Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phase Changing Materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Advancing Metasurfaces Towards New Frontiers: Nonvolatile Reconfigurable Optics

The applications of adaptive optics extend across multiple sectors, encompassing areas such as LiDAR, biological and chemical sensing, and free-space communications. In this study, we report on the design, fabrication, testing, and modeling of electrically reconfigurable metasurfaces using a low-loss high contrast phase change material, Ge2Sb2Se4Te integrated with an IR-transparent silicon microheater. Through this work, we introduce a reliable architecture for switching PCM-based metasurfaces within an integrated circuit configuration which is compatible with standard foundry fabrication processes. We demonstrate the capability of controlling the transmission of electromagnetic waves through the precise stimulation of PCM-based pixels, each spanning a few hundred microns, over numerous cycles. By leveraging PCM-based pixels, we unlock the potential to create metasurfaces encompassing a diverse range of functionalities such as dielectric filters, metalens, or beam steering devices, which is governed by the design of the meta-atoms. Further, we perform an in-depth investigation into the failure mechanism utilizing techniques such as Fourier transform IR spectroscopy (FTIR), transmission electron microscopy (TEM), energy dispersive spectroscopy (EDS), and thermal modeling. According to our results, due to a sharp temperature rise at the PCM/heater interface, we observe severe delamination of the PCM from the heater. More uniform PCM deposition, better adhesion at the PCM/heater interface, and a more uniform temperature distribution in the device could potentially mitigate the failure and lead to a longer life-time. By addressing these challenges, we aim to unlock the full potential of PCM-based devices and advance the field of adaptive optics.

Phase change material↗

Performance Evaluation of Advanced Retrofit Roof Technologies Using Field-Test Data Phase Three Final Report, Volume 1

This article presents various metal roof configurations that were tested at Oak Ridge National Laboratory in Tennessee, U.S.A. between 2009 and 2013, and describes their potential for reducing the attic-generated space conditioning loads. These roofs contained different combinations of phase change material, rigid insulation, low emittance surface and above-sheathing ventilation, with standing-seam metal panels on top. These roofs were designed to be installed on existing roofs decks, or on top of asphalt shingles for retrofit construction. All the tested roofs showed the potential for substantial energy savings compared to an asphalt shingle roof, which was used as a control for comparison. The roofs were constructed on a series of adjacent attics separated at the gables using thick foam insulation. The attics were built on top of a conditioned room. All attics were vented at the soffit and ridge. The test roofs and attics were instrumented with an array of thermocouples. Heat flux transducers were installed in the roof deck and attic floor (ceiling) to measure the heat flows through the roof and between the attic and conditioned space below. Temperature and heat flux data were collected during the heating, cooling and swing seasons over a 3 year period. Data from previous years of testing have been published. Here, data from the latest roof configurations being tested in year 3 of the project are presented. All test roofs were highly effective in reducing the heat flows through the roof and ceiling, and in reducing the diurnal attic temperature fluctuations.

above sheating ventilation↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Transport properties of cubic crystalline Ge 2 Sb 2 Te 5 : a potential low-temperature thermoelectric material.

Ge 2 Sb 2 Te 5 (GST) has been widely used as a popular phase change material. In this study, we show that it exhibits high Seebeck coe cients 200 - 300 μV/K in its cubic crystalline phase (c-GST) at remarkably high p-type doping levels of 1 10 19 - 6 10 19 cm -3 at room temperature. More importantly, at low temperature (T = 200 K), the Seebeck coe cient was found to exceed 200 μV/K for a doping range 1 10 19 - 3.5 10 19 cm -3 . Given that the lattice thermal conductivity in this phase has already been measured to be extremely low ( 0.7 W/m-K at 300 K), our results suggest the possibility of using c-GST as a low-temperature thermoelectric material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Techno-Economic Optimization of Advanced Energy Plants with Integrated Thermal, Mechanical, and Electro-Chemical Storage (Final Report)

