low doses of cardiac irradiation (< 2 Gy) may lead to myocardial perfusion defects and a global inflammatory response that can be detectable as early as 1 month post irradiation using hybrid PET-MRI imaging techniques.

60 APPLIED LIFE SCIENCES↗

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location

Pacific Northwest National Laboratory performed a demonstration to determine the acceptable location in which to place an air sampling probe for emissions monitoring for radionuclides in the exhaust air discharge from the new 3430 Building Filtered Exhaust Stack. The method was to adopt the results of a previously performed test series for a system of similar configuration, followed by a partial test on the actual system to verify the applicability of previously performed tests. The qualification criteria included 1) a uniform air velocity, 2) an average flow angle that does not deviate from the axis of the duct by more than 20°, 3) a uniform concentration of tracer gases, and 4) a uniform concentration of tracer particles. Section 1 provides background information for the demonstration, and Section 2 describes the test strategy, including the criteria for the applicability of model results and the test matrix. Section 3 describes the flow -angle test and the velocity uniformity test, Section 4 provides the test results, and Section 5 provides the conclusions. Appendix A includes the test data sheets, and Appendix B gives applicable qualification results from the previously tested model stack. The data from the previously tested and similarly designed stack was demonstrated to be applicable to the current design for the 3430 Building Filtered Exhaust Stack. The 3430 stack was tested in both January and May of 2010 to document the results of several changes that were made to the exhaust system after the January tests. The 3430 stack meets the qualification criteria given in the American National Standards Institute/Health Physics Society N13.1 standard. Changes to the system configuration or operations outside of the bounds of this report (e.g., exhaust velocity increases, relocation of sample probe) will require retesting/reevaluation to determine compliancewith the requirements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Classical Molecular Dynamics Simulation of Nuclear Fuel

Molecular dynamics simulation is well suited to study primary damage production by irradiation, defect interactions with fission gas atoms, gas bubble nucleation, grain boundary effects on defect and gas bubble evolution in nuclear fuel, and the resulting changes in thermo-mechanical properties. In these simulations, the forces on the ions are dictated by interaction potentials generated by fitting properties of interest to experimental data. The results obtained from the present generation of potentials are qualitatively similar, but quantitatively different. There is a need to refine existing potentials to provide a better representation of the performance of polycrystalline fuel under a variety of operating conditions, and to develop models that are equipped to handle deviations from stoichiometry. In addition to providing insights into fundamental mechanisms governing the behaviour of nuclear fuel, MD simulations can also provide parameters that can be used as inputs for mesoscale models.

Devanathan, Ram↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Monte Carlo based, patient-specific RapidArc QA using Linac log files

Purpose: A Monte Carlo (MC) based QA process to validate the dynamic beam delivery accuracy for Varian RapidArc (Varian Medical Systems, Palo Alto, CA) using Linac delivery log files (DynaLog) is presented. Using DynaLog file analysis and MC simulations, the goal of this article is to (a) confirm that adequate sampling is used in the RapidArc optimization algorithm (177 static gantry angles) and (b) to assess the physical machine performance [gantry angle and monitor unit (MU) delivery accuracy]. Methods: Ten clinically acceptable RapidArc treatment plans were generated for various tumor sites and delivered to a water-equivalent cylindrical phantom on the treatment unit. Three Monte Carlo simulations were performed to calculate dose to the CT phantom image set: (a) One using a series of static gantry angles defined by 177 control points with treatment planning system (TPS) MLC control files (planning files), (b) one using continuous gantry rotation with TPS generated MLC control files, and (c) one using continuous gantry rotation with actual Linac delivery log files. Monte Carlo simulated dose distributions are compared to both ionization chamber point measurements and with RapidArc TPS calculated doses. The 3D dose distributions were compared using a 3D gamma-factor analysis, employing a 3%/3 mm distance-to-agreement criterion. Results: The dose difference between MC simulations, TPS, and ionization chamber point measurements was less than 2.1%. For all plans, the MC calculated 3D dose distributions agreed well with the TPS calculated doses (gamma-factor values were less than 1 for more than 95% of the points considered). Machine performance QA was supplemented with an extensive DynaLog file analysis. A DynaLog file analysis showed that leaf position errors were less than 1 mm for 94% of the time and there were no leaf errors greater than 2.5 mm. The mean standard deviation in MU and gantry angle were 0.052 MU and 0.355 deg., respectively, for the ten cases analyzed. Conclusions: The accuracy and flexibility of the Monte Carlo based RapidArc QA system were demonstrated. Good machine performance and accurate dose distribution delivery of RapidArc plans were observed. The sampling used in the TPS optimization algorithm was found to be adequate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A highly specific test for periodicity