The increasing use of renewable energy sources is leading to increased cycling of fossil-fueled power plants (FFPP) that are designed to operate at base-loaded conditions. Integrating energy storage facilities with the FFPPs can be helpful in reducing load-following operation of FFPPs. Decentralized deployment of energy storage facilities at the FFPP level has considerable advantages due to possibilities of smaller storage capacities, immediate benefits realized by the host power plant due to the increase in the efficiency, cleaner emission and higher plant life to name a few. Most importantly, deployment at the FFPP level can exploit the existing equipment items and facilities at the host power plant, thus reducing the CAPEX and reducing the storage capacity. However, realization of these benefits will critically depend on novel configuration/integration strategies with the least impact on the power plant operation and its configuration. Furthermore, dynamics of the entire integrated system including both the FFPP and the storage technologies must be taken into account to obtain the cost-optimal solution. With these motivations, the objective of this project was to complete a focused evaluation of decentralized deployments of energy storage facilities at the FFPP level. Promising thermal, chemical, mechanical, and electro-chemical storage technologies were evaluated with due consideration of their transient response to obtain various optimal system concepts that can minimize the levelized cost of storage. For thermal storage, cryogenic energy storage along with high temperature heat storage in molten salt as well as phase change material were evaluated. For mechanical storage, cryogenic air storage and pumped hydro storages were evaluated. For chemical storage, hydrogen storage was evaluated. For electrochemical storage, the team evaluated sodium sulfur, vanadium redox flow battery as well as Li-ion batteries. Integration of these storage technologies with the natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants was considered. Six technologies, namely molten salt, cryogenics, compressed air, pumped hydro, H2 storage and Li-ion battery storage, were downselected based on their levelized cost of storage. It was observed that the ranking of the optimal storage technology can differ based on the host power plant technology even when same demand/supply/price profile for electricity are considered. It was also observed that as the variability in power demand varies, the ranking of the optimal storage technologies vary. However, for the same demand and LMP profile, top six optimal storage technologies for NGCC vs SCPC plants did not differ much even though LCOS for the same technology and optimal size of a given storage technology did differ. Detailed techno-economic assessment of these six technologies was undertaken.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Transfer and Latent Heat Storage in Inorganic Molten Salts for Concentrating Solar Power Plants

A key technological issue facing the success of future Concentrating Solar Thermal Power (CSP) plants is creating an economical Thermal Energy Storage (TES) system. Current TES systems use either sensible heat in fluids such as oil, or molten salts, or use thermal stratification in a dual-media consisting of a solid and a heat-transfer fluid. However, utilizing the heat of fusion in inorganic molten salt mixtures in addition to sensible heat, as in a Phase change material (PCM)-based TES, can significantly increase the energy density of storage requiring less salt and smaller containers. A major issue that is preventing the commercial use of PCM-based TES is that it is difficult to discharge the latent heat stored in the PCM melt. This is because when heat is extracted, the melt solidifies onto the heat exchanger surface decreasing the heat transfer. Even a few millimeters of thickness of solid material on heat transfer surface results in a large drop in heat transfer due to the low thermal conductivity of solid PCM. Thus, to maintain the desired heat rate, the heat exchange area must be large which increases cost. This project demonstrated that the heat transfer coefficient can be increase ten-fold by using forced convection by pumping a hyper-eutectic salt mixture over specially coated heat exchanger tubes. However, only 15% of the latent heat is used against a goal of 40% resulting in a projected cost savings of only 17% against a goal of 30%. Based on the failure mode effect analysis and experience with pumping salt at near freezing point significant care must be used during operation which can increase the operating costs. Therefore, we conclude the savings are marginal to justify using this concept for PCM-TES over a two-tank TES. The report documents the specialty coatings, the composition and morphology of hypereutectic salt mixtures and the results from the experiment conducted with the active heat exchanger along with the lessons learnt during experimentation.

14 SOLAR ENERGY↗

Comparative study of single and multi-layered packed-bed thermal energy storage systems for CSP plants

The Multi-layered Thermal Energy Storage (TES) tank consists of three regions–top and bottom part is packed with suitable Phase Change Materials (PCM) and low-cost pebbles are placed in the middle region, whereas entire tank portion is filled by solid fillers in Single-layered tank system. For a storage tank operating between 563 and 663 K with bed dimensions of 12 and 14.38 m using Solar salt as Heat Transfer Fluid (HTF), it is observed that the duration of discharge for multi-layered tank is 5.32 h whereas it is 4.19 h for single-layered tank with a Reynolds number of 10. The effect of intermediate melting temperature range of PCMs are also analyzed by taking PCMs with sharp as well as intermediate melting ranges. Further, comparison of single and multi-layered systems is carried out by analyzing the temperature profiles and width of both PCM layers. The width of top and bottom PCM layers of tank is varied from 0 to 30% to analyze its effect on the discharging duration. It is observed that multi-layered system provides extra discharge of 1 h with introduction of PCM at top and bottom with a width of 10%. Discharge duration increases with increase in PCM width whereas the percentage increase in duration of discharge with increase in PCM width is comparatively less. It is also seen that PCMs with sharp melting point performs better compared to one having intermediate range of melting temperatures. Multi-layered configuration concept offers best possibilities as integration to CSP plants with desired efficiency.

14 SOLAR ENERGY↗

Examination of the temperature dependent electronic behavior of GeTe for switching applications

The DC and RF electronic behaviors of GeTe-based phase change material switches as a function of temperature, from 25 K to 375 K, have been examined. In its polycrystalline (ON) state, GeTe behaved as a degenerate p-type semiconductor, exhibiting metal-like temperature dependence in the DC regime. This was consistent with the polycrystalline (ON) state RF performance of the switch, which exhibited low resistance S-parameter characteristics. In its amorphous (OFF) state, the GeTe presented significantly greater DC resistance that varied considerably with bias and temperature. At low biases (<1 V) and temperatures (<200 K), the amorphous GeTe low-field resistance dramatically increased, resulting in exceptionally high amorphous-polycrystalline (OFF-ON) resistance ratios, exceeding 10{sup 9} at cryogenic temperatures. At higher biases and temperatures, the amorphous GeTe exhibited nonlinear current-voltage characteristics that were best fit by a space-charge limited conduction model that incorporates the effect of a defect band. The observed conduction behavior suggests the presence of two regions of localized traps within the bandgap of the amorphous GeTe, located at approximately 0.26–0.27 eV and 0.56–0.57 eV from the valence band. Unlike the polycrystalline state, the high resistance DC behavior of amorphous GeTe does not translate to the RF switch performance; instead, a parasitic capacitance associated with the RF switch geometry dominates OFF state RF transmission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental characterization of a triply periodic minimal surface PCM-to-air thermal energy storage device

Here, the expansion of energy production has intensified research into thermal energy storage (TES) to manage variability and improve system efficiency. Heat exchanger design is critical to achieving high power densities in TES systems. This study presents a high-surface-area phase change material (PCM)-to-air heat exchanger fabricated via resin-based stereolithography with a novel gyroid-based geometry tailored for enhanced performance. Material properties of the commercial PCM and resin were characterized using analytical techniques. A controlled air loop was used to evaluate heat transfer and pressure drop at various flow rates and inlet temperatures. Results show a strong dependence on the inlet temperature difference (ΔT) relative to the PCM melting point. During charging at the highest flow rate, increasing the inlet air temperature from ΔT = 5 °C to 20 °C above the melting point increased the average heat transfer rate by 187%. During discharging, decreasing the inlet temperature by the same ΔT below the melting point led to a 232% increase. Notably, the high-surface-area design enabled nearly symmetric charging and discharging behavior, a novel result for PCM-based TES systems which are often restricted by natural convection and other effects. The overall heat transfer coefficient was calculated and compared to values from standard design correlations. The maximum thermal effectiveness reached 95% at ΔT = 20 °C and a moderate flow rate of 34 m 3 /h. Peak coefficients of performance (COP) of 7 during charging and 6.4 during discharging were observed at ΔT = 20 °C and a low flow rate of 20 m 3 /h. These results demonstrate the viability of additively manufactured geometries for advanced TES applications.

25 ENERGY STORAGE↗

Harnessing Ocean Thermal Gradients Using Thermoelectric Based Submersibles for Ocean Power Applications

The urgent need for energy solutions in marine environments has accelerated the development of innovative technologies capable of leveraging natural resources for power generation. This study introduces a buoyancy-driven submersible system designed to harness ocean thermal gradients using thermoelectric generators (TEGs) and phase change materials (PCMs). The technology aims to provide autonomous power to offshore aquaculture farms, unmanned underwater vehicles (UUVs), offshore platform illumination, and ocean sensors, significantly reducing dependence on fossil fuels. Ocean thermal gradients, especially prevalent in mid-latitude regions, exhibit temperature differences between surface and deep waters ranging from 7 degrees Celsius to 30 degrees Celsius depending on seasonal variations. The proposed submersible technology utilizes TEGs to convert thermal energy from these gradients into electrical power, generating between 0.2 and 0.5 watts, while PCMs are employed to store and regulate this energy, ensuring a stable and continuous power supply. The buoyancy-driven mechanism of the submersible enhances its capability to navigate through varying depths, optimizing its exposure to different thermal gradients and maximizing energy harvesting. The performance of this submersible system is analyzed through detailed thermodynamic assessments and computational fluid dynamics (CFD) modeling focused on heat transfer. These analyzes consider real-world ocean temperature profiles and seek to refine the interaction between TEGs and PCMs to optimize energy extraction. The evaluation encompasses several key performance metrics, including power output and energy efficiency. Results confirm the potential of this innovative technology to provide a continuous and reliable power source for marine applications. By demonstrating the feasibility of using ocean thermal gradients for energy generation, this study contributes to the broader efforts of innovation in energy technologies for harsh, remote marine environments. The implementation of such promises is significant advancements in the autonomy of marine operations. The ongoing research will further investigate scalability ensuring that the system can be effectively adapted to various marine settings and operational demands.