We present a method that allows to distinguish between nearly periodic and strictly periodic time series. To this purpose, we employ a conservative criterion for periodicity, namely, that the time series can be interpolated by a periodic function whose local extrema are also present in the time series. Our method is intended for the analysis of time series generated by deterministic time-continuous dynamical systems, where it can help telling periodic dynamics from chaotic or transient ones. We empirically investigate our method's performance and compare it to an approach based on marker events (or Poincaré sections). We demonstrate that our method is capable of detecting small deviations from periodicity and outperforms the marker-event-based approach in typical situations. Our method requires no adjustment of parameters to the individual time series, yields the period length with a precision that exceeds the sampling rate, and its runtime grows asymptotically linear with the length of the time series.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computerized image analysis: Texture-field orientation method for pectoral muscle identification on MLO-view mammograms

Purpose: To develop a new texture-field orientation (TFO) method that combines a priori knowledge, local and global information for the automated identification of pectoral muscle on mammograms. Methods: The authors designed a gradient-based directional kernel (GDK) filter to enhance the linear texture structures, and a gradient-based texture analysis to extract a texture orientation image that represented the dominant texture orientation at each pixel. The texture orientation image was enhanced by a second GDK filter for ridge point extraction. The extracted ridge points were validated and the ridges that were less likely to lie on the pectoral boundary were removed automatically. A shortest-path finding method was used to generate a probability image that represented the likelihood that each remaining ridge point lay on the true pectoral boundary. Finally, the pectoral boundary was tracked by searching for the ridge points with the highest probability lying on the pectoral boundary. A data set of 130 MLO-view digitized film mammograms (DFMs) from 65 patients was used to train the TFO algorithm. An independent data set of 637 MLO-view DFMs from 562 patients was used to evaluate its performance. Another independent data set of 92 MLO-view full field digital mammograms (FFDMs) from 92 patients was used to assess the adaptability of the TFO algorithm to FFDMs. The pectoral boundary detection accuracy of the TFO method was quantified by comparison with an experienced radiologist's manually drawn pectoral boundary using three performance metrics: The percent overlap area (POA), the Hausdorff distance (Hdist), and the average distance (AvgDist). Results: The mean and standard deviation of POA, Hdist, and AvgDist were 95.0{+-}3.6%, 3.45{+-}2.16 mm, and 1.12{+-}0.82 mm, respectively. For the POA measure, 91.5%, 97.3%, and 98.9% of the computer detected pectoral muscles had POA larger than 90%, 85%, and 80%, respectively. For the distance measures, 85.4% and 98.0% of the computer detected pectoral boundaries had Hdist within 5 and 10 mm, respectively, and 99.4% of computer detected pectoral muscle boundaries had AvgDist within 5 mm from the radiologist's manually drawn boundaries. Conclusions: The pectoral muscle on DFMs can be detected accurately by the automated TFO method. The preliminary study of applying the same pectoral muscle identification algorithm to FFDMs without retraining demonstrates that the TFO method is reasonably robust against the differences in the image properties between the digitized and digital mammograms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forecasting Solar-Thermal Systems Performance under Transient Operation Using a Data-Driven Machine Learning Approach Based on the Deep Operator Network Architecture

Modeling and prediction of the dynamic behavior of thermal systems operating under intermittent energy input and variable load requirements represent one of the greatest challenges in the development of efficient and reliable renewable-based power generation technologies. In this work, a data-driven machine learning modeling framework was developed based on a modified version of the Deep Operator Network architecture where the time coordinate in the trunk net is replaced with historical data of the predicting quantity. The modeling framework can be used to accurately predict the performance of renewable-based energy conversion technologies including wind- and solar-based power plants. This novel framework was applied on a solar-thermal system that consists of a solar collection loop using a flat plate collector, a power generation loop comprising an Organic Rankine Cycle, and a thermal energy storage tank connecting both loops. Variable solar irradiance, air temperature, and power load profiles were used by the Deep Operator Network to predict the State-of-Charge and the efficiency of the thermal system for several days. The results were compared with the State-of-Charge and efficiency functions calculated using a physics-based model. For a simple operation scenario, characterized by a clear sky solar irradiance profile and constant load, the standard deviation in the State-of-Charge prediction by Deep Operator Network is below 0.9% during a seven-day prediction time horizon. For the most realistic operation scenario that considers real solar irradiance and a rough load profile, the maximum standard deviation in the predictions for the State-of-Charge and efficiency are below 6.8% and 2.5%, respectively. A comparison between Deep Operator Network and Long Short Term Memory network was also performed. In general, both networks predict very well the State-of-Charge for different data density conditions; however, a higher accuracy, with a standard deviation below 2.0%, is obtained by the Deep Operator Network during three and half days using sparser training data of 20-minute points. The same accuracy for the State-of-Charge prediction with the Long Short Term Memory network is achieved only for 14 h. Average standard deviations for the State-of-Charge prediction of 1.1% with the Deep Operator Network and 1.5% with the Long Short Term Memory network are obtained for a four-day prediction time using a denser training data of 5-minute points.

DeepONet↗

Deep Learning Reconstruction of Daily Soil CO 2 Efflux Reveals Biogeochemical Insights and Reduces Annual Estimate Uncertainty Despite Limited Daily Predictability

Soil CO 2 efflux is commonly measured monthly or seasonally, leaving daily dynamics poorly resolved and contributing to global estimation uncertainty. We trained a single Long Short-Term Memory (LSTM) model to predict daily soil CO 2 efflux across 82 globally distributed sites in COSORE, with 0.2%–46.9% daily data coverage from 2003 to 2020. Despite using far fewer sites than are typically used to train a single deep learning model, with observations biased toward temperate mesic sites, the LSTM model performed well at approximately one-third of sites, reconstructed nearly 2 decades of daily efflux, and outperformed commonly used approaches for estimating daily efflux when applied to the same data set. Performance was weakest at pronounced peaks and troughs and at non-temperate sites with <1.5 years of observations and irregular data patterns. Nevertheless, annual efflux from reconstructed daily data had <40% error even at underperforming sites, substantially improving estimates derived from monthly and seasonal sampling (maximum errors of 95% and 136%, respectively). Temperature sensitivity (Q 10 ) estimated from reconstructed daily predictions closely matched estimates from daily observations, whereas Q 10 values derived from monthly or seasonal observations deviated substantially, suggesting that coarse temporal sampling may contribute to uncertainty in reported Q 10 values. Consistent daily reconstructions further enabled trend analyses for well-performing, predominantly temperate sites and showed increasing soil CO 2 efflux at most sites from 2003 to 2020, with more variable summer trends. Despite limitations, these results demonstrate the potential of LSTM models to reconstruct daily soil CO 2 efflux and reduce estimation uncertainties from sparse observations.

Smykalov, Valerie [Pennsylvania State University, ↗

In situ contact angle measurements of liquid CO 2 , brine, and Mount Simon sandstone core using micro X-ray CT imaging, sessile drop, and Lattice Boltzmann modeling

Three techniques to measure and understand the contact angle, θ, of a CO 2 /brine/rock system relevant to geologic carbon storage were performed with Mount Simon sandstone. Traditional sessile drop measurements of CO 2 /brine on the sample were conducted and a water-wet system was observed, as is expected. A novel series of measurements inside of a Mount Simon core, using a micro X-ray computed tomography imaging system with the ability to scan samples at elevated pressures, was used to examine the θ of residual bubbles of CO 2 . Within the sandstone core the matrix appeared to be neutrally wetting, with an average θ around 90°. A large standard deviation of θ (20.8°) within the core was also observed. To resolve this discrepancy between experimental measurements, a series of Lattice Boltzmann model simulations were performed with differing intrinsic θ values. The model results with a θ = 80° were shown to match the core measurements closely, in both magnitude and variation. The small volume and complex geometry of the pore spaces that CO 2 was trapped in is the most likely explanation of this discrepancy between measured values, though further work is warranted.

42 ENGINEERING↗

Frequency stabilization of a 1083 nm fiber laser to {sup 4}He transition lines with optical heterodyne saturation spectroscopies

Two kinds of optical heterodyne saturation spectroscopies, namely, frequency modulation spectroscopy (FMS) and modulation transfer spectroscopy (MTS), are demonstrated for locking a fiber laser to the transition lines of metastable {sup 4}He atoms around 1083 nm. The servo-loop error signals of FMS and MTS for stabilizing laser frequency are optimized by studying the dependence of the peak-to-peak amplitude and slope on the optical power of pump and probe beams. A comparison of the stabilization performances of FMS/MTS and polarization spectroscopy (PS) is presented, which shows that MTS exhibits relatively superior performance with the least laser frequency fluctuation due to its flat-background dispersive signal, originated from the four-wave mixing process. The Allan deviation of the stabilized laser frequency is 5.4 × 10{sup −12}@100 s with MTS for data acquired in 1000 s, which is sufficiently applicable for fields like laser cooling, optical pumping, and optical magnetometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