16 TIDAL AND WAVE POWER↗

Compressed Expanded Natural Graphite (CENG) Processing for PCM Composites

The use of phase change materials (PCMs) in thermal energy storage applications has received considerable attention in recent decades. Organic PCMs are popular due to their high latent heat of fusion, noncorrosive properties, and relative stability over many charge and discharge cycles. A primary limitation of these materials is their low thermal conductivity. This has led researchers to develop various methods to increase thermal conductivity by seeding PCM with or impregnating them into more conductive materials. One method is to impregnate PCMs into compressed expanded natural graphite (CENG) matrices, which can improve thermal conductivity by a factor of 100. CENG matrices have received particular interest due to their low cost, high porosity, small (nano/micro) pore size, high pore density, high thermal conductivity, and ability to be compressed into many geometries. PCM/CENG matrix composites have been extensively studied; however, the effect that CENG processing has on PCM saturation and the overall matrix thermal conductivity has not been well investigated. This processing includes four major steps including graphite intercalation, thermal shock, compression, and PCM saturation. Intercalation involves soaking graphite flakes in sulfuric and/or nitric acid to intercalate the acids between the graphene layers. The graphite flakes are then subjected to a high-temperature thermal shock, during which the intercalated acid is gasified rapidly, pushing the graphene layers apart, resulting in accordion-shaped graphite "worms". The "worms" are then compacted to a desired bulk density and then soaked with molten PCM until fully saturated. The properties of the produced CENG matrix, and its ability to allow PCM permeation, are sensitive to the processing parameters, namely, the thermal shock temperature and exposure time, as well as the matrix apparent density or porosity. Here, we study the effect of the thermal shock conditions necessary to expand intercalated graphite flakes on PCM saturation and the expanded graphite's thermal conductivity and morphology. We found that the thermal shock temperature exhibits the greatest influence. At greater shock temperatures, SEM images showed that expanded graphite worms exhibited greater density of pores, thus increasing total surface area within the matrices. Increasing thermal shock temperature yielded greater overall PCM saturation, as well as an increased rate of saturation. Improvements in PCM saturation rate and overall saturation are obtained as the shock temperature is increased. Longer exposure to thermal shock also improves initial saturation rates and is beneficial if a shortened impregnation time is needed. Thermal shock conditions did not impact thermal conductivity; however, conductivity was largely affected by matrix porosity. A local maximum in axial thermal conductivity was observed at around 83% porosity, which is similar to that observed in previous studies.

compressed expanded natural graphite↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Effects of carbon concentration on the local atomic structure of amorphous GST

Ge-Sb-Te (GST) alloys are leading phase-change materials for data storage due to the fast phase transition between amorphous and crystalline states. Ongoing research aims at improving the stability of the amorphous phase to improve retention. This can be accomplished by the introduction of carbon as a dopant to Ge 2 Sb 2 Te 5 , which is known to alter the short- and mid-range structure of the amorphous phase and form covalently bonded C clusters, both of which hinder crystallization. The relative importance of these processes as a function of C concentration is not known. Here we used molecular dynamics simulation based on density functional theory to study how carbon doping affects the atomic structure of GST-C. Carbon doping results in an increase in tetrahedral coordination, especially of Ge atoms, and this is known to stabilize the amorphous phase. We observe an unexpected, non-monotonous trend in the number of tetrahedral bonded Ge with the amount of carbon doping. Our simulations show an increase in the number of tetrahedral bonded Ge up to 5 at.% C, after which the number saturates and begins to decrease above 14 at.% C. The carbon atoms aggregate into clusters, mostly in the form of chains and graphene flakes, leaving less carbon to disrupt the GST matrix at higher carbon concentrations. Different degrees of carbon clustering can explain divergent experimental results for recrystallization temperature for carbon doped GST.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Evaluation of a Mass Efficient Heat Storage Device.

The heat sponge is a device for mass-efficient storage of heat. It was developed to be incorporated in the substructure of a reentry or hypersonic vehicle to reduce thermal protection system requirements. The heat sponge consists of a liquid-vapor mixture contained within a number of miniature pressure vessels that can be embedded within a variety of different types of structures. As temperature is increased, pressure in the miniature pressure vessels also increases so that heat absorbed through vaporization of the liquid is spread over a relatively large temperature range. Using water as a working fluid, the heat storage capacity of the liquid-vapor mixture is many times higher than that of typical structural materials and is well above that of common phase change materials over the temperature range of 660oR to 1160oR. Prototype heat sponges were fabricated and characterized. These heat sponges consisted of 1.0 inch diameter hollow stainless steel spheres with a wall thickness of 0.020 inches which had varying percentages of their interior volumes filled with water. An apparatus to measure the heat stored in these prototype heat sponges was designed, fabricated, and verified. The heat storage capacity calculated from measured temperature histories is compared to numerical predictions.

Splinter, Scott C.↗

Heat Sponge: A Concept for Mass-Efficient Heat Storage

The heat sponge is a device for mass-efficient storage of heat. It was developed to be incorporated in the substructure of a re-entry vehicle to reduce thermal- protection-system requirements. The heat sponge consists of a liquid/vapor mixture contained within a number of miniature pressure vessels that can be embedded within a variety of different types of structures. As temperature is increased, pressure in the miniature pressure vessels also increases so that heat absorbed through vaporization of the liquid is spread over a relatively large temperature range. Using water as a working fluid, the heat-storage capacity of the liquid/vapor mixture is many times higher than that of typical structural materials and is well above that of common phase change materials over a temperature range of 200 F to 700 F. The use of pure ammonia as the working fluid provides a range of application between 432 deg R and 730 deg R, or the use of the more practical water-ammonia solution provides a range of application between 432 deg R and 1160 deg R or in between that of water and pure ammonia. Prototype heat sponges were fabricated and characterized. These heat sponges consisted of 1.0-inch-diameter, hollow, stainless-steel spheres with a wall thickness of 0.020 inches which had varying percentages of their interior volumes filled with water and a water-ammonia solution. An apparatus to measure the heat stored in these prototype heat sponges was designed, fabricated, and verified. The heat-storage capacity calculated from measured temperature histories is compared to numerical predictions.

Splinter, Scott C.↗

Kinetics of solid-solid phase transitions in metals using proton radiography (u)

When a compressed material changes phase it doesn't do so instantly. Instead it transitions through a mixed phase as it transforms to the end state phase for a given pressure, volume and temperature. Common phase diagrams show the phase boundaries as sharp lines when compression has been slowly applied and held for an infinite amount of time. When the compression is applied with high strain rate, however, the phase boundaries are no longer crisp as the kinetic effects of the crystal reorientation delay the transitions, resulting in regions of mixed phase. This opens up the possibility that some degree of metastability exists for such transition in dynamic compression. The compression path can go past the equilibrium phase boundary and the transition happen from a metastable state because of the very short timescale of the compression process. Molecular dynamics (MD) simulations recently have been used to examine shock-induced phase transitions in single crystal materials illustrating an orientation dependence of the transition stress, mechanisms, kinetics, and Hugoniot response. For example, the [100] orientation of iron had a simulated transition stress higher than the experimentally determined polycrystalline value of 13 GPa by 2 GPa. Previously, dynamic experiments on iron have observed a non-zero transition time and width in the solid-solid {alpha}-{var_epsilon} phase transition. Using Proton Radiography at the Los Alamos Neutron Science Center, we have performed plate impact experiments on iron to further study the {alpha}-{var_epsilon} phase transition which occurs at 13 GPa. A 40mm bore powder gun was coupled to a proton radiography beam line and imaging system and synchronized to the impact of the projectile on the target sample with the proton beam pattern. A typical experimental configuration for the iron study, as shown below in 3 color-enhanced radiographs, is a 40mm diameter aluminum sabot impacting a 40mm diameter sample of polycrystalline ARMCO iron. The iron is backed by a sapphire optical window for velocimetry measurements. The aluminum flyer on the left of the iron is barely visible for visual display purposes.

36 MATERIALS SCIENCE↗